Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Outage detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Using artificial intelligence to detect human errors in nuclear power plants: A case in operation and maintenance

Human error (HE) is an important concern in safety-critical systems such as nuclear power plants (NPPs). HE has played a role in many accidents and outage incidents in NPPs. Despite the increased automation in NPPs, HE remains unavoidable. Hence, the need for HE detection is as important as HE prevention efforts. In NPPs, HE is rather rare. Hence, anomaly detection, a widely used machine learning technique for detecting rare anomalous instances, can be repurposed to detect potential HE. In this study, we develop an unsupervised anomaly detection technique based on generative adversarial networks (GANs) to detect anomalies in manually collected surveillance data in NPPs. More specifically, our GAN is trained to detect mismatches between automatically recorded sensor data and manually collected surveillance data, and hence, identify anomalous instances that can be attributed to HE. We test our GAN on both a real-world dataset and an external dataset obtained from a testbed, and we benchmark our results against state-of-the-art unsupervised anomaly detection algorithms, including one-class support vector machine and isolation forest. Our results show that the proposed GAN provides improved anomaly detection performance. Our study is promising for the future development of artificial intelligence based HE detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Method for Estimating Time-Series PV Production Loss From Solar Tracking Failures

Solar tracking system failures can dramatically reduce photovoltaic (PV) system energy output through suboptimal irradiance capture and self-shading loss. Detecting tracker failures is not always straightforward; unlike other common PV system failures like inverter outages and blown fuses which take portions of a system completely offline, tracker failures only partially reduce output power and can go unnoticed as a result. Additionally, tracker failures can take one of several forms, each with their own loss characteristics. Here we present two methods of detecting tracker failure events from time-series production data and a method for estimating the associated production loss. Compared with existing detection methods, the proposed power-based detection method showed 0-17% reductions in Type I error rate depending on weather conditions. Here, the loss model estimated production loss with low error (mean bias error = -2.3 %, root-mean-squared error = 6%) in a rudimentary validation.

14 SOLAR ENERGY↗

Low-cost wireless voltage & current grid monitoring

This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distribution grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.

14 SOLAR ENERGY↗

Automating Detection and Diagnosis of Faults, Failures, and Underperformance in PV Plants

The project developed hybrid physics-based and machine-learning methods for near-real-time detection of balance-of-system faults (e.g., string, combiner, and tracker outages) in utility-scale Photovoltaic plants, achieving over 50% true positive rates with under 10% false positives and significantly reducing engineering setup time. In the extended phase, the scope expanded to plant-level underperformance analysis and industry benchmarking through the SUPER.epri.com platform. SUPER standardizes data processing and performance metrics across more than 9 GWac and 120+ plants, enabling robust comparisons and insights into loss rates, inverter downtime, and capacity degradation.

14 SOLAR ENERGY↗

Model-Based Diagnosis and Prognosis of a Water Recycling System

A water recycling system (WRS) deployed at NASA Ames Research Center s Sustainability Base (an energy efficient office building that integrates some novel technologies developed for space applications) will serve as a testbed for long duration testing of next generation spacecraft water recycling systems for future human spaceflight missions. This system cleans graywater (waste water collected from sinks and showers) and recycles it into clean water. Like all engineered systems, the WRS is prone to standard degradation due to regular use, as well as other faults. Diagnostic and prognostic applications will be deployed on the WRS to ensure its safe, efficient, and correct operation. The diagnostic and prognostic results can be used to enable condition-based maintenance to avoid unplanned outages, and perhaps extend the useful life of the WRS. Diagnosis involves detecting when a fault occurs, isolating the root cause of the fault, and identifying the extent of damage. Prognosis involves predicting when the system will reach its end of life irrespective of whether an abnormal condition is present or not. In this paper, first, we develop a physics model of both nominal and faulty system behavior of the WRS. Then, we apply an integrated model-based diagnosis and prognosis framework to the simulation model of the WRS for several different fault scenarios to detect, isolate, and identify faults, and predict the end of life in each fault scenario, and present the experimental results.

Roychoudhury, Indranil↗

On-Line Monitoring to Detect Sensor and Process Degradation under Normal Operational Transients - 327

Calibration assessment of nuclear plant sensors and transmitters is currently performed through periodic maintenance actions during plant refueling outages. On-line monitoring (OLM) can be used to reduce the time and cost of this maintenance process by using empirical models to evaluate sensor calibration. The implementation of OLM can also mitigate human error associated with unnecessary maintenance on sensors operating within calibration tolerances. OLM has been studied and validated for plants under steady-state baseload operation, but the extension to load-following operation is not well-documented in the literature. Auto-associative kernel regression (AAKR) provides an error-corrected prediction of process sensor measurements for OLM through a weighted average of historic data. The current study evaluates the performance of AAKR for prediction under normal operational transients (such as expected under load-following operation). Performance of the AAKR model with two anomaly detection routines, error uncertainty limit monitoring (EULM) and sequential probability ratio test (SPRT), was evaluated for normal operation, sensor faults, and process degradation. The data used to develop and evaluate the OLM system were collected from a forced flow loop with temperature and flow sensors. Three models of well-correlated groups of sensors are trained to predict normal system behavior under planned transients. The anomaly detection routines are tested for sensor faults and process faults. The results of this experimental study suggest AAKR and an appropriate anomaly detection routine can be applied for sensor calibration and process fault detection under transient operation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Automatic Imagery Data Analysis for Proactive Computer-Based Workflow Management during Nuclear Power Plant Outages

This report is being submitted for the task “Final Report” of DOE NEUP Project 15-8121 “Automatic Imagery Data Analysis for Proactive Computer-Based Workflow Management during Nuclear Power Plant Outages.” Typical nuclear power plant (NPP) outages always involve thousands of maintenance and refueling activities and a large number of workers in limited workspaces, while having tight schedules and zero-tolerance for accidents. During an outage, thousands of workers will be working in various workspaces across the NPP. High outage costs and expensive delays (approximately 1.5 million dollars of loss per day of delay) in NPP maintenance demand tight outage schedules. In packed workspaces, an automatic system that monitors human behaviors in real-time and provides insights about current and pending schedule deviations from the plan is critical for ensuring: 1) effective collaboration among workers and worker teams from different trades; 2) less waste of time and resources due to the lack of situational awareness; and 3) proactive outage project control. The overall goal of this project is to test the hypothesis that real-time imagery-based object tracking and spatial analysis, as well as human behavior modeling of outage participants, will significantly improve the efficiency of outage control while lowering the rates of accidents and incidents. Three objectives of this project are: 1) Establish real-time object tracking and spatiotemporal analysis methods that automatically assess the productivity of field activities and detect anomalous spatiotemporal relationships among activities that cause inefficiencies and risks; 2) Establish realtime human tracking and human factor modeling methods for automatically diagnosing unexpected actions of and interactions between outage participants, those which cause inefficient collaborations between Advanced Outage Control Center (AOCC), satellite outage centers, NPP workers, and maintenance service providers; and 3) Test the proposed automated object tracking, human behavior modeling, and spatiotemporal analysis methods in outage control case studies in order to characterize the effectiveness of automated imagery-data-driven methods in proactively improving the efficiency and safety of workflows in outage coordination and risk management. Recent studies of detailed human behavior monitoring on construction sites have examined the potential of applying advanced computer vision algorithms in detecting and tracking anomalous workers (i.e., workers who do not wear hard hats or safety vests) for ensuring job site safety. Some studies of human factor studies revealed the importance of modeling detailed interactions between individuals within and across teams in better understanding the impact of human in proactive project control. Other studies in the construction domain have developed computational simulation frameworks that formalize detailed spatiotemporal interactions between tasks in order to simulate the impacts of individual tasks on the performance of workflows. While integrated analyses that combine human factor assessment, as well as image processing and simulation, are in demand for effective decision-making, limited studies have examined the potential of such integrated analyses in NPP outage control. This research project has examined an automatic outage monitoring and control system that integrates human factor analysis, computer vision techniques, and simulation methods in order to enable engineers to better understand the interactions between humans, resources, and workflows during outage processes. The project aims at providing NPP maintenance agencies insights into more efficient use of limited resources in extending the life of a nuclear plant, as well as reducing waste while ensuring sufficient generation of electricity. This study is significant for the safety of nuclear plants, sustainable electricity generation for livable communities, and cost savings for maintaining electricity infrastructures in the United States.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

Oscillation Detection Algorithm Development Summary Report and Test Plan

Small signal stability problems are one of the major threats to grid stability and reliability in California and the western U.S. power grid. An unstable oscillatory mode can cause large-amplitude oscillations and may result in system breakup and large-scale blackouts. There have been several incidents of system-wide oscillations. Of them, the most notable is the August 10, 1996 western system breakup produced as a result of undamped system-wide oscillations. There is a great need for real-time monitoring of small-signal oscillations in the system. In power systems, a small-signal oscillation is the result of poor electromechanical damping. Considerable understanding and literature have been developed on the small-signal stability problem over the past 50+ years. These studies have been mainly based on a linearized system model and eigenvalue analysis of its characteristic matrix. However, its practical feasibility is greatly limited as power system models have been found inadequate in describing real-time operating conditions. Significant efforts have been devoted to monitoring system oscillatory behaviors from real-time measurements in the past 20 years. The deployment of phasor measurement units (PMU) provides high-precision time-synchronized data needed for estimating oscillation modes. Measurement-based modal analysis, also known as ModeMeter, uses real-time phasor measure-ments to estimate system oscillation modes and their damping. Low damping indicates potential system stability issues. Oscillation alarms can be issued when the power system is lightly damped. A good oscillation alarm tool can provide time for operators to take remedial reaction and reduce the probability of a system breakup as a result of a light damping condition. Real-time oscillation monitoring requires ModeMeter algorithms to have the capability to work with various kinds of measurements: disturbance data (ringdown signals), noise probing data, and ambient data. Several measurement-based modal analysis algorithms have been developed. They include Prony analysis, Regularized Ro-bust Recursive Least Square (R3LS) algorithm, Yule-Walker algorithm, Yule-Walker Spectrum algorithm, and the N4SID algo-rithm. Each has been shown to be effective for certain situations, but not as effective for some other situations. For example, the traditional Prony analysis works well for disturbance data but not for ambient data, while Yule-Walker is designed for ambient data only. Even in an algorithm that works for both disturbance data and ambient data, such as R3LS, latency results from the time window used in the algorithm is an issue in timely estimation of oscillation modes. For ambient data, the time window needs to be longer to accumulate information for a reasonably accurate estimation; while for disturbance data, the time window can be significantly shorter so the latency in estimation can be much less. In addition, adding a known input signal such as noise probing signals can increase the knowledge of system oscillatory properties and thus improve the quality of mode estimation. System situations change over time. Disturbances can occur at any time, and probing signals can be added for a certain time period and then removed. All these observations point to the need to add intelligence to ModeMeter applications. That is, a ModeMeter needs to adaptively select different algorithms and adjust parameters for various situations. This project aims to develop systematic approaches for algorithm selection and parameter adjustment. The very first step is to detect occurrence of oscillations so the algorithm and parameters can be changed accordingly. The proposed oscillation detection approach is based on the signal-noise ratio of measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Observation of Schumann Resonances in the Earth's Ionosphere

The surface of the Earth and the lower edge of the ionosphere define a cavity in which electromagnetic waves propagate. When the cavity is excited by broadband electromagnetic sources, e.g., lightning, a resonant state can develop provided the average equatorial circumference is approximately equal to an integral number of wavelengths of the electromagnetic waves. This phenomenon, known as Schumann resonance, corresponds to electromagnetic oscillations of the surface-ionosphere cavity, and has been used extensively to investigate atmospheric electricity. Using measurements from the Communications/Navigation Outage Forecasting System (C/NOFS) satellite, we report, for the first time, Schumann resonance signatures detected well beyond the upper boundary of the cavity. These results offer new means for investigating atmospheric electricity, tropospheric-ionospheric coupling mechanisms related to lightning activity, and wave propagation in the ionosphere. The detection of Schumann resonances in the ionosphere calls for revisions to the existing models of extremely low frequency wave propagation in the surface-ionosphere cavity. Additionally, these measurements suggest new remote sensing capabilities for investigating atmospheric electricity at other planets.

Simoes, Fernando↗

Holistic Measurement Driven Resilience: Combining Operational Fault and Failure Measurements and Fault Injection for Quantifying Fault Detection, Propagation and Impact. Final report

For HPC systems to date, application resilience to faults and failures has been accomplished by the brute- force method of checkpoint/restart, which allows an application to make forward progress in the face of system and application faults, errors, and failures independent of root cause or end result. It has remained the primary resilience mechanism because we lack a way to identify faults and anticipate consequences early enough to take meaningful mitigating action. However, checkpoint/restart implementations put a tremendous burden on system resources and on the applications themselves and is becoming less feasible at scale. Because we have not yet operated at scales at which checkpoint/restart fails to provide forward progress, despite increasing costs, vendors have had little motivation to provide the instrumentation necessary for early identification of faults and failures. However, as we move from petascale to exascale, component mean time to failure (MTTF) will render the existing techniques ineffectual and/or too expensive. Furthermore, fault recovery mechanisms such as failover and/or error correction introduce performance inconsistency. Instrumentation allowing early indication of problems and tools to enable use of such information by systems, operating systems, and applications offer an alternative, more scalable and less costly solution. In the HMDR project, we built on our experience and expertise developed and accumulated over years of research on design, monitoring, measurement, and assessment of resilient computing systems. Analysis of field data on the current and past generations of extreme-scale systems revealed several challenges that, if not addressed in increasingly larger and more complex systems, may hinder the effectiveness of future exascale computing systems. Specifically, i) file systems and interconnects in current-generation large-scale systems already operate at the margins of resiliency, including consistent performance, and may not scale to larger deployments; ii) automated, software-based failover mechanisms are frequently inadequate and can introduce wider failures, such that failures during recovery may lead to system/application failures, including system-wide outages; and iii) silent data corruption represents a critical fault mode and will require efficient detection mechanisms if next-generation applications are to take full advantage of exascale hardware. To address the above challenges, we assembled a team of world-renowned experts in resilient extreme- scale computing from the University of Illinois (Electrical and Computer Engineering, Computer Science, and NCSA), SNL, LANL, NERSC, and Cray. Our team includes representatives from centers that house many of the largest HPC resources in the world, both today and over the coming years. The team has a unique track record of research in i) system and application failure characterization based on the analysis of field data, ii) data-driven design of fault/error detection mechanisms, and iii) experimental characterization of system/application resiliency. The team includes system owners/operators who provide continuous data collection and access and ensure installation of appropriate analysis tools.

97 MATHEMATICS AND COMPUTING↗

NetMOD version 1.0 user's manual

NetMOD (Network Monitoring for Optimal Detection) is a Java-based software package for conducting simulation of seismic networks. Specifically, NetMOD simulates the detection capabilities of seismic monitoring networks. Network simulations have long been used to study network resilience to station outages and to determine where additional stations are needed to reduce monitoring thresholds. NetMOD makes use of geophysical models to determine the source characteristics, signal attenuation along the path between the source and station, and the performance and noise properties of the station. These geophysical models are combined to simulate the relative amplitudes of signal and noise that are observed at each of the stations. From these signal-to-noise ratios (SNR), the probability of detection can be computed given a detection threshold. This manual describes how to configure and operate NetMOD to perform seismic detection simulations. In addition, NetMOD is distributed with a simulation dataset for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) International Monitoring System (IMS) seismic network for the purpose of demonstrating NetMOD's capabilities and providing user training. The tutorial sections of this manual use this dataset when describing how to perform the steps involved when running a simulation.

58 GEOSCIENCES↗

Software Contribution to the L-CAPE project

The L-CAPE project utilizes asynchronous data from thousands of Linear Accelerator devices and applies data science techniques to detect anomaly of accelerator failure before the incident, as well as automatic labels of accelerator outages. The author describes her contribution progress for the L-CAPE project this summer, as well as suggestions for future interns working on the project.

Tang, Jasmine↗

Overcoming Communications Outages in Inverter Downtime Analysis: Preprint

Inverters are often reported to be the highest-impact failure point in PV systems. This importance is belied by the simplistic assumptions about inverter downtime losses used in industrial energy modeling. Energy models often assume the extent of inverter-related losses is limited to 1% of annual production from scheduled inverter preventative maintenance. In reality, inverter-related production losses are much more variable, although data from large-scale surveys of fielded systems are rare. Here we present a method of detecting inverter downtime events and estimating the associated lost production using inverter- and meter-level power data. Because communications outages are of similar frequency to true production outages, the method pays particular attention to distinguishing communications outages from true production outages. The results of applying the method at fleet-scale are presented and discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Demonstration of a Novel Synchrophasor-based Situational Awareness System: Wide Area Power System Visualization, On-line Event Replay and Early Warning of Grid Problems

Since the large North Eastern power system blackout on August 14, 2003, U.S. electric utilities have spent lot of effort on preventing power system cascading outages. Two of the main causes of the August 14, 2003 blackout were inadequate situational awareness and inadequate operator training In addition to the enhancements of the infrastructure of the interconnected power systems, more research and development of advanced power system applications are required for improving the wide-area security monitoring, operation and planning in order to prevent large- scale cascading outages of interconnected power systems. It is critically important for improving the wide-area situation awareness of the operators or operational engineers and regional reliability coordinators of large interconnected systems. With the installation of large number of phasor measurement units (PMU) and the related communication infrastructure, it will be possible to improve the operators’ situation awareness and to quickly identify the sequence of events during a large system disturbance for the post-event analysis using the real-time or historical synchrophasor data. The purpose of this project was to develop and demonstrate a novel synchrophasor-based comprehensive situational awareness system for control centers of power transmission systems. The developed system named WASA (Wide Area Situation Awareness) is intended to improve situational awareness at control centers of the power system operators and regional reliability coordinators. It consists of following main software modules: • Wide-area visualizations of real-time frequency, voltage, and phase angle measurements and their contour displays for security monitoring. • Online detection and location of a major event (location, time, size, and type, such as generator or line outage). • Near-real-time event replay (in seconds) after a major event occurs. • Early warning of potential wide-area stability problems. The system has been deployed and demonstrated at the Tennessee Valley Authority (TVA) and ISO New England system using real-time synchrophasor data from openPDC. Apart from the software product, the outcome of this project consists of a set of technical reports and papers describing the mathematical foundations and computational approaches of different tools and modules, implementation issues and considerations, lessons learned, and the results of lidation processes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Traveling Wave Signatures in Medium-Voltage Distribution Systems for Fault Detection and Location

Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

14 SOLAR ENERGY↗

Cybersecurity Anomaly Detection in SCADA-Assisted OT Networks Using Ensemble-Based State Prediction Model

The cybersecurity threats of power system gradually grow due to the increased sophisticated interactions between Information Technology (IT) and Operational Technology (OT) networks. False data injection attack (FDIA) that aims to compromise the Supervisory Control and Data Acquisition (SCADA) measurement and disturb the system operation is one of such cyber threats. Such attacks can potentially lead to significant operational issues at the control centers and substations, and hence, result in severe physical consequences. To avoid catastrophic failure across the power grid resulting from these attacks, it is essential to arm the OT network with real-time vulnerability assessment tools. To this end, this paper outlines various drawbacks of the Purdue architecture model to defend against cyberattacks in the OT network. Furthermore, a novel ensemble-based state prediction model is proposed to detect cybersecurity anomalies in SCADA assisted OT networks. The proposed model uses control center level generation and load forecasts, scheduled, and forced outages, power flow solutions, and the substation level historical data. The hypothesis of the proposed scheme relies on the fact that additional control center and substation data can hardly be accessed and compromised by attackers. One of the vital features of the proposed scheme is an hour-ahead prediction of the operational feasibility of the SCADA measurement range at the control center and substation in real time helps in detecting anomalies in measurements across both substation and the control center.

24 POWER TRANSMISSION AND DISTRIBUTION↗