Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single_mu40

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500, 5000 GeV (alternated). Particles are generated using a uniform distribution in Phi and uniform distribution in Eta (pseudorapidity) in the range [-4.5,4.5]. Mixing with pileup: Each event is mixed with pileup using the tool described in arXiv:1510.06638. The pileup events use ATLAS A2 tune (all inelastic, including single and double diffractive events). The CM energy was 14 TeV. Events were generated with PYTHIA8. Events are mixed using a Poisson distribution with the mean mu=40 (average number of MinBias events). Then, only pileup particles around the single pion where taken in the cone 0.1 defined in eta and phi.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single_mu140

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500, 5000 GeV (alternated). Particles are generated using a uniform distribution in Phi and uniform distribution in Eta (pseudorapidity) in the range [-4.5,4.5]. Mixing with pileup: Each event is mixed with pileup using the tool described in arXiv:1510.06638. MinBias events use the ATLAS A2 tune (all inelastic processes, including single and double diffractive events). The CM pp energy was 14 TeV. MinBias events were generated with PYTHIA8. Events are mixed using a Poisson distribution with the mean mu=140 (average number of MinBias events). Then, only pileup particles around the single pion where taken in the cone 0.1 defined in eta and phi.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single_mu200

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500, 5000 GeV (alternated). Particles are generated using a uniform distribution in Phi and uniform distribution in Eta (pseudorapidity) in the range [-4.5,4.5]. Mixing with pileup: Each event is mixed with pileup using the tool described in arXiv:1510.06638. MinBias events use the ATLAS A2 tune (all inelastic processes, including single and double diffractive events). The CM pp energy was 14 TeV. MinBias events were generated with PYTHIA8. Events are mixed using a Poisson distribution with the mean mu=200 (average number of MinBias events). Then, only pileup particles around the single pion where taken in the cone 0.1 defined in eta and phi.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

1 GeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi1gev

Single particle gun for ITK (ATLAS) detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 1 GeV (fixed). Uniform distribution in Phi. Uniform distribution in in the range [-4.5, 4.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

1 TeV pgun collisions, Double particles type, PARTICLE GUN generator: pgun_2pi_angle

Particle gun for detector studies: A particle gun for two pions separated by 0,1,2,..20 degrees in Phi. For every 20th events, the angular separation is reset to 0 degree, for easy tracking. The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in Phi between -PI and PI. This sample has 3 subsamples for 10, 100 and 100 GeV pion energy (fixed). There are 100 files in each sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

1 TeV pgun collisions, Double particles type, PARTICLE GUN generator: pgun_2klong_angle

Particle gun for detector studies: A particle gun for two K-long mesons (KL, PID=130) separated by 0,1,2,..20 degrees in Phi. For every 20th events, the angular separation is reset to 0 degree, for easy tracking. The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in Phi between -PI and PI. This sample has 3 subsamples for 10, 100 and 100 GeV energy (fixed). There are 100 files in each sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

1 TeV pgun collisions, Double particles type, PARTICLE GUN generator: pgun_2klong_angle05

Particle gun for detector studies: A particle gun for two K-long mesons (KL, PID=130) separated by 0.5 degree. For every 20th events, the angular separation is reset to 0 degree, for easy tracking. The maximal separation is 10 degree. The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in Phi between -PI and PI. This sample has 3 subsamples for 10, 100 and 100 GeV energy (fixed). There are 100 files in each sample. The sample was designed for detector studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

32 TeV pgun collisions, Double particles type, PARTICLE GUN generator: pgun_2pions_pi

Particle gun for detector studies: A particle gun for two pions separated by PI in Phi (i.e. back-to-back). The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Charge is alternated. Uniform distribution in Phi between -PI and PI. This sample has several sabsamples with momenta p=2^n GeV, where n=1..15. The energy of each sample is included in the name of files. The sample was designed for detector studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

1 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_eta0_b0

Particle gun for detector studies: A particle gun for single pions and deutrons. The eta and phi is set to 0. Production at (x,y,z,t)=(0,0,0,0). Charge is alternated. The momenta and the particle ID is given in the file name. The full Geant simulation is performed assuming no magnetic field (B=0). The sample is designed for timing studies. Each file has 50k events (only 1 TeV sample will have 10k events). Comment on full simulation: While the baseline detector is SiFcc-7, the B-field for rfull009 tag was set to 0. The sample was designed for calorimeter studies, and we expect that the charged particles entering the calorimeter have exactly eta=phi=0. The sample is designed for timing studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Apparatuses and methods for generating carbon particles and exhaust gas used by gas turbine systems

Apparatuses for generating carbon particles and exhaust gas used by gas turbine systems are disclosed. One apparatus may include a decarbonization component combusting or reacting a mixture of a fuel and a mixing gas to generate the carbon particles and the exhaust gas and an exhaust conduit to receive the exhaust gas generated by the decarbonization component. The apparatus may also include a mixing duct in fluid communication with the exhaust conduit and the gas turbine system. The mixing duct may receive the exhaust gas and provide the exhaust gas to the gas turbine system to be used to produce a working fluid within the gas turbine system. The apparatus may further include a carbon particle collection component for receiving and storing the generated carbon particles.

Berry, Jonathan Dwight↗

Production of an Associated Particle Neutron Generator with ZnO:Ga Alpha-Detector

An associated particle neutron generator (APNG) capable of 109 neutrons per second has been operated with an alpha particle detector made of a ZnO:Ga phosphor with decay time of approximately 1 ns. Fast 14.1 MeV neutrons and 3.5 MeV alpha particles are produced through deuterium-tritium (DT) fusion reactions and travel in opposite directions to conserve momentum. The neutron generator provides high-rate capability, excellent subnanosecond time resolution (< 0.7 ns), and a large solid angle with acceptance of 8%. The alpha detector was found to have a detection efficiency of 88% using a Burle 8850 bialkali photocathode. The DT beam spot diameter was measured down to 2.1 mm with the possibility of achieving 1 mm if desired. An opaque aperture was placed on the alpha detector and the neutron beam was obstructed using various amounts of lead shielding in an effort to study the generator s imaging contrast capability for neutron radiography. The alpha detector can be pixilated using a multianode photomultiplier tube to deliver imaging capability and to enhance the signal to noise ratio. Due to its ability to suppress background, the developed APNG is to be used to search cargo containers for illicit special nuclear materials, using as a trigger prompt fission gamma ray in coincidence with an alpha particle within a 10 ns gate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma Processing of SRF Cavities for the next Generation Of Particle Accelerators

The cost-effective production of high frequency accelerating fields are the foundation for the next generation of particle accelerators. The Ar/Cl2 plasma etching technology holds the promise to yield a major reduction in cavity preparation costs. Plasma-based dry niobium surface treatment provides an excellent opportunity to remove bulk niobium, eliminate surface imperfections, increase cavity quality factor, and bring accelerating fields to higher levels. At the same time, the developed technology will be more environmentally friendly than the hydrogen fluoride-based wet etching technology. Plasma etching of inner surfaces of standard multi-cell SRF cavities is the main goal of this research in order to eliminate contaminants, including niobium oxides, in the penetration depth region. Successful plasma processing of multi-cell cavities will establish this method as a viable technique in the quest for more efficient components of next generation particle accelerators. In this project the single-cell pill box cavity plasma etching system is developed and etching conditions are determined. An actual single cell SRF cavity (1497 MHz) is plasma etched based on the pill box cavity results. The first RF test of this plasma etched cavity at cryogenic temperature is obtained. The system can also be used for other surface modifications, including tailoring niobium surface properties, surface passivation or nitriding for better performance of SRF cavities. The results of this plasma processing technology may be applied to most of the current SRF cavity fabrication projects. In the course of this project it has been demonstrated that a capacitively coupled radio-frequency discharge can be successfully used for etching curved niobium surfaces, in particular the inner walls of SRF cavities. The results could also be applicable to the inner or concave surfaces of any 3D structure other than an SRF cavity.

43 PARTICLE ACCELERATORS↗

Tracking Synthetic Particle Paths Generated in GATE with Multi-Positron Emission Particle Tracking (MPEPT)

Multi-Positron Emission Particle Tracking (MPEPT) is able to reconstruct the position of point-sources in a PET scanner to a high degree of accuracy. Experimental and simulated trajectories of activated point-sources are compared herein to validate the GATE model of our PET scanner, and test MPEPT performance. The trajectory followed by one point-source of activity 370000 Bq is simulated in GATE, and experimentally measured for velocities 0.18, 0.22. and 0.45 cm/s moving along the major axis of the detector bore. The average difference between the prescribed and predicted point-source positions is found to be approximately 0.3 mm. However, the number of Lines of Response (LOR) reported by GATE for the 370000 Bq source is larger than the number of LOR measured in the experiments. Additional testing of the accuracy of MPEPT is provided by the simulation of 20 point-sources of 20 Bq each placed around the surface of a sphere of radius 40 mm and moving radially inward to a radius of 20 mm at a constant velocity of 1 E-6 m/s. Point-source trajectories for the GATE simulation are compared to trajectories reconstructed from the GATE generated LOR using MPEPT. The average difference between prescribed and predicted point-source position is found to be approximately 0.72 mm. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500 , 5000 GeV (alternated). Uniform distribution in Phi. Uniform distribution in in the range [-4.5, 4.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

10 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_1to10000gev

Single particle gun for detector studies: A particle gun with single pions. One pion per event. 5000 events per file, 50 files per sample. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pi is 1 , 10, 100, 1000, 10000 GeV. Uniform distribution in Phi. Uniform distribution in the Eta (pseudorapidity) range [-4.5, 4.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗