Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Summary of AXAF calibration requirements

The following summarizes requirements on the High Resolution Mirror Assembly (HRMA) and HRMA/SI calibration. The lists of calibration measurements assume that the HRMA meets the CTT requirement that the XRCF test environment shall have not more than a 10 percent effect on the encircled energy in 1 arcsec and that it can be calibrated to 1 percent. This implies that the offloading scheme has been implemented in the HRMA. It should be remembered that there are additional calibrations needed for: aspect system; tracking; gyros; other parts of the PCAS; spacecraft timing and checks on timing accuracy for all SIs after integration in the spacecraft; ficucial lights and periscope; alignments; optical metrology data: lengths and diameters with errors on mirror elements and optical interferometer data on surface figure; and throughput and imaging stability test: an end-to-end test that can be used after the XRCF to verify that the x-ray throughput and imaging quality have not been degraded. The tables presented give a summary of the integration times for HRMA and HRMA/SI calibration.

Kellogg, E.↗

Deterministic Polishing of Replicating Grazing-Incidence Mandrels

In an effort to manufacture high-angular-resolution, grazing-incidence, x-ray optics, Marshall Space Flight Center (MSFC) is taking measures to improve its electroformed replicated optics. A key development is the use of computer-numerical control (CNC) polishing to deterministically improve the surface of electroless nickel mandrels used to replicate grazing- incidence optics. Metrology, control software and polishing parameters must function together seamlessly to reach the specifications required to replicate sub-arcsecond optics. Each change in polishing parameters effects the wear pattern of the polishing head. Using Richardson-Lucy deconvolution, the controller software fits the wear pattern to metrology data to calculate the changing feedrates across the mandrel. Here we present an overview of our process, and early results showing the effectiveness of deterministic polishing for replicated optics.

Davis, Jacqueline↗

Differential Deposition for Surface Figure Corrections in Grazing Incidence X-Ray Optics

Differential deposition corrects the low- and mid- spatial-frequency deviations in the axial figure of Wolter-type grazing incidence X-ray optics. Figure deviations is one of the major contributors to the achievable angular resolution. Minimizing figure errors can significantly improve the imaging quality of X-ray optics. Material of varying thickness is selectively deposited, using DC magnetron sputtering, along the length of optic to minimize figure deviations. Custom vacuum chambers are built that can incorporate full-shell and segmented Xray optics. Metrology data of preliminary corrections on a single meridian of full-shell x-ray optics show an improvement of mid-spatial frequencies from 6.7 to 1.8 arc secs HPD. Efforts are in progress to correct a full-shell and segmented optics and to verify angular-resolution improvement with X-ray testing.

X-Ray Optics↗

Highlights of the ASPE 2004 Winter Topical Meeting on Free-Form Optics: Design, Fabrication, Metrology, Assembly

We present highlights from the American Society for Precision Engineering's 2004 winter topical meeting entitled Free-Form Optics: Design, Fabrication, Metrology, Assembly. We emphasize those papers that are most relevant to astronomical optics. Optical surfaces that transcend the bounds of rotational symmetry have been implemented in novel optical systems with fantastic results since the release of Polaroid's first instant camera. Despite these successes, free-form optics have found only a few niche applications and have yet to enter the mainstream. The purpose of this meeting is to identify the state of the art of free-form optics design, fabrication, metrology and assembly and to identify the technical and logistical challenges that inhibit their widespread use. Issues that will be addressed include: What are free-form optics? How can optical systems be made better with free-form optics? How can designers use free-form optics? How can free-form optics be fabricated? How can they be measured? How are free-form optical systems assembled? Control of multi-axis systems.

Ohl, Raymond G.↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

Collimated phase measuring deflectometry II: Re-design of the optical layout for high-curvature surfaces

Collimated phase measuring deflectometry (CPMD) is an optical metrology technique developed to improve upon traditional phase measuring deflectometry (PMD). CPMD utilizes telecentric imaging and collimated structured light illumination to eliminate the height-slope ambiguity present in traditional PMD measurements. After the publication of the first CPMD paper, efforts began to optimize the optical layout of the CPMD system. The first proposed change, and the one detailed in this work, was to move the Fourier transform (FT) lens closer to the surface under test (SUT). Moving the FT lens closer to the SUT meant that for a given FT lens diameter, a larger range of surface slopes on the SUT could be measured. This change to the optical layout was not trivial and introduced at least two concerns that had to be addressed: telecentricity in the imaging path and possible ghost reflections from the re-located FT lens. Here, in this work, we examine how these concerns were addressed and present results showing that the revised optical layout is capable of measurement results at least as good as the original CPMD optical layout. We also demonstrate the increased slope measuring range of the revised optical layout.

47 OTHER INSTRUMENTATION↗

Theodolite Ring Lights

Theodolite ring lights have been invented to ease a difficulty encountered in the well-established optical-metrology practice of using highly reflective spherical tooling balls as position references. A theodolite ring light produces a more easily visible reflection and eliminates the need for an autocollimating device. A theodolite ring light is a very bright light source that is well centered on the optical axis of the instrument. It can be fabricated, easily and inexpensively, for use on a theodolite or telescope of any diameter.

Clark, David↗

FIRST Mirror Review

As part of a JPL-funded effort to develop lightweight telescope technology suitable for far-infrared astronomy, COI designed and fabricated a spherical, f/1, 2-meter aperture prototype primary mirror using solely graphite/resin composite materials. To assess the performance of this technology, optical metrology of the mirror surface was performed from ambient to an intended operational temperature for IR-telescopes of 70K. Testing was performed horizontally in a cryogenic vacuum chamber at Arnold AFB, Tennessee. The test design had to accommodate requirements for rapid and uniform cooling across the optic, passivation of the ambient vibrational environment, and de-coupling of the mirror from the thermal strain of the test stand. An IR-wavelength phase shifting interferometer (PSI) was the primary instrument used to measure the mirror surface. From an initial surface figure of 2.1 microns RMS at ambient, a modest 3.9 microns of additional RMS surface error was induced at 70K. The thermally induced error was dominated by low-order deformations, of the type that could easily be corrected with secondary or tertiary optics. In addition to exceptional thermal stability, the mirror exhibited no measurable hysteresis between both ambient and cryo measurements.

Dodson, Kelly↗

Discorpy : algorithms and software for camera calibration and correction

Camera or lens-based detector calibration is essential for spatial accuracy in applications like dimensional tomography, optical metrology, and computer vision. Many methods and software exist yet there is still a lack of approaches that achieve both high accuracy and robustness while being easy to use and capable of handling a wide range of distortions. Radial lens distortion is common in high-resolution X-ray detector optics used in parallel-beam tomography at synchrotrons. Achieving sub-pixel accuracy requires calibrating with an optical target image. Although methods for characterizing radial distortion are well established, acquired images often also include perspective distortion and optical center offset. Here, we present our approaches to individually characterize and correct both types of distortion using a single calibration image, implemented in the Discorpy software.

36 MATERIALS SCIENCE↗

Laser System for Precise, Unambiguous Range Measurements

The Modulation Sideband Technology for Absolute Range (MSTAR) architecture is the basis of design of a proposed laser-based heterodyne interferometer that could measure a range (distance) as great as 100 km with a precision and resolution of the order of 1 nm. Simple optical interferometers can measure changes in range with nanometer resolution, but cannot measure range itself because interference is subject to the well-known integer-multiple-of-2 -radians phase ambiguity, which amounts to a range ambiguity of the order of 1 m at typical laser wavelengths. Existing rangefinders have a resolution of the order of 10 m and are therefore unable to resolve the ambiguity. The proposed MSTAR architecture bridges the gap, enabling nanometer resolution with an ambiguity range that can be extended to arbitrarily large distances. The MSTAR architecture combines the principle of the heterodyne interferometer with the principle of extending the ambiguity range of an interferometer by using light of two wavelengths. The use of two wavelengths for this purpose is well established in optical metrology, radar, and sonar. However, unlike in traditional two-color laser interferometry, light of two wavelengths would not be generated by two lasers. Instead, multiple wavelengths would be generated as sidebands of phase modulation of the light from a single frequency- stabilized laser. The phase modulation would be effected by applying sinusoidal signals of suitable frequencies (typically tens of gigahertz) to high-speed electro-optical phase modulators. Intensity modulation can also be used

Dubovitsky, Serge↗

Phase-Dependent Squeezing in Dual-Comb Interferometry

Manipulating the quantum noise of continuous-wave lasers through squeezing has reshaped optical interferometry. However, progress in optical frequency comb interferometry with pulsed squeezed sources has been limited, despite the role of frequency combs in ultraprecise optical metrology. Here, we introduce a new time-domain approach to characterizing squeezed femtosecond light pulses using dual-comb interferometry. Time-domain interferograms are generated via multiheterodyne beating between the modes of a Kerr soliton-squeezed frequency comb and a coherent state comb. The interferogram noise reveals phase-dependent squeezing and antisqueezing, dipping as much as 3.8 ± 0.2 dB below the shot noise level at alternating zero crossings. We model this nonstationary quantum noise as a periodic optical displacement of the squeezed comb by the coherent comb. These results support a route toward quantum-enhanced dual-comb timing applications and high-speed quantum state tomography with dual-comb interferometers.

Herman, Daniel Issac [University of Colorado, Boul↗

Measuring the Cryogenic Optical Alignment Between the Telescope Element and the Instruments Module of the James Webb Space Telescope

The alignment between the Aft Optical Subsystem (AOS) and the Integrated Science Instruments Module (ISIM) is non-adjustable in orbit, so the alignment must be carefully verified in a cryogenic vacuum environment prior to launch. Optical point source locations calibrated by optical metrology instruments are imaged through the AOS onto the Science Instruments to determine focal, lateral, and clock angle alignment. The pupil image of the AOS is overlaid onto the pupil image of the NIRCam to determine the tip and tilt alignment. In addition, an image from fiducial lights at the Primary Mirror checks the pupil alignment between the telescope entrance pupil, the telescope pupil mask, and the NIRCam aperture stop. The image positions are combined to determine the relative alignment between the Optical Telescope Element (OTE) and the ISIM in all six degrees of freedom with corresponding alignment uncertainties. Uncertainties in the position of focused images of the test sources and images from the pupils are derived from sensitivities of an optical model of the system and the Science Instrument sensing capability. Additional uncertainty in the pupil alignment measurement is due to uncertainty in the analytical removal of gravity effects that simulate the on-orbit alignment environment.

Whitman, Tony↗

Theoferometer for High Accuracy Optical Alignment and Metrology

The accurate measurement of the orientation of optical parts and systems is a pressing problem for upcoming space missions, such as stellar interferometers, requiring the knowledge and maintenance of positions to the sub-arcsecond level. Theodolites, the devices commonly used to make these measurements, cannot provide the needed level of accuracy. This paper describes the design, construction, and testing of an interferometer system to fill the widening gap between future requirements and current capabilities. A Twyman-Green interferometer mounted on a 2 degree of freedom rotation stage is able to obtain sub-arcsecond, gravity-referenced tilt measurements of a sample alignment cube. Dubbed a 'theoferometer,' this device offers greater ease-of-use, accuracy, and repeatability than conventional methods, making it a suitable 21st-century replacement for the theodolite.

Toland, Ronald↗

Advancing extreme pulsed lasers through measurements: summary of the pulsed laser metrology workshop

In this report we present consensus findings produced during the pulsed laser metrology (PLM) workshop (Boulder, CO, USA, August 2025). The workshop was a meeting of 35 scientists from private industry, academia, and U.S. government to compile a list of the metrology needs to support extreme pulsed laser development and implementation. We define ‘extreme pulsed lasers’ loosely as those with peak powers above 1 TW or multi-Joule pulse energies. Such lasers are being increasingly used and investigated for use in high energy particle acceleration, short wavelength radiation generation, laser-based fusion, etc. The rapid growth of these fields and the proliferation of extreme lasers for these applications, coupled with the extreme electric fields they generate and relative scarcity of such lasers, presents unique challenges to accuracy in their measurement. The PLM workshop was a two-day event designed to hear from users, developers, and researchers on the current state of optical metrology associated with these extreme pulsed lasers. The goal was to identify the most important measurement challenges limiting development and implementation of these lasers in practical applications. We report here the conclusions and recommendations of this workshop. The hope is that this document will become the first of many iterations which track the status of measurement needs supporting extreme pulsed lasers.

Lasers↗

Future foundries: A convergent manufacturing platform

This article introduces the Future Foundries platform developed at Oak Ridge National Laboratory, a first-generation research system designed to demonstrate convergent manufacturing. Convergent manufacturing brings together additive, subtractive, and transformative processes in a digitally interconnected environment to enable end-to-end production workflows. By linking traditionally discrete steps, convergent platforms accelerate production, improve repeatability, and support high-mix, low-volume manufacturing. The Future Foundries platform exemplifies this vision in practice by combining four modular, vendor-agnostic process cells that include robotic WAAM, induction heating, optical metrology, and machining, coordinated through an automated pallet handler and a ROS 2-based digital thread. This architecture provides the flexibility and scalability needed for agile production in small and medium-sized manufacturing enterprises and for field deployable manufacturing. Two case studies illustrate the platform’s capabilities. The first presents an integrated workflow for fabricating, transforming, and repairing critical replacement components, showing how consolidated thermal, additive, inspection, and machining operations reduce manual part handling and streamline process flow. The second case study highlights coordinated multi-part production enabled by automated pallet logistics and multi-cell scheduling. Together, these examples showcase convergent manufacturing as a practical and scalable strategy for strengthening domestic casting and forging capacity, improving supply-chain resilience, and enabling rapid, adaptable production of mission-critical components.

Convergent manufacturing↗

Burst characteristics of advanced accident-tolerant FeCrAl cladding under temperature transient testing

Here assessment of burst characteristics of accident-tolerant fuel (ATF) claddings is essential to evaluate the safety margins of nuclear reactors, and better understanding can enable accelerated licensing for reactor concepts that include the new materials. Therefore, this study investigated the burst behavior of an ATF candidate of C26M, which is an iron–chromium–aluminum alloy (FeCrAl) under transient testing like the simulated loss-of-coolant accident (LOCA) conditions, except the water-quenching phase, in light-water reactors (LWRs). The effect of LOCA specimen length was assessed in terms of post-burst tube parameters. No critical length effect was determined on the burst pressure, burst location, and burst size measurements. Burst temperature showed larger variation likely due to its measurement approach used in this study. The post-test diametral strain was identified as the critical parameter to reduce the specimen length as compared to tube burst length or width. Postmortem optical metrology and digital image correlation were employed to determine the local strain-state during the simulated LOCA, which showed the loading path was close to equibiaxial conditions in regions away from the burst location, rather than internally pressurized conditions (or “plane-strain” tension). Pst-test microstructural characterizations of the FeCrAl revealed that ductile damage was present at the edge of the outer radial surface while the rest of the material was ruptured via cleavage at LOCA burst temperatures. Furthermore, internal grain boundary cracks were observed at locations away from the tube burst region. This behavior was considered to occur during the cooling down period of the simulated LOCA test. Overall, this study aimed to provide essential data for fuel performance code development by considering micromechanics of the deformation and failure.

36 MATERIALS SCIENCE↗

Multi-pitch nano-accuracy surface profiler for strongly curved X-ray mirror metrology

We present our recent research and development effort on the Multi-Pitch Nano-accuracy Surface Profiler (MPNSP). This metrology instrument is developed to characterize strongly curved X-ray mirrors proposed to achieve diffraction-limited soft X-ray focusing for scientific applications at the synchrotron beamlines. The measurement process consists of forward-and-backward scans on the test mirror surface along its tangential direction at multiple pitch angles. Our research and development in this work aim to take the challenge of measuring strongly curved X-ray mirrors with a typical total slope range ≳10 mrad, while maintaining the Root Mean Square (RMS) value of measurement repeatability and self-consistency at 50 nrad RMS level. We first introduce the mechanical design, followed by a brief review of the mathematical model and the optimization algorithm for the MPNSP technique. By detecting the rotation axis of the mirror pitch with a machine vision approach, we can determine and then reduce the vertical distance between the pitch rotation axis and the test mirror surface to a sub-mm level. In addition, we describe a practical data acquisition procedure for strongly curved X-ray mirrors with a total slope range larger than the slope measuring range of the autocollimator used in the instrument. As a result, the proposed MPNSP measurements with different mirror orientations achieve remarkable self-consistency and reproducibility of < 50 nrad RMS in slope and < 0.5 nm RMS in height.

42 ENGINEERING↗

Nonlinear quantum interferometric spectroscopy with entangled photon pairs

Here, we develop closed expressions for a time-resolved photon counting signal induced by an entangled photon pair in an interferometric spectroscopy setup. Superoperator expressions in Liouville-space are derived that can account for relaxation and dephasing induced by coupling to a bath. Interferometric setups mix matter and light variables non-trivially, which complicates their interpretation. We provide an intuitive modular framework for this setup that simplifies its description. Based on the separation between the detection stage and the light–matter interaction processes, we show that the pair entanglement time and the interferometric time-variables control the observed physics time scale. Only a few processes contribute in the limiting case of small entanglement time with respect to the sample response, and specific contributions can be singled out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗