Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRECESSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

65 records · Page 4

On Final Results From the Muon $g\mathrm{-}2$ Experiment at Fermilab

The Muon g-2 Experiment at Fermilab has measured the muon anomalous magnetic moment, a_mu, with unprecedented precision, leveraging a dataset from Runs 1 6 that is 21 times larger than its Brookhaven predecessor. This talk will present the experiment s final result, which serves as a benchmark for testing the Standard Model with high precision. The measurement was performed in a storage ring with a highly uniform magnetic field, where precise beam dynamics understanding is vital to determine the muon anomalous precession frequency. Key to this effort were advanced simulation tools including COSY INFINITY, precise fringe field modeling, and calculations of beam dynamics characteristics like tunes and chromaticity. We will conclude by exploring how the experiment's findings reshape our understanding of particle physics.

Valetov, Eremey [Michigan State U.]↗

Snakes for the Hadron Storage Ring

The Electron Ion Collider calls for collisions of polarized proton and polarized helion beams on polarized electron beams. To preserve polarization of these polarized hadron beams during acceleration, six full helical snakes will be installed. As there are currently 4 snakes in RHIC, the remaining two snakes will be made from existing rotator magnet coils. The existing snakes are made from only right-handed helices where the rotator magnets are made from both right handed and left handed helicity magnets. In order for a sufficient stock of spare coils, one snake will be made of left handed coils. Simulations using Opera field maps in zgoubi show the left handed snake has sufficient range to provide the desired snake precession axes for helions and protons with the existing power supplies. This is an overview of the right and left handed snake assemblies and their effects.

43 PARTICLE ACCELERATORS↗

Rotators for the Hadron Storage Ring

The Electron Ion Collider calls for collisions of polarized electrons on transversely and longitudinally polarized protons and helions. To facilitate longitudinal polar ization, helical dipole rotator magnets from the Relativistic Heavy Ion Collider will be reused. These rotators are placed asymmetrically at -35.28 and 61.35 mrad from the interaction point. Longitudinal polarization of polarized protons cannot be satisfied for all energies while remaining below the maximum current of 322 A. Care has been taken to ensure longitudinal polarization can be satisfied at the energies of interest. The rotators ramping result in a shift in νs which has been compensated for with a change in the snake precession axes. The rotators can satisfy longitudinal polarization at all energies of interest, and the νs compensation has also been established.

43 PARTICLE ACCELERATORS↗

The Santa Barbara Binary-disk Code Comparison

We have performed numerical calculations of a binary interacting with a gas disk, using 11 different numerical methods and a standard binary-disk setup. The goal of this study is to determine whether all codes agree on a numerically converged solution and to determine the necessary resolution for convergence and the number of binary orbits that must be computed to reach an agreed-upon relaxed state of the binary-disk system. We find that all codes can agree on a converged solution (depending on the diagnostic being measured). The zone spacing required for most codes to reach a converged measurement of the torques applied to the binary by the disk is roughly 1% of the binary separation in the vicinity of the binary components. For our disk model to reach a relaxed state, codes must be run for at least 200 binary orbits, corresponding to about a viscous time for our parameters, 0.2(a 2 Ω B /v) is the kinematic viscosity. The largest discrepancies between codes resulted from the dimensionality of the setup (3D vs. 2D disks). We find good agreement in the total torque on the binary between codes, although the partition of this torque between the gravitational torque, orbital accretion torque, and spin accretion torque depends sensitively on the sink prescriptions employed. In agreement with previous studies, we find a modest difference in torques and accretion variability between 2D and 3D disk models. We find cavity precession rates to be appreciably faster in 3D than in 2D.

79 ASTRONOMY AND ASTROPHYSICS↗

Periodic Gamma-Ray Modulation of the Blazar PG 1553+113 Confirmed by Fermi-LAT and Multiwavelength Observations

A 2.1 yr periodic oscillation of the gamma-ray flux from the blazar PG 1553+113 has previously been tentatively identified in ∼7 yr of data from the Fermi Large Area Telescope. After 15 yr of Fermi sky-survey observations, doubling the total time range, we report >7 cycle gamma-ray modulation with an estimated significance of 4σ against stochastic red noise. Independent determinations of oscillation period and phase in the earlier and the new data are in close agreement (chance probability <0.01). Pulse timing over the full light curve is also consistent with a coherent periodicity. Multiwavelength new data from Swift X-Ray Telescope, Burst Alert Telescope, and UVOT, and from KAIT, Catalina Sky Survey, All-Sky Automated Survey for Supernovae, and Owens Valley Radio Observatory ground-based observatories as well as archival Rossi X-Ray Timing Explorer satellite-All Sky Monitor data, published optical data of Tuorla, and optical historical Harvard plates data are included in our work. Optical and radio light curves show clear correlations with the gamma-ray modulation, possibly with a nonconstant time lag for the radio flux. We interpret the gamma-ray periodicity as possibly arising from a pulsational accretion flow in a sub-parsec binary supermassive black hole system of elevated mass ratio, with orbital modulation of the supplied material and energy in the jet. Other astrophysical scenarios introduced include instabilities, disk and jet precession, rotation or nutation, and perturbations by massive stars or intermediate-mass black holes in polar orbit.

79 ASTRONOMY AND ASTROPHYSICS↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection and imaging of electric fields, using polarized neutrons

A method and corresponding apparatus are provided for measuring neutron spin precession in an electric field with high sensitivity suitable for practical applications in non-destructive testing, imaging, and the like. Production of a neutron beam with a polarization vector P is followed by transmitting the spin-polarized neutron beam through a sample region in which there is a target generating an electric field, polarization-analyzing the transmitted neutron beam with an analyzing direction orthogonal to P, detecting an intensity of the polarization-analyzed neutron beam; and mapping the detected neutron-beam intensity to a field-strength value for the target electric field.

Jau, Yuan-Yu↗

Muon g-2 Experiment

The Muon g-2 experiment probes the magnetic properties of the muon—a heavy sibling of the electron—in the search for new physics. Muon g-2 (pronounced gee-minus-two) is an international collaboration between Fermilab and dozens of labs and universities in seven countries. The Muon g-2 experiment studies the precession or “wobble” of muons when placed in a magnetic field. Based on what we already know about muons and other particles, scientists can predict with great precision the value of the muons’ wobble. If the experiment comes up with something different, it means that our current understanding of physics is incomplete, and it may indicate the presence of additional particles or hidden subatomic forces. It would open the door to exciting new realms of science.

Fermilab, Fermilab↗

Development of a portable high-T c spherical neutron polarimetry device at the Oak Ridge National Laboratory

Spherical neutron polarimetry is a powerful polarized neutron scattering technique used to determine complex magnetic structures which are only partly accessible by other methods. This technique measures the full neutron polarization change upon scattering from a sample by fully decoupling the incoming and outgoing neutron polarization with a zero-field chamber placed at the sample position. Recent advancements and testing are presented for a new spherical neutron polarimetry device utilizing high-T c superconducting YBCO films, PHiTPAD, at the High Flux Isotope Reactor at Oak Ridge National Laboratory. Furthermore, we introduce a conceptual design that utilizes wavelength-independent adiabatic transitions to adapt spherical neutron polarimetry for use with pulsed neutron sources, thereby expanding its potential applications in neutron scattering research.

47 OTHER INSTRUMENTATION↗

Spin echo small-angle neutron scattering using superconducting magnetic Wollaston prisms

Here, we show the implementation of superconducting magnetic Wollaston prisms for spin echo small-angle neutron scattering. Two calibration methods for the spin echo length are presented: one utilizing spin echo modulated small-angle neutron scattering and the other based on the neutron refraction by quartz wedge crystals. Our experimental results with polystyrene nano-particle colloids showcase the system’s efficacy in measuring both dilute and concentrated colloidal systems. Additionally, investigations into the pore diameter and pitch of a nano-porous alumina membrane demonstrate its capability in analyzing nano-porous materials. Furthermore, we discuss potential optimizations to further extend the accessible spin echo length.

47 OTHER INSTRUMENTATION↗

Large-Angle Rocking Beam Electron Diffraction of Large Unit Cell Crystals Using Direct Electron Detector

We report a large-angle rocking beam electron diffraction (LARBED) technique for electron diffraction analysis. Diffraction patterns are recorded in a scanning transmission electron microscope (STEM) using a direct electron detector with large dynamical range and fast readout. We use a nanobeam for diffraction and perform the beam double rocking by synchronizing the detector with the STEM scan coils for the recording. Using this approach, large-angle convergent beam electron diffraction (LACBED) patterns of different reflections are obtained simultaneously. By using a nanobeam, instead of a focused beam, the LARBED technique can be applied to beam-sensitive crystals as well as crystals with large unit cells. Here, this paper describes the implementation of LARBED and evaluates the performance using silicon and gadolinium gallium garnet crystals as test samples. We demonstrate that our method provides an effective and robust way for recording LARBED patterns and paves the way for quantitative electron diffraction of large unit cell and beam-sensitive crystals.

4DSTEM↗