Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Entanglement and the process of measuring the position of a quantum particle

We explore the entanglement-related features exhibited by the dynamics of a composite quantum system consisting of a particle and an apparatus (here referred to as the “pointer”) that measures the position of the particle. We consider measurements of finite duration, and also the limit case of instantaneous measurements. We investigate the time evolution of the quantum entanglement between the particle and the pointer, with special emphasis on the final entanglement associated with the limit case of an impulsive interaction. We consider entanglement indicators based on the expectation values of an appropriate family of observables, and also an entanglement measure computed on particular exact analytical solutions of the particle–pointer Schrödinger equation. The general behavior exhibited by the entanglement indicators is consistent with that shown by the entanglement measure evaluated on particular analytical solutions of the Schrödinger equation. In the limit of instantaneous measurements the system’s entanglement dynamics corresponds to that of an ideal quantum measurement process. On the contrary, we show that the entanglement evolution corresponding to measurements of finite duration departs in important ways from the behavior associated with ideal measurements. In particular, highly localized initial states of the particle lead to highly entangled final states of the particle–pointer system. This indicates that the above mentioned initial states, in spite of having an arbitrarily small position uncertainty, are not left unchanged by a finite-duration position measurement process. - Highlights: • We explore entanglement features of a quantum position measurement. • We consider instantaneous and finite-duration measurements. • We evaluate the entanglement of exact time-dependent particle–pointer states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structured light scanning artifact-based performance study

Structured light scanning is used to create a digital twin of a manufactured part, where features are extracted to determine if the part meets the designer’s intent and required tolerances. This paper describes repeatability and reproducibility analyses for a commercially-available structured light scanning system and measurement artifact. The repeatability study used five repeated scans at 15 measurement positions. Repeatability was assessed by randomly selecting one of the five scans at each of the 15 positions and creating a part mesh. This process was performed 50 times and the statistics for the dimension variations were calculated to isolate the scanning effects only. The same sequence was then performed for 10 of the 15 positions and five of the 15 positions to evaluate the repeatability sensitivity to the number of measurement positions. Reproducibility was assessed by selecting 15 positions to create a mesh and repeating the 15-position measurement sequence 10 times using different positions for each mesh construction. The statistics for the dimension variations were then calculated. This incorporated the effects of both scanning and the position and orientation of the part relative to the scanner. This sequence was repeated for 10-position and five-position scans to evaluate the corresponding sensitivity. Finally, the artifact dimensions from structured light scanning were compared to coordinate measuring machine measurements of the same features.

42 ENGINEERING↗

SU-E-T-648: Quality Assurance Using the RADPOS System for 4D Radiotherapy with CyberKnife

Purpose: The CyberKnife robotic radiosurgery system uses Synchrony respiratory motion compensation, which requires independent performance verification. In this work, the RADPOS 4D dosimetry system’s motion measurements are compared with internal fiducial position measurements. In addition, RADPOS measurements are compared with Synchrony’s predictive correlation model, which is based on internal fiducial and external LED marker position measurements. Methods: A treatment plan was created for a lung insert containing fiducials, RADPOS detector, and Solid Water tumor phantom. Two Quasar Respiratory Motion Phantoms (Q1 and Q2) and two RADPOS detectors (R1 and R2) were used: Q1 simulated lung motion with a lung insert moving in the superior/inferior direction, while Q2 simulated chest motion with a chest platform moving in the anterior/posterior direction. Before treatment, R1 was secured inside of the tumor phantom within Q1, while LED markers and R2 were positioned on the chest platform of Q2. Two treatment delivery cases were studied: isocentric plan (I) and non-isocentric patient plan (P). Four motion cases were studied: no motion (0), sinusoidal and in-phase (1), sinusoidal and out-of-phase (2), patient waveform and out-of-phase (3). A coordinate alignment algorithm was implemented, allowing RADPOS and model position data to be compared within the fiducial coordinate system. Results: The standard deviation of the differences between RADPOS and fiducial position measurements was below 0.6 mm for all experimental cases. The standard deviation of the differences between RADPOS and model position data was 1.0, 1.5, and 1.6 mm along the primary direction of motion for case I1, I2, and P3, respectively. Conclusion: Our work demonstrates that RADPOS is a useful tool for independent quality assurance of CyberKnife treatment with Synchrony respiratory compensation. RADPOS and fiducial position measurement closely match, and RADPOS confirms the effectiveness of CyberKnife’s Synchrony motion tracking. This work was supported by OCAIRO (Ontario Consortium for Adaptive Interventions in Radiation Oncology) grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-16A-01: In Vivo Source Position Verification in High Dose Rate (HDR) Prostate Brachytherapy Using a Flat Panel Imager: Initial Clinical Experience

Purpose: We report our initial clinical experience with a novel position-sensitive source-tracking system based on a flat panel imager. The system has been trialled with 4 prostate HDR brachytherapy patients (8 treatment fractions) in this initial study. Methods: The flat panel imaging system was mounted under a customised carbon fibre couch top assembly (Figure 1). Three gold fiducial markers were implanted into the prostate of each patient at the time of catheter placement. X-ray dwell position markers were inserted into three catheters and a radiograph acquired to locate the implant relative to the imaging device. During treatment, as the HDR source dwells were delivered, images were acquired and processed to determine the position of the source in the patient. Source positions measured by the imaging device were compared to the treatment plan for verification of treatment delivery. Results: Measured dwell positions provided verification of relative dwell spacing within and between catheters, in the coronal plane. Measurements were typically within 2.0mm (0.2mm – 3.3mm, s.d. 0.8mm) of the planned positions over 60 dwells (Figure 2). Discrimination between larger dwell intervals and catheter differentiation were clear. This confirms important delivery attributes such as correct transfer tube connection, source step size, relative catheter positions and therefore overall correct plan selection and delivery. The fiducial markers, visible on the radiograph, provided verification of treatment delivery to the correct anatomical location. The absolute position of the dwells was determined by comparing the measured dwell positions with the x-ray markers from the radiograph, validating the programmed treatment indexer length. The total impact on procedure time was less than 5 minutes. Conclusion: The novel, noninvasive HDR brachytherapy treatment verification system was used clinically with minor impact on workflow. The system allows verification of correct treatment delivery, free of most potential human related errors identified in ICRP 97. This research is supported by funding from the Australian Government Department of Health through Cancer Australia grant no. 616614.

60 APPLIED LIFE SCIENCES↗

A Two Bunch Beam Position Monitor

A new beam position monitor digitizer module has been designed, tested and tuned at SLAC. This module, the electron-positron beam position monitor (epBPM), measures position of single electron and positron bunches for the SLC, LINAC, PEPII injections lines and final focus. The epBPM has been designed to improve resolution of beam position measurements with respect to existing module and to speed feedback correction. The required dynamic range is from 5 x 10{sup 8} to 10{sup 11} particles per bunch (46dB). The epBPM input signal range is from {+-}2.5 mV to {+-}500 mV. The pulse-to-pulse resolution is less than 2 {mu}m for 5 x 10{sup 10} particles per bunch for the 12 cm long striplines, covering 30{sup o} at 9 mm radius. The epBPM module has been made in CAMAC standard, single width slot, with SLAC type timing connector. 45 modules have been fabricated. The epBPM module has four input channels X{sup +}, X{sup -}, Y{sup +}, Y{sup -} (Fig. 1), named to correspond with coordinates of four striplines - two in horizontal and two in vertical planes, processing signals to the epBPM inputs. The epBPM inputs are split for eight signal processing channels to catch two bunches, first - the positron, then the electron bunch in one cycle of measurements. The epBPM has internal and external trigger modes of operations. The internal mode has two options - with or without external timing, catching only first bunch in the untimed mode. The epBPM has an on board calibration circuit for measuring gain of the signal processing channels and for timing scan of programmable digital delays to synchronize the trigger and the epBPM input signal's peak. There is a mode for pedestal measurements. The epBPM has 3.6 {mu}s conversion time.

43 PARTICLE ACCELERATORS↗

Monocular Video Measurement Of Position And Orientation

Monocular video imaging and image-data-processing system views robotic vehicle and measures position and orientation of vehicle in terms of position and orientation of colored cylinder mounted on vehicle. Data-processing subsystem determines position of cylinder from viewing angle and size of colored cylinder in image. System also follows innovative approach in determining orientation of cylinder.

Volpe, Richard A.↗

Positional repeatability measurements of stepper motors at cryogenic temperatures

For cryogenically-cooled infrared instruments and telescopes employed in space, reliable and predictable motor operations at 4 K in vacuum are in most cases necessary. For the Shuttle Infrared Telescope Facility (SIRTF), stepper motors may be employed in a number of applications. A test facility was designed and built for measuring stepper motor positional repeatability, in vacuum, over a temperature range from ambient to liquid helium temperature. Tests regarding positional repeatability were conducted at different motor speeds, directions of motor rotation, step sizes, and power conditions. In addition, tests were performed with respect to the ability of the motor to remain in a position with no power applied to the motor.

Pompea, S. M.↗

Calculation of the electron two slit experiment using a quantum mechanical variational principle

A nonlocal relativistic variational principle (VP) has recently been proposed as an alternative to the Dirac wave equation of standard quantum mechanics. We apply that principle to the electron two-slit experiment. The detection system is modelled as a screen made of atoms, any one of which can be excited by the incident electron, but we avoid restricting the detection mechanism further. The VP is shown to predict that, at the time the electron reaches the screen, its wavefunction will be localized to the neighborhood of a single atom, resulting in a position-type measurement. In an ensemble of such experiments ('identically prepared' except that the initial phase of the wavefunction - the hidden variable in the VP formulation - is sampled over the expected uniform distribution), the distribution of measured positions will reproduce the interference pattern predicted by the Dirac equation. We also demonstrate that with a detection system designed fundamentally to detect the electron's transverse wavelength rather than its position, the VP predicts that one such mode will be detected, that is, a wavelength measurement will result. Finally, it is shown that these results are unchanged in the 'delayed choice' variant of the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sonoluminescence Bubble Measurements using Vision-Based Algorithms

Vision-based measurement methods were used to measure bubble sizes in this sonoluminescence experiment. Bubble imaging was accomplished by placing the bubble between a bright light source and a microscope-CCD camera system. A collimated light-emitting diode was operated in a pulsed model with an adjustable time delay with respect to the piezo-electric transducer drive signal. The light-emitting diode produced a bubble shadowgraph consisting of a multiple exposure made by numerous light pulses imaged onto a charge-couple device camera. Each image was transferred from the camera to a computer-controlled machine vision system via a frame grabber. The frame grabber was equipped with on-board memory to accomodate sequential image buffering while images were transferred to the host processor and analyzed. This configuration allowed the host computer to perform diameter measurements, centroid position measurements and shape estimation in "real-time" as the next image was being acquired. Bubble size measurement accuracy with an uncertainty of 3 microns was achieved using standard lenses and machine vision algorithms. Bubble centroid position accuracy was also within the 3 micron tolerance of the vision system. This uncertainty estimation accounted for the optical spatial resolution, digitization errors and the edge detection algorithm accuracy. The vision algorithms include camera calibration, thresholding, edge detection, edge position determination, distance between two edges computations and centroid position computations.

Hall, Nancy R.↗

A TRIGONOMETRIC PARALLAX OF Sgr B2

We have measured the positions of H{sub 2}O masers in Sgr B2, a massive star-forming region in the Galactic center, relative to an extragalactic radio source with the Very Long Baseline Array. The positions measured at 12 epochs over a time span of one year yield the trigonometric parallax of Sgr B2 and hence a distance to the Galactic center of R {sub 0} = 7.9{sup +0.8} {sub -0.7} kpc. The proper motion of Sgr B2 relative to Sgr A* suggests that Sgr B2 is approx0.13 kpc nearer than the Galactic center, assuming a low-eccentricity Galactic orbit.

79 ASTRONOMY AND ASTROPHYSICS↗

Isgur-Wise functions and unitary representations of the Lorentz group: The baryon case j=0

We propose a group theoretical method to study Isgur-Wise (IW) functions. A current matrix element splits into a heavy quark matrix element and an overlap of the initial and final clouds, related to the IW functions, that contain the long distance physics. The light cloud belongs to the Hilbert space of a unitary representation of the Lorentz group. Decomposing into irreducible representations one obtains the IW function as an integral formula, superposition of irreducible IW functions with positive measures, providing positivity bounds on its derivatives. Our method is equivalent to the sum rule approach, but sheds another light on the physics and summarizes and gives all its possible constraints. We expose the general formalism, thoroughly applying it to the case j=0 for the light cloud, relevant to the semileptonic decay {lambda}{sub b}{yields}{lambda}{sub c}l{nu}{sub l}. In this case, the principal series of the representations contribute, and also the supplementary series. We recover the bound for the curvature of the j=0 IW function {xi}{sub {lambda}}(w) that we did obtain from the sum rule method, and we get new bounds for higher derivatives. We demonstrate also that if the lower bound for the curvature is saturated, then {xi}{sub {lambda}}(w) is completely determined, given by an explicit elementary function. We give criteria to decide if any Ansatz for the Isgur-Wise function is compatible or not with the sum rules. We apply the method to some simple model forms proposed in the literature. Dealing with a Hilbert space, the sum rules are convergent, but this feature does not survive hard gluon radiative corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on Pacific plate kinematics and dynamics with global positioning system measurements

A measurement program designed to investigate kinematic and dynamic aspects of plate tectonics in the Pacific region by means of satellite observations is proposed. Accuracy studies are summarized showing that for short baselines (less than 100 km), the measuring accuracy of global positioning system (GPS) receivers can be in the centimeter range. For longer baselines, uncertainty in the orbital ephemerides of the GPS satellites could be a major source of error. Simultaneous observations at widely (about 300 km) separated fiducial stations over the Pacific region, should permit an accuracy in the centimeter range for baselines of up to several thousand kilometers. The optimum performance level is based on the assumption of that fiducial baselines are known a priori to the centimeter range. An example fiducial network for a GPS study of the South Pacific region is described.

Dixon, T. H.↗

Technique for the focal-length measurement of positive lenses using Fizeau interferometry

We present what we believe is a new technique for the focal-length measurement of positive lenses using Fizeau interferometery. The technique utilizes the Gaussian lens equation. The image distance is measured interferometrically in terms of the radius of curvature of the image-forming wavefront emerging from the lens. The radii of curvature of the image-forming wavefronts corresponding to two different axial object positions of known separation are measured. The focal length of the lens is determined by solving the equations obtained using the Gaussian lens equation for the two object positions. Results obtained for a corrected doublet lens of a nominal focal length of 200.0 mm with a measurement uncertainty of {+-}2.5% is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-daily resolution of earth rotation variations with Global Positioning System measurements

Data from a worldwide Global Positioning System (GPS) tracking experiment have been used to determine variations in earth rotation (UT1-UTC) over a time period of three weeks. Kalman filtering and smoothing enabled changes in UT1-UTC over intervals of 2 to 24 hrs to be detected with the GPS data. Internal consistency checks and comparisons with other solutions from very long baseline interferometry (VLBI) and satellite laser ranging (SLR) indicate that the GPS UT1-UTC estimates are accurate to about 2 cm. Comparison of GPS-estimated variations in UT1-UTC with 2-hr time resolution over 4 days with predicted variations computed from diurnal and semidiurnal oceanic tidal contributions strongly suggests that the observed periodic sub-daily variations of about 0.1 msec are largely of tidal origin.

Lichten, Stephen M.↗

Locations of solar radio bursts

Measurements of the positions of the sources of solar radio bursts at decameter wavelengths, 20- to 60-MHz range, provide information about physical conditions in a region of the corona extending from about one-half to several solar radii from the surface of the sun. Position measurements in the 20- to 60-MHz range were made with the Clark Lake sweep-frequency grating interferometer. Although the resolution of the instrument is sufficient to measure source position accurately, the highly variable effect of refraction in the earth's ionosphere severely limits the observations, distorting position determinations to such an extent as to make much of the position data useless unless ionospheric refraction can be taken into account. A method was developed for the removal of the refractive effect from the data to permit determination of true source position. With this technique it is considered possible to measure spatial extent of radio sources that will provide information about emission processes and physical parameters in the corona.

Fitzenreiter, R.↗

Measuring Fiber Positioning Accuracy and Throughput with Fiber Dithering for the Dark Energy Spectroscopic Instrument

Highly multiplexed, fiber-fed spectroscopy is enabling surveys of millions of stars and galaxies. The performance of these surveys depends on accurately positioning fibers in the focal plane to capture target light. We describe a technique to measure the positioning accuracy of fibers by dithering fibers slightly around their ideal locations. This approach also enables measurement of the total system throughput and point-spread function delivered to the focal plane. We then apply this technique to observations from the Dark Energy Survey Instrument (DESI), and demonstrate that DESI positions fibers to within 0farcs08 of their targets (5% of a fiber diameter) and achieves a system throughput within about 7% of expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of positive direct current corona pulse in coaxial wire-cylinder gap

In this paper, a system is designed and developed to measure the positive corona current in coaxial wire-cylinder gaps. The characteristic parameters of corona current pulses, such as the amplitude, rise time, half-wave time, and repetition frequency, are statistically analyzed and a new set of empirical formulas are derived by numerical fitting. The influence of space charges on corona currents is tested by using three corona cages with different radii. A numerical method is used to solve a simplified ion-flow model to explain the influence of space charges. Based on the statistical results, a stochastic model is developed to simulate the corona pulse trains. And this model is verified by comparing the simulated frequency-domain responses with the measured ones.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗