Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Recanalization of Acute and Subacute Venous and Synthetic Bypass-Graft Occlusions With a Mechanical Rotational Catheter

PurposePercutaneous mechanical thrombectomy (PMT) is now established as an alternative treatment of acute arterial occlusions in addition to fibrinolysis and surgical thrombectomy. The objective of this retrospective study was the investigation of a rotational atherothrombectomy catheter in terms of safety and efficacy in the treatment of acute and subacute femoropopliteal bypass occlusions.Materials and MethodsForty-two patients (average age 65.8 {+-} 9.1 years) with acute (<14 days [n = 31]) and subacute (14-42 days [n = 11]) femoropopliteal bypass occlusions were treated consecutively with a rotational debulking and removal catheter (Straub Rotarex). The average occlusion length was 28.4 {+-} 2.9 (24-34) cm. Thirty-four (81 %) patients underwent venous bypass, and 8 (19 %) patients underwent polytetrafluoroethylene bypass.ResultsThe technical success rate was 97.6 % (41 of 42). In 1 patient, blood flow could not be restored despite the use of the atherothrombectomy system. The average catheter intervention time was 6.9 {+-} 2.1 (4-9) min. Ankle-brachial index increased from 0.39 {+-} 0.13 to 0.83 {+-} 0.11 at discharge and to 0.82 {+-} 0.17 after 1 month (p < 0.05). There were a total of 2 (4.8 %) peri-interventional complications: One patient developed a distal embolism, which was successfully treated with local lysis, and another patient had a small perforation at the distal anastomosis, which was successfully treated with a stent.ConclusionPMT with the Rotarex atherothrombectomy catheter represents a safe and effective option in the treatment of acute and subacute femoropopliteal bypass occlusions because it can quickly restore blood flow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent

PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize the tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Anatomical, Procedural, and Operator Skill Factors on the Success and Duration of Fluoroscopy-Guided Transjugular Intrahepatic Portosystemic Shunt

PurposeTo assess the impact of anatomical, procedural, and operator skill factors on the success and duration of fluoroscopy-guided transjugular intrahepatic portoystemic shunt following standard operating procedure (SOP).Material and MethodsDuring a 32-month period, 102 patients underwent transjugular intrahepatic portosystemic shunt creation (TIPS) by two interventional radiologists (IR) following our institutional SOP based on fluoroscopy guidance. Both demographic and procedural data were assessed. The duration of the intervention (D{sub Int}) and of the portal vein puncture (D{sub Punct}) was analyzed depending on the skill level of the IR as well as the anatomic or procedural factors.ResultsIn 99 of the 102 patients, successful TIPS without peri-procedural complications was performed. The mean D{sub Int} (IR1: 77 min; IR2: 51 min, P < 0.005) and the mean D{sub Punct} (IR1: 19 min; IR2: 13 min, P < 0.005) were significantly higher in TIPS performed by IR1 (with 2 years of clinical experience performing TIPS, n = 38) than by IR2 (>10 years of clinical experience performing TIPS, n = 61), (P < 0.005 both, Mann–Whitney U test). D{sub Int} showed a higher correlation with D{sub Punct} for IR2 (R{sup 2} = 0.63) than for IR1 (R{sup 2} = 0.13). There was no significant difference in the D{sub Punct} for both IRs with regard to the success of the wedged portography (P = 0.90), diameter of the portal vein (P = 0.60), central right portal vein length (P = 0.49), or liver function (MELD-Score before the TIPS procedure; P = 0.14).ConclusionTIPS following SOP is safe, fast, and reliable. The only significant factor for shorter D{sub Punct} and D{sub Int} was the clinical experience of the IR. Anatomic variability, successful portography, or liver function did not alter the duration or technical success of TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Value of Rotational Venography Versus Anterior–Posterior Venography in 100 Consecutive IVC Filter Retrievals

PurposeAccurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior–posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.Materials and MethodsThe rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tip embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.ResultsUsing operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59 %). AP venography was used to correctly identify 31 tip-embedded filters (53 % sensitivity) with two false positives (95 % specificity) for an accuracy of 70 %. Rotational venography was used to correctly identify 58 tip-embedded filters (98 % sensitivity) with one false positive (98 % specificity) for an accuracy of 98 %. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.ConclusionRotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Features of Radiofrequency Ablation with Heat-Deployed Liposomal Doxorubicin in Hepatic Tumors

IntroductionThe imaging features of unresectable hepatic malignancies in patients who underwent radiofrequency ablation (RFA) in combination with lyso-thermosensitive liposomal doxorubicin (LTLD) were determined.Materials and MethodsA phase I dose escalation study combining RFA with LTLD was performed with peri- and post- procedural CT and MRI. Imaging features were analyzed and measured in terms of ablative zone size and surrounding penumbra size. The dynamic imaging appearance was described qualitatively immediately following the procedure and at 1-month follow-up. The control group receiving liver RFA without LTLD was compared to the study group in terms of imaging features and post-ablative zone size dynamics at follow-up.ResultsPost-treatment scans of hepatic lesions treated with RFA and LTLD have distinctive imaging characteristics when compared to those treated with RFA alone. The addition of LTLD resulted in a regular or smooth enhancing rim on T1W MRI which often correlated with increased attenuation on CT. The LTLD-treated ablation zones were stable or enlarged at follow-up four weeks later in 69 % of study subjects as opposed to conventional RFA where the ablation zone underwent involution compared to imaging acquired immediately after the procedure.ConclusionThe imaging features following RFA with LTLD were different from those after standard RFA and can mimic residual or recurrent tumor. Knowledge of the subtle findings between the two groups can help avoid misinterpretation and proper identification of treatment failure in this setting. Increased size of the LTLD-treated ablation zone after RFA suggests the ongoing drug-induced biological effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Stenting for Portal Biliopathy with Jaundice

Portal biliopathy refers to obstruction of the bile duct by dilated peri- or para-ductal collateral channels following the main portal vein occlusion from various causes. Surgical shunt operation or endoscopic treatment has been reported. Herein, we report a case of portal biliopathy that was successfully treated by interventional portal vein recanalization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cryoablation of Hepatocellular Carcinoma with High-Risk for Percutaneous Ablation: Safety and Efficacy

PurposeThe aim of this study was to evaluate the safety and effectiveness of cryoablation in the treatment of subcapsular hepatocellular carcinoma (HCC) adjacent to various organs.Materials and MethodsTwenty-eight patients with subcapsular HCC were treated with cryoablation in our institution. The degree of peri-procedural pain was measured using the visual analog scale (VAS). Technical success, local tumor progression, and overall disease progression rates were calculated. Procedure-related complications were identified by reviewing electronic medical records. Biochemical data, including serum aspartate aminotransferase (AST), alanine aminotransferase (ALT), and total bilirubin levels before and after the procedure were collected.ResultsSubcapsular HCC tumors were located near the gallbladder, colon, stomach, kidney, diaphragm, or abdominal wall. The technical success rate of cryoablation was 96.4 % (27/28). Local recurrence- and progression-free survival rates were 96 and 84 % at 6 months, and 82 and 43 % at 1 year, respectively. All patients survived during the follow-up period. The VAS pain score ranged from 0 to 3 (mean, 1.57). A major complication occurred in one patient (3.6 %) and minor complications occurred at a rate of 17.9 %. Transient elevations of serum AST, ALT, and bilirubin levels were observed.ConclusionCryoablation is a safe and an effective procedure for the treatment of subcapsular HCC adjacent to various major organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minilaparotomy-Assisted Transmesenteric-Transjugular Intrahepatic Portosystemic Shunt: Comparison with Conventional Transjugular Approach

PurposeThis study was performed to compare the intrahepatic shunt function outcome and procedural complications of minilaparotomy-assisted transmesenteric (MAT)-transjugular intrahepatic portosystemic shunt (TIPS) placement with the conventional transjugular method.MethodsThis is a retrospective review of all patients who had a MAT or conventional TIPS procedure over a 6-year period at our institute. The primary patency rate, fluoroscopy time, technical success, major procedure-related complications, and mortality data were compared between two treatment groups.ResultsWe included 49 patients with MAT-TIPS, and 63 with conventional TIPS, with an average follow-up of 21.43 months. The primary patency rates at 6 and 12 months were 82.9 and 66.7 % in the conventional TIPS group, and 81.0 and 76.5 % in the MAT-TIPS group (p = 1.000, and 0.529), respectively. There was no significant difference in technical success rate, post-procedure portosystemic pressure gradient, fluoroscopy time, and peri-procedural mortality rate between treatment groups. Major procedural-related complications were seen more frequently among MAT-TIPS patients (p = 0.012). In the MAT-TIPS group, 5 (10.2 %) patients developed post-procedure minilaparotomy, wound-related complications, and 5 (10.2 %) developed bacterial peritonitis; whereas, none of patients with conventional TIPS had either of these complications (p = 0.014).ConclusionWhile both MAT-TIPS and conventional TIPS had similar shunt primary patency rate and technical success rate, the MAT approach was associated with a significantly higher rate of minilaparotomy-related wound complications or infectious complications. These complications maybe prevented by a change in post-procedure monitoring and therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

BackgroundIntra-arterial brachytherapy with yttrium-90 ({sup 90}Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of {sup 90}Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with {sup 90}Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from {sup 90}Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with {sup 90}Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the {sup 90}Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10{sup 6}) of bland microspheres.ConclusionThis study showed that radioembolization with {sup 90}Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of {sup 90}Y resin microspheres for the localized treatment of kidney tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bilateral Arterial Embolization of the Prostate Through a Single Prostatic Artery: A Case Series

Peri-prostatic shunts are frequent during PAE, carrying the risk of non-target embolization of penis/corpus cavernosum or rectum but also the potential advantage to irrigate the contralateral lobe. Sometimes, bilateral embolization is impossible, carrying the risk of limited clinical success. The possibility to reach contralateral prostatic territory from the ipsilateral prostatic artery (PA) and embolize it via peri/intra-prostatic anastomoses could be of interest in this situation. We describe a series of three consecutive patients (among 89 consecutive patients treated by PAE for symptomatic BPH) who underwent successful embolization of both prostatic lobes through catheterization of a PA on only one side. All patients had clinical success after a mean follow-up of 3.3 months. Dosimetry of these three procedures indicates that there may be radiation dose savings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Isolated Hepatic Perfusion as a Treatment for Isolated Hepatic Metastases of Uveal Melanoma: Patient Outcome and Safety in a Multi-centre Study

PurposePercutaneous isolated hepatic perfusion (PIHP) with Melphalan has been developed as a treatment for patients with isolated hepatic metastases of uveal melanoma. We discuss patient outcome and safety in a retrospective multi-centre study.Materials and MethodsBetween 2012 and 2016 18 patients with un-resectable isolated hepatic metastases of uveal melanoma received single or repeated PIHP with Melphalan (n = 35) at seven sites. Progression-free time, overall survival time (OS) and tumour response by means of RECIST 1.1 criteria were evaluated. Peri- and post-procedural adverse events (AE) were registered. Patients’ life quality was assessed using four-point scale questionnaires.ResultsOf 18 patients, initial PIHP treatment resulted in partial response (PR) in eight, stable disease (SD) in seven and progressive disease (PD) in three cases. Nine patients underwent second PIHP with PR in eight cases and PD in one case. Six patients were evaluated after third PIHP with PR in five patients and SD in one patient. Two patients received fourth PIHP with PD in both cases. Median OS was 9.6 months (range 1.6–41.0 months). Median progression-free survival time was 12.4 months (range 0.9–41.0 months) with 1-year survival of 44%. Most common post-procedural AE grade 3 and 4 were temporary leukopenia (n = 11) and thrombocytopenia (n = 8). Patients’ self-assessments showed good ratings for overall health and quality of life with only slight changes after PIHP, and a high degree of satisfaction with PIHP treatment.ConclusionPIHP with Melphalan proved to be a relatively safe, minimal-invasive and repeatable treatment for patients with non-resectable hepatic metastases of uveal melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Cryotherapy for Treatment of Chondroblastoma: Early Experience

Surgical curettage is currently the standard of care for the chondroblastoma, but in peri-articular tumors it is limited by its morbidity. In this preliminary report, we evaluate the feasibility of percutaneous cryotherapy as an alternative ablative treatment for chondroblastoma. Three patients with a chondroblastoma treated by CT scan-guided cryotherapy are presented in this article. Pain permanently disappeared 2 days after the procedure. No local tumor recurrence or cartilage damage was observed by MRI performed 1 year after the intervention. This preliminary case report suggests that percutaneous cryotherapy may be a possible alternative to the current standard of care in chondroblastoma. Further studies are needed to evaluate if this technique offers similar anti-tumoral efficacy while providing better pain relief and less morbidity than curettage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Onyx Embolization for Occlusion of the Proximal Internal Iliac Artery During EVAR in Patients with Unsuitable Landing Zones in the Common Iliac Artery

Background: Twenty percent of the patients with AAA have an aneurysm involving the common iliac arteries. Large common iliac diameter can be treated with an iliac branched device or extension of the stent graft to the external iliac artery with occlusion of the ipsilateral internal iliac artery (IIA) to prevent type 2 endoleaks. This study describes and evaluates a embolization technique using Onyx in conjunction with EVAR in aneurysms with poor landing zones in the common iliac arteries. Methods: Patients with Onyx IIA embolization during EVAR, identified from the hospital operating code database, constitute the study population. Onyx embolization was performed by injection at the IIA origin. Peri- and postoperative complications were collected from the medical records. Thin-sliced CT scan was performed 1 month and 1 year after the procedure. Results: Thirty-six patients with complex iliac anatomy and insufficient landing zones (without sealing possibility for standard stent grafts) were identified out of 243 consecutive EVAR treatments during a 13-year period. In seventeen patients (7%), the IIA was embolized with Onyx. Technical success was obtained in all 17 patients, without adverse event or procedural complication. No complication related to the embolization procedure was noted during follow-up. Conclusions: During EVAR treatment of patients with aneurysm involving the common iliac artery, Onyx embolization of IIA is a feasible option without need of selective catheterization of the IIA orifice, potentially preserving important branches of the IIA and simplifying emergency procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Extra-Anatomic Femoro-Popliteal Bypass for Limb Salvage in Chronic Critical Limb Ischemia

Purpose: To report the initial clinical experience with fully endovascular extra-anatomic femoro-popliteal bypass (FPB) for limb salvage in patients with critical limb ischemia (CLI) and no traditional endovascular or surgical revascularization options. Methods: Between June 2013 and May 2018, endovascular procedure was proposed for limb salvage during multidisciplinary team meeting in fifteen hospitalized patients (median age 67 years; 73% men) with CLI and a high risk of major amputation. Primary outcome was amputation-free survival at 1 year. Secondary outcomes included mortality, cardiovascular (CV) events and major limb amputation at 1 year, primary/secondary bypass patency and wound healing at the last follow-up visit. Procedure-related complications (deaths, CV events, hemorrhages) were recorded through 30 days. Results: Technical procedure success rate was 100%. Major peri-procedural outcomes occurred in two patients (13%): One patient died secondary to cardiogenic shock; one patient suffered acute coronary syndrome associated with iliopsoas bleeding. No major amputation occurred through 30 days. Median follow-up period was 21.5 (18.25–45.5) months (last follow-up visits on April 2019). Amputation-free survival at 1-year and at the last follow-up visit was 80% and 53%, respectively. Cumulative mortality at 1-year and at the last follow-up visit was 13% and 33%, respectively. Primary and secondary bypass patency was 27% and 60%, respectively. Complete wound healing was achieved in 11 patients (73%). Conclusion: Endovascular extra-anatomic FPB represents an innovative approach for limb salvage in CLI with no traditional endovascular or surgical revascularization options. Our clinical experience highlights that this technique remains challenging because of frequent comorbidities and fragility of this patient population. Level of Evidence: Level 4, Case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation of Renal Cell Carcinoma of the Transplanted Kidney: Two Cases

Thermal ablative techniques have been increasingly recognized as a valuable alternative to graftectomy and nephron-sparing surgery for the treatment of small neoplasms arising in the transplanted kidney. However, long-term efficacy and safety data are still lacking. In particular, current experience with microwave ablation is limited to a very recent single-centre series of three cases. We herein report two microwave ablations of renal cell carcinoma of the kidney allograft. The procedures were successfully performed under ultrasound guidance with complete tumour necrosis, no peri-operative complications, and preserved renal function. No recurrences were observed after 3 years of follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overexpression and topology of bacterial oligosaccharyltransferase PglB

Campylobacter jejuni contains a post-translational N-glycosylation system in which a STT3 homologue, PglB, functions as the oligosaccharyltransferase. Herein, we established a method for obtaining relatively large quantities of homogenous PglB proteins. PglB was overexpressed in Escherichia coli C43(DE3) at a level of 1 mg/L cell cultures. The activity of purified PglB was verified using a chemically synthesized sugar donor: N-acetylgalactosamine-diphospho-undecaprenyl (GalNAc-PP-Und) and a synthesized peptide acceptor. The result confirms that PglB is solely responsible for the oligosaccharyltransferase activity and complements the finding that PglB exhibits relaxed sugar substrate specificity. In addition, we performed the topology mapping of PglB using the PhoA/LacZ fusion method. The topological model shows that PglB possesses 11 transmembrane segments and two relatively large periplasmic regions other than the C-terminal domain, which is consistent with the proposal of the common N{sub cyt}-C{sub peri} topology with 11 transmembrane segments for the STT3 family proteins.

60 APPLIED LIFE SCIENCES↗

Vimentin binds IRAP and is involved in GLUT4 vesicle trafficking

Research highlights: {yields} Vimentin is shown to bind to the N-terminus of insulin-responsive aminopeptidase (IRAP), a major cargo protein of GLUT4 vesicles in 3T3-L1 adipocytes. {yields} GLUT4 translocation to the plasma membrane by insulin is decreased in vimentin-depleted adipocytes. {yields} An interaction between vimentin and IRAP functions to sequester GLUT4 vesicles to the peri-nuclear region of the cell. -- Abstract: Insulin-responsive aminopeptidase (IRAP) and GLUT4 are two major cargo proteins of GLUT4 storage vesicles (GSVs) that are translocated from a postendosomal storage compartment to the plasma membrane (PM) in response to insulin. The cytoplasmic region of IRAP is reportedly involved in retention of GSVs. In this study, vimentin was identified using the cytoplasmic domain of IRAP as bait. The validity of this interaction was confirmed by pull-down assays and immunoprecipitation in 3T3-L1 adipocytes. In addition, it was shown that GLUT4 translocation to the PM by insulin was decreased in vimentin-depleted adipocytes, presumably due to dispersing GSVs away from the cytoskeleton. These findings suggest that the IRAP binding protein, vimentin, plays an important role in retention of GSVs.

60 APPLIED LIFE SCIENCES↗