Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Optically Addressable Light Valve Based on a GaN:Mn Photoconductor

Semi-insulating manganese-doped gallium nitride (GaN:Mn) layers epitaxially grown on unintentionally doped GaN substrates were used as photoconductors in optically addressable light valves (OALVs) to withstand higher operational laser fluences compared to current state-of-the-art OALVs where bismuth silicon oxide (BSO; Bi 12 SiO 20 ) layers are used as photoconductors. GaN:Mn promises to be an exciting material for optoelectronic operations due to its large laser fluence handling capability and photoresponsivity near the band edge. The laser damage thresholds for the semi-insulating epitaxial GaN:Mn layer and the n-type substrate layer were measured to be 2.4 and 4.2 J/cm 2 , respectively. These are 6–10 times higher than that of BSO (0.4 J/cm 2 ). These measurements were performed by exposing ~200 sites on the samples to increasing fluence levels from a Gaussian pulsed Nd:YAG laser system (1064 nm) operating at a 5 Hz repetition rate with a 3 ns pulse width. Photoresponsivity of the GaN:Mn material was investigated at discrete wavelengths of 447, 405, and 380 nm. Further, the peak photoresponsivity was observed under an illumination wavelength of 380 nm and is attributed to stronger absorption. The OALV was fabricated by attaching a 110-μm-thick GaN:Mn layer grown on a 280-μm-thick n-GaN layer to a 3-mm-thick BK7 optical window. A twisted nematic E7 liquid crystal was introduced to the 5 μm gap between the two components. Transmission levels of >90% were achieved for the fabricated OALVs for a peak voltage of 40 V, constrained by transmission “bleed-through”.

36 MATERIALS SCIENCE↗

Overview on Shielding Analyses for the VENUS Instrument at SNS

VENUS, a world‐class versatile neutron imaging instrument, is under construction and is expected to be completed and ready to start commissioning in 2023. The range of cold to epithermal neutrons at SNS will give users of VENUS access to novel imaging methods, as well as to significantly improved existing methods. The instrument is being built on beam line 10 at Spallation Neutron Source (SNS) First Target Station (FTS) facing a decoupled poisoned hydrogen moderator. Instrument design, which includes optics, Front-End components and instrument enclosure components and shape started over 10 years ago and during this time had significant changes. All changes were supported by neutronics analyses to provide adequate shielding for both Front-End and instrument enclosure.Final optics design will provide the field of view (FOV) at the detector position (where the image is formed) to be as high as 0.20 by 0.20 m. Both the beam, which contains a large fraction of high-energy neutrons, and the desire for a large footprint on the detector are challenges for shielding design and budget, because the driving cost for the instrument is the beam line and enclosure shielding. For cost reason VENUS baseline design is optimized with respect to both the instrument cave footprint and its wall thickness, and Front-End shielding is tailored along the beam. Analyses are performed with the Monte Carlo particle transport code MCNPX version 2.7.0 to make choices on materials, thicknesses and configurations of the shielding. Numerous calculations are performed to meet space and coast constrain and to satisfy instrument physics needs and to comply with radiation protection requirements.

Gallmeier, Franz X.↗

Free space Thomson scattering to study high energy density shocks

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

47 OTHER INSTRUMENTATION↗

High-Density Implosions on OMEGA and the National Ignition Facility (NIF) (Final FY23 report for the subcontract B656484 (formerly B640112))

This final FY23 report for the subcontract B656484 (formerly B640112) “High-Density Implosions on Omega and the National Ignition Facility (NIF)” summarizes MIT’s support of LLNL experiments at OMEGA and the NIF with nuclear diagnostics, platforms and analysis, and of training PhD students. Overall, the tasks identified as Statement-Of-Work (SOW) items for FY23 were accomplished.

42 ENGINEERING↗

Secondary scintillation properties of multi-layer THGEMs operated in low-pressure CF 4 and Ar/5%Xe

We present a measurement of the secondary scintillation yield produced by two-layer Thick Gas Electron Multipliers (M-THGEMs) in pure Tetrafluoromethane (CF 4 ) gas and in Ar mixed with 5% Xe in low-pressures down to 20 Torr. The detector was irradiated with 5.49 MeV alpha particles from a low-rate 241-Am source. The secondary scintillation light generated during the gas avalanche process was read out by a Hamamatsu photomultiplier tube (model R8520-406), sensitive to a broad wavelength range (160–650 nm). The avalanche charge was collected on the bottom electrode of M-THGEM and correlated to the scintillation light on an event-by-event basis. We observed that, for both gas types, the value of the photon to electron production ratio (0.4 ph/el in CF 4 and 0.1 ph/el in Ar/5%Xe) increases with the thickness of the M-THGEM electrodes and varies significantly with the pressure, being higher at lower values. The decrease in electroluminescence yield at higher pressures is much more pronounced in the Ar/Xe mixture. In addition, because of a larger gas avalanche volume, the electroluminescence light yield is larger in thicker M-THGEM structures. Presented results are particularly useful for designing the next generation of Optical-readout Time Projection Chambers (O-TPCs) operated at low-pressure CF 4 ; applications include experimental nuclear physics with rare isotope beams, dark matter detection with directional sensitivity and observation of the Migdal effect in a low-pressure Optical TPC.

47 OTHER INSTRUMENTATION↗

Raman Spectroscopy to Detect and Measure NOW Pheromones ("Orchard in a box")

Insect sex pheromones are chemical compounds that insects release to attract mates over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage. How mating disruption works is not fully established and likely varies across products and target species. For instance, it is not well understood how synthetic pheromones compete with natural pheromones and, in the case of monitoring, how efficaciously the insect follows the diffusing plumes, especially across large blocks and at plot borders. Whether an aerosol puffer is used for mating disruption or lure for monitoring population development, we currently lack the ability to fully understand how these synthetic pheromone compounds diffuse away from their point-source of emission – and subsequently how this might affect the efficacy of mating disruption and/or the accuracy of monitoring efforts. In response to these unknowns, Raman spectroscopy may offer a way to detect synthetic pheromone because of its analytical properties and recent technological advancements. In combination with nanostructured probes, RS has demonstrated the capability to detect volatiles at extremely low concentrations. We proposed to evaluate the use of Raman for the detection of synthetic and natural NOW pheromones and, were that to be successful, use this tool in subsequent years to measure pheromone diffusion in orchards.

47 OTHER INSTRUMENTATION↗

Science & Technology Review: April/May 2026 R&D 100 Winners Issue

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world. Each year, the R&D 100 Awards recognize the top 100 innovations from a pool of international entries. Technologies developed at Lawrence Livermore earned four 2025 R&D 100 Awards, raising the Laboratory’s total to 186. A series of articles beginning on p. 4 describes each winning innovation: monolithic telescopes, the flexible imaging diffraction diagnostic for laser experiments, the in-air drop encapsulation apparatus, and the metaoptics-enabled large-scale 3D nanolithography platform.

36 MATERIALS SCIENCE↗

Mid-infrared trace detection with parts-per-quadrillion quantitation accuracy: Expanding frontiers of radiocarbon sensing

Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump–probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ( 14 CO 2 ) molecules in room-temperature CO 2 samples, with 1.4 parts-per-quadrillion (ppq, 10 − 15 ) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with 14 C/C up to ∼ 1.5 × natural abundance ( ∼ 1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO 2 isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for 14 CO 2 benefits a wide range of scientific fields that utilize 14 C for dating and isotope tracing, most notably atmospheric 14 CO 2 monitoring to track CO 2 emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCExAO/MEC and CHARIS Discovery of a Low-mass, 6 au Separation Companion to HIP 109427 Using Stochastic Speckle Discrimination and High-contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the Microwave Kinetic Inductance Detector Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star point spread function (PSF) subtraction yield 1.1–2.4 μm spectra. MEC reveals the companion in Y and J band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up L {sub p} photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4–M5.5, 3000–3200 K, and log{sub 10}(L/L{sub ⊙})=−2.28{sub −0.04}{sup +0.04}, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia–Hipparcos absolute astrometry of the primary favor a semimajor axis of 6.55{sup +3.0} {sub −0.48} au, an eccentricity of 0.54{sub −0.15}{sup +0.28}, an inclination of 66.7{sub −14}{sup +8.5} degrees, and a dynamical mass of 0.280{sub −0.059}{sup +0.18} M {sub ⊙}. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely used postprocessing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Linac Extension Area at the Advanced Photon Source

The Linac Extension Area has been developed into a beamline area for testing accelerator components and techniques. Beginning commissioning activities in February 2023, we have delivered the first electron beam to the Linac Extension Area at the Advanced Photon Source at 425 MeV. In the present work, we summarise the principal accelerator components and review safety controls of the Linac Extension Area.

47 OTHER INSTRUMENTATION↗