At least 73 records · Page 4

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗

PV Module Operating Temperature - Data and Resources

The Photovoltaic Systems Evaluation Laboratory (PSEL) at Sandia National Laboratories (SNL) in Albuquerque, NM has an extensive test site where PV modules and other system components are deployed and monitored for testing and evaluation. For this dataset PV Performance Labs has assembled one year of measurements from the Systems Long-Term Evaluation (SLTE) project (formerly known as PV Lifetime) providing the main variables needed to investigate and validate PV module operating temperature models: irradiance, ambient temperature, wind speed and back-of-module temperature. For use with more advanced thermal modeling, an estimate of down-welling long-wave radiation is also included.

14 SOLAR ENERGY↗

Cyber-physical security framework for Photovoltaic Farms

With the evolution of PV converters, a growing number of vulnerabilities in PV farms are exposing to cyber threats. To mitigate the influence of cyber-attack on PV farms, it is necessary to study attacks' impact and propose detection methods. To meet this requirement, a cyber-physical security framework is proposed for PV farms. Data integrity attacks (DIAs) are studied on different control loops. As μPMU is gaining in popularity, a lower sampling rate of μPMU data is applied to develop a detection algorithm. We have evaluated two data-driven methods, which are support vector machine (SVM) and long short-term memory (LSTM). Lastly, the data-driven methods verify the feasibility of μPMU data in attack detection.

Attack Impact Analysis↗

Techno-economic Analysis of Novel PV Plant Designs for Extreme Cost Reductions

A techno-economic analysis is underway examining the cost and performance of future large-scale photovoltaic (PV) plant components, including bifacial modules, tandem modules, increased plant voltage architectures, and module-level power electronics. Integration of these components into PV plant designs is compared with current PV technologies based on levelized cost of electricity (LCOE). Baseline models are developed and validated against recorded PV plant performance data. Expected cost and performance data of future PV technologies are incorporated into the baseline models. An evolutionary algorithm is utilized to optimize PV plant configuration, technology combination, and LCOE. This paper focuses on the bifacial module analysis.

14 SOLAR ENERGY↗

GET-Solar (Generation forecasting and parameter Estimation Tool for Solar) [SWR-20-115]

GET-Solar (Generation forecasting and parameter Estimation Tool for Solar) can be used to estimate behind the meter (BTM) solar generation from limited datasets. Using distributed sets of diverse solar sites, but with close spatial proximity, and/or limited historical PV generation information can be used to generate of solar profiles. This is useful for applications where partial solar generation data is available, and on-site irradiance data is not available. GET-Solar calculates PV technical data parameters and calculates output by modeling shading and cloud cover impacts. Clear sky irradiance profiles are used to calculate base generation profiles on which the local shading and cloud cover layers are added. In order to arrive at clear sky generation data, PV mounting information like panel tilt and and angle is needed. For cases where PV mounting information is missing, panel tilt and azimuth angle can be estimated using a non-linear optimization algorithm. GET-Solar can also be used for forecasting applications where historical PV data is available to estimate local shading at various solar positions. This overall framework can be used for estimation of solar parameters, and assisting in analyzing and modeling diverse sets of DER where solar generation is also present in utility meter data. GET-Solar has been developed in Python and uses the Pyomo optimization language.

Abraham, Sherin Ann↗

Availability and Performance Loss Factors for U.S. PV Fleet Systems

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data and publish aggregated, anonymized results. This report is an update of our previous publications, specifically a FY 2021 performance index publication and a FY 2022 fleet degradation analysis. In this analysis, we have increased our data participants and system totals by around 10% to 8.5 GW and 24,000 separate inverter data channels. Four major analysis topics are considered in this report: Performance Index (PI) trends, PV system availability, soiling losses, and PV system degradation. Performance Index and inverter availability are assessed on a larger set of data from our FY 2021 report: 1,128 systems compared with 200 systems from before. The increased number of systems is due to an improved data quality methodology, as well as introducing new systems to the analysis. Overall results are similar to previously published values - overall inverter availability is low in the first six months of system performance before reaching steady-state by the end of the first year. Excluding this six-month startup period, system-level aggregated data shows a median (P50) system availability of 0.99 and a lower 10th percentile (P90) value of 0.95 (Figure ES-1). A dependence on system size is also demonstrated, with worse inverter availability results for larger PV systems. Causes of this effect are under investigation, but may be impacted by inverter size, which also show lower availability for larger inverter sizes. This report also investigates PI, correcting for degradation, soiling, snow, and availability. Following these corrections, the median system PI over its entire lifetime is 0.95. PI values reported here are approximately 3% lower than what we presented in our previous FY 2021 report. Soiling loss is assessed in a comprehensive way for the first time in this report. Results are presented using the COmbined Degradation and Soiling (CODS) method, as implemented in RdTools (v3.0.0a4). Soiling values are presented for 255 systems, which indicated irradiance-weighted soiling loss greater than 1%. The values have been published in an updated NREL soiling map at nrel.gov/pv/soiling.html. Finally, we investigated system degradation using three different data analysis techniques: conventional RdTools (year-on-year (YOY)), CODS, and Performance Loss Rate (PLR) analysis. Overall degradation results are consistent with our previous publications. Rerunning conventional RdTools on our updated fleet shows that some data partners have systematically fallen below the median system degradation rate (change over time) of -0.75 %/year. A comparison with PLR analysis, which looks at change in annual PI over time, shows that median system degradation is consistent with -0.5% to -0.75% per year change. However, at the P90 value, system degradation is substantially faster. These two results are consistent and indicate that resulting degradation statistics depend to a great degree on the population of PV systems making up the analysis cohort and whether soiling impacts the systems. The use of CODS for degradation analysis provides a different method for degradation assessment, which explicitly excludes the impact of recoverable soiling on degradation analysis. Excluding soiling effects yields an annual system degradation around -0.5% per year on average. This indicates that a portion of system performance loss may be attributed to periodic soiling that is not fully recovered. This report provides PV system owners/operators with background and methods to analyze PV system performance, give guidance for expected cohort performance, and performance loss values for use in pro-forma financial models, which guide new-build system design and bankability reports.

14 SOLAR ENERGY↗

PV Inverter Availability from the U.S. PV Fleet

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with better inverter availability results for smaller PV systems. Potential causes of this effect may include the selection of inverter itself: smaller inverters 6kW-250kW showed better average availability than inverters 300kW-5MW. The elimination of string combiner boxes and lower energy impact when one particular inverter goes off-line are potential benefits of a string inverter-based PV system architecture. DNV also analyzed availability data from over 1100 operating systems and found similar trends. DNV's P50 industry guidance on expected availability has been updated to reflect the data and the following observations: utility scale systems have lower availability than DG systems, availability is lower in first year compared to subsequent years, and that actual availability is lower than expected.

fleet↗

Data Analytics for Residential PV from Permit to Interconnect (Final Technical Report)

The main objective of this research is to provide novel insights into the effects of permitting, inspection, and interconnection (PII) processes on PV system installations—and in particular, into the relationship between PII processes and adoption timelines. This research can then be used to clarify the potential effect of various process changes on reducing PII timelines, customer cancellation rates, and related costs nationwide. NREL completed this research by assembling a data set of distributed, largely residential rooftop solar systems less than 50 kilowatts in size from participating solar installers. NREL produced five publications describing the effects that PII processes can have on adoption timelines nationwide, in addition to publishing an interactive data viewer with five years of PII cycle time data. This tool can be used by stakeholders to identify potential adoption timelines by local government.

14 SOLAR ENERGY↗

PV System Availability from Commercial and Utility-Scale Systems [Slides]

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with worse inverter availability results for larger PV systems. Potential causes of this effect are under investigation.

14 SOLAR ENERGY↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Using Current Data to Detect Hardware Faults at Solar Plants

Monitoring amperage data is an effective means of detecting faults in PV plant data. Utilizing amperage data collected at the combiner box gives plant operators an up-to-date list of faulted equipment, allowing them to coordinate maintenance needs at much shorter intervals than previously. Shorter maintenance intervals will increase PV plant production levels, narrowing the gap between expected and actual PV plant performance. The amperage monitoring method performs at a high level, with a string-outage related fault detection True Positive Rate of 46% and False Positive Rate of 8%.

14 SOLAR ENERGY↗

Review of Technical Photovoltaic Key Performance Indicators and the Importance of Data Quality Routines

Technical key performance indicators (KPIs) are important metrics used to assess and quantitatively summarize various aspects of photovoltaic (PV) systems, including long-term performance, economic viability, and carbon footprint. Herein, a group of experts of the International Energy Agency's Photovoltaic Power Systems Programme Task 13 collect and describ the most important technical KPIs used in the industry. Thereby, a set of best practices for reliably handling PV system data is presented and the impact of data quality and climatic variability on KPI calculation is investigated. Further, the effective use of technical KPIs allows triggering data-driven and informed decisions to optimize PV systems and providing a comprehensive overview of how PV systems operate across different conditions and climates. With the worldwide growth of the PV industry, more companies operate/own PV systems in different regions, where the climatic and seasonal profiles differ. This requires context-aware evaluation of KPIs, or the judicious application of multiple KPIs, to ensure that each asset is evaluated correctly. Beyond that, there is untapped potential in the utilization of KPIs through geospatial mapping and extrapolation of fleet KPIs. This study demonstrates that the uncertainty in KPI estimation is not well understood and depends on data quality, climatic variability, and system configuration.

14 SOLAR ENERGY↗

Data-Driven Day-Ahead PV Estimation Using Autoencoder-LSTM and Persistence Model

Inherent variability in photovoltaic (PV) and associated impacts on power systems is a challenging problem for both the PV owners and the grid operators. Existing statistical and machine learning algorithms typically work well for weather conditions similar to historical data. Furthermore, uncertain weather conditions pose a great challenge to the estimation accuracy of the estimation models. With the enhanced integration of intelligent electronic devices and the realization of associated automation in the power grid, renewable energy data is becoming more accessible, which can be utilized by deep learning models and improve the PV power generation estimation accuracy. In this paper, a hybrid deep learning model driven by external weather data is proposed to do day-ahead PV output forecasting at 15-minute-interval. The proposed model is motivated by the recent advancement of Long-Short-Term-Memory (LSTM) networks and AutoEncoder (AE), which estimates uncertainties in sequence while making the prediction for complex weather conditions. Meanwhile, the persistence model (PM) is used to predict continuous sunny weather conditions. The forecasting result is validated with data from multiple locations

42 ENGINEERING↗

Data-Driven Distribution System Coordinated PV Inverter Control Using Deep Reinforcement Learning

The deployment of distributed solar photovoltaic (PV) systems has increased consistently over the past decades. High penetrations of PVs could cause a series of adverse grid impacts, such as voltage violations. The recent development of smart inverter technologies rises the incentives of developing PV control solutions that regulate the inverter output power and seeking the optimization on system operational objectives. This paper proposes a data-driven control solution based on deep reinforcement learning (DRL) to optimize PV inverters for voltage regulation. The proposed solution can minimize PV real power curtailment while maintaining network voltage at an acceptable range. Comparison results between the proposed DRL control algorithms with deep deterministic policy gradient (DDPG) and volt-var control on a real feeder in west Colorado highlight the advantage of the proposed framework in controlling the system voltage while minimizing the PV real power curtailment.

deep reinforcement learning↗

Reliability Assessment of Cooling Fans for PV Inverters: Testing, Modeling, and Case Studies

The reliability of photovoltaic (PV) inverters is critical for long-term solar system performance, with cooling fan failures frequently leading to costly downtime. While much research exists on general cooling fan reliability, little attention has been given to fans operating within PV inverters and their unique environmental challenges. Here, this article proposes a comprehensive methodology to address this gap. First, a failure mode and effects analysis is performed on fans to identify the key failure mechanisms in PV applications, their corresponding stressors, and the models necessary for lifetime prediction. Second, an accelerated life test is designed and conducted to collect valuable experimental data for PV inverter fans in a reasonable amount of time. Third, a mathematical conversion of dynamic mission profiles into effective constant stress levels is derived. Fourth, case studies are given, showcasing lifetime estimates that account for geographic variations in mission profile data. The results demonstrate that this integrated approach leads to an accurate reliability assessment for PV inverter cooling fans.

accelerated life testing (ALT)↗

Digital Twin Empowered PV Power Prediction

The accurate prediction of photovoltaic (PV) power generation is significant to ensure the economic and safe operation of power systems. To this end, the paper proposes a new digital twin (DT) empowered PV power prediction framework that is capable of ensuring reliable data transmission and employing the DT to achieve high accuracy of power prediction. With this framework, considering potential data contamination in the collected PV data, a generative adversarial network is employed to restore the historical data set, which offers a prerequisite to ensure accurate mapping from the physical space to the digital space. Further, a new DT empowered PV power prediction method is proposed. Therein, we model a DT that encompasses a digital physical model for reflecting the physical operation mechanism and a neural network model (i.e., a parallel network of convolution and bidirectional long-short-term memory model) for capturing the hidden spatial-temporal features. The proposed method enables the use of the DT to take advantages of the digital physical model and the neural network model, resulting in enhanced prediction accuracy. Finally, a real data set is conducted to access the effectiveness of the proposed method.

14 SOLAR ENERGY↗