Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA GENERATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Space Rated High Voltage Plasma Generating Supply

The use of plasma for in-situ resource utilization (ISRU) applications (such as water treatment, acid production, plant seed activation, biofilm sanitization, or waste gasification) is an active area of research at the KSC Applied Chemistry Lab (ACL). The generation of plasma for experimentation has thus far been done with lab-rated power supplies which are unsuitable for space applications, and no suitable supply is readily available for purchase. This project tackled the development of a low TRL prototype 500 W power supply intended for generating plasma in space. The design was based on similar power electronic circuits used for electric propulsion systems and was adapted for use in ISRU applications. This technology will enable KSC’s plasma-based ISRU related technologies to be demonstrated in the space environment.

Nathaniel Cain↗

A spectrometer on chemical vapour deposition-diamond basis for the measurement of the charge-state distribution of heavy ions in a laser-generated plasma

This article reports on the development and the first applications of a new spectrometer which enables the precise and time-resolved measurement of both the energy loss and the charge-state distribution of ion beams with 10 < Z < 30 at energies of 4-8 MeV/u after their interaction with a laser-generated plasma. The spectrometer is based on five 20 Multiplication-Sign 7 mm{sup 2} large and 20 {mu}m thick polycrystalline diamond samples produced via the Chemical Vapour Deposition (CVD) process and was designed with the help of ion-optical simulations. First experiments with the spectrometer were successfully carried out at GSI using {sup 48}Ca ions at an energy of 4.8 MeV/u interacting with a carbon plasma generated by the laser irradiation of a thin foil target. Owing to the high rate capability and the short response time of the spectrometer, pulsed ion beams with 10{sup 3}-10{sup 4} ions per bunch at a bunch frequency of 108 MHz could be detected. The temporal evolution of the five main charge states of the calcium ion beams as well as the corresponding energy loss values could be measured simultaneously. Due to the outstanding properties of diamond as a particle detector, a beam energy resolution ({Delta}E/E) Almost-Equal-To 0.1% could be reached using the presented experimental method, while a precision of 10% in the energy loss and charge-state distribution data was obtained.

36 MATERIALS SCIENCE↗

Effect of thermionic cathode heating current self-magnetic field on gaseous plasma generator characteristics

The performance capabilities of the PINK, a plasma generator with a thermionic cathode mounted in the cavity of a hollow cathode, depending for its operation on a non-self-sustained low-pressure gas discharge have been investigated. It has been shown that when a single-filament tungsten cathode 2 mm in diameter is used and the peak filament current is equal to or higher than 100 A, the self-magnetic field of the filament current significantly affects the discharge current and voltage waveforms. This effect is due to changes in the time and space distributions of the emission current density from the hot cathode. When the electron mean free path is close to the characteristic dimensions of the thermionic cathode, the synthesized plasma density distribution is nonuniform and the cathode is etched nonuniformly. The cathode lifetime in this case is 8–12 h. Using a cathode consisting of several parallel-connected tungsten filaments ∼0.8 mm in diameter moderates the effect of the self-magnetic field of the filament current and nearly doubles the cathode lifetime. The use of this type of cathode together with a discharge igniting electrode reduces the minimum operating pressure in the plasma generator to about one third of that required for the generator operation with a single-filament cathode (to 0.04 Pa)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A research program in magnetogasdynamics utilizing hypervelocity coaxial plasma generators

A broadly-gauged research program in magnetogasdynamics utilizing hypervelocity coaxial plasma generators is presented. A complete hypervelocity coaxial plasma generator facility was assembled and tested. Significant progress was made in the direction of understanding the important processes in the interaction of hypervelocity MGD flow with transverse applied fields. It is now proposed to utilize the accumulated experimental capability and theoretical analysis in application to the analysis and design parameterization of pulsed magnetogasdynamic direct energy convertor configurations.

Spight, C.↗

A study of velocity, temperature, and density in the plasma generated by laser-induced breakdowns

The paper presents velocity measurements of shock-induced flow field, leading to vortex generation and plasma deformation in air. Femtosecond-laser electronic excitation tagging (FLEET) velocimetry was performed at the times Δt = 3, 20, 50, and 100 µs post laser-induced breakdown. Emissions over Δt = 3–10 µs showed the propagations of the initially elliptic shock, transitioning into a spherical front. The shock emanated along the laser axis causes the flow outward, and then the pressure gradient generated by the rarefaction wave drives the inward flow at later moments, with the velocity magnitude approaching a steady-state value of 40 m s -1 . Temporal velocity evolution was compared with non-self-similar solutions behind the propagating shock, which are sensitive to the size of the energy deposition, and the use of the measured initial plasma diameter reproduced the experiment. There establishes a region of uniform velocity around 35 m s -1 in the air-flow running through the plasma, which triggers the roll-up of the plasma surface by a large-scale vortex, providing the detail of flow field evolution from the shock propagation to the plasma deformation. A collective Thomson scattering and hybrid fs/ps pure rotational coherent anti-Stokes Raman scattering (CARS) were also performed to gain insight into the high-temperature plasma. An effective electron–ion recombination rate of 2 x 10 -12 cm 3 s -1 was measured at Δt = 0.5–10 µs, during a dynamic plasma expansion and compression. When the shock resides close to the plasma at Δt = 0.5–1 µs, the temperature distributions were found to follow the similarity law.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation on plasma generated during hypervelocity impact at different impact velocities and angles

A 3D Smoothed Particle Hydrodynamics code was developed to investigate plasma generation by considering a chemical reaction process in hypervelocity impacts of an aluminum projectile on an aluminum target. The chemical reaction process was described by the reaction rate based on the Arrhenius equation and used to calculate the plasma generation during the impact simulation. The predicted result was verified by empirical formulas and a new empirical formula was proposed based on the comparisons and analyses. The influence of the impact angle was discussed for different impact velocities. Then, the application of both the new and original empirical formulas for protection design from plasma generated by hypervelocity impact was discussed, which demonstrated that the code and model were useful in the prediction of hypervelocity impacts on spacecraft.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling magnetic confinement of laser-generated plasma in cylindrical geometry leading to disk-shaped structures

Radiation-magnetohydrodynamic simulations were able to reproduce features of the plasma structures observed in recent experiments1, where a laser was used to ablate plasma in a 3 MG magnetic field. The laser ablates the plasma, and localized structures are formed due to the inhibition of heat flow by the magnetic field. The large magnetic pressures cause the plasma to pinch. In an azimuthal fi eld, a disc-shaped plasma is generated. According to simulations, the disc has electron densities that are underdense to the laser, ranging from 10 18 to 10 19 cm -3 , and electron temperatures in the 300 to 1000 eV range during its evolution, similar to experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On uniform plasma generation for the large area plasma processing in intermediate pressures

Radial plasma discharge characteristics in the range of 450 mm were studied in a dual inductively coupled plasma (ICP) source, which consisted of a helical ICP and the side type ferrite ICPs. Since the energy relaxation length is shorter than the distance between each of the ferrite ICPs in an intermediate pressure (600 mTorr), local difference in the plasma ignition along the antenna position were observed. In addition, large voltage drop in the discharge of the ferrite ICPs causes an increase in the displacement current to the plasma, and separate discharge mode (E and H mode) according to the antenna position was observed. This results in non-uniform plasma distribution. For the improvement in the discharge of the ferrite ICPs, a capacitor which is placed between the ends of antenna and the ground is adjusted to minimize the displacement current to the plasma. As a result, coincident transitions from E to H mode were observed along the antenna position, and radially concave density profile (edge focused) was measured. For the uniform density distribution, a helical ICP, which located at the center of the discharge chamber, was simultaneously discharged with the ferrite ICPs. Due to the plasma potential variation through the simultaneous discharge of helical ICP and ferrite ICPs, uniform radial distribution in both plasma density and electron temperature are achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A study of plasma expansion phenomena in laboratory generated plasma wakes - Preliminary results

The plasma expansion into the wake of a large rectangular plate immersed in a single-ion, collisionless, streaming plasma has been investigated in the laboratory. Several characteristics of the process involved in 'plasma expansion into vacuum' that have been predicted theoretically were observed, including the creation and motion of a rarefaction wave disturbance; the creation and motion of an expansion front; and the acceleration of ions into the wake at speeds above the ion-acoustic speed. The expansion was limited to early times; i.e., a few ion plasma periods, by the combination of plasma drift speed and vacuum chamber size. This prevented detailed comparison with self-similar theory, but results are in good agreement with numerical simulations and other laboratory experiments for the early time expansion. The conclusion is that the plasma expansion process is the dominant wake filling mechanism in the near wake of a body, whose potential is approximately the plasma space potential.

Wright, K. H., Jr.↗

Divertor conditions relevant for fusion reactors achieved with linear plasma generator

Intense magnetized hydrogen and deuterium plasmas have been produced with electron densities up to 3.6 Multiplication-Sign 10{sup 20} m{sup -3} and electron temperatures up to 3.7 eV with a linear plasma generator. Exposure of a W target has led to average heat and particle flux densities well in excess of 4 MW m{sup -2} and 10{sup 24} m{sup -2} s{sup -1}, respectively. We have shown that the plasma surface interactions are dominated by the incoming ions. The achieved conditions correspond very well to the projected conditions at the divertor strike zones of fusion reactors such as ITER. In addition, the machine has an unprecedented high gas efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Thomson scattering system for high-flux linear plasma generator

An advanced Thomson scattering system has been built for a linear plasma generator for plasma surface interaction studies. The Thomson scattering system is based on a Nd:YAG laser operating at the second harmonic and a detection branch featuring a high etendue (f /3) transmission grating spectrometer equipped with an intensified charged coupled device camera. The system is able to measure electron density (n{sub e}) and temperature (T{sub e}) profiles close to the output of the plasma source and, at a distance of 1.25 m, just in front of a target. The detection system enables to measure 50 spatial channels of about 2 mm each, along a laser chord of 95 mm. By summing a total of 30 laser pulses (0.6 J, 10 Hz), an observational error of 3% in n{sub e} and 6% in T{sub e} (at n{sub e}= 9.4 Multiplication-Sign 10{sup 18} m{sup -3}) can be obtained. Single pulse Thomson scattering measurements can be performed with the same accuracy for n{sub e} > 2.8 Multiplication-Sign 10{sup 20} m{sup -3}. The minimum measurable density and temperature are n{sub e} < 1 Multiplication-Sign 10{sup 17} m{sup -3} and T{sub e} < 0.07 eV, respectively. In addition, using the Rayleigh peak, superimposed on the Thomson scattered spectrum, the neutral density (n{sub 0}) of the plasma can be measured with an accuracy of 25% (at n{sub 0}= 1 Multiplication-Sign 10{sup 20} m{sup -3}). In this report, the performance of the Thomson scattering system will be shown along with unprecedented accurate Thomson-Rayleigh scattering measurements on a low-temperature argon plasma expansion into a low-pressure background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency up-conversion of a high-power microwave pulse propagating in a self-generated plasma

In the study of the propagation of a high-power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. A frequency autoconversion process that can lead to reflectionless propagation of powerful electromagnetic pulses in self-generated plasmas is studied. The theory shows that, under the proper condition, the carrier frequency omega of the pulse shifts upward during the growth of local plasma frequency omega(pe). Thus, the self-generated plasma remains underdense to the pulse. A chamber experiment to demonstrate the frequency autoconversion during the pulse propagation through the self-generated plasma is conducted. The detected frequency shift is compared with the theoretical result calculated by using the measured electron density distribution along the propagation path of the pulse. Good agreement is obtained.

Kuo, S. P.↗

Self-consistent modeling of radio-frequency plasma generation in stellarators

A self-consistent model of radio-frequency (RF) plasma generation in stellarators in the ion cyclotron frequency range is described. The model includes equations for the particle and energy balance and boundary conditions for Maxwell’s equations. The equation of charged particle balance takes into account the influx of particles due to ionization and their loss via diffusion and convection. The equation of electron energy balance takes into account the RF heating power source, as well as energy losses due to the excitation and electron-impact ionization of gas atoms, energy exchange via Coulomb collisions, and plasma heat conduction. The deposited RF power is calculated by solving the boundary problem for Maxwell’s equations. When describing the dissipation of the energy of the RF field, collisional absorption and Landau damping are taken into account. At each time step, Maxwell’s equations are solved for the current profiles of the plasma density and plasma temperature. The calculations are performed for a cylindrical plasma. The plasma is assumed to be axisymmetric and homogeneous along the plasma column. The system of balance equations is solved using the Crank-Nicholson scheme. Maxwell’s equations are solved in a one-dimensional approximation by using the Fourier transformation along the azimuthal and longitudinal coordinates. Results of simulations of RF plasma generation in the Uragan-2M stellarator by using a frame antenna operating at frequencies lower than the ion cyclotron frequency are presented. The calculations show that the slow wave generated by the antenna is efficiently absorbed at the periphery of the plasma column, due to which only a small fraction of the input power reaches the confinement region. As a result, the temperature on the axis of the plasma column remains low, whereas at the periphery it is substantially higher. This leads to strong absorption of the RF field at the periphery via the Landau mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Slot-Antenna/Permanent-Magnet Device for Generating Plasma

A device that includes a rectangular-waveguide/slot-antenna structure and permanent magnets has been devised as a means of generating a substantially uniform plasma over a relatively large area, using relatively low input power and a low gas flow rate. The device utilizes electron cyclotron resonance (ECR) excited by microwave power to efficiently generate plasma in a manner that is completely electrodeless in the sense that, in principle, there is no electrical contact between the plasma and the antenna. Plasmas generated by devices like this one are suitable for use as sources of ions and/or electrons for diverse material-processing applications (e.g., etching or deposition) and for ion thrusters. The absence of plasma/electrode contact essentially prevents plasma-induced erosion of the antenna, thereby also helping to minimize contamination of the plasma and of objects exposed to the plasma. Consequently, the operational lifetime of the rectangular-waveguide/ slot-antenna structure is long and the lifetime of the plasma source is limited by the lifetime of the associated charged-particle-extraction grid (if used) or the lifetime of the microwave power source. The device includes a series of matched radiating slot pairs that are distributed along the length of a plasma-source discharge chamber (see figure). This arrangement enables the production of plasma in a distributed fashion, thereby giving rise to a uniform plasma profile. A uniform plasma profile is necessary for uniformity in any electron- or ion-extraction electrostatic optics. The slotted configuration of the waveguide/ antenna structure makes the device scalable to larger areas and higher powers. All that is needed for scaling up is the attachment of additional matched radiating slots along the length of the discharge chamber. If it is desired to make the power per slot remain constant in scaling up, then the input microwave power must be increased accordingly. Unlike in prior ECR microwave plasma-generating devices, there is no need for an insulating window on the antenna. Such windows are sources of contamination and gradually become ineffective as they become coated with erosion products over time. These characteristics relegate prior ECR microwave plasma-generating devices to non-ion beam, non-deposition plasma applications. In contrast, the lack of need for an insulating window in the present device makes it possible to use the device in both ion-beam (including deposition) and electron-beam applications. The device is designed so that ECR takes place above each slot and the gradient of the magnetic field at each slot is enough to prevent backflow of plasma.

Foster, John E.↗