Particle Detectors and Data Analysis for Cusp Transient Features Campaign

On December 3, 1997, a rocket payload (36.152) was launched from N(sub y) Alesund into the dark cusp at 0906:00 U (1206:00 LT) during an interval of southward B(sub z) and positive B(sub y). Launch occurred during a time interval of northeastward moving auroral forms observed between 0845 and 0945 UT by ground-based meridian scanning photometers. Ground photometric measurements during the flight show that the payload passed over the poleward portion of the most intense 6300 A emissions of the dayside cusp/cleft region. Electrons of energy up to a few hundred eV were detected immediately upon instrument turn-on at an altitude of 205 km and throughout the flight until the payload reached an altitude of -197 km on the downleg. Electron spectra were either quasithermal with peak energies -100 eV or showed evidence of acceleration along the magnetic field line by potentials of 100-200 V. Precipitating ions were observed throughout much of the flight. Their spectra were broadly peaked in energy with the peak energy decreasing from -500 eV to -250 eV as the payload flew approximately westward over the dayside precipitation region. Structure (spatial or temporal intensity variation) was observed between T + 180 s and T + -400 s. At the rocket altitudes (<450 km) the ions were observed to be precipitating. During the flight, the DMSP F-13 satellite passed through the all-sky imager field-of-view just poleward of the brightest dayside emissions enabling the identification of plasma sheet and boundary layer regions along the orbit. We thus conclude that particle fluxes detected by the rocket flight were either cusp plasma or boundary layer/mantle plasma just poleward of the dayside cusp/cleft. A paper describing the fields and plasmas observed during the flight is now being prepared for publication.

Sharber, James R.↗

Particle Detectors and Data Analysis for Cusp Transient Features Campaign

On December 3, 1997, a rocket payload (36.152) was launched from Ny Alesund into the dark cusp at 0906:00 U (1206:00 LT) during an interval of southward B(sub Z), and positive B(sub y). Launch occurred during a time interval of northeastward moving auroral forms observed between 0845 and 0945 UT by ground-based meridian scanning photometers. Ground photometric measurements during the flight show that the payload passed over the poleward portion of the most intense 6300 A emissions of the dayside cusp/cleft region. Electrons of energy up to a few hundred eV were detected immediately upon instrument turn-on at an altitude of 205 km and throughout the flight until the payload reached an altitude of approximately 197 km on the downleg. Electron spectra were either quasithermal with peak energies approximately 100 eV or showed evidence of acceleration along the magnetic field line by potentials of 100-200 V. Precipitating ions were observed throughout much of the flight. Their spectra were broadly peaked in energy with the peak energy decreasing from approximately 500 eV to approximately 250 eV as the payload flew approximately westward over the dayside precipitationregion. Structure(spatial or temporal intensity variation) was observed between T + 180 s and T + approximately 400 s. At the rocket altitudes(less than 450km) the ions were observed to be precipitating. During the flight, the DMSPF-13 satellite passed through the all-sky imager field-of-view just poleward of the brightest dayside emissions enabling the identification of plasma sheet and boundary layer regions along the orbit. We thus conclude that particle fluxes detected by the rocket flight were either cusp plasma or boundary layer/mantle plasmajust poleward of the dayside cusp/cleft. Further investigation of the particle characteristics and their relationship to ionospheric convection patterns is continuing.

Sharber, James R.↗

An in-situ movable calibration source for cryogenic particle detectors

A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for cryogenic dark matter detectors. Data taken by scanning a calibration source across multiple radial positions of a prototype dark matter detector demonstrated its functionality. Construction, heat load, and operation of the device are discussed, as is the effect of the motor on the detector operation. A sample dataset taken over multiple positions of a SuperCDMS detector is presented as an example of the utility of such a device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

First operation of superconducting quantum bits as particle detectors

Transmon qubits are among the leading technologies for the development of future quantum computers. However these superconducting devices are sensitive to ionizing radiation, which reduces their coherence time and leads to correlated errors. This study represents the first quantitative estimation of cosmic rays and ambient radiation impact on transmon qubits. In the shielded underground facility at the Laboratori Nazionali del Gran Sasso (LNGS), errors induced by the interaction of a radioactive source were reconstructed with an efficiency of about 10%. In contrast, in the unshielded above-ground facility at the Fermi National Accelerator Laboratory (FNAL), cosmic and ambient radiation impacts were detected with an efficiency ranging from 10% to 20% by modifying the acquisition protocol. Lastly, the simultaneous readout of three transmons in coincidence was demonstrated, achieving an event reconstruction efficiency of 90% when the devices were illuminated with an LED.

Bonomo, Camilla [Rome U.; INFN, Rome]↗

SOFT PARTICLE DETECTORS

Gas-filled proportional counter for photon detection in the .1-20 kev range

PROPORTIONAL COUNTER↗

Improved channel multiplier for radiation-and-particle detectors

Multiplier is formed of glass and includes cylindrically-shaped main channel element having length-to-diameter ratio of 50 to 1. Element has open slot along its length. Attached to slot edges are two glass plates set at an angle to each other. Inside surfaces are coated with secondary electron emissive coating.

Schmidt, K. C.↗

Sheath effects on current collection by particle detectors with narrow acceptance angles

Restriction of the aperture acceptance angle of an ion or electron trap on an attracting spacecraft significantly alters the volt-ampere characteristics of the instrument in a low Mach number plasma. It is shown when the angular acceptance of the aperture is restricted the current to the collector tends to be independent of the Debye length. Expressions for the RPA characteristics for both a thin sheath and a thick sheath are derived; and it is shown that as the aperture is narrowed the curves tend toward equivalence.

Singh, N.↗

H Ly-alpha transmittance of thin foils of C, Si/C, and Al/C for keV particle detectors

A class of instruments designed for remote sensing of space plasmas by measuring energetic neutral atoms (ENA) uses a thin foil as both a signal generator and a light shield. An ENA imager must look directly at the ENA source region, which is also usually an intense source of H Ly-alpha (1216 A) photons. It is desirable to minimize the energy threshold for ENA detectors, at the same time maximizing the blocking of H Ly-alpha. Optimizing filter design to meet these two contrary requirements has led us to measure the transmittance of thin C, Si/C, and Al/C foils at H Ly-alpha. Our results indicate that (1) transmittance of less than 0.0007 can be achieved with 7 micro-g/sq cm Si on 1.7 micro-g/sq cm C; (2) an Si/C composite foil with a thin carbon layer is more effective in blocking UV radiation while having the lowest energy threshold of all the foils measured; and (3) transmittance of Si/C foils of known Si and C thicknesses cannot be accurately predicted, but must be measured.

Drake, V. A.↗

Development of a Charged Particle Detector for Windborne Martian Dust

A prototype of an aerodynamic electrometer to measure the electrostatic properties of Martian atmospheric dust has been constructed. The instrument will enable a more thorough understanding of the potential for electrostatic discharge of different materials on Mars. Additional information is contained in the original extended abstract.

Calle, C. I.↗