At least 73 records · Page 4

Spherical harmonic analysis of a synoptic climatology generated with a global general circulation model

Spherical harmonic analysis was used to analyze the observed climatological (C) fields of temperature at 850 mb, geopotential height at 500 mb, and sea level pressure. The spherical harmonic method was also applied to the corresponding "model climatological" fields (M) generated by a general circulation model, the "GISS climate model." The climate model was initialized with observed data for the first of December 1976 at 00. GMT and allowed to generate five years of meteorological history. Monthly means of the above fields for the five years were computed and subjected to spherical harmonic analysis. It was found from the comparison of the spectral components of both sets, M and C, that the climate model generated reasonable 500 mb geopotential heights. The model temperature field at 850 mb exhibited a generally correct structure. However, the meridional temperature gradient was overestimated and overheating of the continents was observed in summer.

Christidis, Z. D.↗

Fabrication and Testing of Polyvinylidene Fluoride Capacitors

High energy density capacitors made from metallized polyvinylidene fluoride film were built and tested. Terminations of aluminum-babbitt, tin-babbitt, and all-babbitt were evaluated. All-babbit terminations appeared to be better. The 0.1 microfarad and 2 microfarad capacitors were made of 6 micrometer material. Capacitance, dissipation factor, and insulation resistance measurements were made over the ranges -55 C to 125 C and 10 Hz to 100 kHz. Twelve of forty-one 0.1 microfarad capacitors survived a 5000 hour dc plus ac life test. Under the same conditions, the 2 microfarad capacitors exhibited overheating because of excessive power loss. Some failures occurred after low temperature exposures for 48 hours. No failures were caused by vibration or temperature cycling.

Buritz, R. S.↗

Fuse Protects Parabolic-Dish Solar Collector

Sliding barrel and shutter protect against overheating. Downward movement of shutter initiated by melting of fuse wire that suspends it. Shutter lowered or raised under operator's control by depressuring or pressurizing hydraulic cylinder.

Selcuk, M. K.↗

Accelerated Solar-UV Test Chamber

Medium-pressure mercury-vapor lamps provide high ratio of ultraviolet to total power. Chamber for evaluating solar-ultraviolet (UV) radiation damage permits accelerated testing without overheating test specimens.

Gupta, A.↗

Memory-Metal Electromechanical Actuators

Electrically controlled actuator produces predetermined force, torque, or displacement without motors, solenoids, or gears. Using memory-metal elements, actuator responds to digital input without electronic digitalto-analog conversion. To prevent overheating and consequent loss of hotformed shape, each element protected by thermostat turns off current when predetermined temperature is exceeded. Memory metals used to generate fast mechanical response to electric signals.

Ruoff, C. F.↗

Analysis of spiral-groove face seals for liquid oxygen

Analyses and predicted performance of a 50-mm diameter, spiral-groove face seal to seal liquid oxygen at 5.17 MPa pressure, and operating at surface speeds of 183 m/s are described. The pressure-balanced spiral-groove concept is introduced that circulates spiral-groove flow independent of leakage flow. Independent flow paths preclude overheating from vaporization and consequent flow blockage. The analysis accounts for fluid turbulence and inertia, thermoelastic distortions, and dynamic response. An operating-range map was developed as a function of speed and pressure. The fluid-film analysis is summarized in the Appendix.

Shapiro, W.↗

Telescoping Shield for Point-Focusing Solar Concentrators

Telescoping shield normally stowed around solar receiver protects heat engine and supporting structure from overheating when concentrator aimed few degrees away from line to Sun. When extended, shield intercepts off center concentrated solar radiation. Heat spread out over thermally conductive shield and reradiated diffusely not to cause structural damage.

Argoud, M.↗

Failure analysis of plasma-sprayed thermal barrier coatings

Thermally induced failure processes of plasma-sprayed thermal barrier coatings are examined. Cracking processes give rise to noise which was monitored by acoustic emission (AE) techniques. The sequential failure of coatings was examined from samples which were thermally cycled. Coatings of yttria-stabilized zirconia with and without a NiCrAlZr bond coat were plasma-sprayed onto U700 alloy rod. In some cases the substrate was intentionally overheated during deposition of the thermal protection system to check how this process variable influenced the AE response of the specimen. In this way a qualitative appraisal of how process variables affect coating integrity could be discerned in terms of cracking behavior. Results from up to seven consecutive thermal cycles are reported here. Coating failure was observed in all cases. Failure of the thermal protection system is progressive, since cracking and crack growth were observed prior to ultimate failure. Thus castastrophic failure occurs at some stage when there is a transformation from the microcrack to a macrocrack network.

Berndt, C. C.↗

Improving Emittance of High-Temperature Insulating Tile

Simple addition to ceramic insulating tiles provides backup properties that minimize transfer of heat through tiles when their surfaces become damaged. Addition of 3 percent by weight of 320- or 600-grit silicon carbide powder to ceramic during production results in impregnated tile material that resists overheating. Silicon carbide increases emittance and decreases transmittance of ceramic.

Gzowski, E. R.↗

Reducing Coal Dust With Water Jets

Jets also cool and clean cutting equipment. Modular pick-and-bucket miner suffers from disadvantage: Creates large quantities of potentially explosive coal dust. Dust clogs drive chain and other parts and must be removed by hand. Picks and bucket lips become overheated by friction and be resharpened or replaced frequently. Addition of oscillating and rotating water jets to pick-and-bucket machine keeps down dust, cools cutting edges, and flushes machine. Rotating jets wash dust away from drive chain. Oscillating jets cool cutting surfaces. Both types of jet wet airborne coal dust; it precipitates.

Gangal, M. D.↗

Development of a temperature measurement system with application to a jet in a cross flow experiment

A temperature measurement system, which allows the simultaneous sampling of up to 80 separate thermocouples, was developed. The minimum resolution for the system corresponds to + or - 0.16 C per least significant bit of the A/D converter. The time constant values lambda, for each of the 64 thermocouples, were determined experimentally at 7 mps. Software routines were used to correct the measured temperatures for the effect of lambda for each thermocouple. The temperature measurement system was utilized to study the thermal field of a heated jet discharging perpendicularly into a low and a high disturbance level cross stream for a given momentum flux ratio and for three overheated values. The peak instantaneous temperatures reveal that strong molecular diffusion was operative. Various measures of the thermal field, for the disturbed case, suggest that the jet column remains relatively compact while being buffeted by the ambient turbulence field and that its penetration, into the cross wind, is inhibited by the presence of the strong disturbance field.

Wark, C.↗

Results of tests of Insta-Foam Thermal Protection System (TPS) material for protection of equipment inside the SRB aft skirt

The objective of these tests was to determine whether Insta-Foam can be used successfully to protect items inside the solid rocket booster aft skirt during reentry. On some of the early Space Shuttle flights the aft skirt heat shield curtain failed during reentry. This allowed the hot gases to damage some of the equipment, etc., inside the skirt. For example, some of the propellant lines were overheated and ruptured and some of the NSI (nozzle severance) cables were damaged. It was suggested that the Insta-Foam thermal protection system be sprayed over these lines, etc., to protect them during future flights in case of a curtain failure. The tests presented were devised and run to check out the feasibility of this idea.

Dean, W. G.↗

Monitoring Temperatures Indirectly in Cooled Combustors

Noninvasive monitoring of temperatures on inner surface of combustion liner of cooled combustor increases liner life, thereby increasing combustor reliability and performance. Technique used in furnaces, reactors, jet engines, rocket engines, stationary turbines, combustors, and heat exchangers. Growth of internal overheating streaks monitored using output from array of thermocouples on outside wall of combustor. Computer analysis of output indicates temperature pattern on combustor lining. Use of data enables timely liner maintenance or overhaul.

Wagner, W.↗

AC motor and generator requirements for isolated WECS

After surveying electrically driven loads used on productive farms, the investigators chose three pumps for testing at voltages and frequencies far outside the normal operating range. These loads extract and circulate water and move heat via air, and all are critical to farm productivity. The object was to determine the envelope of supply voltage and frequency over which these loads would operate stably for time intervals under 1 hour. This information is among that needed to determine the feasibility of supplying critical loads, in case of a utility outage, from a wind driven alternator whose output voltage and frequency will vary dramatically in most continental wind regimes. Other related work is surveyed. The salient features and limitations of the test configurations used and the data reduction are described. The development of simulation models suitable for a small computer are outlined. The results are primarily displayed on the voltage frequency plane with the general conclusion that the particular pump models considered will operate over the range of 50 to 90 Hz and a voltage band which starts below rated, decreases as frequency decreases, and is limited on the high side by excessive motor heating. For example, centrifugal pump operating voltage ranges as extensive .4 to 1.4 appear possible. Particular problems with starting, stalling due to lack of motor torque, high speed cavitation, and likely overheating are addressed in a listing of required properties for wind driven alternators and their controllers needed for use in the isolated or stand alone configuration considered.

Park, G. L.↗

Failure analysis of plasma-sprayed thermal barrier coatings

Thermally induced failure processes of plasma-sprayed thermal barrier coatings are examined. Cracking processes give rise to noise which was monitored by acoustic emission (AE) techniques. The sequential failure of coatings was examined from samples which were thermally cycled. Coatings of yttria-stabilized zirconia with and without a NiCrAlZr bond coat were plasma-sprayed onto U700 alloy rod. In some cases the substrate was intentionally overheated during deposition of the thermal protection system to check how this process variable influenced the AE response of the specimen. In this way a qualitative appraisal of how process variables affect coating integrity could be discerned in terms of cracking behavior. Results from up to seven consecutive thermal cycles are reported here. Coating failure was observed in all cases. Failure of the thermal protection system is progressive, since cracking and crack growth were observed prior to ultimate failure. Thus castastrophic failure occurs at some stage when there is a transformation from the microcrack to a macrocrack network.

Berndt, C. C.↗

Chromosphere flare models

Further calculated results based on the F1 and F2 chromospheric models of Machado et al. (1980) are presented in addition to results from a model with enhanced temperatures relative to the weak-flare model F1 in the upper photosphere and low chromosphere, and from a model with enhanced temperatures relative to the strong flare model F2 in the upper chromosphere. The coupled equations of statistical equilibrium and radiative transfer for H, H(-), He I-II, C I-IV, Si I-II, Mg I-II, Fe, Al, O I-II, Na, and Ca II are solved, and the overall absorption and emission of radiation by lines throughout the spectrum are determined by means of a reduced set of opacities taken from a compilation of over 10 million lines. Semiempirical models show that the white light flare continuum may arise by extreme chromospheric overheating, as well as by an enhancement of the minimum temperature region.

Avrett, E. H.↗

A heater made from graphite composite material for potential deicing application

A surface heater was developed using a graphite fiber-epoxy composite as the heating element. This heater can be thin, highly electrically and thermally conductive, and can conform to an irregular surface. Therefore it may be used in an aircraft's thermal deicing system to quickly and uniformly heat the aircraft surface. One-ply of unidirectional graphite fiber-epoxy composite was laminated between two plies of fiber glass-epoxy composite, with nickel foil contacting the end portions of the composite and partly exposed beyond the composites for electrical contact. The model heater used brominated P-100 fibers from Amoco. The fiber's electrical resistivity, thermal conductivity and density were 50 micro ohms per centimeter, 270 W/m-K and 2.30 gm/cubic cm, respectively. The electricity was found to penetrate through the composite in the transverse direction to make an acceptably low foil-composite contact resistance. When conducting current, the heater temperature increase reached 50 percent of the steady state value within 20 sec. There was no overheating at the ends of the heater provided there was no water corrosion. If the foil-composite bonding failed during storage, liquid water exposure was found to oxidize the foil. Such bonding failure may be avoided if perforated nickel foil is used, so that the composite plies can bond to each other through the perforated holes and therefore lock the foil in place.

Hung, C. C.↗

Prediction and rational correlation of thermophoretically reduced particle mass transfer to hot surfaces across laminar or turbulent forced-convection gas boundary layers

A formulation previously developed to predict and correlate the thermophoretically-augmented submicron particle mass transfer rate to cold surfaces is found to account for the thermophoretically reduced particle mass transfer rate to overheated surfaces such that thermophoresis brings about a 10-decade reduction below the convective mass transfer rate expected by pure Brownian diffusion and convection alone. Thermophoretic blowing is shown to produce effects on particle concentration boundary-layer (BL) structure and wall mass transfer rates similar to those produced by real blowing through a porous wall. The applicability of the correlations to developing BL-situations is demonstrated by a numerical example relevant to wet-steam technology.

Gokoglu, Suleyman A.↗