Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photocathode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multi-anode microchannel arrays - New detectors for imaging and spectroscopy in space

Consideration is given to the construction and operation of multi-anode microchannel array detector systems having formats as large as 256 x 1024 pixels. Such arrays are being developed for imaging and spectroscopy at soft X-ray, ultraviolet and visible wavelengths from balloons, sounding rockets and space probes. Both discrete-anode and coincidence-anode arrays are described. Two types of photocathode structures are evaluated: an opaque photocathode deposited directly on the curved-channel MCP and an activated cathode deposited on a proximity-focused mesh. Future work will include sensitivity optimization in the different wavelength regions and the development of detector tubes with semitransparent proximity-focused photocathodes.

Timothy, J. G.↗

Calculation of resolution for a windowless charge coupled device (CCD)-Digicon

A new version of an intensified charge-coupled device (ICCD) system, which is based on the incorporation of a CsI mesh photocathode and a thinned backside-illuminated CCD into a Space Telescope design Digicon tube, is being developed for future use in space-based observations in the Extreme Ultraviolet waveband. In this paper, a report is presented of the results of computer simulations involving the effects of the non-uniform electrostatic field near the mesh photocathode on imaging properties (especially, the spread function and modulation transfer function) of the detector system. The results are of importance in the design of the front end of the tube and the selection of optimum tube operating conditions. The overall resolution characteristics of the tube, including the effects of the mesh, the electron optics of the region between the mesh photocathode and the CCD target, and the structure of the CCD itself, are estimated.

Jia, X. Z.↗

Development of high resolution imaging detectors for x ray astronomy

This final report summarizes our past activities and discusses the work performed over the period of 1 April 1990 through 1 April 1991 on x-ray optics, soft x-ray (0.1 - 10 KeV) imaging detectors, and hard x-ray (10 - 300 KeV) imaging detectors. If microchannel plates (MCPs) can be used to focus x-rays with a high efficiency and good angular resolution, they will revolutionize the field of x-ray optics. An x-ray image of a point source through an array of square MCP pores compared favorably with our ray tracing model for the MCP. Initial analysis of this image demonstrates the feasibility of MCPs for soft x-rays. Our work continues with optimizing the performance of our soft x-ray MCP imaging detectors. This work involves readout technology that should provide improved MCP readout devices (thin film crossed grid, curved, and resistive sheets), defect removal in MCPs, and photocathode optimization. In the area of hard x-ray detector development we have developed two different techniques for producing a CsI photocathode thickness of 10 to 100 microns, such that it is thick enough to absorb the high energy x-rays and still allow the photoelectrons to escape to the top MCP of a modified soft x-ray imaging detector. The methods involve vacuum depositing a thick film of CsI on a strong back, and producing a converter device that takes the place of the photocathode.

Murray, S. S.↗

Miniaturized, High-Speed, Modulated X-Ray Source

A low-cost, miniature x-ray source has been developed that can be modulated in intensity from completely off to full intensity on nanosecond timescales. This modulated x-ray source (MXS) has no filaments and is extremely rugged. The energy level of the MXS is adjustable from 0 to more than 100 keV. It can be used as the core of many new devices, providing the first practical, arbitrarily time-variable source of x-rays. The high-speed switching capability and miniature size make possible many new technologies including x-ray-based communication, compact time-resolved x-ray diffraction, novel x-ray fluorescence instruments, and low- and precise-dose medical x-rays. To make x-rays, the usual method is to accelerate electrons into a target material held at a high potential. When the electrons stop in the target, x-rays are produced with a spectrum that is a function of the target material and the energy to which the electrons are accelerated. Most commonly, the electrons come from a hot filament. In the MXS, the electrons start off as optically driven photoelectrons. The modulation of the x-rays is then tied to the modulation of the light that drives the photoelectron source. Much of the recent development has consisted of creating a photoelectrically-driven electron source that is robust, low in cost, and offers high intensity. For robustness, metal photocathodes were adopted, including aluminum and magnesium. Ultraviolet light from 255- to 350-nm LEDs (light emitting diodes) stimulated the photoemissions from these photocathodes with an efficiency that is maximized at the low-wavelength end (255 nm) to a value of roughly 10(exp -4). The MXS units now have much higher brightness, are much smaller, and are made using a number of commercially available components, making them extremely inexpensive. In the latest MXS design, UV efficiency is addressed by using a high-gain electron multiplier. The photocathode is vapor-deposited onto the input cone of a Burle Magnum(TradeMark) multiplier. This system yields an extremely robust photon-driven electron source that can tolerate long, weeks or more, exposure to air with negligible degradation. The package is also small. When combined with the electron target, necessary vacuum fittings, and supporting components (but not including LED electronics or high-voltage sources), the entire modulated x-ray source weighs as little as 158 grams.

Gendreau, Keith↗

Improved optical lens system

Objective lens produces a backwardly curving image of a star field that matches the similarly curved surface of the photocathode of an image dissector tube. Lens eliminates the need for a fiber-optics translation between the flat plane image and curved photocathode.

Schmidt, L. F.↗

Advanced infrared photomultiplier

Photocathode for the 8500 angstrom through 9000 angstrom range, improving efficiency by an order of magnitude, is achieved with a gallium arsenide cesium oxide photocathode. Protection of the GaAs surface from contamination during bake-out is another important function.

Sonnenberg, H.↗

Multispectral image dissector camera system

A sensor system which provides registered high-solution multispectral images from a single sensor with no mechanical moving parts is reported, and the operation of an image dissector camera (IDC) is described. An earth scene 100 nautical miles wide is imaged through a single lens onto a photocathode surface containing three spectral filters, thereby producing three separate spectral signatures on the photocathode surface. An electron image is formed, accelerated, focused, and electromagnetically, deflected across an image plane which contains three sampling apertures, behind which are located three electron multipliers. The IDC system uses electromagnetic deflection for cross-track scanning and spacecraft orbit motion for along-track scanning, thus eliminating the need for a mechanical scanning mirror.

Johnson, B. L.↗

Integral image tube-optical systems for the far UV.

Description of proposed image tube optical systems for narrow-band direct photography and broad bandpass photography from spacecraft outside the atmosphere. For narrow-band photography an f/1.5 Schmidt camera with a photocathode located on the focal surface is recommended. The photoelectrons are accelerated and magnetically focused onto a phosphor/fiber optics surface, the curvature of which partially corrects for distortions of the electric field introduced by the curved photocathode. The second stage can be any other tube, electrostatically or magnetically focused, having a fiber optics faceplate butted to the first stage. For broad bandpass a spectrograph with an f/3 all-reflecting Schmidt image tube camera is recommended.

Chincarini, G.↗

Compact photomultiplier housing with controlled cooling.

Description of a compact photomultiplier housing which can provide controlled cooling to the photomultiplier tube down to -90 C. The cooling is accomplished by flowing liquid nitrogen cooled helium gas through a series of coils which envelop the photocathode portion of the tube. The temperature is controlled by controlling the flow of the gas with a fine adjustable needle valve. The temperature is measured near the photocathode of the photomultiplier by a calibrated thermistor.

SHARDANAND↗

A standard for ultraviolet radiation.

Photoemission diode standards for accurately measuring monochromatic ultraviolet light intensity (3000 A-1100 A) are described that are also blind to visible light. The standard uses an opaque photocathode of Cs2Te and is unique because of its combination of thinness (19 mm), high sensitivity, time stability, and uniformity of response. Design criteria, construction methods, and difficulties overcome in obtaining a stable, uniform, high yield photocathode responses are discussed. Cs2Te is discussed in terms of a model for high yield photoemitters.

Fisher, G. B.↗

Environmental test report for the WX-32335 SEC camera tube

The environmental testing activity on the WX-32335 was carried out to determine if this tube type could withstand the environmental requirements established for the International Ultraviolet Explorer (IUE) camera tube (WX-32224). The results of the tests led to the following conclusions: (1) The WX-32335 as processed with a CsTe photocathode surface can withstand the temperature extremes established for the IUE camera tube without damage to the photocathode surface or without introducing background signal in the tube after one hour of dark integration. (2) The WX-32335 built with a WX-32224 type target support structure can withstand the sinusoidal vibration requirements established for the IUE camera tube. (3) Although the vibration test of the WX-32335 type tubes built with the flat target ring structure could not be completed, there was no indication that these tubes could not withstand the sinusoidal vibration requirements established for the IUE camera tube.

Malanoski, R. J.↗

X-ray sensitive oblique imaging device

Instrument employs light reflecting surface (evaporated aluminum coating or minor substrate) behind phosphor screen to improve effective quantum efficiency in dual process: fraction of incoming X-rays are converted to photoelectrons at photocathode; and X-rays that pass through photocathode and thin X-ray transparent membrane enter phosphor screen.

Hallam, K. L.↗

A calibration of detectors and gratings between 100 and 600 Angstroms

Calibration and efficiency measurements of magnetic electron multipliers, diffraction gratings, and photocathodes over the wavelength range 100 to 600 A are reported. For some of the measurements it was found necessary to use the synchrotron radiation from a storage ring. Measurements of grating efficiencies, the polarization produced by diffraction gratings, and the photoelectric yields of various photocathodes are included.

Samson, J. A. R.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

Low-work-function surfaces produced by cesium carbonate decomposition

Cesium carbonate (Cs2CO3) was heated to the decomposition temperature of approximately 600 C. The nonvolatile decomposition products were condensed on a nickel substrate while the carbon dioxide was removed by pumping. The deposited material is characterized by an effective work function of between 1.05 and 1.15 eV at 450 K and by photoemission in the visible and near-infrared region of the spectrum. It is suggested that the deposited material consists of Cs2O, possibly Cs2O2, and adsorbed cesium. Silver, evaporated from a heated silver bead, produced the typical photoemissive and thermionic properties of a silver-oxygen-cesium (S-1) photocathode. The material may be of interest for thermionic energy converters and for the formation of silver-oxygen-cesium photocathodes.

Briere, T. R.↗

Low intensity X-ray and gamma-ray imaging device

A radiation to visible light converter is combined with a visible light intensifier. The converter is a phosphor or scintillator material which is modified to block ambient light. The intensifier includes fiber optics input and output face plates with a photocathode-microchannel plate amplifier-phosphor combination. Incoming radiation is converted to visible light by the converter which is piped into the intensifier by the input fiber optics face plate. The photocathode converts the visible light to electrons which are amplified by a microchannel plate amplifier. The electrons are converted back to light by a phosphor layer and piped out for viewing by the output fiber optics faces plate. The converter-intensifier combination may be further combined with its own radiation source or used with an independent source.

Yin, L. I.↗

High resolution spectrograph for the Space Telescope

The high resolution spectrograph (HRS) for ultraviolet astronomy with the Space Telescope will provide a spectral resolution of approximately 120,000 over a nominal wavelength range of 110-320 nm, together with a spatial resolution of about 0.25 arc seconds. The two detectors will consist of 512-element Digicons with cesium telluride and cesium iodide photocathodes, respectively. Photoelectrons in transit between the photocathodes and the diodes within the Digicons can be deflected in two axes with 12-bit resolution. This feature facilitates a design that emphasizes reliability since (once a hermetic seal is opened in orbit), only two moving parts, a grating carrousel and a shutter, are required for regular operation of the HRS. The instrument will be controlled by a computer in the spacecraft. The scientific objectives of the HRS investigation relate to interstellar matter in our own and nearby galaxies, physical processes of stellar mass loss and mass transfer, chemical abundances, bright quasars and Seyfert galaxy nuclei, and solar system phenomena.

Brandt, J. C.↗

Direct conversion of light to radio frequency energy

A description is presented of the test results obtained with the latest models of the phototron. The phototron was conceived as a replacement for the high voltage solar cell-high power klystron combination for the solar power satellite concept. Physically, the phototron is a cylindrical evacuated glass tube with a photocathode, two grids, and a reflector electrode in a planar configuration. The phototron can be operated either in a biased mode where a low voltage is used to accelerate the electron beam produced by the photocathode or in an unbiased mode referred to as self-oscillation. The device is easily modulated by light input or voltage to broadcast in AM or FM. The range of operation of the present test model phototrons is from 2 to 200 MHz.

Freeman, J. W.↗