Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PYROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Plenoptic Multi-Color Imaging Pyrometer

A three-color pyrometer has been developed based on plenoptic imaging technology. Three bandpass filters placed in front of a camera lens allow separate 2D images to be obtained on a single image sensor at three different and adjustable wavelengths selected by the user. Images were obtained of different black- or grey-bodies including a calibration furnace, a radiation heater, and a luminous sulfur match flame. The images obtained of the calibration furnace and radiation heater were processed to determine 2D temperature distributions. Calibration results in the furnace showed that the instrument can measure temperature with an accuracy and precision of 10 Kelvins between 1100 and 1350 K. Time-resolved 2D temperature measurements of the radiation heater are shown.

Danehy, Paul M.

Detection of effect of deposits on optical windows of pyrometer measurements

Temperatures measurements in an enclosed test chamber are more accurate when the reflectivity of the inner coated surface is compared to the outer clean surface of an optical window. Temperature readings are corrected by correlating the reflectivity of the deposits with their effect on the temperature measurement.

Cipolone, P.

Pyrometer for measurement of surface temperature distribution on a rotating turbine blade

A conceptual optical method and some test results are presented for measuring the surface temperature distribution on one of the rotating turbine blades with a surface resolution of 0.05 cm spot diameter at a tip speed of 400 m/sec. The blade is scanned line-by-line by a fixed optical system. During each line-scan, the detector analog output signal is converted to two hundred consecutive digital values that are temporarily stored in a high speed buffer memory, and then transferred at a slower rate to a computer for processing. The signal-to-noise ratio of the silicon avalanche detector is large enough to obtain an accuracy of one percent at 1050 K blade temperature. By averaging 25 scans of the same line the same accuracy can be obtained at 900 K.

Buchele, D. R.

Pyrometer for measurement of surface temperature distribution on a rotating turbine blade.

A conceptual optical method and some test results are presented for measuring the surface temperature distribution on one of the rotating turbine blades with a surface resolution of 0.05 cm spot diameter at a tip speed of 400 m/sec. The blade is scanned line-by-line by a fixed optical system. During each line-scan, the detector analog output signal is converted to 200 consecutive digital values that are temporarily stored in a high-speed buffer memory and then transferred at a slower rate to a computer for processing. The signal-to-noise ratio of the silicon avalanche detector is large enough to obtain an accuracy of 1% at 1050 K blade temperature. By averaging 25 scans of the same line the same accuracy can be obtained at 900 K.

Buchele, D. R.

Radiation pyrometer for gas turbine blades

A turbine blade temperature measuring system for liquid oxygen turbopumps is reported. The system includes a three mode, two-input optical signal processor, interconnecting cable, and four sensor heads. Two of the heads are aperture type, while the other two are lens type. This system is applicable to a temperature range of 1400 to 2200 F.

Rohy, D. A.

Multiwavelength pyrometer for gray and non-gray surfaces in the presence of interfering radiation

A method and apparatus for detecting the temperature of gray and non-gray bodies in the presence of interfering radiation are presented. A gray body has a constant emissivity less than 1 and a non-gray body has an emissivity which varies with wavelength. The emissivity and reflectivity of the surface is determined over a range of wavelengths. Spectra are also measured of the extraneous interference radiation source and the surface of the object to be measured in the presence of the extraneous interference radiation source. An auxiliary radiation source is used to determine the reflectivity of the surface and also the emissivity. The measured spectrum of the surfaces in the presence of the extraneous interference radiation source is set equal to the emissivity of the surface multiplied by a Planck function containing a temperature term T plus the surface reflectivity multiplied by the spectrum of the extraneous interference radiation source. The equation is then solved for T to determine the temperature of the surface.

Ng, Daniel L. P.

Noncontact temperature pattern measuring device

Laser pyrometer techniques are utilized to accurately image a true temperature distribution on a given target without touching the target and without knowing the localized emissivity of the target. The pyrometer utilizes a very high definition laser beam and photodetector, both having a very narrow focus. The pyrometer is mounted in a mechanism designed to permit the pyrometer to be aimed and focused at precise localized points on the target surface. The pyrometer is swept over the surface area to be imaged, temperature measurements being taken at each point of focus.

Elleman, Daniel D.

Noncontact measurement of high temperature using optical fiber sensors

The primary goal of this research program was the investigation and application of noncontact temperature measurement techniques using optical techniques and optical fiber methods. In particular, a pyrometer utilizing an infrared optical light pipe and a multiwavelength filtering approach was designed, revised, and tested. This work was motivated by the need to measure the temperatures of small metallic pellets (approximately 3 mm diameter) in free fall at the Microgravity Materials Processing Drop Tube at NASA Marshall Space Flight Center. In addition, research under this program investigated the adaptation of holography technology to optical fiber sensors, and also examined the use of rare-earth dopants in optical fibers for use in measuring temperature. The pyrometer development effort involved both theoretical analysis and experimental tests. For the analysis, a mathematical model based on radiative transfer principles was derived. Key parameter values representative of the drop tube system, such as particle size, tube diameter and length, and particle temperature, were used to determine an estimate of the radiant flux that will be incident on the face of an optical fiber or light pipe used to collect radiation from the incandescent falling particle. An extension of this work examined the advantage of inclining or tilting the collecting fiber to increase the time that the falling particle remains in the fiber field-of-view. Those results indicate that increases in total power collected of about 15 percent may be realized by tilting the fiber. In order to determine the suitability of alternative light pipes and optical fibers, and experimental set-up for measuring the transmittance and insertion loss of infrared fibers considered for use in the pyrometer was assembled. A zirconium fluoride optical fiber and several bundles of hollow core fiber of varying diameters were tested. A prototype two-color pyrometer was assembled and tested at Virginia Tech, and then tested on the Drop Tube at Marshall Space Flight Center. Radiation from 5 mm diameter niobium drops falling in the Drop Tube was successfully detected, and recorded for later analysis. Subsequent analysis indicated that the imaging of light output from the light pipe onto the detector active areas was not identical for both detectors.

Claus, R. O.

Correction-free pyrometry in radiant wall furnaces

A specular, spherical, or near-spherical target is located within a furnace having inner walls and a viewing window. A pyrometer located outside the furnace 'views' the target through pyrometer optics and the window, and it is positioned so that its detector sees only the image of the viewing window on the target. Since this image is free of any image of the furnace walls, it is free from wall radiance, and correction-free target radiance is obtained. The pyrometer location is determined through a nonparaxial optical analysis employing differential optical ray tracing methods to derive a series of exact relations for the image location.

Thomas, Andrew S. W.

On-Line, Real-Time Diagnostics of a Single Fluid Atomization System

A drop tube-Impulse Atomization technique was used to produce copper droplets. In this method, energy is transferred to a liquid by plunger movement resulting in spherical droplets emanating from orifices. A mathematical model of the evolution of droplet velocity and temperature at various heights for different sized droplets was developed. A two-color pyrometer, DPV-2000, and a shadowgraph were used to measure droplets radiant energy, diameter and velocity. The temperature values from the model were used to assess the two color pyrometer assumption over the temperature range of measurement. The DVP 2000 measurements were found to be dependent of droplet size wavelength and position of droplets below the atomizing nozzle. By calibrating the instrument for effective emissivity over the range of measurements, the thermal history of droplets may be recorded using a single color pyrometer approach.

DelshadKhatibi, P.

Infrared Thermometer Instrument Handbook

The infrared thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the brightness temperature of the scene in its field of view. The ground IRT (sometimes referred to as the upwelling instrument) lens has a wide field of view for measuring the radiating temperature of the ground surface. It measures in a narrow range of the infrared band, details of which can be found in Table 2. It provides data to the user averaged to 1-minute resolution. The infrared thermometer for sea-surface temperature (IRTSST) is a ship-based radiation pyrometer that provides measurements of the temperature of the sea surface. The upwelling infrared emission is determined with two different IRTs for over-ocean field campaigns and the data is at 1-second temporal resolution. The IRTs are mounted at heights varying between 2 and 42 m above the ground, oriented so the mounting platform and other human made objects are not in the field of view, and also to ensure that the ground and vegetation cover are representative of the local area. The Heitronics IRT is generally mounted inside a small enclosure, and the Apogee IRT is shielded by a cylindrical enclosure that is part of the design from the manufacturer.

47 OTHER INSTRUMENTATION

Ignition phenomena of bulk aluminum alloy as a function of oxygen pressure

An ignition phenomena of 6061 aluminum alloy was investigated as a function of oxygen pressure. Cylindrical aluminum alloy specimens were ignited in a pure oxygen environment by a focused CW CO2 laser beam. The experiments were conducted at oxygen pressures ranging from 0.084 to 2.413 MPa. The temperature history of the entire upper surface of the specimen and of a 0.5 mm diameter spot located initially at the center of the specimen top surface was recorded by using a commercial two-color ratio pyrometer and a fast-response, narrow-band, two-color pyrometer. Mass, brightness, and interior temperatures (for certain experiments) were also recorded throughout the experiment. The results show that the surface temperatures at ignition of the alloy obtained from the temperature curves are below the melting temperature of the aluminum oxide and are slightly dependent on oxygen pressure. The data indicate that the ignition mechanism is complex and probably composed of several phenomena acting both separately and in conjunction with each other.

Nguyen, K.

Fast optical pyrometry

Design and operation of accurate millisecond and microsecond resolution optical pyrometers developed at the National Bureau of Standards during the last two decades are described. Results of tests are presented and estimates of uncertainties in temperature measurements are given. Calibration methods are discussed and examples of applications of fast pyrometry are given. Ongoing research in developing fast multiwavelength and spatial scanning pyrometers are summarized.

Cezairliyan, Ared