Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Orthopedics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Rapid Diagnosis of an Ulnar Fracture with Portable Hand-Held Ultrasound

Orthopedic fractures are a common injury in operational activities, injuries that often occur in isolated or hostile environments. Clinical ultrasound devices have become more user friendly and lighter allowing them to be easily transported with forward medical teams. The bone-soft tissue interface has a very large acoustic impedance, with a high reflectance that can be used to visualize breaks in contour including fractures. Herein reported is a case of an ulnar fracture that was quickly visualized in the early phase of a multi-system trauma resuscitation with a hand-held ultrasound device. The implications for operational medicine are discussed.

Kirkpatrick, Andrew W.↗

Mineralized three-dimensional bone constructs

The present disclosure provides ex vivo-derived mineralized three-dimensional bone constructs. The bone constructs are obtained by culturing osteoblasts and osteoclast precursors under randomized gravity vector conditions. Preferably, the randomized gravity vector conditions are obtained using a low shear stress rotating bioreactor, such as a High Aspect Ratio Vessel (HARV) culture system. The bone constructs of the disclosure have utility in physiological studies of bone formation and bone function, in drug discovery, and in orthopedics.

Clarke, Mark S. F.↗

Aerogel Use as a Skin Protective Liner In Space Suits and Prosthetic Limbs Project

Existing materials for prosthetic liners tend to be thick and airtight, causing perspiration to accumulate inside the liner and potentially causing infection and injury. The purpose of this project was to examine the suitability of aerogel for prosthetic liner applications for use in space suits and orthopedics. Three tests were performed on several types of aerogel to assess the properties of each material, and our initial findings demonstrated that these materrials would be excellent candidates for liner applications for prosthetics and space suits. The project is currently on hold until additional funding is obtained for application testing at the VH Hospitals in Tampa

Technology Portfolio System↗

Injury Surveillance Among NASA Astronauts Using the Barell Injury Diagnosis Matrix

Astronauts perform physically demanding tasks and risk incurring musculoskeletal injuries during both groundbased training and missions. Increased injury rates throughout the history of the U.S. space program have been attributed to numerous factors, including an aging astronaut corps, increased Weightless Environment Training Facility (WETF) and Neutral Buoyancy Laboratory (NBL) training to construct the International Space Station, and improved clinical operations that promote injury prevention and reporting. With NASA program changes through the years (including retirement of the Shuttle program) and an improved training environment (including a new astronaut gym), there is no surveillance program to systematically track injury rates. A limited number of research projects have been conducted over the past 20 years to evaluate musculoskeletal injuries: (1) to evaluate orthopedic injuries from 1987 to 1995, (2) to describe upper extremity injuries, (3) to evaluate EVA spacesuit training related injuries, and (4) to evaluate in-flight musculoskeletal injuries. Nevertheless, there has been no consistently performed comprehensive assessment of musculoskeletal injuries among astronauts. The Barell Injury Diagnosis Matrix was introduced at the 2001 meeting of the International Collaborative Effort (ICE) on Injury Statistics. The Matrix proposes a standardized method of classifying body region by nature of injury. Diagnoses are coded using the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) coding system. The purpose of this study is to assess the usefulness and complexity of the Barell Injury Diagnosis Matrix to classify and track musculoskeletal injuries among NASA astronauts.

Murray, J. D.↗

Mineralized Three-Dimensional Bone Constructs

The present disclosure provides ex vivo-derived mineralized three-dimensional bone constructs. The bone constructs are obtained by culturing osteoblasts and osteoclast precursors under randomized gravity vector conditions. Preferably, the randomized gravity vector conditions are obtained using a low shear stress rotating bioreactor, such as a High Aspect Ratio Vessel (HARV) culture system. The bone constructs of the disclosure have utility in physiological studies of bone formation and bone function, in drug discovery, and in orthopedics.

Clarke, Mark S. F.↗

Review of NASA's Evidence Reports on Human Health Risks

NASA has requested a study from the Institute of Medicine (IOM) to provide an independent review of more than 30 evidence reports on human health risks for long duration and exploration spaceflight. The evidence reports, which are publicly available, are categorized into five broad categories: (1) behavioral health and performance; (2) human health countermeasures (with a focus on bone metabolism and orthopedics, nutrition, immunology, and cardiac and pulmonary physiology); (3) radiation; (4) human factors issues; and (5) exploration medical capabilities. The reports are revised on an ongoing basis to incorporate new scientific information. In conducting this study, an IOM ad hoc committee will build on the 2008 IOM report Review of NASA's Human Research Program Evidence Books. That report provided an assessment of the process used for developing the evidence reports and provided an initial review of the evidence reports that had been completed at that time. Each year, NASA staff will identify a set of evidence reports for committee review. Over the course of the study all evidence reports will be reviewed. The committee will hold an annual scientific workshop to receive input on the evidence reports it is reviewing that year and an update on the recent literature. The committee will issue an annual letter report that addresses the following questions relevant to each evidence report: 1. Does the evidence report provide sufficient evidence, as well as sufficient risk context, that the risk is of concern for long-term space missions? 2. Does the evidence report make the case for the research gaps presented? 3. Are there any additional gaps in knowledge or areas of fundamental research that should be considered to enhance the basic understanding of this specific risk? 4. Does the evidence report address relevant interactions among risks? 5. Is input from additional disciplines needed? 6. Is the breadth of the cited literature sufficient? 7. What is the overall readability and quality? 8. Is the expertise of the authors sufficient to fully cover the scope of the given risk? 9. Has the evidence report addressed previous recommendations made by the IOM in the 2008 letter report?

Scott-Conner, Carol E. H.↗

Parallels in Communication and Navigation Technology and Natural Phenomenon

The premise is more than art imitates life, or technology imitates nature it is a nascent step to see how we might be unwittingly inspired and influenced. An example that might immediately come to mind is a starling murmuration (a phenomenon called scale-free correlation) and Intels recent Coachella music festival drone performance. Superconductivity is a macroscopic manifestation of a quantum phenomenon - choreographed electrons (i.e. an electron murmuration) that enable astonishing devices. There is indeed an intimate connectedness between biology and electromagnetism. Our brains are complex neural circuits generating magnetic fields with a magnitude around 100 femtoTesla (roughly one billion times weaker than a typical magnet used to tack notes to a refrigerator door). Migratory birds navigate by orienteering with respect to the Earth's magnetic field. Electromagnetic field therapy is used in orthopedics to aid in bone repair. The electric eel generates a large electric field for self-defense. Sharks apparently detect extremely weak electric fields for finding prey. And so on. There are similarities between the way a field of wheat responds to a breeze and the natural restoring forces of a semiconductor crystal. And waves in a slowly moving river can lap backwards against a peninsular shoreline mimicking a diffraction effect. Getting back to the introductory sentence and mysterious links over cosmic distances, in August 2016, China launched the Quantum Experiments at Space Scale (QUESS) satellite. The technology is based on a non-linear crystal that produces pairs of entangled photons whose attributes apparently remain entwined regardless of how far apart they are separated. This paper will, no doubt superficially, attempt to enumerate and examine these types of connections and parallelisms.

Romanofsky, Robert↗

Latex–collagen membrane: an alternative treatment for tibial bone defects

Due to the difficulty of consolidation, the risk of fractures, and the high cost of therapy, the orthopedic field views the restoration of bony defects or post-traumatic diseases as a significant issue. In recent years, efforts have been made toward guided bone regeneration as a viable solution. In this study, natural rubber latex (NRL) and latex–collagen (NRL-COL) membranes were developed and characterized, and their effects on bone regeneration in rat tibial lesions were assessed. According to the physicochemical findings, the hydrolyzed COL was effectively incorporated into the NRL membrane to produce a more robust membrane (348% increase in stress) and showed good biocompatibility for human dermal fibroblast cells and in hemolytic activity assay. According to bone analysis using computed microtomography, a substantial difference in bone volume (BV) was found among NRL, control (CONT), and NRL-COL. NRL-COL exhibited the greatest value for the bone volume/total volume ratio (BV/TV). The presence of NRL and COL was significant for the analysis of BV and BV/TV, respectively. All the experimental groups demonstrated a higher bone quality and fracture resistance, as shown by the mechanical properties of the bone. In the COL group, both neoformation of bone and total collagen levels were greater, indicating that treated defects had been closed and mature bone cells were present. Due to its angiogenic properties and the low cost of NRL membrane production, the NRL-COL membrane could be a good substitute for upcoming bone regeneration applications.

Marcela Britto de Paiva↗

Assessing the Added Value of Miniature X-Ray in the Setting of Portable Ultrasound in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in low-Earth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

J G Steller↗

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

A comparative study on the physicochemical characteristics of nanoparticles released in vivo from CoCrMo tapers and cement–stem interfaces of total hip replacements

The good biocompatibility and corrosion resistance of the bulk CoCrMo alloy has resulted in it being used in the manufacture of implants and load bearing medical devices. These devices, however, can release wear and corrosion products which differ from the composition of the bulk CoCrMo alloy. The physicochemical characteristics of the particles and the associated in vivo reactivity are dictated by the wear mechanisms and electrochemical conditions at the sites of material loss. Debris released from CoCrMo hip bearings, taper junctions, or cement–stem interfaces can, therefore, have different chemical and morphological characteristics, which provide them with different in vivo toxicities. Here, we propose to assess and compare the characteristics of the particles released in vivo from CoCrMo tapers and cement–stem interfaces which have received less attention compared to debris originating from the hip bearings. The study uses state–of–art characterization techniques to provide a detailed understanding of the size, morphology, composition, and chemistry of the particles liberated from the wear and corrosion flakes from revised hip replacements, with an enzymatic treatment. The phase analyses identified Cr 2 O 3 nanoparticles released from tapers and cement–stem interfaces, whose composition did not vary with origin or particle morphology. The size distributions showed significantly smaller particles were released from the stems, compared to the particles originating from the corresponding tapers. Furthermore, the investigation demonstrates that the tribocorrosive processes occurring at the taper and stem interfaces both result in Cr 2 O 3 nanoparticle formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intramedullary Unicortical Button and All-Suture Anchors Provide Similar Maximum Strength for Onlay Distal Biceps Tendon Repair

To evaluate the biomechanical profile of onlay distal biceps repair with an intramedullary unicortical button versus all-suture anchors under cyclic loading and maximal load to failure. Twenty paired fresh-frozen human cadaveric elbows were randomized to onlay distal biceps repair with either a single intramedullary button or with two 1.35-mm all-suture anchors. A 1.3-mm high tensile strength tape was used in a Krackow stitch to suture the tendons in both groups. Specimens and repair constructs were loaded for 3,000 cycles and then loaded to failure. Maximum load to failure, mode of failure, and construct elongation were recorded. Mean (± standard deviation) maximum load to failure for the unicortical intramedullary button and all-suture anchor repairs were 503.23 ± 141.77 N and 537.33 ± 262.13 N (P = .696), respectively. Mean maximum displacement after 3,000 cycles (± standard deviation) was 4.17 ± 2.05 mm in the button group and 2.06 ± 1.05 mm in the suture anchor group (P = .014). Mode of failure in the button group was suture tape rupture in 7 specimens, failure at the tendon–suture interface in 2 specimens, and button pullout in 1 specimen. Anchor pullout was the mode of failure in all suture anchor specimens. There were no tendon ruptures or radial tuberosity fractures in either group. In conclusion, this study demonstrates that onlay distal biceps repair with 2 all-suture anchors has similar maximum strength to repair with an intramedullary button and that both are viable options for fixation.

60 APPLIED LIFE SCIENCES↗

Differences in Outcomes between Patellar Dislocations Managed in Emergent versus Non-Emergent Care Settings

Abstract Patellar dislocations occur at a much higher rate in military than civilian populations. Past population-level studies have shown that surgical management is as good as or superior to conservative care and may reduce future reoccurrences. Although in acute cases and in civilian clinics, patellar dislocations are usually managed first in an emergent care setting, previous work suggests this can lead to increased costs. This study compared differences in downstream care type and intensity of services based on whether initial care occurred in emergent or non-emergent care settings. In our sample of 1,523 Military Health System (MHS) beneficiaries with patellar dislocation and 2-year follow-up, we found non-significant differences in costs, intensity of services, and rates of surgical repair regardless of whether the patient was initially seen in an emergent versus non-emergent care setting. Although we found significant increases in the use of imaging, patellar dislocation-related medical visits, and frequency of closed treatment approaches in emergent care settings, these values were very small and likely not clinically significant. These findings, which included all the patellar dislocations reported across the entire MHS in a 24-month period, suggest that neither emergent nor non-emergent care settings are likely to influence the long-term care received by the individual.

Orthopedics↗

A Population-Level Summary of Health Care Utilization for the Management of Patellar Tendinopathy in the Military Health System

Abstract Patellar tendinopathy (PT) is a common nontraumatic orthopaedic disorder of the knee suffered by many service members. Understanding the make-up of usual care for PT at the system level can better frame current clinical gaps and areas that need improvement. Exercise therapy is recommended as a core treatment for PT, but it is unclear how often it is used as a part of usual care for PT within the Military Health System (MHS). The purpose of the study was to identify interventions used in the management of PT and the timing of these interventions. A secondary purpose was to determine if exercise therapy use was associated with reduced recurrence of knee pain. In total, 4,719 individuals aged 17 to 50 years in the MHS diagnosed with PT between 2010 and 2011 were included. Pharmacological and nonpharmacological interventions, visits to specialty providers, and imaging services were captured. Descriptive statistics were used to report the findings. Interventions were further categorized as being part of initial care (within the first 7 days), the initial episode of care (within the first 60 days), or the 2-year time period after diagnosis. Linear regression assessed the relationship between the number of exercise therapy visits in the initial episode of care and recurrences of knee pain. In total, 50.6% of this cohort had no more than one medical visit total for PT. Exercise therapy (18.2%) and nonsteroidal anti-inflammatory drugs (4.3%) were the two most used interventions in the initial episode of care. Radiographs were ordered for 23.1% of the cohort in the initial episode of care. The number of exercise therapy visits a patient received during the initial episode of care was not associated with recurrences of knee pain. Half of the individuals received no further care beyond an initial visit for the diagnosis of PT. Exercise therapy was the most common intervention used during the initial episode of care, but exercise therapy did not influence the recurrence of knee pain.

Orthopedics↗

Hooks versus Pedicle Screws at the Upper Instrumented Level: An In Vitro Biomechanical Comparison

Study Design. Controlled laboratory study Objective. To compare motions at the upper instrumented vertebra (UIV) and supra-adjacent level (UIV+1) between two fixation techniques in thoracic posterior spinal fusion (PSF) constructs. We hypothesized there would be greater motion at UIV+1 after cyclic loading across all constructs and bilateral pedicle screws (BPS) with posterior ligamentous compromise would demonstrate the greatest UIV+1 range of motion (ROM). Summary of Background Data. Proximal junctional kyphosis (PJK) is a well-recognized complication following long thoraco-lumbar PSF, however its mechanism is poorly understood. Methods. Twenty-seven thoracic functional spine units (FSU) were randomly divided into three UIV fixation groups (n=9): (1) BPS, (2) bilateral transverse process hooks (TPH), and (3) BPS with compromise of the posterior elements between UIV and UIV+1 (BPS-C). Specimens were tested on a servohydraulic materials testing system in native state, following instrumentation, and after cyclic loading. FSUs were loaded in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Results. After cyclic testing, the TPH group had a mean 29.4% increase in FE ROM at UIV+1 versus 76.6% in the BPS group ( P <0.05). The BPS-C group showed an increased FE of 49.9% and 62.19% with sectioning of the facet joints and interspinous ligament respectively prior to cyclic testing. Conclusion. Bilateral pedicle screws at the UIV led to greater motion at UIV+1 compared to bilateral TPH after cyclic loading. This is likely due to the increased rigidity of BPS compared to TPH leading to a “softer” transition between the TPH construct and native anatomy at the supra-adjacent level. Facet capsule compromise led to a 49.9% increase in UIV+1 motion, underscoring the importance of preserving the posterior ligamentous complex. Clinical studies that account for fusion rates are warranted to determine if constructs with a “soft transition” result in less PJK in vivo.

Neurosciences & Neurology↗

Biomechanical Analysis of Multilevel Posterior Cervical Spinal Fusion Constructs

Study Design: Controlled Laboratory Study Objective: To compare multilevel posterior cervical fusion (PCF) constructs stopping at C7, T1, and T2 under cyclic load to determine the range of motion (ROM) between the lowest instrumented level and lowest instrumented-adjacent level (LIV-1). Summary of Background Data: PCF is a mainstay of treatment for various cervical spine conditions. The transition between the flexible cervical spine and rigid thoracic spine can lead to construct failure at the cervicothoracic junction. There is little evidence to determine the most appropriate level at which to stop a multilevel PCF. Methods: Fifteen human cadaveric cervicothoracic spines were randomly assigned to 1 of 3 treatment groups: PCF stopping at C7, T1, or T2. Specimens were tested in their native state, following a simulated PCF, and after cyclic loading. Specimens were loaded in flexion-extension), lateral bending, and axial rotation. Three-dimensional kinematics were recorded to evaluate ROM. Results: The C7 group had greater flexion-extension motion than the T1 and T2 groups following instrumentation (10.17±0.83 degree vs. 2.77±1.66 degree and 1.06±0.55 degree, P <0.001), and after cyclic loading (10.42±2.30 degree vs. 2.47±0.64 degree and 1.99±1.23 degree, P <0.001). There was no significant difference between the T1 and T2 groups. The C7 group had greater lateral bending ROM than both thoracic groups after instrumentation (8.81±3.44 degree vs. 3.51±2.52 degree, P =0.013 and 1.99±1.99 degree, P =0.003) and after cyclic loading. The C7 group had greater axial rotation motion than the thoracic groups (4.46±2.27 degree vs. 1.26±0.69 degree, P =0.010; and 0.73±0.74 degree, P =0.003) following cyclic loading. Conclusion: Motion at the cervicothoracic junction is significantly greater when a multilevel PCF stops at C7 rather than T1 or T2. This is likely attributable to the transition from a flexible cervical spine to a rigid thoracic spine. Although this does not account for in vivo fusion, surgeons should consider extending multilevel PCF constructs to T1 when feasible. Level of Evidence: Not applicable.

Neurosciences & Neurology↗