Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Outdoor environmental”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

200-IA-1 Operable Unit Human Health Risk and Kd Screen

The purpose of this environmental calculation file (ECF) is to provide the following: Document the data processing and data reduction steps taken to prepare the 200-IA-1 Operable Unit (OU) data set that will be used to calculate the sample-specific screening level human health risk evaluation; Document the data processing and data reduction steps taken to prepare the 200-IA-1 OU data set that will be used to identify analytes that could potentially impact groundwater in the future beneath the 200-IA-1 OU representative waste sites; Document the assumptions, equations, and methodologies used to calculate the screening levels for human health cancer risks and noncancer hazards for each representative waste site assigned to the 200-IA-1 OU. Individual measured soil concentrations from 0 to 4.6 m (15 ft) below ground surface (bgs) (shallow vadose zone) are used to calculate the total excess lifetime cancer risk (ELCR) and hazard index (HI) for the outdoor worker scenario to determine if there is a basis for remedial action. Individual measured soil concentrations from the ground surface to the groundwater table are used for the distribution coefficient (Kd) screen to identify analytes that could potentially impact groundwater in the future beneath the 200-IA-1 OU representative waste sites. This ECF supports DOE/RL-2020-51, 200-IA-1 OU Focused Feasibility Study, under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). A risk characterization based upon the evaluation of the health risk estimates developed in this ECF will be presented in the focused feasibility study report.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DISCOVR: Development of Integrated Screening, Cultivar Optimization, and Verification Research

The DISCOVR consortium has developed and is applying an integrated platform and workflow for standardized, deep characterization of highly productive and resilient microalgae strains. New strains are screened using three consecutive tiers in a conceptual down-selection funnel to arrive at the most promising strains. At tier I, strains are screened on gradient incubators to determine their temperature and salinity tolerance range, and to evaluate their resistance to infectious agents (e.g., chytrids). At tier II, the strains’ winter and summer season biomass productivities are quantified in Laboratory Environmental Algae Pond Simulator (LEAPS) photobioreactors, and biomass composition is determined under N-replete and N-deplete conditions. At tier III, the best winter and summer season strains are evaluated in indoor crash ponds to determine their resilience to induced infections, and strains are tested in outdoor raceway ponds to confirm high biomass productivity and culture stability. The top strains are then evaluated in seasonal SOT outdoor pond culture trials at AzCATI, the dedicated Department of Energy SOT (State of Technology) testbed. Additional research is carried out on evaluating growth promoting molecules, reducing the impact of oxygen inhibition, optimizing pond operational conditions, measuring compositional shift dynamics, developing integrated pest management strategies, analysing culture health using 96 well-plate tools, implementing spectroradiometric monitoring and using machine learning to predict culture crashes.

Huesemann, Michael H↗

Synthetic Digital Environments for Training Robots on Earth & Beyond [Poster]

Creating physical replicas of real-world environments to train robots for challenging outdoor tasks, whether constructing energy infrastructure like solar farms on Earth or on the Moon and Mars, is prohibitively expensive. This project will prototype a high-fidelity digital twin framework using NVIDIA IsaacSim to create realistic digital representations of robotic systems and their operating conditions, including varied terrains and environmental factors, allowing robots to learn and adapt in a faster, safer, and more affordable way to tackle unpredictable challenges in terrestrial and extraterrestrial applications. The Robotic Space Exploration (RoSE) Lab at Colorado School of Mines focused on the development and testing of synthetic digital twins to explore multi-physics interactions between robots and unstructured environments, with emphasis on lunar conditions such as deformable regolith, reduced gravity, and terrain-robot contact dynamics. The Industrialized Construction Innovation (ICI) team at National laboratory of the Rockies (NLR), simulated robotic apparatus and construction workflows using synthetic digital twins to inform real-world deployment, targeting application-driven use cases such as robotic construction of a scaled prototype of a photovoltaic energy infrastructure. Joint efforts between RoSE and ICI are continuing to explore how environment-scale multi-physics modeling and application-level robotic system simulation could be integrated to support robotic construction of energy infrastructure in highly unstructured environments, including scenarios relevant to the Lunar South Pole.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Organisation of Diverse Mechanisms of Secondary Ice Production among Basic Convective and Stratiform Cloud-types

This 3-year DoE-funded joint project had the over-arching aim of understanding how ice is initiated in clouds of various types. Focus was given to processes of fragmentation of pre-existing ice, which can occur in positive feedback loops (‘ice multiplication’). A basic question to address was which fragmentation processes prevail in which basic cloud-types. The approach was to use cloud models and field observations, while pioneering our own lab observations of ice initiation to break the deadlock from the past lack of lab observations. Historically, the tendency of the cloud physics community to avoid doing lab observations has allowed a vast gap in knowledge about ice initiation to persist for decades. During the first part of the project, new formulations were created to treat two overlooked types of fragmentation of ice. First, sublimational breakup of ice was treated based on a theoretical formula that we fitted to a pooled dataset of lab observations published previously in the literature. Second, a new mode of fragmentation of freezing raindrops was treated, which involves a supercooled drop being hit by a more massive ice particle. Some of the secondary droplets from the impact freeze. This work was done at Manchester University by Co-I Connolly. Then during the second part, both formulations were implemented in our ‘aerosol-cloud model’ (AC). AC has a hybrid bin/bulk microphysics scheme, and now represents four processes of SIP. The accuracy of AC was evaluated for four cases typifying four basic cloud-types: slightly cold-based stratiform cloud and cold-, warm- and very warm-based convective clouds. We discovered that the warmth of cloud-base, especially in the tropics, promotes SIP processes of raindrop-freezing fragmentation and rime-splintering, and surprisingly, sublimational breakup too. It was found that breakup in ice-ice collisions is ubiquitous. Finally, a portable laboratory chamber was constructed at Lund and deployed in northern Sweden to observe breakup in graupel-snow collisions outdoors. This was seen to be even more prolific than treated in our 2018 formulation. Papers describing results are either published or soon to be published.

54 ENVIRONMENTAL SCIENCES↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Evaluation of the Thermal and Moisture Performance of Insulating Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak heating and cooling loads of a home. Over the past 20 years, residential window attachment retrofit technologies have been developed that significantly increase the number of options available to home builders, homeowners, and utilities when considering upgrades of overall window performance. Within the interior window attachments category, honeycomb cellular shades typically have the highest R-values because of their layered or concentric designs. During the winter when the window is fully covered, however, the added insulation reduces the amount of warm indoor air that reaches the window surface, thereby lowering the temperature of the window glass and frame and increasing the potential for condensation to collect on the interior surface of the window. The degree to which this potential is realized depends on the indoor and outdoor conditions as well as the overall thermal resistance of the window and the shades. To examine the condensation buildup potential on the interior surface of the window and the conditions under which this occurs, this report describes experimental research conducted by Pacific Northwest National Laboratory in collaboration with Hunter Douglas, using a a controlled environmental test chamber at the Hunter Douglas facility in Broomfield, Colorado. The results will be used to inform the Attachments Energy Rating Council, which provides energy performance information on all rated window attachments products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Los Alamos National Laboratory Floodplain Assessment for the Technical Area 72 Outdoor Live Fire Range Safety Upgrades Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing new construction and upgrade activities in lower Sandia Canyon at Technical Area (TA) 72 at the Outdoor Live Fire Range facility at Los Alamos National Laboratory (LANL). The proposed upgrades are intended to improve range safety to help fulfill the mission requirements of maintaining a trained and qualified armed Protective Force.

54 ENVIRONMENTAL SCIENCES↗

Meta‐Analysis and Regression Modeling of the Impacts of Four Indoor Environmental Quality Metrics on Office Performance

Awareness of how buildings interact with the occupant experience—especially human performance—is becoming more prevalent, as seen by increasing interest and investment in healthy built environments. However, there is a need to synthesize the wide array of existing indoor environmental assessment and performance research in a way that can translate directly to building design and operation. Existing research in this area typically focuses on a single isolated metric and has not focused on making the results utilizable by building practitioners. The aim of this research is to investigate existing office performance literature through meta‐analyses and produce regression models for four indoor environmental quality (IEQ) metrics to support critical decision‐making for building operation and renovation. To reach this aim, a literature review was conducted to identify studies that measure the impact of changing ventilation rate, temperature, horizontal illuminance, and noise level in offices on occupant task performance. This repository of field and laboratory studies was analyzed to visualize the trends between the selected IEQ metrics and task performance. The temperature, ventilation rate, and horizontal illuminance regression models showed clear improvement potential when modifying indoor conditions toward the defined high‐performance range, while the regression model for noise level was inconclusive. The discussion notes the importance of designing holistically for all components of these IEQ categories to utilize the results, for example, good filtration on outdoor air for quantifying ventilation impact and uniform overhead lighting with low contrast for quantifying horizontal illuminance impact. The novelty of this work is in considering multiple facets of the indoor environment under a single, unified analysis schema and producing IEQ‐based performance gains that can directly inform cost‐benefit analyses of building design and renovation.

60 APPLIED LIFE SCIENCES↗

Spectral Effects on the Energy Harvesting Efficiency of Two- and Four-Terminal Tandem Photovoltaics

In this work, the effect of a varying spectral irradiance and top cell bandgap on the energy harvesting efficiency of two-terminal (2T) and four-terminal (4T) perovskite//silicon tandem solar cells under outdoor operating conditions is investigated. For the comparison, an optoelectronic model employing a 1 year outdoor data set for a 4T mechanical stacked gallium arsenide (GaAs) on crystalline silicon (Si) tandem device is first validated. Then, the verified model is used to simulate perovskite//silicon tandem devices with a varying perovskite top cell bandgap for a location in Golden, Colorado, USA. Here, a spectral binning method to efficiently reduce and improve the visualization of the 1 min-resolved environmental data while maintaining the simulation accuracy is introduced. The findings reveal that, for a device that is current matched under standard testing conditions, the annual spectral deviation reduces the energy harvesting efficiency by only 2% rel . When additional realistic losses for the 4T are taken into account, 2T devices are shown to have an energy-harvesting efficiency that is at parity or higher. Deviations in the top cell bandgap are more than 0.1 eV from current matching result in a reduced energy harvesting efficiency of more than 5% rel for the 2T tandem device.

14 SOLAR ENERGY↗

Challenges to detection: Humidity as a spur to chemical agent change

Detecting chemical agents in outdoor environments such as a battlefield is made challenging by not only the spurious signatures from background chemicals and surfaces (e.g. asphalt, dirt, concrete), but also by the chemical transformation of the actual agents. The change of CW agents to other species can be catalyzed by other chemicals present in the scene, by different substrates, as well as by local weather conditions. Some of the final environmental transformation products are known (e.g. for the G agents methylphosphonic acid), but many of the intermediate chemical states are not, nor are the rates of transformation to the other intermediates or the end products. In this study we have made preliminary optical investigations into the degradation products of a G-agent intermediate, namely methylphosphonic anhydride and its rate of conversion to the more stable methylphosphonic acid. Using infrared and Raman spectroscopies, we have found that the relative humidity (RH) greatly affects the rate of change and we report first results from these studies.

: chemical warfare agent detection, Methylphosphon↗

Machine Learning-Driven Reliability Estimation of PV Inverters Considering Alert-Ambient Variability

Weather-induced spatio-temporal degradation limits outdoor PV inverter lifetime and reliability, necessitating advanced data analysis. This study employs a top-down, data-driven approach utilizing multiple machine learning (ML) algorithms to estimate inverter reliability in a 1.4 MW PV power plant, considering factors such as irradiance, humidity, temperature, time of day, and weather conditions. An extensive alert dataset from 17 identical inverters, including alert types, propagation, and frequency, reveals significant correlations with environmental factors and inverter output power, enabling the construction of a performance reliability model. Dual-stage supervised-ML models are evaluated for accuracy, with the ‘classification-regression’ model by an artificial neural network (ANN) tested on the averaged “Alert-Ambient” dataset, which is outperformed by ‘clustering-regression’ models using random forest (RF) and K-Nearest Neighbors (KNN) on individual inverter datasets. K-means clustering applies principal component analysis to reduce dimensions, achieving improved accuracy beyond the 80% achieved by ANN on the averaged dataset. Second-stage regression estimates inverter reliability with a mean square error of 0.0195 on the averaged dataset and as low as 0.002 on individual inverter datasets using RF. Furthermore, these findings highlight the method's suitability for estimating PV inverter output reliability under ambient conditions, essential for digital twin development and related applications.

14 SOLAR ENERGY↗

Clean Indoor Air and Lower Environmental Impacts: Heat Recovery Ventilation in Cold Climates

Over half of Alaska homes are at risk of poor indoor air quality, which increases the risk of respiratory and other illnesses for people and animals. Heat recovery ventilators (HRVs) provide warm, fresh air to a building interior while minimizing energy use. They can be programmed to provide varying amounts of fresh air to ensure adequate ventilation for occupants and can be configured to filter air during wildfires or other events. In addition to improving the safety of indoor air and extending the life of a building, HRVs can improve surrounding outdoor air because they reduce the amount of fossil fuels needed to heat a building. Recent research by CCHRC has focused on lowering barriers to using HRVs in cold climates through laboratory evaluations and homeowner education. This poster will cover data on indoor air quality in Alaska, results of CCHRC research, and future research questions.

buildings↗

Managing ecosystem damage from extreme events

Large disturbances to ecosystems can severely impact the stability of a region's natural resources, habitats, and outdoor recreation. Because extreme events can be large and relatively infrequent, they test institutional capacity to support recovery and restoration. Here, when hurricanes and other large-scale disturbances like wildfires occur, much of the impacted landscape receives little to no active management. Ecosystems are often allowed to either recover or transition without much direct intervention, and successional dynamics are sometimes altered by novel invasive species, management history, or other environmental changes. Recovery and restoration are especially challenging for landscapes with highly fragmented private ownership, such as the forests of the eastern US. Acting alone, non-industrial private forest landowners have little capacity to effectively respond to unexpected forest loss and to oversee forest recovery, as the scale of actions needed after extreme events may require cooperation across ownerships or jurisdictions.

54 ENVIRONMENTAL SCIENCES↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential segregation and outdoor urban moist heat stress disparities in the United States

The combined impact of urbanization-induced warming and drying on large-scale heat stress disparities remains unknown, with multicity studies using satellite-derived land surface temperature as a proxy for these disparities. Here, using high-resolution urban-resolving numerical model simulations for 2014–2018, we find pervasive disparities in all-sky average maximum summertime air temperature and moist heat stress metrics across US cities, with higher outdoor heat stress exposure in poorer and primarily non-white census tracts. Ninety-four percent of the US urban population (228 million) live in cities where heat stress burdens the poor, with heat stress inequities between white and non-white populations strongly associated with residential segregation. Similarly, historically redlined neighborhoods show higher heat stress than their non-redlined counterparts, demonstrating how historical segregation relates to present-day environmental inequalities. Our results provide quantitative estimates of physiologically relevant heat stress disparities at the US national scale and highlight potential biases when using satellites as a proxy for these.

54 ENVIRONMENTAL SCIENCES↗

A Graphics Processing Unit (GPU) Approach to Large Eddy Simulation (LES) for Transport and Contaminant Dispersion

Recent advances in the development of large eddy simulation (LES) atmospheric models with corresponding atmospheric transport and dispersion (AT&D) modeling capabilities have made it possible to simulate short, time-averaged, single realizations of pollutant dispersion at the spatial and temporal resolution necessary for common atmospheric dispersion needs, such as designing air sampling networks, assessing pollutant sensor system performance, and characterizing the impact of airborne materials on human health. The high computational burden required to form an ensemble of single-realization dispersion solutions using an LES and coupled AT&D model has, until recently, limited its use to a few proof-of-concept studies. An example of an LES model that can meet the temporal and spatial resolution and computational requirements of these applications is the joint outdoor-indoor urban large eddy simulation (JOULES). A key enabling element within JOULES is the computationally efficient graphics processing unit (GPU)-based LES, which is on the order of 150 times faster than if the LES contaminant dispersion simulations were executed on a central processing unit (CPU) computing platform. JOULES is capable of resolving the turbulence components at a suitable scale for both open terrain and urban landscapes, e.g., owing to varying environmental conditions and a diverse building topology. In this paper, we describe the JOULES modeling system, prior efforts to validate the accuracy of its meteorological simulations, and current results from an evaluation that uses ensembles of dispersion solutions for unstable, neutral, and stable static stability conditions in an open terrain environment.

54 ENVIRONMENTAL SCIENCES↗