Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PLIF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

PLIF Temperature and Velocity Distributions in Laminar Hypersonic Flat-plate Flow

Rotational temperature and velocity distributions have been measured across a hypersonic laminar flat-plate boundary layer, using planar laser-induced fluorescence. The measurements are compared to a finite-volume computation and a first-order boundary layer computation, assuming local similarity. Both computations produced similar temperature distributions and nearly identical velocity distributions. The disagreement between calculations is ascribed to the similarity solution not accounting for leading-edge displacement effects. The velocity measurements agreed to within the measurement uncertainty of 2 % with both calculated distributions. The peak measured temperature was 200 K lower than the computed values. This discrepancy is tentatively ascribed to vibrational relaxation in the boundary layer.

OByrne, S.

Nitric Oxide PLIF Measurements in the Hypersonic Materials Environmental Test System (HYMETS)

A nonintrusive laser-based measurement system has been applied for the first time in the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. Planar laser-induced fluorescence of naturally occurring nitric oxide (NO) has been used to obtain instantaneous flow visualization images, and to make both radial and axial velocity measurements. Results are presented at selected facility run conditions, including some in simulated Earth atmosphere (75% nitrogen, 20% oxygen, 5% argon) and others in simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon), for bulk enthalpies ranging from 6.5 MJ/kg to 18.4 MJ/kg. Flow visualization images reveal the presence of large scale unsteady flow structures, and indicate nitric oxide fluorescence signal over more than 70% of the core flow for bulk enthalpies below about 11 MJ/kg, but over less than 10% of the core flow for bulk enthalpies above about 16 MJ/kg. Axial velocimetry was performed using molecular tagging velocimetry (MTV). Axial velocities of about 3 km/s were measured along the centerline. Radial velocimetry was performed by scanning the wavelength of the narrowband laser and analyzing the resulting Doppler shift. Radial velocities of 0.5km/s were measured.

Inman, Jennifer A.

Experimental Assessment and Enhancement of Planar Laser-Induced Fluorescence Measurements of Nitric Oxide in an Inverse Diffusion Flame

We have experimentally assessed the quantitative nature of planar laser-induced fluorescence (PLIF) measurements of NO concentration in a unique atmospheric pressure, laminar, axial inverse diffusion flame (IDF). The PLIF measurements were assessed relative to a two-dimensional array of separate laser saturated fluorescence (LSF) measurements. We demonstrated and evaluated several experimentally-based procedures for enhancing the quantitative nature of PLIF concentration images. Because these experimentally-based PLIF correction schemes require only the ability to make PLIF and LSF measurements, they produce a more broadly applicable PLIF diagnostic compared to numerically-based correction schemes. We experimentally assessed the influence of interferences on both narrow-band and broad-band fluorescence measurements at atmospheric and high pressures. Optimum excitation and detection schemes were determined for the LSF and PLIF measurements. Single-input and multiple-input, experimentally-based PLIF enhancement procedures were developed for application in test environments with both negligible and significant quench-dependent error gradients. Each experimentally-based procedure provides an enhancement of approximately 50% in the quantitative nature of the PLIF measurements, and results in concentration images nominally as quantitative as LSF point measurements. These correction procedures can be applied to other species, including radicals, for which no experimental data are available from which to implement numerically-based PLIF enhancement procedures.

Partridge, William P.

A Comparison of NO Laser-Induced Fluorescence Models at Conditions Relevant to Supersonic and Hypersonic Flows

Planar laser-induced fluorescence (PLIF) of the nitric oxide (NO) molecule has been widely used in wind tunnel facilities for flow visualization, velocity, and temperature measurements. The experimental PLIF measurements are often compared with synthetic PLIF images using computationally derived temperatures, pressures, velocities, and species mole fractions. This approach is commonly referred to as computational flow imaging (CFI). In the present work, we compare signal intensity from PLIF models with experimental PLIF measurements obtained within a low pressure gas cell system at pressures and NO mole fractions relevant to supersonic and hypersonic flowfields. Experimental measurements were compared to several different laser induced-fluorescence models reported in the literature including LIFBASE, LINUS, and a NASA two-level model. The experimental measurements agreed well with all of the models at lower pressures and lower NO mole fractions; the fluorescence there is linear with both of these parameters. However, at higher pressures and mole fractions, the signal becomes nonlinear with respect to these parameters as self-quenching limits the signal and absorption further limits the signal. In fact, for the experimental path length of the experiment, the combination of high pressure and high NO mole fraction causes the experimental results to deviate significantly from the predicted results that neglect absorption of the incident laser sheet. The LINUS model, which allows absorption to be calculated, provided results that agreed better with the experimental measurements. Since supersonic and hypersonic flowfields may contain a region of the flow with high pressures and measurements in large-scale facilities often include a long path length, neglecting absorption may have a significantly negative effect on the CFI comparison to experimental PLIF images. As a result, PLIF models that account for absorption should be included in computational flow imaging approaches for laser induced fluorescence.

laser-induced fluorescence

Multi-Dimensional Measurements of Combustion Species in Flame Tube and Sector Gas Turbine Combustors

The higher temperature and pressure cycles of future aviation gas turbine combustors challenge designers to produce combustors that minimize their environmental impact while maintaining high operation efficiency. The development of low emissions combustors includes the reduction of unburned hydrocarbons, smoke, and particulates, as well as the reduction of oxides of nitrogen (NO(x)). In order to better understand and control the mechanisms that produce emissions, tools are needed to aid the development of combustor hardware. Current methods of measuring species within gas turbine combustors use extractive sampling of combustion gases to determine major species concentrations and to infer the bulk flame temperature. These methods cannot be used to measure unstable combustion products and have poor spatial and temporal resolution. The intrusive nature of gas sampling may also disturb the flow structure within a combustor. Planar laser-induced fluorescence (PLIF) is an optical technique for the measurement of combustion species. In addition to its non-intrusive nature, PLIF offers these advantages over gas sampling: high spatial resolution, high temporal resolution, the ability to measure unstable species, and the potential to measure combustion temperature. This thesis considers PLIF for in-situ visualization of combustion species as a tool for the design and evaluation of gas turbine combustor subcomponents. This work constitutes the first application of PLIF to the severe environment found in liquid-fueled, aviation gas turbine combustors. Technical and applied challenges are discussed. PLIF of OH was used to observe the flame structure within the post flame zone of a flame tube combustor, and within the flame zone of a sector combustor, for a variety of fuel injector configurations. OH was selected for measurement because it is a major combustion intermediate, playing a key role in the chemistry of combustion, and because its presence within the flame zone can serve as a qualitative marker of flame temperature. All images were taken in the environment of actual engines during flight, using actual jet fuel. The results of the PLIF study led directly to the modification of a fuel injector.

Hicks, Yolanda Royce

Quantitative Measurements of Nitric Oxide Concentration in High-Pressure, Swirl-Stabilized Spray Flames

Lean direct-injection (LDI) spray flames offer the possibility of reducing NO(sub x) emissions from gas turbines by rapid mixing of the liquid fuel and air so as to drive the flame structure toward partially-premixed conditions. We consider the technical approaches required to utilize laser-induced fluorescence methods for quantitatively measuring NO concentrations in high-pressure LDI spray flames. In the progression from atmospheric to high-pressure measurements, the LIF method requires a shift from the saturated to the linear regime of fluorescence measurements. As such, we discuss quantitative, spatially resolved laser-saturated fluorescence (LSF), linear laser-induced fluorescence (LIF), and planar laser-induced fluorescence (PLIF) measurements of NO concentration in LDI spray flames. Spatially-resolved LIF measurements of NO concentration (ppm) are reported for preheated, LDI spray flames at pressures of two to five atmospheres. The spray is produced by a hollow-cone, pressure-atomized nozzle supplied with liquid heptane. NO is excited via the Q(sub 2)(26.5) transition of the gamma(0,0) band. Detection is performed in a two nanometer region centered on the gamma(0,1) band. A complete scheme is developed by which quantitative NO concentrations in high-pressure LDI spray flames can be measured by applying linear LIF. NO is doped into the reactants and convected through the flame with no apparent destruction, thus allowing a NO fluorescence calibration to be taken inside the flame environment. The in-situ calibration scheme is validated by comparisons to a reference flame. Quantitative NO profiles are presented and analyzed so as to better understand the operation of lean-direct injectors for gas turbine combustors. Moreover, parametric studies are provided for variations in pressure, air-preheat temperature, and equivalence ratio. Similar parametric studies are performed for lean, premixed-prevaporized flames to permit comparisons to those for LDI flames. Finally, PLIF is expanded to high pressure in an effort to quantify the detected fluorescence image for LDI flames. Success is achieved by correcting the PLIF calibration via a single-point LIF measurement. This procedure removes the influence of any preferential background that occurs in the PLIF detection window. In general, both the LIF and PLIF measurements verify that the LDI strategy could be used to reduce NO(sub x) emissions in future gas turbine combustors.

Cooper, Clayton S.

Comparison of MSL RCS Jet Computations With Flow Visualization and Velocimetry

Numerical predictions of the Mars Science Laboratory (MSL) reaction control system (RCS) jets interacting with a Mach 10 hypersonic flow are compared to experimental nitric oxide (NO) planar laser-induced fluorescence (PLIF) data. The steady Reynolds Averaged Navier Stokes (RANS) equations using the Baldwin-Barth one-equation turbulence model were solved using the OVERFLOW code. The experimental PLIF data used for comparison consists of qualitative two-dimensional visualization images, qualitative reconstructed three-dimensional flow structures, and quantitative two-dimensional distributions of streamwise velocity. Through modeling of the PLIF signal equation, computational flow images (CFI) were produced and directly compared to the qualitative PLIF data. Post processing of the experimental and simulation data enabled the jet trajectory to be extracted for a more quantitative comparison. The two-dimensional velocity fields were reconstructed through interpolation of a series of single-component velocity profiles. Each distribution of single-component velocity was obtained using molecular tagging velocimetry (MTV). After validating the numerical model, the numerical solution was further examined to gain insight into hypersonic jet-in-crossflow interaction. Future NO-PLIF experiments are proposed based on this analysis.

Johansen, Craig T.

Visualization of post-detonation fireball flowfields and comparison to CFD modeling

Visualization of flow structures within post-detonation fireballs has been performed for benchmark validation of numerical simulations. Custom pressed PETN explosives with a 12-mm diameter hemispherical form factor were used to produce a spherically symmetric post-detonation flow with low soot yield. Hydroxyl-radical planar laser induce fluorescence (OH-PLIF) was employed to visualize the structure ranging from approximately 10 μs to 35 μs after shock breakout from the explosive pellet. Fireball simulations were performed using the HyBurn Computational Fluid Dynamics (CFD) package. Experimental OH-PLIF results were compared to synthetic OH-PLIF from post-processing of CFD simulations. From the comparison of experimental and synthetic OH-PLIF images, CFD is shown to replicate much of the flow structure observed in the experiments, revealing potential differences in turbulent length scales and OH kinetics. Furthermore, results provide significant advancement in experimental resolution of these harsh turbulent combustion environments and validate physical models thereof.

Detonator

Flow Visualization for Plume-Surface Interaction at Martian-Relevant Lander Environments

This paper describes a jet impingement experiment performed in a large-scale vacuum chamber at Martian-relevant ambient pressure conditions, with the motivation of studying plume-surface interaction (PSI) caused by the exhaust plume of a lander interacting with the planetary surface. Flow visualization of an inert supersonic jet was performed using planar laser-induced fluorescence (PLIF), which is a molecular-based, two-dimensional measurement technique. Representative instantaneous and time-averaged visualizations of the impinging jet at two different nozzle flow conditions corresponding to the underexpanded and overexpanded jet regimes are presented for up to six different dimensionless altitudes h/De. The time-averaged measured spatial distribution of impingement pressures at these conditions is also reported. The PLIF visualizations appear to be critical towards explaining unexpected behavior in the impingement pressure, such as a higher impingement pressure for the underexpanded condition at h/De = 10, compared to a lower altitude of h/De = 8. This behavior can be attributed to differences in the stagnation shock structure observed in the PLIF images. The PLIF images also reveal significant flow separation at the nozzle exit for the overexpanded jet conditions. Further analysis of the test data as well as combined flow visualization and surface diagnostics for future ground tests will help inform engineering designs for landings on the Martian surface while mitigating PSI risks.

PLIF

Flow Visualization for Plume-Surface Interaction at Martian-Relevant Lander Environments

This paper describes a jet impingement experiment performed in a large-scale vacuum chamber at Martian-relevant ambient pressure conditions, with the motivation of studying plume-surface interaction (PSI) caused by the exhaust plume of a lander interacting with the planetary surface. Flow visualization of an inert supersonic jet was performed using planar laser-induced fluorescence (PLIF), which is a molecular-based, two-dimensional measurement technique. Representative instantaneous and time-averaged visualizations of the impinging jet at two different nozzle flow conditions corresponding to the underexpanded and overexpanded jet regimes are presented for up to six different dimensionless altitudes h/De. The time-averaged measured spatial distribution of impingement pressures at these conditions is also reported. The PLIF visualizations appear to be critical towards explaining unexpected behavior in the impingement pressure, such as a higher impingement pressure for the underexpanded condition at h/De = 10, compared to a lower altitude of h/De = 8. This behavior can be attributed to differences in the stagnation shock structure observed in the PLIF images. The PLIF images also reveal significant flow separation at the nozzle exit for the overexpanded jet conditions. Further analysis of the test data as well as combined flow visualization and surface diagnostics for future ground tests will help inform engineering designs for landings on the Martian surface while mitigating PSI risks.

PLIF

Instantaneous velocity field imaging instrument for supersonic reacting flows

The technical tasks conducted to develop and demonstrate a new gas velocity measurement technique for high enthalpy reacting flows is described. The technique is based on Doppler-shifted Planar Laser-induced Fluorescence (PLIF) imaging of the OH radical. The imaging approach permits, in principle, single-shot measurements of the 2-D distribution of a single velocity component in the measurement plane, and is thus a technique of choice for applications in high enthalpy transient flow facilities. In contrast to previous work in this area, the present program demonstrated an approach which modified the diagnostic technique to function under the constraints of practical flow conditions of engineering interest, rather than vice-versa. In order to accomplish the experimental demonstrations, the state-of-the-art in PLIF diagnostic techniques was advanced in several ways. Each of these tasks is described in detail and is intended to serve as a reference in supporting the transition of this new capability to the fielded PLIF instruments now installed at several national test facilities. Among the new results of general interest in LlF-based flow diagnostics, a detailed set of the first measurements of the collisional broadening and shifting behavior of OH (1,0) band transitions in H7-air combustion environments is included. Such measurements are critical in the design of a successful strategy for PLIF velocity imaging; they also relate to accurate concentration and temperature measurements, particularly in compressible flow regimes. Furthermore, the results shed new light on the fundamental relationship between broadening and energy transfer collisions in OH A(sup 2)Sigma(+)v(sup ') = 1. The first single-pulse, spectrally-resolved measurements of the output of common pulsed dye lasers were also produced during the course of this effort. As with the OH broadening measurements, these data are a significant aspect of a successful velocity imaging strategy, and also have potential implications for many other LIF measurement techniques. Our results indicated the need to modify the commercially available laser cavity in order to accommodate the constraints imposed by typical SCRAMJET combustion characteristics as well as to increase the instrument's velocity dynamic range to span an intra-image range in excess of 2 km/s. The various technical efforts were brought together in a series of experiments demonstrating the applicability of the technique in a high pressure, high temperature H2-air combustion system. The resultant images were compared with 2-D flow simulations in order to determine the accuracy of the instrument. Mean velocity imaging in flows with an axis of symmetry was demonstrated with an accuracy of +/- 50 m/s out of an intra-image dynamic range of 1600 m/s, including reversed flow. A more complex configuration amenable to single-shot imaging in flows without an axis of symmetry was also demonstrated. Limitations imposed by available equipment resulted in an accuracy of about +/- 200 m/s out of 1750 m/s in these demonstrations. Minor modifications to the present configuration were suggested to improve this performance. Each technical task is described in detail, along with significance of the results for the overall imaging velocimeter configuration. This report should allow the user community to integrate this new measurement capability in their existing instrumentation platforms.

Allen, M. G.

Visualization of a Capsule Entry Vehicle Reaction-Control System (RCS) Thruster

Planar laser-induced fluorescence (PLIF) was used to visualize the reaction control system (RCS) jet flow emanating from the aft-body of an Apollo-geometry capsule test article in the NASA Langley Research Center 31-Inch Mach 10 Air wind tunnel. The RCS jet was oriented normal to the aft surface of the model and had a nominal Mach number of 2.94. The composition of the jet gas by mass was 95% nitrogen (N2) and 5% nitric oxide (NO). The RCS jet flowrate varied between zero and 0.5 standard liters per minute and the angle of attack and tunnel stagnation pressure were also varied. PLIF was used to excite the NO molecules for flow visualization. These flow visualization images were processed to determine the trajectory and to quantify the flapping of the RCS jet. The spatial resolution of the jet trajectory measurement was about 1 mm and the single-shot precision of the measurement was estimated to be 0.02 mm in the far field of the jet plume. The jet flapping, measured by the standard deviation of the jet centerline position was as large as 0.9 mm, while the jet was 1.5-4 mm in diameter (full width at half maximum). Schlieren flow visualization images were obtained for comparison with the PLIF. Surface pressures were also measured and presented. Virtual Diagnostics Interface (VIDI) technology developed at NASA Langley was used to superimpose and visualize the data sets. The measurements demonstrate some of the capabilities of the PLIF method while providing a test case for computational fluid dynamics (CFD) validation.

Danehy, P. M.

Orbiter BLT Flight Experiment Wind Tunnel Simulations: Nearfield Flowfield Imaging and Surface Thermography

This paper reports a series of wind tunnel tests simulating the near-field behavior of the Space Shuttle Orbiter Boundary Layer Transition Detailed Test Objective (BLT DTO) flight experiment. Hypersonic flow over a flat plate with an attached BLT DTO-shaped trip was tested in a Mach 10 wind tunnel. The sharp-leading-edge flat plate was oriented at an angle of 20 degrees with respect to the freestream flow, resulting in post-shock edge Mach number of approximately 4. The flowfield was visualized using nitric oxide (NO) planar laser-induced fluorescence (PLIF). Flow visualizations were performed at 10 Hz using a wide-field of view and high-resolution NO PLIF system. A lower spatial resolution and smaller field of view NO PLIF system visualized the flow at 500 kHz, which was fast enough to resolve unsteady flow features. At the lowest Reynolds number studied, the flow was observed to be laminar and mostly steady. At the highest Reynolds number, flow visualizations showed streak instabilities generated immediately downstream of the trip. These instabilities transitioned to unsteady periodic and spatially irregular structures downstream. Quantitative surface heating imagery was obtained using the Temperature Sensitive Paint (TSP) technique. Comparisons between the PLIF flow visualizations and TSP heating measurements show a strong correlation between flow patterns and surface heating trends.

Danehy, Paul M.

Quantitative Analysis of Planar Laser-Induced Fluorescence Measurements in a Hypersonic Boundary Layer

Several quantitative measurements extracted from nitric oxide (NO) planar laser-induced fluorescence (PLIF) data obtained in a hypersonic boundary layer are reported: (a) off-body NO mole fraction; (b) surface heat flux; and (c) near-wall static temperature. The experimental data was obtained at NASA Langley Research Center’s 31 in. Mach 10 air tunnel. NO was seeded into the flow through a spanwise slot on the surface of the 10 degree half-angle wedge model. An ultraviolet planar laser sheet was positioned perpendicular to the wedge surface, downstream of the seeding slot, to excite six fluorescence transitions. A method for extracting the relative NO mole fraction, based on spatial variations of the J”= 0.5 PLIF signal, is presented. Combined with the principle of mass conservation, the absolute NO mole fraction is determined. These measurements were used to assess CFD diffusion modelling, correct previously reported PLIF thermometry results, and develop methods for NO-PLIF heat transfer measurements.

McDougall, Connor C.

Simultaneous 100-kHz Acetone Planar Laser-Induced Fluorescence and OH* Chemiluminescence in a Linear Non-Premixed Detonation Channel

Reactant mixing and combustion are investigated in an optically accessible, self-excited linear detonation combustor. The mixing field is captured using 100 kHz planar laser-induced fluorescence (PLIF) imaging of acetone as a tracer in the fuel supply, while 100 kHz chemiluminescence imaging of excited-state hydroxyl (OH*) radicals simultaneously resolves the evolution of the detonation wave. Time sequences are acquired over multiple detonation cycles in each test, with acetone-PLIF images collected along multiple orthogonal planes to reveal the complex three-dimensional topography of the fuel distribution. The instantaneous and phase averaged acetone-PLIF images enable measurement of key fuel injection characteristics, such as the injector recovery time, fuel jet velocity, and refill height for a range of operating conditions. Instantaneous and phase-averaged measurements of acetone-PLIF with the time-coincident OH* chemiluminescence images also reveal a number key features, such as fuel stratification and weak detonation in the injector near field, incomplete combustion and deflagration behind the detonation wave, vitiation and deflagration of reactants ahead of the detonation wave, and fuel and oxidizer recovery time mismatch leading to combustion inefficiency. These measurements significantly enhance the ability to obtain detailed information on the intracycle and intercycle spatiotemporal evolution of the reactant refill process and its coupled effects on the detonation wave structure and propagation.

Propulsion

Towards Simultaneous Multi-Parameter Measurements Using Burst-Mode Frequency-Scanning Planar Laser-Induced Fluorescence

While planar laser-induced fluorescence (PLIF) can provide valuable flow visualization, there are many challenges in extracting quantitative measurements from the fluorescence intensity. To overcome the multi-parameter dependence of the signal intensity, frequency scanning planar laser-induced fluorescence (FS-PLIF) provides the potential for 2D temperature, pressure, and velocity measurements by spectrally resolving the excitation spectrum of one or more fluorescence transitions to extract the Doppler shift, Doppler- and collisional-broadening of absorption lines, and the relative signal intensities of multiple transitions. This work aims to characterize a burst-mode FS-PLIF system consisting of a Spectral Energies, LLC burst-mode laser coupled with a Spectral Energies, LLC optical parametric oscillator using nitric oxide (NO) static pressure cell measurements. The effect of the OPO cavity on intensity fluctuations during frequency-scanning is investigated. A NO PLIF model is implemented to investigate the feasibility of property measurements using single- and two-NO-line scans.

burst-mode laser

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration With Methane–Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible premixing tube allowing the optical diagnostics. The testing was conducted for varied premixer velocities (V) and equivalence ratio (ϕ) for 90–100% (H 2 , by mole) H 2 /CH 4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior, where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A large eddy simulation (LES) with detailed chemistry combustion modeling approach was implemented along with an OH* submechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

chemiluminescence diagnostic