Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optical zero-differential pressure switch and its evaluation in a multiple pressure measuring system

The design of a clamped-diaphragm pressure switch is described in which diaphragm motion is detected by a simple fiber-optic displacement sensor. The switch was evaluated in a pressure measurement system where it detected the zero crossing of the differential pressure between a static test pressure and a tank pressure that was periodically ramped from near zero to fullscale gage pressure. With a ramping frequency of 1 hertz and a full-scale tank pressure of 69 N/sq cm gage (100 psig), the switch delay was as long as 2 milliseconds. Pressure measurement accuracies were 0.25 to 0.75 percent of full scale. Factors affecting switch performance are also discussed.

Powell, J. A.↗

Precision ozone vapor pressure measurements

The vapor pressure above liquid ozone has been measured with a high accuracy over a temperature range of 85 to 95 K. At the boiling point of liquid argon (87.3 K) an ozone vapor pressure of 0.0403 Torr was obtained with an accuracy of + or - 0.7 percent. A least square fit of the data provided the Clausius-Clapeyron equation for liquid ozone; a latent heat of 82.7 cal/g was calculated. High-precision vapor pressure data are expected to aid research in atmospheric ozone measurements and in many laboratory ozone studies such as measurements of cross sections and reaction rates.

Hanson, D.↗

Stand Alone Pressure Measurement Device (SAPMD) for the space shuttle Orbiter, part 1

The specifications for the Stand Alone Pressure Measurement Device (SAPMD) are as follows: the SAPMD shall measure ambient pressure at the surface of the Orbiter TPS in the range of 0 to 15 pounds per square inch absolute (PSIA). Measurement will begin at solid rocket booster (SRB) ignition as sensed by appropriate vibration sensing elements in the SAPMD. Pressure and corresponding real-time data are to be recorded every one tenth second for 140 seconds and at the end of the recording period, the operation will be discontinued with the data preserved for interrogation subsequent to Orbiter re-entry and landing. The type and size of the battery shall be such as to allow the vibration sensing elements and a real-time clock to be initialized a minimum of 30 day prior to launch and still provide power as necessary to perform the 140 second data recording period after SRB ignition. Battery installation shall be in such a manner as to allow battery replacement without removing the SAPMD from its position or removing more than one TPS tile. The SAPMD must be mounted in specific locations under tile of the TPS. To accommodate such mounting, the absolute maximum physical dimensions much not exceed 6.0 inches in length, 1.5 inches in width, and 0.4 inches in height, and the device shall be of such configuration that it can be bonded to the Orbiter skin at the joint line of two TPS tiles with the pressure sensing port at the surface of the tile. The SAPMD must remain operational in the temperature range of -40 to +85 C and survive storage temperature of -55 to +125 C. The pressure port must withstand 934 C without causing damage to the TPS during entry and must remain functional at 262 C during ascent. The accuracy of the pressure measurement must be plus or minus one-half PSIA over a temperature range of 0 to +36 C. All the specifications were met and verified by prototype testing and documented in the enclosed test data. Four flight-qualified models were fabricated and of these, two were delivered and successfully flown in the cargo bay of STS-26.

Tomlinson, Bill↗

Automatic Blood Pressure Measurements During Exercise

Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

Weaver, Charles S.↗

Blood-Pressure Measuring System Gives Accurate Graphic Output

The problem: To develop an instrument that will provide an external (indirect) measurement of arterial blood pressure in the form of an easily interpreted graphic trace that can be correlated with standard clinical blood-pressure measurements. From sphygmograms produced by conventional sphygmographs, it is very difficult to differentiate the systolic and diastolic blood-pressure pulses and to correlate these indices with the standard clinical values. It is nearly impossible to determine these indices when the subject is under physical or emotional stress. The solution: An electronic blood-pressure system, basically similar to conventional ausculatory sphygmomanometers, employing a standard occluding cuff, a gas-pressure source, and a gas-pressure regulator and valve. An electrical output transducer senses cuff pressure, and a microphone positioned on the brachial artery under the occluding cuff monitors the Korotkoff sounds from this artery. The output signals present the conventional systolic and diastolic indices in a clear, graphical display. The complete system also includes an electronic timer and cycle-control circuit.

Source record↗

Temperature and pressure measurement techniques for an advanced turbine test facility

A high pressure, high-temperature turbine test facility constructed for use in turbine cooling research is described. Several recently developed temperature and pressure measuring techniques are used in this facility. The measurement techniques, their status, previous applications and some results are discussed. Noncontact surface temperature measurements are made by optical methods. Radiation pyrometry principles combined with photoelectric scanning are used for rotating components and infrared photography for stationary components. Contact (direct) temperature and pressure measurements on rotating components are expected to be handled with an 80 channel rotary data package which mounts on and rotates with the turbine shaft at speeds up to 17,500 rpm. The data channels are time-division multiplexed and converted to digital words in the data package. A rotary transformer couples power and digital data to and from the shaft.

Pollack, F. G.↗

Temperature and pressure measurement techniques for an advanced turbine test facility

A high pressure, high-temperature turbine test facility is being constructed at the NASA Lewis Research Center for use in turbine cooling research. Several recently developed temperature and pressure measuring techniques will be used in this facility. This paper describes these measurement techniques, their status, previous applications and some results. Noncontact surface temperature measurements will be made by optical methods. Radiation pyrometry principles combined with photoelectric scanning will be used for rotating components and infrared photography for stationary components. Contact (direct) temperature and pressure measurements on rotating components will be handled with an 80-channel rotary data package which mounts on and rotates with the turbine shaft at speeds up to 17,500 rpm. The data channels are time-division multiplexed and converted to digital words in the data package. A rotary transformer couples power and digital data to and from the shaft.

Pollack, F. G.↗

Defining and Measuring Pressure Gain

This presentation describes experimental and computational approaches to measuring pressure gain in the various devices currently under investigation wherein the working fluid undergoes a pressure gain combustion (PGC) process. Pressure gain is essentially a measure of the fluid availability for work or thrust production. The devices covered are Resonant Pulse Combustors, Internal Combustion Wave Rotors, Pulse Detonation Engines, and Rotating Detonation Engines. The approaches to pressure gain measurement differ in each device. However, all of the approaches attempt to address the fundamental challenges of PGC system measurement: the extremely harsh environment which makes instrumentation difficult, and the temporal and spatial non-uniformity associated with the exhausting flow which makes assigning a single value to the total pressure difficult. As part of the two-day 2019 International Constant Volume and Detonative Combustion Workshop, held in conjunction with the 2019 AIAA Propulsion and Energy Forum, this presentation is intended to foster discussion and eventual consensus on acceptable measurement methods.

pressure gain combustion↗

Predictions of F-111 TACT aircraft buffet response and correlations of fluctuating pressures measured on aluminum and steel models and the aircraft

Results of buffet research that was conducted as part of the joint USAF/NASA F-111 TACT Research Program are presented. The correlation of wind tunnel and flight measurements of buffet excitation showed that there generally was good agreement between measurements of pressure fluctuations on the models and aircraft in regions of separated flow. At shock-wave boundaries of the separated flow, correlations of pressure fluctuations were not so good, due to Reynolds number and static elastic effects. The buffet prediction method, which applies a forcing function that is obtained by real-time integration of pressure time histories with the natural modes, is described. The generalized forces, including the effects of wing and tail, correlations of predicted and measured damping, and correlations of predicted and measured buffet response are presented. All presented data are for a Mach number of 0.8 with wing-sweep angles of 26 and 35 deg for a range of angles-of-attack that include buffet onset to high intensity buffeting. Generally, the buffet predictions were considered to be quite good particularly in light of past buffet-prediction experience.

Coe, Charles F.↗

Pressure Measurements in a Wire-Wrapped 61-Pin Hexagonal Fuel Bundle

Texas A and M University is conducting isothermal experiments in a wire-wrapped 61-pin hexagonal fuel bundle to support the research on advanced nuclear fuel development sponsored by the Department of Energy (DOE). The purpose of these experiments is to produce high spatial and temporal resolution measurements of the flow and pressure measurements at different locations of the test bundle. The experimental data will be used to benchmark numerical simulations of the experiments using both industry-standard Reynolds-averaged Navier-Stokes (RANS) based computational fluid dynamics (CFD) methods and highly resolved large eddy simulations (LES). (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The design and analysis of beam-membrane structure sensors for micro-pressure measurement

This paper reports the design and analysis of a type of piezoresistive pressure sensor for micro-pressure measurement with a cross beam-membrane (CBM) structure. This new silicon substrate-based sensor has the advantages of a miniature structure and high sensitivity, linearity, and accuracy. By using the finite element method to analyze the stress distribution of the new structure and subsequently deducing the relationship between structural dimensions and mechanical performances, equations used to determine the CBM structure are established. Based on the CBM model and our stress and deflections equations, sensor fabrication is then performed on the silicon wafer via a process including anisotropy chemical etching and inductively coupled plasma. The structure's merits, such as linearity, sensitivity, and repeatability, have been investigated under the pressure of 5 kPa. Our results show that the precision of these equations is {+-}0.19%FS, indicating that this new small-sized structure offers easy preparation, high sensitivity, and high accuracy for micro-pressure measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flight-measured pressure characteristics of aft-facing steps in thick boundary layer flow for transonic and supersonic Mach numbers

Aft-facing step base pressure flight data were obtained for three step heights for nominal transonic Mach numbers of 0.80, 0.90, and 0.95, and for supersonic Mach numbers of 2.2, 2.5, and 2.8 with a Reynolds number, based on the fuselage length ahead of the step, of about 10 to the 8th power. Surface static pressures were measured ahead of the step, behind the step, and on the step face (base), and a boundary layer rake was used to obtain boundary layer reference conditions. A comparison of the data from the present and previous experiments shows the same trend of increasing base pressure ratio (decreasing drag) with increasing values of momentum thickness to step height ratios. However, the absolute level of these data does not always agree at the supersonic Mach numbers. For momentum thickness to height ratios near 1.0, the differences in the base pressure ratios appear to be primarily a function of Reynolds number based on the momentum thickness. Thus, for Mach numbers above 2, the data analyzed show that the base pressure ratio decreases (drag increases) as Reynolds number based on momentum thickness increases for a given momentum thickness and step height.

Powers, S. G.↗

Discrete and Continuum Plane-Hopper Flow Simulations with Experimental Validation Using X-Ray Imaging, Arch Profilometry and Wall Pressure Measurements

The flow of spherical glass beads, approximately cubic wood crumbles®, and wood microchips are investigated using a combination of discrete element modeling (DEM), finite element analysis (FEA), and physical experiments using a custom plane-flow hopper in which the flow is characterized using x-ray imaging, profilometry to measure arching geometry and pressure measurements at the wall. The purpose of this study is to investigate fundamental flow behavior, and for this purpose the simulations and physical tests are specially designed. During the physical tests and simulations, the hopper geometry begins as a V shape with the two opposing side walls touching at the bottom of the V. Basic tests are performed by first filling the hopper with material, and then rotating the opposing side walls inward about their common intersection axis to cause an approximately uniform stress condition throughout most of the hopper. The side walls then slide upward to effectively increase the size of the opening at the bottom of the hopper until the arch of material in the hopper breaks, and all of the material falls out of the hopper. More advanced tests are also performed in which the initial rotation of the walls is slightly reversed to decrease the pressure in the hopper, corresponding to “preshear” and “shear” conditions in standard shear tests. Shear tests of the materials are also performed using a Schulze automated ring shear tester with a standard size M shear cell, and the shear tests of the glass beads and wood crumbles® are also simulated using DEM to calibrate the DEM with the FEA. Reasonable agreement between predicted and measured flow behavior is obtained indicating that this type of physical tests and modeling shows promise for characterizing and predicting the flow behavior of compressible and anisotropic materials.

09 BIOMASS FUELS↗

Methodology of Blade Unsteady Pressure Measurement in the NASA Transonic Flutter Cascade

In this report the methodology adopted to measure unsteady pressures on blade surfaces in the NASA Transonic Flutter Cascade under conditions of simulated blade flutter is described. The previous work done in this cascade reported that the oscillating cascade produced waves, which for some interblade phase angles reflected off the wind tunnel walls back into the cascade, interfered with the cascade unsteady aerodynamics, and contaminated the acquired data. To alleviate the problems with data contamination due to the back wall interference, a method of influence coefficients was selected for the future unsteady work in this cascade. In this approach only one blade in the cascade is oscillated at a time. The majority of the report is concerned with the experimental technique used and the experimental data generated in the facility. The report presents a list of all test conditions for the small amplitude of blade oscillations, and shows examples of some of the results achieved. The report does not discuss data analysis procedures like ensemble averaging, frequency analysis, and unsteady blade loading diagrams reconstructed using the influence coefficient method. Finally, the report presents the lessons learned from this phase of the experimental effort, and suggests the improvements and directions of the experimental work for tests to be carried out for large oscillation amplitudes.

Lepicovsky, J.↗

Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements

Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.

Whitmore, Stephen A.↗