Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTOMULTIPLIERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multi-Anode Square Microchannel Plate Photomultiplier Tube

Photek has developed a high performance 4096-anode photomultiplier tube using microchannel plates as the gain medium. Additionally, the detector has been designed in a square format to maximise the active area and allow for easy tiling to cover large areas using multiple units. This paper analyses the detector performance in terms of gain and photocathode uniformity, single photon timing accuracy, count rate capability, cross talk and magnetic field susceptibility.

47 OTHER INSTRUMENTATION↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality assurance test of silicon photomultipliers and electronic boards for STAR event plane detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver (RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. As a result, the QA test results are presented along with the discussions.

EPD↗

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel silicon photomultiplier readout architecture for low-light applications

In this article we describe the photon detection readout electronics for the nEDM@SNS experiment. The chosen "photon counting" architecture, which utilizes high-efficiency silicon photomultipliers (SiPMs) and is appropriate for low-light applications, allows the use of a relatively high SiPM operating voltage. This maximizes photon detection efficiency and minimizes gain/efficiency voltage-dependence while eliminating direct optical cross-talk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acceptance tests of Hamamatsu R7081 photomultiplier tubes

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around 100 PMTs to measure the response of different media suitable for rare event searches. A subset of low-radioactivity 10-inch Hamamatsu R7081 PMTs were tested, characterised, and compared to manufacture certification. This manuscript describes the laboratory tests and analysis of gain, peak-to-valley ratio and dark rate of the PMTs to give an understanding of the charge response, signal-to-noise ratio and dark noise background as an acceptance test of the suitability of these PMTs for water-based detectors. Following the evaluation of these tests, the PMT performance agreed with the manufacturer specifications. These results are imperative for modeling the PMT response in detector simulations and providing confidence in the performance of the devices once installed in the detector underground.

neutrino detectors↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Enhanced Surface Passivation by Atomic Layer Deposited Al 2 O 3 for Ultraviolet Sensitive Silicon Photomultipliers

Here, we describe a superior passivation of p-type (p + ) Si surface by Al 2 O 3 thin film that is synthesized by plasma-assisted atomic layer deposition for ultraviolet sensitive silicon photomultipliers (SiPM), compared to conventional SiO 2 and SiN x passivation schemes. The superiority of Al 2 O 3 passivation is due to not only a sufficiently low interface defect density but also a high density of built-in negative charges. A 7 nm thin Al 2 O 3 film can yield an emitter saturation current density of ~8 fA/cm 2 on high sheet resistance p + layer, compared to ~60 and ~1480 fA/cm 2 for thermal SiO 2 and SiN x passivation. This superior surface passivation allows the photon-generated carriers to have higher probabilities to reach the high-field region to trigger an avalanche event. In addition, Al 2 O 3 thin film provides very low values of effective surface recombination velocity on low resistivity n-type and p-type Si surfaces, which can lead to well-passivated surface features on guard ring and trench isolation regions of SiPM. These demonstrate the potential of Al 2 O 3 thin film passivation to improve quantum efficiency and thus photo-detection efficiency of ultraviolet sensitive SiPM with p + /n - /n/n + structure.

36 MATERIALS SCIENCE↗

Performance of CsI:Tl Cyrstal with a Spectrum Matching Photomultiplier Tube

This report documents an effort to improve the energy resolution for a thallium doped cesium iodide (CsI:T1) scintillator paired with a spectrum matching photomultiplier tube (PMT). A comparison of the differences in the pulse height spectra from thallium doped (CsI:T1) and sodium doped (CsI:Na) single crystals with PMTs of different spectrum responses was performed. Results show that energy resolution of the detector only improves 0.5% at room temperature when these scintillators are coupled with a spectrum matching PMT. Based on a spectrum matching PMT, the best results for energy resolution are 7.39% and 7.88% for CsI:T1 and CsI:Na scintillators, respectively. The improvement is primarily attributed to the increase of photon statistics from the increase of photons (N) being detected in the spectrum matching PMT. Other factors, such as optical quantum yield and non-proportionality of the CsI:T1 and CsI:Na crystals, that can affect the energy resolution were also studied and reported. The results indicate that although the use of a spectrum matching PMT enhances the photon statistics, it also exacerbates the nonproportionality response. Consequently, a promised improvement on energy resolution due solely to photon statistics was not fully realized.

36 MATERIALS SCIENCE↗

Modification of a Silicon Photomultiplier for Reduced High Temperature Dark Count Rate

In this work we present a novel method for improving the high-temperature performance of silicon photomultipliers (SiPMs) via focused ion beam (FIB) modification of individual microcells. The literature suggests that most of the dark count rate (DCR) in a SiPM is contributed by a small percentage (<5%) of microcells. By using a FIB to electrically deactivate this relatively small number of microcells, we believe we can greatly reduce the overall DCR of the SiPM at the expense of a small reduction in overall photodetection efficiency, thereby improving its high temperature performance. In this report we describe our methods for characterizing the SiPM to determine which individual microcells contribute the most to the DCR, preparing the SiPM for FIB, and modifying the SiPM using the FIB to deactivate the identified microcells.

42 ENGINEERING↗

Beam Loss Assessment Through Use of Photomultiplier Tubes

The first machine in the Fermilab Accelerator chain, the Linac, delivers a 400 MeV proton beam. The first portion of the Fermilab Linac, the Drift Tube Linac, lacks the degree of instrumentation necessary for beam tuning. To compensate for this, photomultiplier tube (PMT s) based loss monitors were installed on either side of the first two drift tube tanks, but are not yet operational. One of the main goals in this is to make PMT's operational beam loss monitors for tuning. Noise reduction and peak finding on the PMT data is a requirement for this. A method for noise reduction and peak finding has been developed and implemented to produce a consistent and stable output. Future work includes integration with ACNET to automate input and output of data for analysis of beam loss.

Waggoner, Alexander↗

Digital Silicon Photomultiplier Chip Testing

Silicon Photomultipliers (SiPMs) are highly sensitive photodetectors. Traditional analog SiPMs require complex external readout electronics. Digital SiPMs (dSiPMs) include digital readout circuitry directly on-chip, offering superior timing resolution, reduced power consumption and compact size, pixel-level masking for active noise reduction. The primary objectives of this study are to, verify digital logic integrity of the shift registers used for controlling the pixel masking circuit, and determine the dark count rate of individual pixels as a function of bias voltage and clock frequency. I observe and explain behavior of the shift register and counting circuit.

Graham, Bennett [U. Chicago (main)]↗

Characterization of Digital Silicon Photomultipliers

Digital Silicon photomultipliers (Digital SiPMs) have become an increasingly viable option for single-photon detection due to their compact size and precise timing and resolution. The following work characterizes the noise performance of a diSiPM designed and tested in-house at Fermilab. The SiPM consists of a 26x32 array of single-photon avalanche diode (SPAD) cells. Through the implementation of a shift register masking circuit, individual SPAD cells can be enabled and disabled at will, allowing for precise detection measurements of single columns (accumulator channels) and cells. The provided circuit design operates on voltage clock pulses and collects data on clock edges allowing for precise tuning of the data collection process by varying the clock frequency, pulse width, and integration period.

Shoemaker, Oliver [U. Chicago (main)]↗