Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Physical Security Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Rapid Monitoring and Defense Approach for Resilience Improvement of Grid Cyber Security

Cyber-physical systems and electric utilities significantly depend on the reliability and efficiency of information and operational technology. However, false data injection attacks based on synchrophasor measurement data pose a serious threat to the safe and reliable operation of modern power systems. Here, to mitigate this problem, a rapid monitoring and defense approach is proposed to defend against cyber attacks. Initially, the Time and Frequency based Convolutional neural Network (TFCN) is proposed to detect different types of attacks. Within the TFCN, the advances are that both time and frequency domain information can be fused without extra spectrum analysis methods, and can save detection time to speed the calculation efficiency using the developed time-frequency block. Next, a comprehensive defense strategy is developed for multiple cyber attacks to ensure the stability and resilience of the power system according to the feedback detection results. The advances of this strategy are that different control strategies can be automatically selected to recover the stability to the greatest extent according to the detected attacks. To verify the effectiveness of the proposed approach, the high-speed frequency measurements collected from the wide-area monitoring system are used. The results demonstrate that the cyber attack detection performance can reach 95.57% accuracy, outperforming both traditional and some advanced neural networks. Importantly, the defense strategy is conducted and verified in a modified IEEE 39 bus system as well, which illustrates profound performance in faster stability restoration.

Comprehensive defense strategy↗

Systems and methods for control system security

A resilient security agent determines a cyber and/or physical health of a control system by, inter alia, communicating cyber-physical key data through cyber-physical control paths of the system, and determining error introduced by the communication. The resilient security agent may be further configured to verify the integrity of acquired cyber-physical state information. The cyber health of the control system may be evaluated by comparing the acquired cyber state information to one or more cyber state profiles. The physical health of the control system may be evaluated by comparing the acquired physical state information to one or more physical state profiles.

97 MATHEMATICS AND COMPUTING↗

Improving the Cyber Resiliency and Security Posture of Public Power (Final Report)

The key objective of Improving the Cyber Resiliency and Security Posture of Public Power (Project) was to develop a culture of cyber resiliency and security within the public power community. The relative smaller size and unique structure of community-owned electric utilities can sometimes present challenges in immediate recognition of threats and the escalation of potential incidents. The Project offered targeted education, coordination, capability building, and resources to help the public power community better understand, install, and implement cyber and physical resiliency and security systems. The American Public Power Association (APPA) accelerated efforts to develop resources for and with the public power community to understand and implement resiliency, cybersecurity and cyber-physical solutions, including refining and improving the adoption of advanced control concepts. The Project consisted of four major multi-pronged tasks which included: 1) Advance cyber resiliency and security assessments; 2) Conduct, evaluate, and use the results of onsite vulnerability assessments; 3) Research, evaluate, deploy, and integrate both commercial and pre-commercial security technologies; and 4) Research, evaluate, and implement information sharing mechanisms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multilayered Network Models for Security: Enhancing System Security Engineering with Orchestration

Security engineering approaches can often focus on a particular domain—physical security, cyber security, or personnel security, for example. Yet, security systems engineering consistently faces challenges requiring socio-technical solutions to address evolving and dynamic complexity. While some drivers of this complexity stem from complex risk environments, innovative adversaries, and disruptive technologies, other drivers are endogenous and emerge from the interactions across security engineering approaches. In response, INCOSE's Systems Security Working Group identified the need to better coordinate “disparate security solutions [that] operate independently” as one of eleven key concepts in their IS21 FuSE Security Roadmap. From this perspective, this need for “security orchestration” aligns with the perspective that security is a property that emerges from interactions within complex systems. Current efforts at Sandia National Laboratories are developing a systems security engineering approach that describes high consequence facility (HCF) security as a multidomain set of interacting layers. The result is a multilayered network (MLN)-based approach that captures the interactions between infrastructure, physical components, digital components, and humans in nuclear security systems. This article will summarize the MLN-based approach to HCF security and describe two preliminary results demonstrating potential benefits from incorporating interactions across disparate security solutions. Here, leveraging the logical structure of networks, this MLN model-based approach provides an example of how security orchestration provides enhanced systems security engineering solutions.

42 ENGINEERING↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Validating a Dynamic PWR Safety and Security Model?

Nuclear power plants (NPPs) are assessed for safety and security using separate models that cannot capture how an attacker's decisions and a plant's response unfold together in real time, leaving regulators and operators without a complete picture of true plant vulnerability. Traditional probabilistic risk assessment (PRA) methods treat adversarial events as fixed initiators with predetermined outcomes, and are structurally incapable of representing the time-dependent interplay between physical security events, safety system response, and operator mitigative actions. At Idaho National Laboratory (INL), I contributed to the development and validation of Modeling and Analysis for Safety and Security using the Dynamic EMRALD Framework (MASS-DEF). Where static PRA relies on event-tree logic that cannot evolve mid-scenario, MASS-DEF couples a time-dependent dynamic PRA tool EMRALD (Event Modeling Risk Assessment using Linked Diagrams) with attack simulation software, allowing attacker behavior, plant system states, and operator actions to interact across time. My work focused on validating a general Pressurized Water Reactor (PWR) model. I traced model logic against PWR plant to identified errors in logic and confirm accuracy. I then built and tested attack scenarios against a general PWR model to verify that the model produced expected outcomes across all logical pathways. I also contributed a section to a related technical paper applying the same EMRALD platform to radiation dose modeling. Results show that MASS-DEF can quantitatively demonstrate that many plants exceed their regulatory security thresholds. This demonstrated margin provides a technically defensible basis for reducing the number of guards without compromising regulatory compliance. Physical security costs represent roughly 10% of annual operating budgets, making such reductions directly meaningful to INL's mission of sustaining existing commercial NPPs. This internship strengthened my understanding of nuclear systems, probabilistic modeling, and technical writing, and has solidified my pursuit of a career at a national laboratory.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Cyber-Physical Tabletop Exercise for Small Modular Reactor Facilities

U.S. nuclear power facilities face increasing challenges in meeting dynamic security requirements caused by evolving and expanding threats while keeping costs reasonable to make nuclear energy competitive. This evolving threat landscape includes adversaries having offensive cyber capabilities to attack information technology (IT) systems and operation technology (OT) systems. These adversaries may have the ability to attack the physical protection system (PPS) networks with potential consequential impacts that could degrade the effectiveness of the PPS. These cyber attacks may also be used to attack the safety and operational systems used to operate and ensure the safety of the reactor. Additionally, adversaries may gain access to unmanned aerial systems (UAS) that may be used to provide reconnaissance and surveillance of the facility, provide information to the adversaries, and be equipped with kinetic capabilities such as explosives or weapons that can be used to directly attack the facility. The Department of Energy’s Office of Nuclear Energy’s Advanced Reactor Safeguards and Security (ARSS) program funded Sandia National Laboratories (SNL) and Idaho National Laboratory (INL) to develop a cyber-physical tabletop exercise (TTX). This exercise was conducted on a hypothetical small modular reactor (SMR) facility, and only considered a potential adversary cyber attack on the PPS to a physical attack on the hypothetical facility to achieve a radiological release. This cyber-physical TTX is meant to provide lessons learned to integrate the cyber security system design and the physical protection system (PPS) design to decrease design, operation, and maintenance costs as well as increase effectiveness for defending against design basis threat attacks at the facility. This TTX will also provide a framework and method for SMR and microreactor vendors to conduct their own cyber-physical TTX and gain impactful insights to improving the cyber and physical protection system design for their SMR or microreactor facility design.

42 ENGINEERING↗

Hardware-in-the-Loop Testbed for Cyber-Physical Security of Photovoltaic Farms

In the last decades, modem grids with distributed energy resources, such as photovoltaic (PV) farms, are increasingly vulnerable to cyber-attacks that seriously affect the stability and performance of the power system. While cyber-physical security of smart grids is extensively studied, most of the existing work focuses on the grid level and neglects the modeling and features of device-level power electronics converters (PECs). Furthermore, establishing a high-fidelity simulation testbed that can simulate harmonic frequencies of the PV farm is in urgent need. In this paper, a high-fidelity and real-time hardware-in- the-loop testbed is built to simulate the harmonics of power electronics converters for cyber-physical security of PEC-enabled PV farms. Based on this testbed, the impact of typical cyber-attacks and physical faults on the PV converter can be analyzed, thus providing a foundation for cyber-attack detection, root cause diagnosis, and resilient control to mitigate the adverse effects of cyber-attacks.

14 SOLAR ENERGY↗

Cyber physical attack detection

A cyber-security threat detection system and method stores physical data measurements from a cyber-physical system and extracts synchronized measurement vectors synchronized to one or more timing pulses. The system and method synthesizes data integrity attacks in response to the physical data measurements and applies alternating parametrized linear and non-linear operations in response to the synthesized data integrity attacks. The synthesis renders optimized model parameters used to detect multiple cyber-attacks.

97 MATHEMATICS AND COMPUTING↗

Cyber physical attack detection

A cyber-security threat detection system and method stores physical data measurements from a cyber-physical system and extracts synchronized measurement vectors synchronized to one or more timing pulses. The system and method synthesize data integrity attacks in response to the physical data measurements and applies alternating parameterized linear and non-linear operations in response to the synthesized data integrity attacks. The synthesis renders optimized model parameters used to detect multiple cyber-attacks.

Ferragut, Erik M.↗

Real-World Cyber Security Demonstration for Networked Electric Drives

In this article, we present the design and implementation of a cyber-physical security testbed for networked electric drive systems, aimed at conducting real-world security demonstrations. To our knowledge, this is one of the first security testbeds for networked electric drives, seamlessly integrating the domains of power electronics and computer science, and cybersecurity. By doing so, the testbed offers a comprehensive platform to explore and understand the intricate and often complex interactions between cyber and physical systems. The core of our testbed consists of four electric machine drives, meticulously configured to emulate small-scale but realistic information technology (IT) and operational technology (OT) networks. This setup both provides a controlled environment for simulating a wide array of cyber-attacks, and mirrors potential real-world attack scenarios with a high degree of fidelity. The testbed serves as an invaluable resource for the study of cyber-physical security, offering a practical and dynamic platform for testing and validating cybersecurity measures in the context of networked electric drive systems. As a concrete example of the testbed's capabilities, we have developed and implemented a Python-based script designed to execute step-stone attacks over a wireless local area network (WLAN). This script leverages a sequence of target IP addresses, simulating a real-world attack vector that could be exploited by adversaries. To counteract such threats, we demonstrate the efficacy of our developed cyber-attack detection algorithms, which are integral to our testbed's security framework. Furthermore, the testbed incorporates a real-time visualization system using InfluxDB and Grafana, providing a dynamic and interactive representation of networked electric drives and their associated security monitoring mechanisms. This visualization component not only enhances the testbed's usability but also offers insightful, real-time data for researchers and practitioners, thereby facilitating a deeper understanding of cyber-physical security dynamics in networked electric drive systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resource Cybersecurity Framework Best Practices

Current cybersecurity challenges for distributed energy resources (DERs) stem from the integration of various systems and the cyber-physical security concerns they bring. Although frameworks exist for industrial control systems and other energy systems, a simple guided tool that can prioritize recommended actions for controls specific to DERs is lacking. Additionally, the novelty of the field has made it difficult to create a standardized procedure for DERs with cybersecurity in mind. In response to this critical need to address cybersecurity risk management, the National Renewable Energy Laboratory (NREL) has developed a framework and accompanying web application known as the Distributed Energy Resources Cybersecurity Framework (DERCF) (Powell, 2019). A brief overview of the DERCF can be found in Section 1.2. This document provides a guide to cybersecurity best practices identified by technical research and site visits where the framework was used to assess the cybersecurity posture of DER systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-to-End Encryption for Cyber-Physical Systems Using Fully Homomorphic Encryption

Cyber-physical systems require reliable, safe, and secure control of critical infrastructure, combining computational and networking capabilities, which heighten the risk of cyber attacks. These attacks can disrupt the physical process, causing unforeseen consequences. One solution is the use of fully homomorphic encryption (FHE) to protect the control loop, allowing for secure computations and communications without compromising signal and control system privacy. The challenge with FHE, however, is its requirement for inputs to be integers. This presentation introduces a modified Learning With Errors (LWE) FHE approach that encodes control system dynamics and signals into integers. Our proposed scheme leverages a generalized LWE encoding function and modifies the Gentry-Sahai-Waters gadget decomposition tool to encrypt the control system. Using the modified LWE scheme, we formalize a fully encrypted control system, supported by simulated results.

97 MATHEMATICS AND COMPUTING↗

Physical Layer Security at a Point-to-Point MIMO System With 1-Bit DACs and ADCs

Low-resolution converters reduce the power consumption of wireless devices and help enable large energy-efficient arrays. In this letter, we evaluate the secrecy rate for the extreme case of 1-bit single-user multiple-input multiple-output systems following two signaling approaches. In the first method, the system uses discrete signaling. In the second, the system combines Gaussian signaling with artificial noise alongside power allocation. In the first case, we give a closed-form expression of the secrecy rate and propose an algorithm that provides near-optimal results for low signal-to-noise ratios (SNRs). Further, in the second scenario, depending on the channel state information, we suggest different precoding plans and derive a secrecy rate lower bound. At low SNR, power is allocated to the main signal. Only at high SNR is optimal power allocation effective. Moreover, knowing the eavesdropper channel greatly improves the system’s secrecy.

1-bit digital-to-analog (DAC) and analog-to-digita↗

Cyber-Informed Engineering Principles: What’s in it for me?

CIE is an emerging method to integrate cybersecurity considerations into the conception, design, development, and operation of any physical system that has digital connectivity, monitoring, or control. CIE complements—but does not replace—the application of cybersecurity standards or practices currently in place within an organization. Rather, it expands cybersecurity decisions into the engineering space, not by asking engineers to become cyber experts, but by calling on engineers to apply engineering tools and make engineering decisions that improve cybersecurity outcomes. CIE examines the engineering consequences that a sophisticated cyber attacker could achieve, and drives engineering changes that may provide deterministic mitigations to limit or eliminate those consequences. Engineers and technicians that design critical energy infrastructure installations can integrate the 12 principles of CIE into each phase of the engineering lifecycle, from concept to retirement. These principles are aimed at system or design engineers, operators, and technicians, rather than software engineers or operational cybersecurity practitioners, because the engineers who design, build, operate, and maintain the physical infrastructure are best positioned to leverage a system’s engineering design to diminish the severity of cyber attacks or digital technology failures. This approach creates new opportunities for engineering teams—and not just cybersecurity teams—to secure the system using the physics and mechanics of engineering controls—not just digital monitoring and controls.

99 GENERAL AND MISCELLANEOUS↗

2021 Annual Report Laboratory Directed Research & Development

The Department of Energy’s (DOE) Laboratory Directed Research and Development (LDRD) program is an essential pathway for innovation, capability growth, and research staff development at Idaho National Laboratory (INL). This program enables timely and agile response to national security, energy, and environmental challenges that motivate INL’s mission to discover and demonstrate innovative nuclear energy solutions and other clean energy options as well as securing our critical infrastructure. This report highlights INL’s LDRD projects concluding in fiscal year (FY) 2021 which included innovative research and development (R&D) across INL’s five science and technology initiatives: nuclear reactor sustainment and expanded deployment, integrated fuel cycle solutions, integrated energy systems, advanced design and manufacturing for extreme environments, and secure and resilient cyber-physical systems.

99 GENERAL AND MISCELLANEOUS↗