Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUTONIUM 244”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

57 records · Page 4

Technical Review Report for the "Justification for Small Gram Quantity Contents" Safety Analysis Report for Packaging Model 9977-96, Addendum 3, S-SARA-G-00006, Revision 4

This Technical Review Report (TRR) summarizes the results of the Staff’s review of the Model 9977-96 Package, Addendum 3, Revision 4 for the Type 4 contents. Type 4 contents may include 238 Pu, 239 Pu, 241 Am, 244 Cm, 252 Cf, 90 Sr, 226 Ra, 137 Cs, 60 Co, 192 Ir with the Special Actinide Isotopes ( 242 mAm, 243 Cm, 245 Cm, 247 Cm, 249 Cf and 251 Cf) limited to a total of 1000 ppm. Type 4 pertains primarily to the Off-Site Source Recovery Project (OSRP). These new contents will be authorized for shipment in the Model 9977-96 Package, supplementing existing Revision 2 to the Safety Analysis Report for Packaging (SARP), once Addendum 3, Justification for Small Gram Quantity (SGQ) Contents, is accepted by the certifying official, EM-40, and the existing Certificate of Compliance (CoC) is revised, reflecting the added contents. Existing Content Envelopes for the Model 9977-96 Package include heat sources in food-pack cans or in radioisotope thermoelectric generators (RTGs), neptunium metal, a beryllium-reflected plutonium ball, plutonium/uranium metal at 25% and 50% maximum 240Pu, respectively, and uranium metal at limits of 95% and 100% 235U, respectively. The percentages are of total radioactive material mass. The Isentropic Compression Experiment (ICE) apparatus is an additional content of the Model 9977-96 Package SARP. The latest content added to the Model 9977-96 Package is Type 5, AGR fuel compacts. Addendum 3 was prepared by Savannah River Packaging Technology, Savannah River National Laboratory, Savannah River Nuclear Solutions, LLC, Savannah River Site, in support of work being performed by LANL. The Model 9977-96 Package is currently certified under two Certificate of Compliance Numbers, i.e., USA/9977/B(M)F-96 (DOE) and USA/9977/B(M)F-96 (DOE-S/T-1), covering transportation and periodic and extended maintenance, respectively. For transportation, the Safety Analysis Report for Packaging is S-SARP-G-0001, Revision 2 (August 2007). Extended maintenance is covered by Addendum 1, Justification for DNDO Contents, S-SARA-G-00003, Revision 2 (October 2008). The new Content Envelope and container configurations will be incorporated into the next revision to the Model 9977-96 Package SARP. This TRR addresses only Type 4 contents; content Types 1, 2, and 3 will be covered under a separate TRR. Content Type 5 has been dealt with in a previous TRR. Hereafter, in this TRR, the Type 4 content may be referred to as Sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

Independent Verification of Element 114 Production in the {sup 48}Ca+{sup 242}Pu Reaction

Independent verification of the production of element 114 in the reaction of 244-MeV {sup 48}Ca with {sup 242}Pu is presented. Two chains of time- and position-correlated decays have been assigned to {sup 286}114 and {sup 287}114. The observed decay modes, half-lives, and decay energies agree with published results. The measured cross sections at a center-of-target energy of 244 MeV for the {sup 242}Pu({sup 48}Ca,3-4n){sup 287,286}114 reactions were 1.4{sub -1.2}{sup +3.2} pb each, which are lower than the reported values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗