Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRINCIPAL COMPONENT ANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Revisiting AVHRR Tropospheric Aerosol Trends Using Principal Component Analysis

The advanced very high resolution radiometer (AVHRR) satellite instruments provide a nearly 25 year continuous record of global aerosol properties over the ocean. It offers valuable insights into the long-term change in global aerosol loading. However, the AVHRR data record is heavily influenced by two volcanic eruptions, El Chichon on March 1982 and Mount Pinatubo on June 1991. The gradual decay of volcanic aerosols may last years after the eruption, which potentially masks the estimation of aerosol trends in the lower troposphere, especially those of anthropogenic origin. In this study, we show that a principal component analysis approach effectively captures the bulk of the spatial and temporal variability of volcanic aerosols into a single mode. The spatial pattern and time series of this mode provide a good match to the global distribution and decay of volcanic aerosols. We further reconstruct the data set by removing the volcanic aerosol component and reestimate the global and regional aerosol trends. Globally, the reconstructed data set reveals an increase of aerosol optical depth from 1985 to 1990 and decreasing trend from 1994 to 2006. Regionally, in the 1980s, positive trends are observed over the North Atlantic and North Arabian Sea, while negative tendencies are present off the West African coast and North Pacific. During the 1994 to 2006 period, the Gulf of Mexico, North Atlantic close to Europe, and North Africa exhibit negative trends, while the coastal regions of East and South Asia, the Sahel region, and South America show positive trends.

volcanoes↗

Model-Independent Time-Delay Interferometry Based on Principal Component Analysis

With a laser interferometric gravitational-wave detector in separate free flying spacecraft, the only way to achieve detection is to mitigate the dominant noise arising from the frequency fluctuations of the lasers via postprocessing. The noise can be effectively filtered out on the ground through a specific technique called time-delay interferometry (TDI), which relies on the measurements of time-delays between spacecraft and careful modeling of how laser noise enters the interferometric data. Recently, this technique has been recast into a matrix-based formalism by several authors, offering a different perspective on TDI, particularly by relating it to principal component analysis (PCA). In this work, we demonstrate that we can cancel laser frequency noise by directly applying PCA to a set of shifted data samples, without any prior knowledge of the relationship between single-link measurements and noise, nor time-delays. We show that this fully data-driven algorithm achieves a gravitational-wave sensitivity similar to classic TDI.

Quentin Baghi↗

Pulse shape discrimination in CUPID-Mo using principal component analysis

CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. It uses 20 scintillating $^{100}$Mo-enriched Li$_2$MoO$_4$ bolometers instrumented with Ge light detectors to perform active suppression of $\alpha$ backgrounds, drastically reducing the expected background in the $0\nu\beta\beta$ signal region. As a result, pileup events and small detector instabilities that mimic normal signals become non-negligible potential backgrounds. These types of events can in principle be eliminated based on their signal shapes, which are different from those of regular bolometric pulses. We show that a purely data-driven principal component analysis based approach is able to filter out these anomalous events, without the aid of detector response simulations.

47 OTHER INSTRUMENTATION↗

Applicability of Spectral Decomposition by Varimax-Rotated, Principal Component Analysis to the Surface Biology and Geology (SBG) VNIR Mission Concept

Cyanobacterial and Harmful Algal Blooms (CyanoHABs) are a growing concern in coastal and inland waters. But, spectral interference from multiple constituents in optically complex waters can hamper application of remote sensing using traditional image processing methods. The Kent State University (KSU) spectral decomposition method can be applied to multispectral and hyperspectral remote sensing images (e.g. HICO and the NASA Glenn HSI2) to partition and identify signals related to cyanobacteria, algae, pigment degradation products and suspended sediment in each pixel. Fundamental to the use of remote sensing data is the ability to extract independent signals from correlated hyperspectral VNIR data cubes. The Kent State University varimax-rotated, principal component analysis method (VPCA) is important to integrate into the SBG VNIR mission concept because it provides greater specificity, a software-based SNR boost relative to hardware performance, and can assist with Cal/Val, Modeling and Applications. We present examples of the hyperspectral application of the KSU VPCA method with relevance to SBG. The information extracted by VPCA can be validated spectrally or spatially with laboratory and/or in situ sensors, which capture spatial or time series of information at discrete points within remote sensing images. Comparisons show hyperspectral sensors extract more components than multispectral ones, but more independent information can be extracted from multispectral sensors by VPCA than traditional band ratio approaches. The spectral decomposition method is capable of enhancing the signal to noise ratio (SNR) of the NASA Glenn, second-generation hyperspectral imager by a factor of 7x to 20x, with a spectral reproducibility of ±3%. The spectral decomposition method, when compared against existing remote sensing monitoring methods exhibits both greater specificity and a lower detection limit. The method has been validated with multispectral images in Lake Erie to quantify the Microcystis CyanoHAB and from the Indian River Lagoon, Florida to quantify the Brown Tide resulting from A. lagunesnsis. Field operations in the Western Basin of Lake Erie were conducted using a bbe Fluoroprobe to collect vertical profiles and horizontal tows along a transect from the Toledo to the Detroit Lighthouse during coincident satellite overpasses. Extraction of pixel values from the MODIS Aqua sensor yields agreement between in situ field and lab-based measures of cyanobacterial, cryptophyte, diatoms and green algae, suspended sediment and pigment degradation products with R2>0.8.

hyperspectral↗

Application of Principal Component Analysis to NIR Spectra of Phyllosilicates: A Technique for Identifying Phyllosilicates on Mars

Orbital near-infrared (NIR) reflectance spectra of the martian surface from the OMEGA and CRISM instruments have identified a variety of phyllosilicates in Noachian terrains. The types of phyllosilicates present on Mars have important implications for the aqueous environments in which they formed, and, thus, for recognizing locales that may have been habitable. Current identifications of phyllosilicates from martian NIR data are based on the positions of spectral absorptions relative to laboratory data of well-characterized samples and from spectral ratios; however, some phyllosilicates can be difficult to distinguish from one another with these methods (i.e. illite vs. muscovite). Here we employ a multivariate statistical technique, principal component analysis (PCA), to differentiate between spectrally similar phyllosilicate minerals. PCA is commonly used in a variety of industries (pharmaceutical, agricultural, viticultural) to discriminate between samples. Previous work using PCA to analyze raw NIR reflectance data from mineral mixtures has shown that this is a viable technique for identifying mineral types, abundances, and particle sizes. Here, we evaluate PCA of second-derivative NIR reflectance data as a method for classifying phyllosilicates and test whether this method can be used to identify phyllosilicates on Mars.

Rampe, E. B.↗

Applying Two-Dimensional Correlation Spectroscopy and Principal Component Analysis to Understand How Temperature Affects the Neptunium(V) Absorption Spectrum

The visible-near infrared (Vis-NIR) electronic absorption spectrum of neptunium(V) (NpO 2 + ) comprises numerous f-f electronic transitions with mostly undocumented temperature dependencies. The effect of temperature on the absorption spectrum of the pentavalent neptunyl dioxocation (NpO 2 + ) is an important factor to consider with spectrophotometric applications but has often been overlooked. Optical Vis-NIR absorption spectra (400–1700 nm) of Np(V) (0.017–0.89 M) in 1 M nitric acid were evaluated with varying temperatures (T = 10–80 °C). The intensity, position, and overall shape of the bands were sensitive to interactions with the solvent and coordination environment. Numerous temperature-induced isosbestic points were identified resulting from dynamic, overlapping peak shifts. Spectral variations were characterized using principal component analysis (PCA) and 2D correlation spectroscopy (COS). 2D-COS revealed that the absorption band near 1095 nm likely consists of two bands centered near 1087 and 1096 nm, which cannot be explained by current computational methods. 2D-COS analysis also provided an unambiguous assignment of unresolved peaks in the visible region for comparison with computational predictions. PCA was used to identify nonlinearity in the spectral response at elevated Np(V) concentrations ≥ 0.5 M. This unique experimental data and interpretation will foster a deeper understanding of the absorption spectra for complex actinyl ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Application of Principal Component Analysis Using Fixed Eigenvectors to the Infrared Thermographic Inspection of the Space Shuttle Thermal Protection System

The Nondestructive Evaluation Sciences Branch at NASA s Langley Research Center has been actively involved in the development of thermographic inspection techniques for more than 15 years. Since the Space Shuttle Columbia accident, NASA has focused on the improvement of advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter s wing leading edge. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can be used to inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Principal Component Analysis (PCA) has been shown effective for reducing thermographic NDE data. A typical implementation of PCA is when the eigenvectors are generated from the data set being analyzed. Although it is a powerful tool for enhancing the visibility of defects in thermal data, PCA can be computationally intense and time consuming when applied to the large data sets typical in thermography. Additionally, PCA can experience problems when very large defects are present (defects that dominate the field-of-view), since the calculation of the eigenvectors is now governed by the presence of the defect, not the good material. To increase the processing speed and to minimize the negative effects of large defects, an alternative method of PCA is being pursued when a fixed set of eigenvectors is used to process the thermal data from the RCC materials. These eigen vectors can be generated either from an analytic model of the thermal response of the material under examination, or from a large cross section of experimental data. This paper will provide the details of the analytic model; an overview of the PCA process; as well as a quantitative signal-to-noise comparison of the results of performing both embodiments of PCA on thermographic data from various RCC specimens. Details of a system that has been developed to allow insitu inspection of a majority of shuttle RCC components will be presented along with the acceptance test results for this system. Additionally, the results of applying this technology to the Space Shuttle Discovery after its return from flight will be presented.

Cramer, K. Elliott↗

ASCoT 3: Nonlinear Principal Components Analysis and Uncertainty Quantification in Early Concept Spacecraft Flight Software Cost Estimation

For mission planners and evaluators alike, value in cost models comes from a mean or median prediction, an understanding of the uncertainty on that prediction, and an understanding of model performance. Here we apply advanced statistical and machine learning methods to spacecraft flight software cost, effort, and SLOC estimation, and present the results in the latest version of the Analogy Software Cost Tool (ASCoT). We present in- and out-of-sample performance metrics for our models, each of which incorporate some amount of epistemic uncertainty. ASCoT, hosted on the One NASA Cost Engineering (ONCE) database via the Online NASA Space Estimation Tool (ONSET), was first showcased in 2016 as a number of analogy-based models and methods (kNN and Clustering) to support early project formulation. This ASCoT update improves upon the previous analogic methods by incorporating uncertainty in the data transformations. In particular, we use a Nonlinear Principal Components Analysis (NLPCA) to deal with ordinal data.

Robotic Spacecraft↗

Application of Principal Component Analysis for the Monitoring of the Aging Process of Nuclear Electrical Cable Insulation

To ensure the safe operation of nuclear power plants (NPPs), it is critical to understand how NPP electrical cable insulation will degrade under different service environments. In this study, various nondestructive examination methods were selected to evaluate degradation of electrical cable insulation after aging. Elongation at break, indenter modulus, relaxation constant, mass change, total color difference, and carbonyl index were collected stepwise on cross-linked polyethylene (XLPE) cable insulations after predetermined exposure intervals. Three different insulation aging scenarios were investigated: 1) simultaneous irradiation and heating at 150°C, 2) heating at 150°C followed by corresponding times of irradiation at ambient temperature, and 3) irradiation at ambient temperature followed by heating at 150°C for the same duration. A constant dose rate of 300 Gy/hr was selected with a total gamma irradiation absorbed dose up to 320 kGy. To gain insight into the long-term performance of NPP electrical cable insulation, principal component analysis (PCA), a data-driven approach, was utilized to identify key indicators of cable insulation degradation. By reducing the dimensionality of the data while retaining degradation information, PCA was used to highlight the changes in the measured properties under gamma irradiation according to total absorbed dose and the different aging scenarios.

Li, Donghui↗

Principal Component Analysis of Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

In nuclear power plants (NPPs), the aging of electrical cable insulation occurs due to elevated temperature, ionizing radiation, and other environmental factors. To ensure the safe and efficient operation of NPPs, determination of key indicators of cable aging is critical to predict the remaining useful lifetime of electrical cable insulation. In this work, the effects of simultaneous and sequential thermal and gamma radiation on the aging of cross-linked polyethylene (XLPE) electrical cable insulation are investigated. The chemical changes of the insulation were monitored non-destructively through the use of Fourier transform infrared (FTIR) spectroscopy. The FTIR spectra were measured stepwise after predetermined exposure intervals, with a total irradiation dose up to 320 kGy at a dose rate of 300 Gy/hr in two exposure scenarios; simultaneously aged samples were heated at 150 °C during irradiation, while sequentially aged samples were heated at 150 °C for designated durations followed by corresponding times of irradiation at ambient temperature. A data-driven approach using principal component analysis (PCA) was developed to highlight changes in the carbonyl region of the infrared spectra of the aged samples due to oxidation and to differentiate oxidation rates under the simultaneous and sequential exposure conditions. Findings indicate that the sequential aging scenario may be more conservative than the simultaneous aging scenario for XLPE electrical cable insulation.

Li, Donghui↗

Video Summarization Using Deep Action Recognition Features and Robust Principal Components Analysis

In an instance where desired pre-defined actions, behaviors, or other categories are known a priori, various video classification and recognition models can be trained to discover those classifications and their location within the video. Absent that information, one might still be tasked with identifying interesting portions within a video, a process which—if done manually—is onerous and time-consuming as it requires manual inspection of the video itself. Recognizing high-level interesting segments within a whole video has been a general area of interest due to the ubiquity of video data. However the size of the data makes storage, retrieval, and inspection of large collections of videos cumbersome. This problem motivates the task of generating shortened clips highlighting the primary content of a video, relieving the burden of having to watch the entire video. This paper presents an unsupervised method of creating shortened clips of videos, enabling the rapid review of the most interesting content within a video. Our method uses features extracted from pre-trained action recognition models as input to online moving window robust principal component analysis to generate summaries. The procedure is tested on a publicly available video summarization dataset and demonstrates comparable performance to state-of-the-art in an un-augmented setting while requiring no training.

Claborne, Daniel M.↗

Use of Machine Learning and Principal Component Analysis to Retrieve Nitrogen Dioxide (NO 2 ) With Hyperspectral Imagers and Reduce Noise in Spectral Fitting

Nitrogen dioxide (NO 2 ) is an important trace-gas pollutant and climate agent whose presence also leads to spectral interference in ocean color retrievals. NO 2 column densities have been retrieved with satellite UV–Vis spectrometers such as the Ozone Monitoring Instrument (OMI) and the Tropospheric Monitoring Instrument (TROPOMI) that typically have spectral resolutions of the order of 0.5 nm or better and spatial footprints as small as 3.6 km × 5.6 km. These NO 2 observations are used to estimate emissions, monitor pollution trends, and study effects on human health. Here, we investigate whether it is possible to retrieve NO 2 amounts with lower-spectral-resolution hyperspectral imagers such as the Ocean Color Instrument (OCI) that will fly on the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) satellite set for launch in early 2024. OCI will have a spectral resolution of 5 nm and a spatial resolution of ∼ 1 km with global coverage in 1–2 d. At this spectral resolution, small-scale spectral structure from NO 2 absorption is still present. We use real spectra from the OMI to simulate OCI spectra that are in turn used to estimate NO 2 slant column densities (SCDs) with an artificial neural network (NN) trained on target OMI retrievals. While we obtain good results with no noise added to the OCI simulated spectra, we find that the expected instrumental noise substantially degrades the OCI NO 2 retrievals. Nevertheless, the NO 2 information from OCI may be of value for ocean color retrievals. OCI retrievals can also be temporally averaged over timescales of the order of months to reduce noise and provide higher-spatial-resolution maps that may be useful for downscaling lower-spatial-resolution data provided by instruments such as OMI and TROPOMI; this downscaling could potentially enable higher-resolution emissions estimates and be useful for other applications. In addition, we show that NNs that use coefficients of leading modes of a principal component analysis of radiance spectra as inputs appear to enable noise reduction in NO 2 retrievals. Once trained, NNs can also substantially speed up NO 2 spectral fitting algorithms as applied to OMI, TROPOMI, and similar instruments that are flying or will soon fly in geostationary orbit.

NO2↗

A Technique Using Principal Component Analysis to Compare Seasonal Cycles of Earth Radiation from CERES and Model Computations

A method for quantitatively comparing the seasonal cycles of two global data sets is presented. The seasonal cycles of absorbed solar radiation (ASR) and outgoing longwave radiation (OLR) have been computed from an eight-year data set from the Clouds and Earth's Radiant Energy System (CERES) scanning radiometers and from a model data set produced by the NASA Goddard Space Flight Center Global Modeling and Assimilation Office. To compare the seasonal cycles from these two data sets, principal component (PC) analysis is used, where the PCs express the time variations and the corresponding empirical orthogonal functions (EOFs) describe the geographic variations. Ocean has a long thermal response time compared to land, so land and ocean are separated for the analysis. The root-mean square values for the seasonal cycles of ASR and OLR are extremely close for the two data sets. The first three PCs are quite close, showing that the time responses and magnitudes over the globe are very similar. The agreement between the two sets of PCs is quantified by computing the matrix of inner products of the two sets. For ASR over land, the first PCs of CERES and the model agree to better than 99.9%. The EOF maps are similar for most of the globe, but differ in a few places, and the agreement of the EOF maps is likewise quantified. Maps of differences between the annual cycles show regions of agreement and disagreement.

Smith, G. Louis↗

Identifying Nuclear Data Correlated Through Predicting Bias in Integral Experiments via Applying Principal Component Analysis to Random Forest

ABSTRACT Nuclear data (ND) are the input data for neutron‐transport simulations to answer questions related to nuclear technologies. Subsets of ND, here > 20,000 data points, are validated with respect to thousands of criticality experiments that represent various applications on a small scale. The aim of validation with these experiments is to find errors in ND or methods. The key challenge here is that several hundreds of ND are used to simulate one integral value. Hence, one cannot clearly identify what ND are leading to bias in criticality measurements. In fact, a mistake in one nuclear‐data observable can be compensated with an error in another, and the predicted criticality value would still be predicted in agreement with experimental data. Random forest (RF) was previously employed to predict bias in criticality measurements using sensitivities of simulated criticality experiments to ND. The SHapley Additive exPlanations (SHAP) metric was then applied to attribute the importance of each ND experiment and observable to bias prediction. This, however, did not highlight what ND were jointly related to predicting bias. This is important as it could inform us about where compensating errors in ND could hide. We tackle this shortcoming here by first decomposing the ND sensitivities to integral‐experiment simulations into principal components. Then we use principal component projections to predict bias via the RF and SHAP. The SHAP values and principal components are employed to reconstruct detailed SHAP values for each ND observable. We demonstrate that these extended SHAP bias predictions are more robust, less noisy, and more efficient. In addition, we show that this approach accounts for covariance in ND sensitivities and automates the identification of where compensating errors could hide in ND.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty quantification of an empirical shell-model interaction using principal component analysis

Recent investigations have emphasized the importance of uncertainty quantification (UQ) in nuclear theory. Here, we carry out UQ for configuration-interaction shell-model calculations in the 1$\textit{s}$–0$\textit{d}$ valence space, investigating the sensitivity of observables to perturbations in the 66 parameters (matrix elements) of a high-quality empirical interaction. The large parameter space makes computing the corresponding Hessian numerically costly, so we compare a cost-effective approximation, using the Feynman-Hellmann theorem, to the full Hessian and find it works well. Diagonalizing the Hessian yields the principal components of the interaction: linear combinations of parameters ordered by sensitivity. This approximately decoupled distribution of parameters facilitates theoretical uncertainty propagation onto structure observables: electromagnetic transitions, Gamow-Teller decays, and dark matter-nucleus scattering matrix elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗