Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plastic Scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An approach towards plastic scintillators from thermally activated delayed fluorescent dyes and cross-linkable bismuth compounds

Cross-linked polyvinyltoluene (PVT) based plastic scintillators loaded with dyes exhibiting thermally activated delayed fluorescence (TADF) and various amounts of (caproate)di-(methacrylate) bismuth (CMB) were developed. The co-polymerization of vinyl toluene monomer loaded with different weight ratios of CMB and 1 wt% of TADF dye yielded highly transparent cross-linked plastic scintillators with intense green photoluminescence. The thermal and mechanical properties of the scintillators were investigated using thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and micro indentation techniques. Here, their performance for radiation detection was assessed by performing gamma spectroscopy using a Cs-137 source and benchmarked to commercial plastic scintillators. The loading of CMB was guided by Monte Carlo N-Particle (MCNP) simulations. The results of this study show that the cross-linking approach and the use of TADF dyes yield scintillators with good mechanical properties with a uniaxial yield strength up to ~66 MPa for compositions loaded with 40 wt% of CMB and high optical quality. However, the light yield in gamma spectroscopy experiments is found to be reduced with the addition of CMB, suggesting a trade-off between mechanical yield strength and light yield in gamma spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of proton quenching in a plastic scintillator detector

The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks' constants are extracted from the data, and found to be $k_B = (8.70 \pm 0.93)\times 10^{-3}\ {\rm g/cm^2/MeV}$ and $k_C = (1.42 \pm 1.00) \times 10^{-5}\ {\rm (g/cm^2/MeV)^2}$. This result covers a unique energy range that is of direct relevance for fast neutron backgrounds in reactor inverse beta decay detectors. Furthermore, these measurements will improve the energy non-linearity modeling of plastic scintillator detectors. In particular, the updated energy response model will lead to an improvement of fast neutron modeling for detectors based on the CHANDLER reactor neutrino detector technology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Highly lead-loaded red plastic scintillators as an X-ray imaging system for the Laser Mega Joule

The scope of this project intends to record spatially resolved images of core shape and size of a DT micro-balloon during Inertial Confinement Fusion (ICF) experiments at Laser Mega Joule facility (LMJ). We need to develop an X-ray imaging system which can operate in the radiative background generated by an ignition shot of ICF. The scintillator is a part of the imaging system and has to gather a compromise of scintillating properties (scintillating efficiency, decay time, emission wavelength) so as to both operate in the hard radiative environment and to allow the acquisition of spatially resolved images. Inorganic scintillators cannot be used because no compromise can be found regarding the expected scintillating properties, most of them are not fast enough and emit blue light. Organic scintillators are generally fast, but present low X-ray absorption in the 10 to 40 keV range, that does not permit the acquisition of spatially resolved images. To this aim, we have developed highly lead-loaded and red-fluorescent fast plastic scintillators. Such a combination is not currently available via scintillator suppliers, since they propose only blue-fluorescent plastic scintillators doped with up to 12%w Pb. Thus, incorporation ratio up to 27%w Pb has been reached in our laboratory, which can afford a plastic scintillator with an outstanding Z{sub eff} close to 50. X-rays in the 10 to 40 keV range can thus be detected with a higher probability of photoelectric effect than for classic organic scintillators, such as NE102. The strong orange-red fluorescence can be filtered, so that we can eliminate residual Cerenkov light, generated by {gamma}-ray absorption in glass parts of the imaging system. Decay times of our scintillators evaluated under UV excitation were estimated to be in the range 10 to 13 ns. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using handheld plastic scintillator detectors to triage individuals exposed to a radiological dispersal device

After a radiological dispersal device (RDD) event, people could become internally contaminated by inhaling dispersed radioactive particles. A rapid method to screen individuals who are internally contaminated is desirable. Such initial screening can help in prompt identification of those who are highly contaminated and in prioritizing individuals for further and more definitive evaluation such as laboratory testing. The use of handheld plastic scintillators to rapidly screen those exposed to an RDD with gamma-emitting radionuclides was investigated in this study. The Monte Carlo N-Particle transport code was used to model two commercially available plastic scintillation detectors in conjunction with anthropomorphic phantom models to determine the detector response to inhaled radionuclides. Biokinetic models were used to simulate an inhaled radionuclide and its progression through the anthropomorphic phantoms up to 30 d after intake. The objective of the study was to see if internal contamination levels equivalent to 250 mSv committed effective dose equivalent could be detected using these instruments. Five radionuclides were examined: {sup 60}Co, {sup 137}Cs, {sup 192}Ir, {sup 131}I and {sup 241}Am. The results demonstrate that all of the radionuclides except {sup 241}Am could be detected when placing either one of the two plastic scintillator detector systems on the posterior right torso of the contaminated individuals.

61 RADIATION PROTECTION AND DOSIMETRY↗

Predictive model of scintillator plastic fogging in portals

We have developed a science-based predictive model for fogging of the scintillator plastics deployed in radiation portal monitors. The only input required is the weather conditions [i.e., daily high and low, for temperature and relative humidity (R.H.)]. The code utilizes this information, together with a thermodynamic model of the water content in equilibrium with the plastic surface, a diffusion model of the water transport into the interior of scintillator plastic panel, and a comparison of the resulting paired “water-content/night-temperature” points as a function of position in the panel against an empirical “fog-line” that establishes a water/temperature criterion for the onset of fogging. In conclusion, we have analyzed the behavior of several representative portal monitor sites, and the output of the model analysis is reasonably consistent with observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-167: Characterization of In-House Plastic Scintillator Detectors Array for Radiation Therapy

Purpose: To characterize basic performance of plastic scintillator detectors (PSD) array designed for dosimetry of radiation therapy. Methods: An in-house PSD array has been developed by placing single point PSD into customized 2D holder. Each point PSD is a plastic scintillating fiber-based detector designed for highly accurate measurement of small radiotherapy fields used in patient plan verification and machine commissioning and QA procedures. A parallel fiber without PSD is used for Cerenkov separation by subtracting from PSD readings. Cerenkov separation was confirmed by optical spectroscopy. Alternative Cerenkov separation approaches are also investigated. The optical signal was converted to electronic signal with a photodiode and then subsequently amplified. We measured its dosimetry performance, including percentage depth dose and output factor, and compared with reference ion chamber measurements. The PSD array is then placed along the radiation beam for multiple point dose measurement, representing subsets of PDD measurements, or perpendicular to the beam for profile measurements. Results: The dosimetry results of PSD point measurements agree well with reference ion chamber measurements. For percentage depth dose, the maximal differences between PSD and ion chamber results are 3.5% and 2.7% for 6MV and 15MV beams, respectively. For the output factors, PSD measurements are within 3% from ion chamber results. PDD and profile measurement with PSD array are also performed. Conclusions: The current design of multichannel PSD array is feasible for the dosimetry measurement in radiation therapy. Dose distribution along or perpendicular to the beam path could be measured. It might as well be used as range verification in proton therapy.A PS hollow fiber detector will be investigated to eliminate the Cerenkov radiation effect so that all 32 channels can be used.

60 APPLIED LIFE SCIENCES↗

Detecting sub-MeV neutrons in solid plastic scintillator with gamma-ray discrimination

We report on recent efforts to design a solid plastic scintillation hodoscope to measure neutron production cross sections at low energies. Our program includes not only the development of the detector itself, but also a set of auxiliary measurements which will help characterize its low-energy response. A novel scintillation counter has been developed to detect sub-MeV neutrons while rejecting gamma-ray backgrounds with good efficiency. The detector uses multiple layers of thin solid scintillator, with optical isolation between the adjacent layers. Incident low-energy neutrons produce ionizing recoil particles which remain within just one of the scintillator layers, while background gamma rays create electrons which most often cross the boundary between layers. By observing the trigger pattern within the layers, most gamma-ray backgrounds can be distinguished from the low-energy neutrons of interest. We report on the results of our Monte Carlo studies of this design, as well as on the operation of a prototype detector unit. We also have undertaken a new measurement of the neutron-proton total cross section below 1 MeV. Calculations of the efficiency for detecting low energy neutrons in plastic scintillator rely on accurate low energy n-p cross sections, yet surprisingly few such data currently exist. New measurements which span the region from 150 to 800 keV neutron (lab) energy are reported and discussed. Additionally, we have measured the light response of BC 418 scintillator for recoil proton energies as low as 100 keV. Recoil protons are produced at a known energy in the scintillator by placing it in a neutron beam and detecting in coincidence the elastically scattered neutrons at fixed angle. Our new results extend the energy range of previous measurements of the light response of solid organic scintillators, and may indicate a significantly modified response at the lowest observed energies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-476: Quality Assurance for Gamma Knife Perfexion Using the Exradin W1 Plastic Scintillation Detector

Purpose: To perform dose profile and output factor measurements for the Exradin W1 plastic scintillation detector (PSD) for the Gamma Knife Perfexion (GKP) collimators in a Lucy phantom and to compare these values to an Exradin A16 ion chamber, EBT3 radiochromic film and treatment planning system (TPS) data. Methods: We used the Exradin W1 PSD which has a small volume, near-water equivalent sensitive element. It has also been shown to be energy independent. This new detector is manufactured and distributed by Standard Imaging, Inc. Measurements were performed for all three collimators (4 mm, 8 mm and 16 mm) for the GKP. The Lucy phantom with the PSD inserted was moved in small steps to acquire profiles in all three directions. EBT3 film was inserted in the Lucy phantom and exposed to a single shot for each collimator. Relative output factors were measured using the three detectors while profiles acquired with the PSD were compared to the ones measured with EBT3 radiochromic film. Results: Measured output factors relative to the largest collimator are as followsCollimator PS EBT3 A1616mm 1.000 1.000 1.0008mm 0.892 0.881 0.8834mm 0.795 0.793 0.727 The nominal (vendor) OFs for GKP are 1.000, 0.900, and 0.814, for collimators 16 mm, 8 mm and 4 mm, respectively. There is excellent agreement between all profiles measured with the PSD and EBT3 as well as with the TPS data provided by the vendor. Conclusion: Output factors measured with the W1 were consistent with the ones measured with EBT3 and A16 ion chamber. Measured profiles are in excellent agreement. The W1 detector seems well suited for beam QA for Gamma Knife due to its dosimetric characteristics. Sam Beddar would like to disclose a NIH/NCI SBIR Phase II grant (2R44CA153824-02A1) with Standard Imaging, Title: “Water-Equivalent Plastic Scintillation Detectors for Small Field Radiotherapy”.

07 ISOTOPE AND RADIATION SOURCES↗

High-Z Sensitized Plastic Scintillators: A Review

The need for affordable and reliable radiation detectors has prompted significant investment in new radiation detector materials, due to concerns about national security and nuclear nonproliferation. Plastic scintillators provide an affordable approach to large volume detectors, yet their performance for high-energy gamma radiation is severely limited by the small radiation stopping power inherent to their low atomic number. Although some sensitization attempts with organometallics were made in the 1950s to 1960s, the concomitant decrease in light yield has limited the usefulness of these sensitized detectors. Recently, with new knowledge gained during the rapid development of organic optoelectronics and nanotechnology, there has been a revived interest in the field of heavy element sensitized plastic scintillators. In this paper, the recent efforts on sensitized plastic scintillators are summarized. Basic scintillator physics is first reviewed. The discussion then focuses on two major thrusts in the field: sensitization with: (1) organometallics and (2) oxide and fluoride nanoparticles. The design rationales and major results are examined in detail, with existing limitations and possible future pathways discussed. Lastly, special attention is paid to the underlying energy deposition and transfer processes, as these determine the key performance metrics such as light yield and radioluminescence decay lifetime.

36 MATERIALS SCIENCE↗

WE-AB-BRB-06: A Temperature Independent Plastic Scintillation Detector Capable of Simultaneous Dose and Temperature Measurement

Purpose: To evaluate a measurement method that renders plastic scintillation detectors temperature independent and capable of recovering dose and temperature information simultaneously. Methods: A novel approach was developed to account for the temperature dependence of plastic scintillation detectors (PSDs) without prior knowledge of the temperature. To enable this, the optical response of the scintillating element is separated into two sub-components, one being the response at a given temperature and the other accounting for the change in the optical emission spectrum with temperature. Using a previously demonstrated hyperspectral approach and following the proper calibration protocol, the contribution to scintillator emission and physical value of both dose and temperature can be obtained in real-time. To validate the method, dose and temperature were measured under cobalt irradiation in a temperature controlled water tank developed for this study. The temperature was varied from 22°C to 42°C. Depth-dose curves were also obtained during irradiations from a linear accelerator, first maintaining the water at room temperature and then warming it to 40°C and letting it cool down naturally over the course of the second measurement. Results: Dose measurements delivered with the Co-60 unit showed an average relative difference to the expected value of (1.0±0.8)%, with a maximum difference of 2.3% over the entire range of temperatures. The measured temperatures using the PSD were all within 1°C of the expected values. The difference between room temperature and warmer depth dose measurements differed by only (1.2±0.4)%. The dosimeter showed to be accurate for temporal resolution down to 0.1s. Conclusion: The proposed method was shown to reliably correct for the temperature dependence of a PSD. Additionally, it makes it possible to assess the temperature at the point of measurement. These are significant advances in PSD technology, particularly in relation to real-time in vivo dosimetry. Part of this research was supported by the Odyssey Program at The University of Texas MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Transparent plastic scintillators for neutron detection based on lithium salicylate

Transparent plastic scintillators with pulse shape discrimination containing 6 Li salicylate have been synthesized by bulk polymerization with a maximum 6 Li loading of 0.40 wt%. Photoluminescence and scintillation responses to gamma-rays and neutrons are reported in this paper. Plastics containing 6 Li salicylate exhibit higher light yields and permit a higher loading of 6 Li as compared to previously reported plastics based on lithium 3-phenylsalicylate. However, pulse shape discrimination performance is reduced in lithium salicylate plastics due to the requirement of adding more nonaromatic monomers to the polymer matrix as compared to those based on lithium 3-phenylsalicylate. Finally, reduction in light yield and pulse shape discrimination performance in lithium-loaded plastics as compared to pulse shape discrimination plastics without lithium is interpreted in terms of energy transfer interference by the aromatic lithium salts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D printable polyvinyltoluene-based plastic scintillators with pulse shape discrimination

A feasibility of preparing bulk photopolymerized plastics scintillators that contain vinyltoluene with multifunctional monomers, pentaerythritol tetraacrylate is shown. This formulation offers a simple and fast way to prepare polyvinyltoluene-based plastics with efficient fast neutron/gamma pulse shape discrimination (PSD) within minutes. 30 wt% of 2,5-diphenyloxazole (PPO) was added in the mixtures of vinyltoluene and pentaerythritol tetraacrylate with different secondary dyes to understand the effect of dyes on the scintillation. Prepared resins were photopolymerized under different conditions, and the scintillation performance was compared to a commercially available standard, EJ-276. Additional functionality for thermal neutron sensitivity was introduced by the incorporation of 6 Li and 6 B nuclei. With optimized conditions, prepared plastics showed light output up to 90% relative to the same size of EJ-276. Here, the best plastic scintillators had PSD figures of merit (FoMs) up to 2.77 compared to 3.25 of EJ-276. The 3D-printability of the tested formulations was demonstrated.

36 MATERIALS SCIENCE↗

Neutron response characterization for an EJ299-33 plastic scintillation detector

Organic scintillation detectors have shown promise as neutron detectors for characterizing special nuclear materials in various arms-control and homeland security applications. Recent advances have yielded a new plastic scintillator - EJ299-33 - with pulse-shape-discrimination (PSD) capability. Plastic scintillators would have a much expanded range of deployment relative to liquids and crystals. Here in this paper, we present a full characterization of pulse height response to fission-energy neutrons for an EJ299-33 detector with 7.62-by-7.62-cm cylindrical active volume, and compare with an EJ309 liquid scintillator in the same assembly. Scintillation light output relations, energy resolutions, and response matrices are presented for both detectors. A Continuous spectrum neutron source, obtained via the bombardment of 27 Al with 7.44-MeV deuterons at the Edwards Accelerator Facility at Ohio University, was used for the measurement. A new procedure for evaluating and comparing PSD performance is presented which accounts for the effect of the light output relation on the ability to detect low energy neutrons. The EJ299-33 is shown to have considerable deficit in matrix condition, and in PSD figure of merit when compared to EJ309, especially when neutron energy is taken into account. Furthermore the EJ299 is likely to bring a modest PSD capability into a array of held applications that are not accessible to liquids or crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bismuth- and lithium-loaded plastic scintillators for gamma and neutron detection

In this paper, transparent plastic scintillators based on polyvinyltoluene (PVT) have been fabricated with high loading of bismuth carboxylates for gamma spectroscopy, and with lithium carboxylates for neutron detection. When activated with a combination of standard fluors, 2,5-diphenyloxazole (PPO) and tetraphenylbutadiene (TPB), gamma light yields with 15 wt% bismuth tripivalate of 5000 Ph/MeV are measured. A PVT plastic formulation including 30 wt% lithium pivalate and 30 wt% PPO offers both pulse shape discrimination, and a neutron capture peak at ~400 keVee. Finally, in another configuration, a bismuth-loaded PVT plastic is coated with ZnS( 6 Li) paint, permitting simultaneous gamma and neutron detection via pulse shape discrimination with a figure-of-merit of 3.8, while offering gamma spectroscopy with energy resolution of R(662 keV)=15%.

36 MATERIALS SCIENCE↗

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-423: TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors

Purpose: To perform dose profile and output factor (OF) measurements with the Exradin W1 plastic scintillation detector (PSD) for small fields made by the high-definition multi-leaf collimator (MLC) on the TrueBeam STx system and to compare them to values measured with an IBA CC01 ionization chamber and a Sun Nuclear Edge detector diode for 6 MV photon beams. Methods: The Exradin W1 is a new small volume near-water equivalent and energy independent PSD manufactured by Standard Imaging, Inc. All measurements were performed in an IBA Blue Phantom water tank. Square MLC-shaped fields with sides ranging from 0.5 cm to 2 cm and jawshaped fields with sides ranging from 1 cm to 40 cm were measured using an SAD setup at 10 cm depth. Dose profile and percent depth dose (PDD) measurements were also taken under the same conditions for MLC fields 0.5×0.5 and 1×1 cm2 in size with jaws at 2×2cm2. The CC01 and W1 were vertically mounted. Results: OFs measured with the W1 for jaw only square fields were consistent with the ones measured with a Farmers PTW TN33013 ion chamber (1.8% maximum deviation). OF and penumbra measurement results are presented below. PDDs measured for all detectors are within 1.5% for the 0.5×0.5 cm2 and within 1% for the 1×1 cm2 MLC fields.Output factors:MLC size W1 CC01 EDGE0.5cm 0.555 0.541 0.5851.0cm 0.716 0.702 0.7331.5cm 0.779 0.761 0.7772.0cm 0.804 0.785 0.796Penumbras (mm):MLC size W1 CC01 EDGE0.5cm 2.7 2.9 2.51.0cm 3.0 3.4 2. Conclusion: OFs measured for small MLC fields were consistent with the ones measured with the other stereotactic detectors. Measured penumbras are consistent with detector size. The Exradin W1 PSD is an excellent choice for characterizing MLC-shaped small beam dosimetry used for stereotactic radiosurgery and body radiation therapy. Sam Beddar would like to disclose a NIH/NCI SBIR Phase II grant (2R44CA153824-02A1) with Standard Imaging, Title: “Water-Equivalent Plastic Scintillation Detectors for Small Field Radiotherapy”.

07 ISOTOPE AND RADIATION SOURCES↗