Bearing Tester Data Compilation Analysis, and Reporting and Bearing Math Modeling
The magnitude and direction of fluid induced torques and forces on the 57 mm bearing cage is considered to be a contributing factor in possible cage instabilities that can produce intermittent high heating in the bearing. Analyses of the fluid forces and torques are presented. Heat generated by viscous fluid work was estimated for two flow diverter configurations and a coolant flow of 10 lbs/sec to support the thermal evaluation of the LOX Bearing Materials Tester. Results of the analysis of the LOX turbopump turbine end bearings are discussed. Coolant velocities for the no. 4 LOX turbopump turbine end bearings were estimated as a function of shaft speed and coolant flow rate. Contact angles and track width data were developed for the 57 mm bearing as functions of shaft speed, and axial and radial loads. The Advanced Dynamics of Rolling Elements (ADORE) computer program was installed on the MSFC UNIVAC 1100 and a test case successfully run. Both the text output and the plotting output were verified. The Bearing Seal and Materials Tester - Test Condition Data Base was developed. The parametric analysis of the operating characteristics of the LOX turbopump pump end bearing using the 45 mm bearing thermal model was begun.