Contrasting changes in ozone during 2019–2021 between eastern and the other regions of China attributed to anthropogenic emissions and meteorological conditions

Ozone pollution is one of the most severe air quality issues in China that poses a serious threat to human health and ecosystems. During 2019–2021, the maximum daily 8-h average ozone concentrations in eastern China (110–122.5°E, 26–42°N) and the rest of China (ROC) show different decreasing patterns, with ozone concentrations in eastern China decreasing by 14.9 μg/m 3 , which is much larger than 4.8 μg/m 3 in ROC. Here, based on two independent methods, the atmospheric chemical transport model (GEOS-Chem) simulations and the machine learning (ML) model (LightGBM) predictions, the reasons for the differences in ozone changes between eastern China and ROC during the warm season (April to September) are investigated. According to the GEOS-Chem (LightGBM) results, changes in the meteorological conditions contributed to an ozone decrease by 7.3 (6.8) μg/m 3 in eastern China due to decreased chemical production and an ozone decrease by 6.8 (7.0) μg/m 3 in ROC attributed to the weakened horizontal and vertical advection. With the influence of meteorological factors excluded, the observations show that changes in anthropogenic emissions resulted in an ozone decrease by 7.6 (8.1) μg/m 3 in eastern China and an ozone increase by 2.0 (2.2) μg/m 3 in ROC, which is primarily induced by the changes in NO x emissions. The surface measurements and satellite retrievals also indicate that the reduction in NO x emissions in ROC is less efficient than that in the more developed eastern China, leading to contrasting changes in ozone concentrations between eastern China and ROC during 2019–2021. In conclusion, our results highlight the critical need to reduce ozone precursor emissions in the rest regions of China apart from eastern China.

54 ENVIRONMENTAL SCIENCES↗

Fiber-Optic Coupled Lidar Receiver System to Measure Stratospheric Ozone

The measurement of ozone in the atmosphere has become increasingly important over the past two decades. Significant increases of ozone concentrations in the lower atmosphere, or troposphere, and decreases in the upper atmosphere, or stratosphere, have been attributed to man-made causes. High ozone concentrations in the troposphere pose a health hazard to plants and animals and can add to global warming. On the other hand, ozone in the stratosphere serves as a protective barrier against strong ultraviolet (UV) radiation from the sun. Man-made CFC's (chlorofluorocarbons) act as a catalyst with a free oxygen atom and an ozone molecule to produce two oxygen molecules therefore depleting the protective layer of ozone in the stratosphere. The beneficial and harmful effects of ozone require the study of ozone creation and destruction processes in the atmosphere. Therefore, to provide an accurate model of these processes, an ozone lidar system must be able to be used frequently with as large a measurement range as possible. Various methods can be used to measure atmospheric ozone concentrations. These include different airborne and balloon measurements, solar occulation satellite techniques, and the use of lasers in lidar (high detection and ranging,) systems to probe the atmosphere. Typical devices such as weather balloons can only measure within the direct vicinity of the instrument and are therefore used infrequently. Satellites use solar occulation techniques that yield low horizontal and vertical resolution column densities of ozone.

Harper, David Brent↗

Power plant fuel switching and air quality in a tropical, forested environment

How a changing energy matrix for electricity production affects air quality is considered for an urban region in a tropical, forested environment. Manaus, the largest city in the central Amazon Basin of Brazil, is in the process of changing its energy matrix for electricity production from fuel oil and diesel to natural gas over an approximately 10-year period, with a minor contribution by hydropower. Three scenarios of urban air quality, specifically afternoon ozone concentrations, were simulated using the Weather Research and Forecasting (WRF-Chem) model. The first scenario used fuel oil and diesel for electricity production, which was the reality in 2008. The second scenario was based on the fuel mix from 2014, the most current year for which data were available. The third scenario considered nearly complete use of natural gas for electricity production, which is the anticipated future, possibly for 2018. For each case, inventories of anthropogenic emissions were based on electricity generation, refinery operations, and transportation. Transportation and refinery operations were held constant across the three scenarios to focus on effects of power plant fuel switching in a tropical context. The simulated NO x and CO emissions for the urban region decrease by 89 and 55 %, respectively, after the complete change in the energy matrix. The results of the simulations indicate that a change to natural gas significantly decreases maximum afternoon ozone concentrations over the population center, reducing ozone by >70 % for the most polluted days. The sensitivity of ozone concentrations to the fuel switchover is consistent with a NO x -limited regime, as expected for a tropical forest having high emissions of biogenic volatile organic compounds, high water vapor concentrations, and abundant solar radiation. There are key differences in a shifting energy matrix in a tropical, forested environment compared to other world environments. Therefore, policies favoring the burning of natural gas in place of fuel oil and diesel have great potential for ozone reduction and improved air quality for growing urban regions located in tropical, forested environments around the world.

54 ENVIRONMENTAL SCIENCES↗

Ozone contamination in aircraft cabins: Objectives and approach

Three panels were developed to solve the problem of ozone contamination in aircraft cabins. The problem is defined from direct in-flight measurements of ozone concentrations inside and outside airliners in their normal operations. Solutions to the cabin ozone problem are discussed under two areas: (1) flight planning to avoid high ozone concentrations, and (2) ozone destruction techniques installed in the cabin air systems.

Perkins, P. J.↗

Surface ozone levels at Table Mountain during STOIC 1989

As a part of the routine operations of the Jet Propulsion Laboratory atmospheric measurements program at the Table Mountain Facility, the surface ozone concentration is continuously monitored using a Dasibi photometer. The influence of the Los Angeles basin to the southwest of the facility and the height of the inversion layer cause large fluctuations in the ozone concentration. Peaks as high as 200 parts per billion by volume (ppbv) were observed during the Stratospheric Ozone Intercomparison Campaign (STOIC) compared to a normal background level near 50 ppbv. These measurements, made during STOIC, were important in assessing the impact of the surface ozone concentration on the various instruments participating in the campaign.

McDermid, I. Stuart↗

Stratospheric Ozone Climatology from Lidar Measurements at Table Mountain (34.0 deg N, 117.7 deg W) and Mauna Loa (19.5 deg N, 155.6 deg W)

Using more than 1600 nighttime profiles obtained by the JPL differential absorption lidars (DIAL) located at Table Mountain Facility (TMF, 34.4 N) and Mauna Loa Observatory (MLO, 19.5 N) is presented in this paper. These two systems have been providing high-resolution vertical profiles of ozone number density between 15-50 km, several nights a week since 1989 (TMF) and 1993 (MLO). The climatology presented here is typical of early night ozone values with only a small influence of the Pinatubo aerosols and the 11-year solar cycle. The observed seasonal and vertical structure of the ozone concentration at TMF is consistent with that typical of mid- to subtropical latitudes. A clear annual cycle in opposite phase below and above the ozone concentration peak is observed. The observed winter maximum below the ozone peak is associated with a maximum day-to-day variability, typical of a dynamically driven lower stratosphere. The maximum concentration observed in summer above the ozone peak emphasizes the more dominant role of photochemistry. Unlike TMF, the ozone concentration observed at MLO tends to be higher during the summer months and lower during the winter months throughout the entire stratospheric ozone layer. Only a weak signature of the extra-tropical latitudes is observed near 19-20 km, with a secondary maximum in late winter. The only large variability observed at MLO is associated with the natural variability of the tropical tropopause.

Leblanc, T.↗

The 1977 surface ozone study of eastern Virginia

Data were collected by primarily twelve ground stations positioned throughout the eastern shore - tidewater area of Virginia and North Carolina. From an analysis of the ozone and wind data, certain trends were found such as the existence of a bias in ozone concentrations between stations and a linear correlation between average ozone concentration and latitude. In addition, higher ozone levels were found with surface winds from certain preferred directions at the various sites. The results, however, do not substantiate ozone or ozone precursor transport.

Williams, M. E.↗

The effect of the sea breeze circulation on surface ozone levels at Wallops Island, Virginia

Surface measurements of windspeed, direction, and ozone concentration collected at Wallops Island, Virginia, during the summers of 1977 and 1978 are analyzed to study the effects of the dominant mesoscale sea breeze circulation on the local photochemical oxidant levels. A bimodality in the atmospheric dynamics is linked to systematic variations in ozone concentration. It is concluded that during certain phases of the two circulation modes, increased wind speed reduces the resistance of the earth's surface to the deposition of ozone, and decreased ozone concentration levels result. For other phases, light winds occur, signifying high resistance to deposition and high ozone levels. This modulation by the local dynamics is a major impediment for pollutant studies in coastal environments, especially those centering on transport, because it tends to mask other processes that may be occurring.

Parsons, C. L.↗

Ozone measurements in the troposphere of an Amazonian rain forest environment

Ozone concentration profiles from the ground to above the stratospheric peak were obtained in an equatorial rain forest environment near Manaus in the Amazon Basin between July and August of 1985. The peak ozone concentration (4.4 x 10 to the 22 molecules/cu cm) was found at 20 mbar (26.6 km). A major pollution (biomass-burning) event which occurred near the end of the experiment was responsible for large changes in ozone concentration.

Kirchhoff, V. W. J. H.↗

Impacts of compound extreme weather events on ozone in the present and future

The Weather Research and Forecasting model coupled with Chemistry (WRF-Chem) was used to study the effect of extreme weather events on ozone in the US for historical (2001–2010) and future (2046–2055) periods under the RCP8.5 scenario. During extreme weather events, including heat waves, atmospheric stagnation, and their compound events, ozone concentration is much higher compared to the non-extreme events period. A striking enhancement of effect during compound events is revealed when heat wave and stagnation occur simultaneously as both high temperature and low wind speed promote the production of high ozone concentrations. In regions with high emissions, compound extreme events can shift the high-end tails of the probability density functions (PDFs) of ozone to even higher values to generate extreme ozone episodes. In regions with low emissions, extreme events can still increase high-ozone frequency but the high-end tails of the PDFs are constrained by the low emissions. Despite the large anthropogenic emission reduction projected for the future, compound events increase ozone more than the single events by 10 to 13%, comparable to the present, and high-ozone episodes with a maximum daily 8h average (MDA8) ozone concentration over 70ppbv are not eliminated. Using the CMIP5 multi-model ensemble, the frequency of compound events is found to increase more dominantly compared to the increased frequency of single events in the future over the US, Europe, and China. High-ozone episodes will likely continue in the future due to increases in both frequency and intensity of extreme events, despite reductions in anthropogenic emissions of its precursors. However, the latter could reduce or eliminate extreme ozone episodes; thus improving projections of compound events and their impacts on extreme ozone may better constrain future projections of extreme ozone episodes that have detrimental effects on human health.

54 ENVIRONMENTAL SCIENCES↗

Positive direct current corona discharges in single wire-duct electrostatic precipitators

This paper is aimed to study the characteristics of the positive dc corona discharges in single wire-duct electrostatic precipitators. Therefore, the corona discharges were formed inside dry air fed single wire-duct reactor under positive dc voltage at the normal atmospheric conditions. The corona current-voltage characteristics curves have been measured in parallel with the ozone concentration generated inside the reactor under different discharge conditions. The corona current-voltage characteristics curves have agreed with a semi empirical equation derived from the previous studies. The experimental results of the ozone concentration generated inside the reactor were formulated in the form of an empirical equation included the different parameters that were studied experimentally. The obtained equations are valid to expect both the current-voltage characteristics curves and the corresponding ozone concentration that generates with the positive dc corona discharges inside single wire-duct electrostatic precipitators under any operating conditions in the same range of the present study.

54 ENVIRONMENTAL SCIENCES↗

The significance of biomass burning as a source of carbon monoxide and ozone in the Southern Hemisphere tropics - A satellite analysis

Carbon monoxide mixing ratios obtained by the October 1984 Measurement of Air Pollution from Satellites (MAPS) experiment are compared with the distribution of October 1984 Total Ozone Mapping Spectrometer (TOMS) ozone concentrations. The TOMS and MAPS data show coincident high values of ozone and carbon monoxide over central South America and southeastern Africa. The 1984 MAPS data are also compared with tropospheric ozone concentrations derived from 6 years of TOMS and Stratospheric Aerosol and Gas Experiment (SAGE) I and II measurements. Examination of the October climatological distribution of tropospheric ozone also reveals high concentrations over central South America and southeastern Africa. These coincident high values of CO and ozone in the rural southern tropics are most likely due to biomass burning and the subsequent transport of CO and ozone by large-scale weather patterns. It appears that both CO and ozone are being transported thousands of kilometers from their source regions by the prevailing winds.

Watson, Catherine E.↗

The Effect of Entrainment Through Atmospheric Boundary Layer Growth on Observed and Modeled Surface Ozone in the Colorado Front Range

Ozone concentrations at the Earth's surface are controlled by meteorological and chemical processes and are a function of advection, entrainment, deposition, and net chemical production/loss. The relative contributions of these processes vary in time and space. Understanding the relative importance of these processes controlling surface ozone concentrations is an essential component for designing effective regulatory strategies. Here we focus on the diurnal cycle of entrainment through atmospheric boundary layer (ABL) growth in the Colorado Front Range. Aircraft soundings and surface observations collected in July/August 2014 during the DISCOVER-AQ/FRAPPÉ (Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality/Front Range Air Pollution and Photochemistry Éxperiment) campaigns and equivalent data simulated by a regional chemical transport model are analyzed. Entrainment through ABL growth is most important in the early morning, fumigating the surface at a rate of ~5 ppbv/h. The fumigation effect weakens near noon and changes sign to become a small dilution effect in the afternoon on the order of -1 ppbv/h. The chemical transport model WRF-Chem (Weather Research and Forecasting Model with chemistry) underestimates ozone at all altitudes during this study on the order of 10-15 ppbv. The entrainment through ABL growth is overestimated by the model in the order of 0.6-0.8 ppbv/h. This results from differences in boundary layer growth in the morning and ozone concentration jump across the ABL top in the afternoon. This implicates stronger modeled fumigation in the morning and weaker modeled dilution after 11:00 LT.

Entrainment through ABL Growth↗

The Development of a Stochastic Model of the Atmosphere Between 30 and 90 Km to Be Used in Determining the Effect of Atmospheric Variability on Space Shuttle Entry Parameters

A stochasitc model of the atmosphere between 30 and 90 km was developed for use in Monte Carlo space shuttle entry studies. The model is actually a family of models, one for each latitude-season category as defined in the 1966 U.S. Standard Atmosphere Supplements. Each latitude-season model generates a pseudo-random temperature profile whose mean is the appropriate temperature profile from the Standard Atmosphere Supplements. The standard deviation of temperature at each altitude for a given latitude-season model was estimated from sounding-rocket data. Departures from the mean temperature at each altitude were produced by assuming a linear regression of temperature on the solar heating rate of ozone. A profile of random ozone concentrations was first generated using an auxiliary stochastic ozone model, also developed as part of this study, and then solar heating rates were computed for the random ozone concentrations.

Campbell, J. W.↗

Influence of Mid-Latitude Cyclones on European Background Surface Ozone Investigated in Observations, MACC and MERRA-2 Reanalyses

The relationship between springtime mid-latitude cyclones and background ozone at two rural monitoring sites on the west coast of Europe -- Mace Head, Ireland and Monte Velho, Portugal -- is explored using a combination of observations and three reanalyses: 1) the European Centre for Medium-Range Weather Forecasts' (ECMWF) ERA-Interim reanalysis, 2) the Monitoring Atmospheric Composition and Climate (MACC) reanalysis and 3) NASA's Modern-Era Retrospective Analysis for Research and Applications Version-2 (MERRA-2) reanalysis. The ERA-Interim cyclone tracks are used here to establish the long-term relationship between cyclones and ozone observations (since 1988). The MACC reanalysis data set, which covers the period 2003-2012, is produced with the ECMWF integrated forecast system (IFS) model two-way coupled to a chemistry transport model (CTM). Since the MACC reanalysis uses a similar atmospheric model to ERA-Interim, MACC is used to explore the mechanisms within the case study cyclones that can influence surface ozone concentrations at Mace Head and Monte Velho. The MERRA-2 reanalysis also provides 3D distributions of ozone, although less ideal for analysis of surface ozone concentrations since MERRA-2 ozone under represents ozone variability outside the stratosphere as it does not have a detailed chemistry scheme or emission sources for the troposphere. The MERRA-2 reanalysis, which has the potential to identify more features within the cyclones as the resolution is higher than the MACC reanalysis, is used in conjunction with the MACC reanalysis to provide a measure of uncertainty to the case study analysis. We found the main source of high ozone to these two sites is from the stratosphere, which is well represented in both the MERRA-2 and the MACC reanalyses, either from direct injection into the cyclone or associated with aged airstreams from decaying downstream cyclones that can become entrained and descend toward the surface within new cyclones over the NA region.

MERRA-2↗

Measured trends in stratospheric ozone

Recent findings, based on both ground-based and satellite measurements, have established that there has been an apparent downward trend in the total column amount of ozone over mid-latitude areas of the Northern Hemisphere in all seasons. Measurements of the altitude profile of the change in the ozone concentration have established that decreases are taking place in the lower stratosphere in the region of highest ozone concentration. Analysis of updated ozone records, through March of 1991, including 29 stations in the former Soviet Union, and analysis of independently calibrated satellite data records from the Total Ozone Mapping Spectrometer and Stratospheric Aerosol and Gas Experiment instruments confirm many of the findings originally derived from the Dobson record concerning northern midlatitude changes in ozone. The data from many instruments now provide a fairly consistent picture of the change that has occurred in stratospheric ozone levels.

Stolarski, Richard↗

Urban and Rural Ozone Pollution Over Lusaka (Zambia, 15.5S, 25E) During SAFARI-2000 (September 2000)

In early September, throughout south central Africa, seasonal clearing of dry vegetation and the production of charcoal for cooking leads to intense smoke haze and ozone formation. Ozone soundings made over Lusaka during a six-day period in early September 2000 recorded layers of high ozone (greater than 125 ppbv at 5 km) during two stagnant periods, interspersed by a frontal passage that reduced boundary layer ozone by 30 percent. Smoke aerosol column variations aloft and total ozone were monitored by a sun photometer. During the 6-day measurement period, surface ozone concentrations ranged from 50-95 ppbv and integrated tropospheric ozone from the soundings was 39- 54 Dobson Units (note 1.3 km elevation at the launch site). High ozone concentrations above the mixed and inversion layers were advected from rural burning regions in western Zambia where SAFARI aircraft and ground-based instruments observed intense biomass fires and elevated aerosol and trace gas amounts. TOMS tropospheric ozone and smoke aerosols products show the distribution of biomass burning and associated pollution throughout southern Africa in September 2000. Animations of satellite images and trajectories confirm pollutant recirculation over south central African fires, exit of ozone from Mozambique and Tanzania to the Indian Ocean and the characteristic buildup of tropospheric ozone over the Atlantic from western African outflow.

Thompson, Anne M.↗

Observation of atmospheric ozone by dial with Raman lasers pumped by a KrF laser

Since the XeCl excimer laser (308 nm) was first used in Differential Absorption Lidar (DIAL) for stratospheric ozone detection, the XeCl ozone lidar became a useful tool for the monitoring of the stratospheric ozone concentration. Shorter wavelength lasers are needed for the observation of ozone in the troposphere where the ozone concentration is about one order of magnitude smaller than in the stratosphere. In 1983, tropospheric ozone was observed with the combination of the second Stokes line (290.4 nm) of stimulated Raman scattering from methane pumped by a KrF laser and the XeCl laser line. The measurement of the ozone distribution from ground to 30 km was reported, using three Stokes lines of Raman lasers pumped by a KrF laser. At wavelengths shorter than 295 nm, the background solar radiation is effectively suppressed by atmospheric ozone. Such a solar-blind effect can be expected when two wavelengths 277 and 290.4 nm are used for DIAL ozone detection. A preliminary measurement of the day time ozone distribution in the troposphere is presented using these wavelengths generated by a KrF laser with a Raman shifter. Analysis using the lidar equation predicts the maximum detectable range is 7 km.

Maeda, M.↗