Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Passive Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Analysis of Conduction Cooling Strategies for Wire Arc Additive Manufacturing

Metal additive manufacturing (AM) processing consists of numerous parameters which take time to optimize for various geometries. One aspect of the metal AM process that continues to be explored is the control of thermal energy accumulation during component manufacturing due to the melting and solidification of the feedstock. Excessive energy accumulation causes thermal failure of the component while minimal energy accumulation causes lack of fusion with the build plate or previous layer. The ability to simulate the thermal response of an AM component can increase research efficiency by reducing the time to optimize thermal energy accumulation. This paper presents an effective implementation of finite element analysis to determine the thermal response of a wire arc additive manufactured component with various build plate sizes and cooling methods including, integral build plate cooling, oversized build plates with passive cooling, and non-integral build plate cooling. The use of integral build plate cooling channels was shown to decrease the interpass temperature at the conclusion of the build process by 55% and build plate temperature by 96% compared to the conventionally deposited sample with 20 second dwell time. The use of a tall build plate with passive cooling was shown to reduce the interpass temperature by 32% as compared to the conventionally deposited sample with 20 second dwell time. Each cooling strategy evaluated decreased the interpass temperature within a range of 20–55% which enables higher deposition rates and decreased dwell times during depositions. The cooling strategies are designed to be implemented in a hybrid or retrofit AM platform to mitigate concerns of the thermal input from the additive process having detrimental effects on the precision of the machining process. This paper shows that accurate simulations of all strategies can be used to accurately predict the thermal response of the various strategies discussed. These cooling strategies will allow for increased deposition rates with comparable interpass temperature and decreased dwell time, increasing deposition efficiency. This model and these simulations are verified by experimental results. It is concluded that passive strategies, such as the over-sized tall build plate, can be used when liquid coolant in the AM environment could negatively affect the deposition process. Active cooling strategies, such as the integral build plate cooling could be used if low thermal conductivity materials are deposited or higher material deposition rates are desired. This paper discusses the use of active and passive cooling used during AM and shows how a simulation model can be used to make design choices for cooling strategies. The model also enables verification of select critical process parameters such as dwell times for a desired interpass temperature.

Heinrich, Lauren↗

Simulation of the passive condensation cooling tank of the PASCAL test facility using the component thermal-hydraulic analysis code CUPID

For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. In the present study, the CUPID code was applied for the simulation of the PASCAL (PAFS Condensing Heat Removal Assessment Loop) test facility constructed with an aim of validating the cooling and operational performance of the PAFS (Passive Auxiliary Feedwater System). The PAFS is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor +), which is intended to completely replace the conventional active auxiliary feedwater system. This paper presents the preliminary simulation results of the PASCAL facility performed with the CUPID code in order to verify its applicability to the thermal-hydraulic phenomena inside the system. A standalone calculation for the passive condensation cooling tank was performed by imposing a heat source boundary condition and the transient thermal-hydraulic behaviors inside the system, such as the water level, temperature and velocity, were qualitatively investigated. The simulation results verified that the natural circulation and boiling phenomena in the water pool can be well reproduced by the CUPID code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Secondary fuel delivery system

A secondary fuel delivery system for delivering a secondary stream of fuel and/or diluent to a secondary combustion zone located in the transition piece of a combustion engine, downstream of the engine primary combustion region is disclosed. The system includes a manifold formed integral to, and surrounding a portion of, the transition piece, a manifold inlet port, and a collection of injection nozzles. A flowsleeve augments fuel/diluent flow velocity and improves the system cooling effectiveness. Passive cooling elements, including effusion cooling holes located within the transition boundary and thermal-stress-dissipating gaps that resist thermal stress accumulation, provide supplemental heat dissipation in key areas. The system delivers a secondary fuel/diluent mixture to a secondary combustion zone located along the length of the transition piece, while reducing the impact of elevated vibration levels found within the transition piece and avoiding the heat dissipation difficulties often associated with traditional vibration reduction methods.

Parker, David M↗

Manufacturing, Characterization and Terrestrial Passive Radiative Cooling Performance of Nanofibrous PTFR-PEO Composite Thermal Coatings

Passive heat management is desirable in many applications since it can reduce the energy expended for cooling, for example, in buildings and automobiles. Specifically, materials with wavelength-dependent reflectance and emittance can manage incident solar fluxes while enabling passive radiative cooling by thermal emission. This study demonstrates the use of polymeric nanofibers, specifically polytetrafluoroethylene (PTFE) and polyethylene oxide (PEO) composite, as thermal coatings for passive temperature control. Employing the electrospinning fabrication process, we engineer nano and micro-scale fibrous structures, studying the influence of fabrication parameters, such as precursor material concentration and rotating collector speed, on fiber geometry and optical properties. To understand the role of material and fiber geometry on optical performance, we characterize various samples' spectral reflectance, absorptance, and transmittance using spectrophotometers interfaced with integrating spheres. The results show the potential of nanofabricated PTFE-PEO coatings as promising candidates for passive thermal control. We highlight their competitive edge by comparing their solar reflectance and emittance values to existing passive radiative thermal control materials. In essence, this study contributes to advancing passive heat management technologies, offering insights into optimizing material composition and fabrication techniques for enhanced performance in various applications.

Chieloka Ibekwe↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooling Technology for Large Space Telescopes

NASA's New Millennium Program funded an effort to develop a system cooling technology, which is applicable to all future infrared, sub-millimeter and millimeter cryogenic space telescopes. In particular, this technology is necessary for the proposed large space telescope Single Aperture Far-Infrared Telescope (SAFIR) mission. This technology will also enhance the performance and lower the risk and cost for other cryogenic missions. The new paradigm for cooling to low temperatures will involve passive cooling using lightweight deployable membranes that serve both as sunshields and V-groove radiators, in combination with active cooling using mechanical coolers operating down to 4 K. The Cooling Technology for Large Space Telescopes (LST) mission planned to develop and demonstrate a multi-layered sunshield, which is actively cooled by a multi-stage mechanical cryocooler, and further the models and analyses critical to scaling to future missions. The outer four layers of the sunshield cool passively by radiation, while the innermost layer is actively cooled to enable the sunshield to decrease the incident solar irradiance by a factor of more than one million. The cryocooler cools the inner layer of the sunshield to 20 K, and provides cooling to 6 K at a telescope mounting plate. The technology readiness level (TRL) of 7 will be achieved by the active cooling technology following the technology validation flight in Low Earth Orbit. In accordance with the New Millennium charter, tests and modeling are tightly integrated to advance the technology and the flight design for "ST-class" missions. Commercial off-the-shelf engineering analysis products are used to develop validated modeling capabilities to allow the techniques and results from LST to apply to a wide variety of future missions. The LST mission plans to "rewrite the book" on cryo-thermal testing and modeling techniques, and validate modeling techniques to scale to future space telescopes such as SAFIR.

DiPirro, Michael↗

Radiant cooling

Passive radiant cooler design involving patch cone radiative coupling calculation based on specular image technique

Annable, R. V.↗

Performance Analyses of Passive Containment Cooling System for a Concrete Type Containment

The containment of nuclear power plants is the final barrier to keep the radioactive materials from uncontrolled release to the environment. To keep the containment integrity, pressure and temperature must be controlled by the spray system which relies on active components for PWRs with a concrete containment. To achieve a passive means to keep the containment integrity, therefore, cooling should be achieved by forming a natural circulation loop between internal cooling devices connected to an external heat sink. A system like this is often called Passive Containment Cooling System (PCCS). In the early phase of APR-1400 development, this concept was studied and VVER-1200 is also known to adopt the PCCS. The PCCS consists of a cooling device installed at the inside of the containment which is a tube-bank type heat exchanger where cooling occurs at the exterior of the tubes and a heat sink which is called Passive Containment Cooling Tank (PCCT) located at the outside of the containment on the top of the auxiliary building. In this paper, we introduce performance analysis results, utilizing the GOTHIC computer code. The PCCS performance analysis model was developed for APR-1400 which has a thermal power of 4000 MW and considers PCCS as an option to improve its safety characteristics. The PCCS which is considered in this paper is to cope with both Design Basis and Severe Accidents, considering SBO conditions. The pressure and temperature transients due to the Loss of Coolant Accident (LOCA) were analyzed with and without PCCS together with a normal case using the spray system. And, in particular, limitations of the PCCS in regard to mission time will be discussed. Through this study, it was found that the PCCS being considered as an option to improve the safety of APR-1400 can have almost same capability to control the containment pressure for LBLOCA as the containment spray system does. Although it would depends on the heat removal capacity of a given design such as the size of the heat transfer area, the PCCS could even replace the containment spray system. However, the PCCS may lose its capability after 24 hours as its temperature reaches that of the containment atmosphere. To extend the mission time of PCCS, either cooling or supplementary cold water needs to be provided to the external heat sink of PCCS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiative cooling resource maps for the contiguous United States

Passive cooling devices take advantage of the partially transparent properties of the atmosphere in the longwave spectral band from 8 to 13 μ m (the so-called “atmospheric window”) to reject radiation to outer space. Spectrally designed thermophotonic devices have raised substantial attention recently for their potential to provide passive and carbon-free alternatives to air conditioning. However, the level of transparency of the atmospheric window depends on the local content of water vapor in the atmosphere and on the optical depth of clouds in the local sky. Thus, the radiative cooling capacity of solar reflectors not only depends on the optical properties of their surfaces but also on local meteorological conditions. In this work, detailed radiative cooling resource maps for the contiguous United States are presented with the goal of determining the best climates for large-scale deployment of passive radiative cooling technologies. The passive cooling potential is estimated based on ideal optical properties, i.e., zero shortwave absorptance (maximum reflectance) and blackbody longwave emittance. Both annual and season-averaged maps are presented. Daytime and nighttime cooling potential are also computed and compared. The annual average cooling potential over the contiguous United States is 50.5 m -2 . The southwestern United States has the highest annual averaged cooling potential, over 70 W m -2 , due to its dry and mostly clear sky meteorological conditions. The southeastern United States has the lowest potential, around 30 W m -2 , due to frequent humid and/or overcast weather conditions. In the spring and fall months, the Arizona and New Mexico climates provide the highest passive cooling potential, while in the summer months, Nevada and Utah exhibit higher potentials. Passive radiative cooling is primarily effective in the western United States, while it is mostly ineffective in humid and overcast climates elsewhere.

Thermo optic effects↗

Decoupling absorption and radiative cooling in mid-wave infrared bolometric elements

We present a spectrally selective, passively cooled mid-wave infrared bolometric absorber engineered to spatially and spectrally decouple infrared absorption and thermal emission. The structure leverages an antenna-coupled metal–insulator–metal resonance for mid-wave infrared normal incidence photon absorption and a long-wave infrared optical phonon absorption feature, aligned closer to peak room temperature thermal emission. The phonon-mediated resonant absorption enables a strong long-wave infrared thermal emission feature limited to grazing angles, leaving the mid-wave infrared absorption feature undisturbed. The two independently controlled absorption/emission phenomena demonstrate decoupling of the photon detection mechanism from radiative cooling and offer a new design approach enabling ultra-thin, passively cooled mid-wave infrared bolometers.

Ware, Alexander (ORCID:0009000256937727)↗

Highly Integrated THz Receiver Systems for Small Satellite Remote Sensing Applications

We are developing miniaturized, highly integrated Schottky receiver systems suitable for use in CubeSats or other small spacecraft platforms, where state-of-the-art performance and ultra-low mass, power, and volume are required. Current traditional Schottky receivers are too large to employ on a CubeSat. We will develop highly integrated receivers operating from 520-600 GHz and 1040-1200 GHz that are based on state-of-the-art receivers already developed at Jet Propulsion Laboratory (JPL) by using novel 3D multi layer packaging. This process will reduce both mass and volume by more than an order of magnitude, while preserving state-of-the-art noise performance. The resulting receiver systems will have a volume of approximately 25 x 25 x 40 millimeters (mm), a mass of 250 grams (g), and power consumption on the order of of 7 watts (W). Using these techniques, we will also integrate both receivers into a single frame, further reducing mass and volume for applications where dual band operation is advantageous. Additionally, as Schottky receivers offer significant gains in noise performance when cooled to 100 K, we will investigate the improvement gained by passively cooling these receivers. Work by Sierra Lobo Inc., with their Cryo Cube technology development program, offers the possibility of passive cooling to 100 K on CubeSat platforms for 1-unit (1U) sized instruments.

Receiver systems↗

Centaur propellant thermal conditioning system

An upgraded Centaur capability was studied by investigating three main areas: (1) Analytical and experimental investigation of promising capillary pumping concepts for passive cooling of cryogenic capillary acquisition devices resulted in selection, test, and empirical correlation of four wicking configurations. Only plate/screen-screen/plate and plate/screen-plate/screen configurations would function successfully under worst-case Centaur D-1S conditions. Weight estimates were developed for the passively cooled configurations and comparisons were made of passive and actively cooled capillary devices. (2) Thermal subcoolers for replacing pressurization and boost pump systems for three engine candidates and three Centaur D-1S missions were evaluated for several feed system configurations. Analysis included both transient and steady-state operation. Weight comparisons were made among feed system alternatives. (3) Existing experimental mixing studies to destroy thermal stratification were evaluated to determine the best mixing correlation to fit all available data. The correlation was then used to modify a computer program to size thermodynamic vent systems for Shuttle-based Centaur derivatives.

Blatt, M. H.↗

All-day passive radiative cooling using common salts

An infrared transparent foam made from inexpensive salts was developed enabling sub-ambient cooling of underlying surfaces for a full 24 hour cycle. This work showcases how non-convetional materials may be used for passive day-time radiative cooling.

36 MATERIALS SCIENCE↗

James Webb Space Telescope: Large Deployable Cryogenic Telescope in Space

The James Webb Space Telescope (JWST) is an infrared space telescope designed to explore four major science themes: first light and reionization, the assembly of galaxies, the birth of stars and protoplanetary systems, and planetary systems and origins of life. JWST is a segmented architecture telescope with an aperture of 6.6 m. It will operate at cryogenic temperature (40 K), achieved via passive cooling, in an orbit about the Earth-Sun second Lagrange point (L2). Passive cooling is facilitated by means of a large sunshield that provides thermal isolation and protection from direct illumination from the Sun. The large size of the telescope and spacecraft systems require that they are stowed for launch in a configuration that fits the Ariane 5 fairing, and then deployed after launch. Routine wavefront sensing and control measurements are used to achieve phasing of the segmented primary mirror and initial alignment of the telescope. A suite of instruments will provide the capability to observe over a spectral range from 0.6- to 27-micron wavelengths with imaging and spectroscopic configurations. An overview is presented of the architecture and selected optical design features of JWST are described

Lightsey, Paul A.↗

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗