Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POROSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evolution of porosity and diffusivity associated with chemical weathering of a basalt clast

Weathering of rocks as a result of exposure to water and the atmosphere can cause significant changes in their chemistry and porosity. In low-porosity rocks, such as basalts, changes in porosity, resulting from chemical weathering, are likely to modify the rock's effective diffusivity and permeability, affecting the rate of solute transport and thus potentially the rate of overall weathering to the extent that transport is the rate limiting step. Changes in total porosity as a result of mineral dissolution and precipitation have typically been used to calculate effective diffusion coefficients through Archie's law for reactive transport simulations of chemical weathering, but this approach fails to account for unconnected porosity that does not contribute to transport. In this study, we combine synchrotron X-ray microcomputed tomography ({mu}CT) and laboratory and numerical diffusion experiments to examine changes in both total and effective porosity and effective diffusion coefficients across a weathering interface in a weathered basalt clast from Costa Rica. The {mu}CT data indicate that below a critical value of {approx}9%, the porosity is largely unconnected in the basalt clast. The {mu}CT data were further used to construct a numerical pore network model to determine upscaled, effective diffusivities as a function of total porosity (ranging from 3 to 30%) for comparison with diffusivities determined in laboratory tracer experiments. By using effective porosity as the scaling parameter and accounting for critical porosity, a model is developed that accurately predicts continuum-scale effective diffusivities across the weathering interface of the basalt clast.

54 ENVIRONMENTAL SCIENCES↗

Effect of porosity, tissue density, and mechanical properties on radial sound speed in human cortical bone

Purpose: The purpose of this study was to investigate the effect of simultaneous changes in cortical porosity, tissue mineral density, and elastic properties on radial speed of sound (SOS) in cortical bone. The authors applied quantitative pulse-echo (PE) ultrasound techniques that hold much potential especially for screening of osteoporosis at primary healthcare facilities. Currently, most PE measurements of cortical thickness, a well-known indicator of fracture risk, use a predefined estimate for SOS in bone to calculate thickness. Due to variation of cortical bone porosity, the use of a constant SOS value propagates to an unknown error in cortical thickness assessment by PE ultrasound. Methods: The authors conducted 2.25 and 5.00 MHz focused PE ultrasound time of flight measurements on femoral diaphyses of 18 cadavers in vitro. Cortical porosities of the samples were determined using microcomputed tomography and related to SOS in the samples. Additionally, the effect of cortical bone porosity and mechanical properties of the calcified matrix on SOS was investigated using numerical finite difference time domain simulations. Results: Both experimental measurements and simulations demonstrated significant negative correlation between radial SOS and cortical porosity (R{sup 2} ≥ 0.493, p < 0.01 and R{sup 2} ≥ 0.989, p < 0.01, respectively). When a constant SOS was assumed for cortical bone, the error due to variation of cortical bone porosity (4.9%–16.4%) was about 6% in the cortical thickness assessment in vitro. Conclusions: Use of a predefined, constant value for radial SOS in cortical bone, i.e., neglecting the effect of measured variation in cortical porosity, propagated to an error of 6% in cortical thickness. This error can be critical as characteristic cortical thinning of 1.10% ± 1.06% per yr decreases bending strength of the distal radius and results in increased fragility in postmenopausal women. Provided that the cortical porosity can be estimated in vivo, the relationship between radial SOS and cortical porosity can be utilized and a porosity based radial SOS estimate could be implemented to determine cortical thickness. This would constitute a step toward individualized quantitative ultrasound diagnostics of osteoporosis.

60 APPLIED LIFE SCIENCES↗

Wave propagation speeds and source term influences in single and integral porosity shallow water equations

In urban flood modeling, so-called porosity shallow water equations (PSWEs), which conceptually account for unresolved structures, e.g., buildings, are a promising approach to addressing high CPU times associated with state-of-the-art explicit numerical methods. The PSWE can be formulated with a single porosity term, referred to as the single porosity shallow water model (SP model), which accounts for both the reduced storage in the cell and the reduced conveyance, or with two porosity terms: one accounting for the reduced storage in the cell and another accounting for the reduced conveyance. The latter form is referred to as an integral or anisotropic porosity shallow water model (AP model). The aim of this study was to analyze the differences in wave propagation speeds of the SP model and the AP model and the implications of numerical model results. First, augmented Roe-type solutions were used to assess the influence of the source terms appearing in both models. It is shown that different source terms have different influences on the stability of the models. Second, four computational test cases were presented and the numerical models were compared. It is observed in the eigenvalue-based analysis as well as in the computational test cases that the models converge if the conveyance porosity in the AP model is close to the storage porosity. If the porosity values differ significantly, the AP model yields different wave propagation speeds and numerical fluxes from those of the BP model. In this study, the ratio between the conveyance and storage porosities was determined to be the most significant parameter.

58 GEOSCIENCES↗

A deep learning framework for layer-wise porosity prediction in metal powder bed fusion using thermal signatures

Abstract Part quality manufactured by the laser powder bed fusion process is significantly affected by porosity. Existing works of process–property relationships for porosity prediction require many experiments or computationally expensive simulations without considering environmental variations. While efforts that adopt real-time monitoring sensors can only detect porosity after its occurrence rather than predicting it ahead of time. In this study, a novel porosity detection-prediction framework is proposed based on deep learning that predicts porosity in the next layer based on thermal signatures of the previous layers. The proposed framework is validated in terms of its ability to accurately predict lack of fusion porosity using computerized tomography (CT) scans, which achieves a F1-score of 0.75. The framework presented in this work can be effectively applied to quality control in additive manufacturing. As a function of the predicted porosity positions, laser process parameters in the next layer can be adjusted to avoid more part porosity in the future or the existing porosity could be filled. If the predicted part porosity is not acceptable regardless of laser parameters, the building process can be stopped to minimize the loss.

42 ENGINEERING↗

X-ray computed tomography-based porosity analysis: Algorithms and application for porous woody biomass

The properties of lignocellulosic biomass, such as bulk physical, thermal, and mechanical properties, as well as the mobility of enzymes or catalysts, are largely affected by porosity, pore structures, and pore size distribution. While X-ray computed tomography (CT) has been introduced to effectively produce 3D volumetric images of material microstructure, a quantitative porosity analysis from the 3D images has never been done. This work introduces a first-of-its-kind X-ray CT-based quantitative porosity analysis method and applies the developed toolkit to characterize the internal porosity distribution of loblolly pine. A sample loblolly pine chip was scanned by a nano-resolution X-ray CT system and digitally reconstructed after a sequence of image processing operations. Here, a comprehensive porosity analysis was then performed to quantify the envelope porosity, the spatial distribution of local porosity, and the directional porosity. Solutions to the various challenges in image processing, porosity calculation, and large data handling are provided.

42 ENGINEERING↗

Porosity as a function of stoichiometry and implantation temperature in Ge/Si{sub 1−x}Ge{sub x} alloys

The development of porosity in single-crystal germanium and silicon-germanium alloys (c-Si{sub 1−x} Ge{sub x}) of (100) orientation was studied under bombardment with 140 keV Ge{sup −} ions over a wide range of temperatures (−180 to 400 °C) and ion fluences up to 1 × 10{sup 18} ions/cm{sup 2}. The surface swelling and morphology were investigated using multi-characterization techniques including optical profilometry, transmission electron microscopy, and scanning electron microscopy. The initiation of porosity and the evolution of the near-surface microstructure strongly depend on the ion fluence, the irradiation temperature, and the stoichiometry of the substrate. Significant results and new findings include: (i) the fact that, over the entire temperature and stoichiometry range, porosity is only developed once the substrate is rendered amorphous; (ii) with increasing Si content in the alloy, the onset of porosity is pushed to higher fluences; (iii) porosity is observed for Si contents in the alloy up to 23% but not higher under the irradiation conditions used; and (iv) in all cases the initiation of porosity was observed to occur at the surface of the amorphous alloy above a threshold fluence. This last result strongly suggests that the mechanism for initiation of porosity is via preferential vacancy segregation and clustering at the surface of the amorphous alloy. Particularly at elevated temperatures, preferential sputtering of the Si-Ge atomic species in the alloy also plays an important role in developing the surface topography and porosity in alloys. Such effects are discussed along with the implications of our results for mechanisms of porosity in Ge and its alloys.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CONSTRAINTS ON POROSITY AND MASS LOSS IN O-STAR WINDS FROM THE MODELING OF X-RAY EMISSION LINE PROFILE SHAPES

We fit X-ray emission line profiles in high resolution XMM-Newton and Chandra grating spectra of the early O supergiant {zeta} Pup with models that include the effects of porosity in the stellar wind. We explore the effects of porosity due to both spherical and flattened clumps. We find that porosity models with flattened clumps oriented parallel to the photosphere provide poor fits to observed line shapes. However, porosity models with isotropic clumps can provide acceptable fits to observed line shapes, but only if the porosity effect is moderate. We quantify the degeneracy between porosity effects from isotropic clumps and the mass-loss rate inferred from the X-ray line shapes, and we show that only modest increases in the mass-loss rate ({approx}< 40%) are allowed if moderate porosity effects (h{sub {infinity}} {approx}< R{sub *}) are assumed to be important. Large porosity lengths, and thus strong porosity effects, are ruled out regardless of assumptions about clump shape. Thus, X-ray mass-loss rate estimates are relatively insensitive to both optically thin and optically thick clumping. This supports the use of X-ray spectroscopy as a mass-loss rate calibration for bright, nearby O stars.

79 ASTRONOMY AND ASTROPHYSICS↗

EFFECTIVE POROSITY IMPLIES EFFECTIVE BULK DENSITY IN SORBING SOLUTE TRANSPORT

The concept of an effective porosity is widely used in solute transport modeling to account for the presence of a fraction of the medium that effectively does not influence solute migration, apart from taking up space. This non-participating volume or ineffective porosity plays the same role as the gas phase in single-phase liquid unsaturated transport: it increases pore velocity, which is useful towards reproducing observed solute travel times. The prevalent use of the effective porosity concept is reflected by its prominent inclusion in popular texts, e.g., de Marsily (1986), Fetter (1988, 1993) and Zheng and Bennett (2002). The purpose of this commentary is to point out that proper application of the concept for sorbing solutes requires more than simply reducing porosity while leaving other material properties unchanged. More specifically, effective porosity implies the corresponding need for an effective bulk density in a conventional single-porosity model. The reason is that the designated non-participating volume is composed of both solid and fluid phases, both of which must be neglected for consistency. Said another way, if solute does not enter the ineffective porosity then it also cannot contact the adjoining solid. Conceptually neglecting the fluid portion of the non-participating volume leads to a lower (effective) porosity. Likewise, discarding the solid portion of the non-participating volume inherently leads to a lower or effective bulk density. In the author's experience, practitioners virtually never adjust bulk density when adopting the effective porosity approach.

99 GENERAL AND MISCELLANEOUS↗

Saturated hydraulic conductivity and porosity within macroaggregates modified by tillage

Greater knowledge of intraaggregate porosity modifications by tillage conveys new information for identifying additional hydrologic, ion retention, and aggregate stability responses to specific management practices. Macroaggregates, 2 to 4, 4 to 6.3, and 6.3 to 9.5 mm across, were separated into multiple concentric layers and their porosities were determined. Saturated hydraulic conductivity (K{sub s}) of multiple aggregate fractions from two soil types subjected to conventional tillage (CT), no tillage (NT), and native forest (NF) soils were measured individually to identify the effects of tillage on aggregate structure, porosity, and K{sub s}. Intraaggregate porosities were the highest in NF aggregates. Greater porosities were identified in exterior layers of soil aggregates from all treatments. Lowest intraaggregate porosities were observed in the central regions of CT aggregates. Soil aggregates, 6.3 to 9.5 mm across, had the greatest total porosities, averaging 37.5% for both soil types. Long-term CT reduced intraaggregate porosities and K, within macroaggregates, of the same size fraction, from both the Hoytville silty clay loam and Wooster silt loam soil types. Values for K, of NF aggregates, 5.0 x 10{sup -5} cm s{sup -1}, were reduced 50-fold by long-term CT treatments of the Hoytville series. The K, values through Wooster aggregates from NF, 16.0 x 10{sup -5} cm s{sup -1}, were reduced 80-fold by long-term CT treatments. The K{sub s} values through NF and NT aggregates were positively correlated with their intraaggregate porosities (R{sup 2} = 0.84 for NF and R{sup 2} = 0.45 for NT at P < 0.005). Additional studies are needed to identify rates at which pore geometries within macroaggregates are degraded by CT or improved by NT.

54 ENVIRONMENTAL SCIENCES↗

The Effect of Ar and N 2 Shielding Gas on Laser Weld Porosity in Steel, Stainless Steel, and Nickel

Complete, or near complete, elimination of porosity in 304L stainless steel keyhole laser welds was observed when using N2 instead of Ar shielding gas. Partial penetration autogeneous welds made at intermediate power levels of 2-4 kW using a CW fiber laser at travel speeds of 8-11 mm/s where porosity often occurs when using inert shielding gas. To investigate this effect further, laser welds were made in N 2 and Ar gas on three additional metals (A36 steel, 21-6-9 stainless steel, and pure nickel) that have varying properties and degrees of reactivity and solubilities with the shielding gasses. Optical metallography, x-ray radiography, and x-ray computed tomography were used to characterize the porosity levels in the welds. Results show that high levels of porosity occurred in nickel, regardless of shielding gas type, while low levels or no porosity was observed in 21-6-9 for either shielding gas. However, A36 and 304L exhibited porosity in all of the welds made with Ar, and very low or no porosity when made with N2. Computed tomography was used to quantify the porosity in selected welds, showing that the pore sizes are distributed in a monotonically decreasing trend that can be described by a two parameter Weibull relationship (β=0.5429, α=0.0366). Based on the results, it is believed that the reactivity of N 2 with alloying elements, and/or its solubility in the liquid weld pool, play a significant role in reducing the amount of retained porosity in unstable keyhole welds as they solidify and cool to room temperature.

Steel↗

Investigation on porosity and permeability change of Mount Simon sandstone (Knox County, IN, USA) under geological CO 2 sequestration conditions: a numerical simulation approach

In this paper, a numerical model was developed to simulate reactive transport with porosity and permeability change of Mount Simon sandstone (samples from Knox County, IN) after 180 days of exposure to CO 2 -saturated brine under CO 2 sequestration conditions. The model predicted formation of a high-porosity zone adjacent to the surface of the sample in contact with bulk brine, and a lower porosity zone just beyond that high-porosity zone along the path from sample/bulk brine interface to sample core. The formation of the high porosity zone was attributed to dissolution of quartz and muscovite/illite, while the formation of the lower porosity zone adjacent to the aforementioned high porosity zone was attributed to precipitation of kaolinite and feldspar. The model predicted a 40% permeability increase for the Knox sandstone sample after 180 days of exposure to CO 2 -saturated brine, which was consistent with laboratory-measured permeability results. Model-predicted solution chemistry results were also found to be consistent with laboratory-measured solution chemistry data. Finally, initial porosity, initial feldspar content and the exponent n value (determined by pore structure and tortuosity) used in permeability calculations were three important factors affecting permeability evolution of sandstone samples under CO 2 sequestration conditions.

54 ENVIRONMENTAL SCIENCES↗

Multiscale porosity characterization in additively manufactured polymer nanocomposites using micro-computed tomography

Extrusion-based additive manufacturing (AM) of polymer composites exhibits complex thermally driven phenomena that introduce severe discontinuities in the internal structure across length scales, especially voids or porosity. This study utilizes a high-throughput porosity characterization technique to analyze large datasets from numerous micro-computed tomography (mu CT) scans to capture the influence of AM print parameters on the size, shape, and location of porosity across multiple print layers (up to a few cm) on fused granular fabrication (FGF) printers. The materials investigated include nanocomposite formulations based on commercially relevant nylon-12 and polyether ketone ketone (PEKK) materials comprising nano- or micro- sized fillers. The estimated global porosity follows an inverse linear correlation against the bulk density of the printed samples. Increasing the extrusion multiplier (EM) and the nozzle temperature while decreasing the print speeds reduces the global porosity. Outlier analyses (local porosity morphology) show that faster print speeds and higher extrusion rates result in long, slender inter-layer voids, while lower nozzle temperatures lead to large, symmetrical, inter-bead voids (at the bead junction). Lack of active chamber temperature increases inter-layer and intra-bead voids with a two-fold increase in global porosity. Overall, the micro filler-reinforced composites exhibit higher global porosity than nanofiller-reinforced composites, which is attributed to the increased mismatch in the thermal expansion coefficient between the filler and the polymers used in the study.

36 MATERIALS SCIENCE↗

The porosity surrounding carbides and second phase stringers in monolithic U-10Mo fuel plate after irradiation

Post-irradiation microstructure characterization plays an important role in qualifying the low-enriched uranium (LEU) monolithic U-10 wt%Mo plate-type fuel for United States high-performance research reactors (USHPRRs) program. Inhomogeneous features resulting from manufacturing and irradiation processes, including carbides, second phase stringers, and extensive void spaces caused by the combining of small porosities, may increase the risk of heat concentration in local regions of the fuel plate over the operating conditions. In this study, characteristics of carbides, stringers, and porosity after multiple levels of irradiation at varying fission densities were studied by electron microscopes to decipher the morphology of pores and the porosity evolution in U-10 wt%Mo. For carbides, the result shows that porosities start forming on UMo grain boundaries, then on UMo/carbides interfaces as the burn-up going higher. However, the porosities surrounding carbides grow larger than the ones on UMo grain boundaries. The porosities around the uranium carbides could interconnect to form larger void space. The study revealed that the void spaces larger than 5 µm were found around uranium carbides after high burnup, while no evidence was observed to support the similar voids formed near second phase stringers even though the size of the stringers (> 50 µm) was much larger than uranium carbides (< 20 µm). The evolution of porosities suggests that the formation of second phase stringers may not create more significant porosities compared to regular uranium carbides regions during fuel operating conditions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Properties of Bulk Sintered Silver As a Function of Porosity

This report summarizes a study where various properties of bulk-sintered silver were investigated over a range of porosity. This work was conducted within the National Transportation Research Center's Power Device Packaging project that is part of the DOE Vehicle Technologies Advanced Power Electronics and Electric Motors Program. Sintered silver, as an interconnect material in power electronics, inherently has porosity in its produced structure because of the way it is made. Therefore, interest existed in this study to examine if that porosity affected electrical properties, thermal properties, and mechanical properties because any dependencies could affect the intended function (e.g., thermal transfer, mechanical stress relief, etc.) or reliability of that interconnect layer and alter how its performance is modeled. Disks of bulk-sintered silver were fabricated using different starting silver pastes and different sintering conditions to promote different amounts of porosity. Test coupons were harvested out of the disks to measure electrical resistivity and electrical conductivity, thermal conductivity, coefficient of thermal expansion, elastic modulus, Poisson's ratio, and yield stress. The authors fully recognize that the microstructure of processed bulk silver coupons may indeed not be identical to the microstructure produced in thin (20-50 microns) layers of sintered silver. However, measuring these same properties with such a thin actual structure is very difficult, requires very specialized specimen preparation and unique testing instrumentation, is expensive, and has experimental shortfalls of its own, so the authors concluded that the herein measured responses using processed bulk sintered silver coupons would be sufficient to determine acceptable values of those properties. Almost all the investigated properties of bulk sintered silver changed with porosity content within a range of 3-38% porosity. Electrical resistivity, electrical conductivity, thermal conductivity, elastic modulus, Poisson's ratio, and yield stress all depended on the porosity content in bulk-sintered silver. The only investigated property that was independent of porosity in that range was coefficient of thermal expansion.

36 MATERIALS SCIENCE↗

The Effect of Reduced Pressure on Laser Keyhole Weld Porosity and Weld Geometry in Commercially Pure Titanium and Nickel

Here, the beneficial effect of reduced pressure laser welding in vacuum at 10 -1 mBar was investigated in commercially pure titanium and nickel and compared to atmospheric pressure welding in Ar shielding gas. Partial penetration keyhole welds were made in these materials using a continuous wave disk laser operating at 2-4 kW and travel speeds of 12 and 17 mm/s, where moderate to severe porosity is observed under normal atmospheric pressure welding conditions. Additional welds were made in nickel using an electron beam welding process and the same parameters for comparison. Optical metallography, x-ray radiography, and computed x-ray tomography (CT) were used to characterize the porosity levels in the welds. Quantitative CT results show a monotonically decreasing pore size distribution for all of the welds, and the distributions can be fit with a 2-parameter Wiebull relationship with a beta shape factor that varied between 0.37 and 0.61 depending on the welding conditions. Other results show that laser vacuum essentially eliminates porosity in titanium, and significantly reduces porosity in nickel, but does not completely eliminate porosity in nickel. Laser vacuum welds have increased keyhole penetration and reduced weld widths compared to their atmospheric pressure counterparts, with similar beneficial geometric weld shapes as electron beam welds that are also made in vacuum. Finally, laser vacuum welds showed approximately one-half the volumetric porosity in nickel than electron beam welds, with less porosity at the weld root.

36 MATERIALS SCIENCE↗

Deconvoluting the benefits of porosity distribution in layered electrodes on the electrochemical performance of Li-ion batteries

Thick Lithium Ion Battery (LIB) electrodes suffer from poor rate capability and high ionic impedance due to their thickness and mesostructure. Therefore, optimizing thick electrode architectures becomes crucial. In this work, we report a systematic assessment of the ionic resistance in heterogeneous porous electrodes through the combination of computational simulations using a 4D-resolved model and experimental measurements. The first part of the study is devoted to a general assessment of Electrochemical Impedance Spectroscopy (EIS) spectra, mapping the impact of ionic and electronic resistances on the overall impedances of uncalendered and calendered LiNi 1/3 Mn 1/3 Co 1/3 O 2 , LiFePO 4 and graphite electrodes. In the second part, in silico-generated electrodes with different porosities are used in computational EIS simulations to analyze the impact of the electrode porosity on the ionic impedance. As expected, the results show that a lower porosity leads to a higher ionic impedance because of a higher electrode tortuosity factor. Furthermore, in silico-generated electrodes with different porosities were stacked and assembled to create heterogeneities of porosity along the thickness, and used in computational EIS and galvanostatic discharge simulations. The computational results show that the porosity heterogeneity along the electrode thickness has a significant effect on the ionic impedance and capacity of the electrode. The electrode architecture with progressively decreasing porosity from separator to current collector shows the highest performance, a trend validated by our in house experimental EIS and galvanostatic discharge also reported in this manuscript. Overall, we conclude that the ionic resistance in a thick electrode can be effectively reduced through proper tuning of the porosity heterogeneity. The proposed heterogeneous electrode architectures presented here could enormously help building efficient thick electrodes for LIBs.

25 ENERGY STORAGE↗

The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

The presence of materials with high magnetic susceptibility are known to have an impact on 1H nuclear magnetic resonance (NMR) measurements and in laboratory data this often results in poor estimates of porosity from NMR data. To quantify and understand the cause of the poor NMR porosity estimations, in this laboratory study, we examine the effect of magnetic susceptibility, NMR measurement parameters, and NMR instrument design on NMR measurements. Data were collected with two instruments, each with a different Larmor frequency (2 MHz and 485 kHz), on water-saturated unconsolidated sediments with magnetic susceptibility values ranging from 3.6 × 10 -6 to 7020 × 10 -6 SI. The results show that for materials with low magnetic susceptibility (<378 × 10 -6 SI), the gravimetric porosity is accurately predicted from the NMR measurements. For the samples with high magnetic susceptibility (>987 × 10 -6 SI) the gravimetric porosity is poorly predicted from the 2 MHz NMR measurements made at all echo times (from 0.2 to 3.0 ms). In contrast, the gravimetric porosity is more accurately predicted at an echo time of 0.2 ms for measurements made using the 485 kHz instrument, although at larger echo times (>1.0 ms), the porosity estimate becomes poor. The 485 kHz NMR instrument has non-zero internal magnetic field gradients, similar to those found in borehole instruments, in contrast to the 2 MHz NMR instrument, which has a homogeneous applied magnetic field. Finally, we conclude that differences is the magnetic field strength and higher magnetic field inhomogeneities in the 485 kHz NMR instrument contribute to a reduction of the impact of inhomogeneities in the magnetic field caused by materials with high magnetic susceptibility, allowing for improved porosity estimation. These results indicate that NMR measurements collected at short echo times in low, inhomogeneous static fields, e.g., borehole instruments, may provide accurate estimates of porosity in water saturated sediments, even in the presence of magnetic minerals.

58 GEOSCIENCES↗

Cold Spray NDE for Porosity and Other Process Anomalies

This paper describes a technology review of non-destructive examination (NDE) methods that can be applied to cold spray coatings. Cold spray is a process for depositing metal powder at high velocity so that it bonds to the substrate metal without significant heating that would be likely to cause additional residual tensile stresses. Coatings in the range from millimeters to centimeters are possible at relatively high deposition rates. Cold spray coatings that may be used for hydroelectric components that are subject to erosion, corrosion, wear, and cavitation damage are of interest. The topic of cold spray NDE is treated generally however and may be considered applicable to virtually any cold spray application except where there are constraints of the hydroelectric component application that bear special consideration. Hydroelectric turbine components are primarily made from low carbon and austenitic stainless steels. They are typically very large components that are partially assembled on-site. Transport of these components within the hydroelectric facility and away from the hydroelectric facility is challenging due to the component’s size and weight, high cost of disassembly, and the confined space of the dam. One method for prolonging component life is application of cold spray and thermal powder metal coatings to the components most susceptible to erosion, corrosion, cracking, and mechanical wear. Process controls and visual inspections have historically been applied to cold spray application; however, quantitative NDE could detect anomalies not readily apparent from such a visual examination. Optical profilometry, Eddy current, ultrasound, and hardness tests are shown for one set of good, fair, and poor Nickle-Chrome (NiCr) on 304 stainless steel (304SS) cold spray samples to demonstrate inspection possibilities. The primary indicator of cold spray quality is the cold spray porosity that is most directly measured with witness-sample destructive examinations (DE) – mostly photo-micrographs. These DE generated porosity values are correlated with optical profilometry, eddy current, ultrasound, and hardness test NDE methods to infer the porosity and other Information of interest. These parameters of interest primarily include: • Porosity primarily caused by improper process conditions (temperature, gas velocity, spray standoff, spray angle, powder size, condition, surface cleanliness, surface oxide, etc.). • Presence/absence of the cold spray coating including possible over-sprayed voids • Coating thickness Optical profilometry measurements of surface roughness trended with porosity plus if compared with a reference measurement or reference drawing would provide information on the coating thickness. Ultrasound could provide similar surface profile information plus attenuation measurements trended with porosity. The ultrasound measurements however may be limited to geometries where the substrate back-wall is normal to the cold spray surface and not too thick. Eddy current showed a strong correlation with porosity. Eddy currents can also be sensitive to cracks and do not need fluid coupling to make measurements. Eddy currents however are not sensitive to coating thicknesses in most cases. Vickers hardness measurements also tracked well with porosity. These types of hardness measurements however are also not sensitive to coating thickness. An NDE program may include multiple measurements. Acknowledgement: This work is sponsored by Bonneville Power Administration (BPA) under their technology innovation project program. Such support does not constitute BPA endorsement of views expressed in this work.

Glass, Samuel W.↗