Porous leak evaluation and application to calibration of a high-pressure ion gauge
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The invention provides a system for detecting leaks in glovebox gloves, the system having a first seal within a glovebox aperture; a second seal contacting exterior surfaces of a glovebox, wherein the exterior surfaces define a periphery of the aperture; a first fluid supply for circumferentially expanding the first seal against center facing surfaces of the aperture to a first pressure; a second fluid supply for inflating the glove to a second pressure; and a pressure gauge for detecting a pressure decrease of the second pressure. Also provided is an in situ method for detecting leaks in glove box gloves, the method having the steps of applying a radially directed force to inside surfaces of cuffs of the gloves to hermetically seal the gloves from the exterior of the glovebox, thereby establishing a seal; inflating the gloves to a pressure; and monitoring the pressure for any decrease in pressure.
A major challenge in understanding differences in electric propulsion performance in ground tests and in space operations concerns the pressure distribution within the test vacuum chamber. The chamber backpressure is much higher than experienced in space, modifying thruster performance and plume dynamics. Numerical simulation is a key element to determining the background conditions in non-ideal vacuum chamber environments. An important parameter for the accurate simulation of chamber backpressure is the probability that an atom will stick to a cryogenic panel used to pump away the plume gases. This quantity can be used to model vacuum pumps in particle-based kinetic numerical methods. In this work, a three-dimensional direct simulation Monte Carlo code is used to model neutral xenon atoms flowing from the anode of the H9 Hall Effect Thruster within the University of Michigan’s Large Vacuum Test Facility. Simulated pressures are compared with ion gauge pressure measurements to infer the effective sticking coefficient of the chamber’s vacuum pumps. A pressure predicting surrogate model is developed for inference of pump sticking coefficients and for uncertainty quantification. This information enables accurate and useful kinetic simulations of electric propulsion thruster plasma plumes in vacuum chambers.
Sandia National Laboratories has developed a computer program to review, reduce and manipulate waveform data. PlotData is designed for post-acquisition waveform data analysis. PlotData is both a post-acquisition and an advanced interactive data analysis environment. PlotData requires unidirectional waveform data with both uniform and discrete time-series measurements. PlotData operates on a National Instruments' LabVIEW™ software platform. Using PlotData, the user can capture waveform data from digitizing oscilloscopes over a GPIB, USB and Ethernet interface from Tektronix, Lecroy or Agilent scopes. PlotData can both import and export several types of binary waveform files including, but not limited to, Tektronix .wmf files, Lecroy.trc files and xy pair ASCIIfiles. Waveform manipulation includes numerous math functions, integration, differentiation, smoothing, truncation, and other specialized data reduction routines such as VISAR, POV, PVDF (Bauer) piezoelectric gauges, and piezoresistive gauges such as carbon manganin pressure gauges.
As a case study for uncertainty analysis, we consider a model flow monitor for measuring enrichment in gas centrifuge enrichment plants (GCEPs) that could provide continuous monitoring of all declared gas flow and provide high-accuracy gas enrichment estimates as a function of time. The monitor system could include NaI(Tl) gamma-ray spectrometers, a pressure signal-sharing device to be installed on an operator\rq{}s pressure gauge or a dedicated inspector pressure sensor, and temperature sensors attached to the outside of the header pipe, to provide pressure, temperature, and gamma-ray spectra measurements of UF$_6$ gas flow through unit header pipes. Our study builds on previous modeling and analysis methods development for enrichment monitor concepts and a software tool that was developed at Oak Ridge National Laboratory to generate and analyze synthetic data.
Design, construction, and experimental evaluation of in-flight calibration system for satellite mass spectrometers and pressure gauges
Drawings and designs of temperature and pressure gauges for high temperature thermocouples
Hydrogen, nitrogen, oxygen and helium gas pumping by ionization pressure gauges in space simulators
Inelastic neutron scattering measurements typically require two orders of magnitude longer data collection times and larger sample sizes than neutron diffraction studies. Inelastic neutron scattering measurements on pressurised samples are particularly challenging since standard high-pressure apparatus restricts sample volume, attenuates the incident and scattered beams, and contributes background scattering. Here, we present the design of a large volume two-layered piston-cylinder pressure cell with optimised transmission for inelastic neutron scattering experiments. The design and the materials selected for the construction of the cell enable its safe use to a pressure of 1.8 GPa with a sample volume in excess of 400 mm{sup 3}. The design of the piston seal eliminates the need for a sample container, thus providing a larger sample volume and reduced absorption. The integrated electrical plug with a manganin pressure gauge offers an accurate measurement of pressure over the whole range of operational temperatures. The performance of the cell is demonstrated by an inelastic neutron scattering study of UGe{sub 2}.
A material called Thermkeep, developed as a low-cost method for the storage of thermal energy for solar electric power generating systems is discussed. The storage device consists of an insulated cylinder containing Thermkeep in which coiled tubular heat exchangers are immersed. A one-tenth scale model of the design contains 25 heat-exchanger tubes and 1500 kg of Thermkeep. Its instrumentation includes thermocouples to measure internal Thermkeep temperatures, vessel surface, heated shroud surface, and pressure gauges to indicate heat-exchanger pressure drops. The test-circuit design is presented and experimental results are discussed.
Falling sphere, solar XUV radiation absorption and pressure gauge mass spectrometry for density measurements of thermosphere, comparing results and noting discrepancies
Powder feeder for oxygen-sensitive powders facilitates transfer of powder while protecting it against oxidation. Sight gauge enables continuous monitoring of level to which feeder filled with powder, as well as for visual monitoring of quality powder. Coupling mates with specially designed containers, in which powders packaged under vacuum or inert gas. Eliminating need for unncessary handling of powders and attendant risk of contamination by oxygen. Internal funnel unloads unused powder from feeder in vacuum or inert-gas atmosphere. Pressure gauge monitors pressure of inert backfill gas.
Volume-ratio calibration system consists of a gas source, high pressure gauge, small volume tank, large volume chamber, plus appropriate piping, valves, and vacuum source. This system used in conjunction with commercial vacuum gauges evaluates its ability to accurately produce desired pressures in the .000001 to .01 torr range.
Mass fluxes of ZnSe by physical vapor transport (PVT) were measured in the temperature range of 1050 to 1160 C using an in-situ dynamic technique. The starting materials were either baked out or distilled under vacuum to obtain near-congruently subliming compositions. Using an optical absorption technique Zn and Se, were found to be the dominant vapor species. Partial pressures of Zn and Se, over the starting materials at temperatures between 960 and 1140 C were obtained by measuring the optical densities of the vapor phase at the wavelengths of 2138, 3405, 3508, 3613, and 3792 A. The amount and composition of the residual gas inside the experimental ampoules were measured after the run using a total pressure gauge. For the first time, the experimentally determined partial pressures of Zn and Se, and the amount and composition of the residual gas were used in a one-dimensional diffusion limited analysis of the mass transport rates for a PVT system. Reasonable agreement between the experimental and theoretical results was observed.
Shock initiation experiments were performed on mechanically and thermally damaged LX-04 (85% HMX and 15% Viton by weight) to obtain in-situ manganin pressure gauge data and run distances to detonation at various shock pressures. The LX-04 charges were damaged mechanically by applying a compressive load of 600 psi for 20,000 cycles, thus creating many small narrow cracks, or by cutting wedge shaped parts that were then loosely reassembled, thus creating a few large cracks. The thermal damaged LX-04 charges were heated to 190 C for a long enough time for the beta to delta phase transition to occur and then cooled to ambient temperature. Mechanically damaged LX-04 exhibited only slightly increased shock sensitivity, while the thermally damaged LX-04 was much more shock sensitive. The pristine LX-04 Ignition and Growth model, modified only by igniting a larger amount of explosive during shock compression based on the damaged charge density, accurately calculated the increased shock sensitivity of the three damaged charges.
The design and supporting systems for the cooled-wall expansion cloud chamber, designated Proto II, are described. The chamber is a 10-sided vertical cylinder designed to be operated with interior wall temperatures between +40 and -40 C, and is to be utilized to study microphysical processes active in atmospheric clouds and fogs. Temperatures are measured using transistor thermometers which have a range of + or - 50 C and a resolution of about + or - 0.001 C; and pressures are measured in the chamber by a differential strain gauge pressure transducer. The methods used for temperature and pressure control are discussed. Consideration is given to the chamber windows, optical table, photographic/video, optical attenuation, Mie scattering, and the scanning system for the chamber. The system's minicomputer and humidifier, sample preparation, and chamber flushing are examined.
Explosive and propellant charges are subjected to various mechanical and thermal insults that can increase their sensitivity over the course of their lifetimes. To quantify this effect, shock initiation experiments were performed on mechanically and thermally damaged LX-04 (85% HMX, 15% Viton by weight) and PBX 9502 (95% TATB, 5% Kel-F by weight) to obtain in-situ manganin pressure gauge data and run distances to detonation at various shock pressures. We report the behavior of the HMX-based explosive LX-04 that was damaged mechanically by applying a compressive load of 600 psi for 20,000 cycles, thus creating many small narrow cracks, or by cutting wedge shaped parts that were then loosely reassembled, thus creating a few large cracks. The thermally damaged LX-04 charges were heated to 190 C for long enough for the beta to delta solid - solid phase transition to occur, and then cooled to ambient temperature. Mechanically damaged LX-04 exhibited only slightly increased shock sensitivity, while thermally damaged LX-04 was much more shock sensitive. Similarly, the insensitive explosive PBX 9502 was mechanically damaged using the same two techniques. Since PBX 9502 does not undergo a solid - solid phase transition but does undergo irreversible or 'rachet' growth when thermally cycled, thermal damage to PBX 9502 was induced by this procedure. As for LX-04, the thermally damaged PBX 9502 demonstrated a greater shock sensitivity than mechanically damaged PBX 9502. The Ignition and Growth reactive flow model calculated the increased sensitivities by igniting more damaged LX-04 and PBX 9502 near the shock front based on the measured densities (porosities) of the damaged charges.
The beam chamber of Variable Energy Cyclotron Centre, Kolkata's K = 500 superconducting cyclotron is pumped by liquid helium cooled cryopanel with liquid nitrogen cooled radiation shield. Performance of the vacuum system was evaluated by cooling the cryopanel assembly with liquid nitrogen and liquid helium. Direct measurement of beam chamber pressure is quite difficult because of space restrictions and the presence of high magnetic field. Pressure gauges were placed away from the beam chamber. The beam chamber pressure was evaluated using a Monte Carlo simulation software for vacuum system and compared with measurements. The details of the vacuum system, measurements, and estimation of pressure of the beam chamber are described in this paper.