Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPACITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quantitative comparison of opacities calculated using the R -matrix and distorted-wave methods: Fe xvii

ABSTRACT We present here a detailed calculation of opacities for Fe xvii at the physical conditions corresponding to the base of the Solar convection zone. Many ingredients are involved in the calculation of opacities. We review the impact of each ingredient on the final monochromatic and mean opacities (Rosseland and Planck). The necessary atomic data were calculated with the R-matrix and the distorted-wave (DW) methods. We study the effect of broadening, of resolution, of the extent of configuration sets and of configuration interaction to understand the differences between several theoretical predictions as well as the existing large disagreement with measurements. New Dirac R-matrix calculations including all configurations up to the n = 4, 5, and 6 complexes have been performed as well as corresponding Breit–Pauli DW calculations. The DW calculations have been extended to include autoionizing initial levels. A quantitative contrast is made between comparable DW and R-matrix models. We have reached self-convergence with n = 6 R-matrix and DW calculations. Populations in autoionizing initial levels contribute significantly to the opacities and should not be neglected. The R-matrix and DW results are consistent under the similar treatment of resonance broadening. The comparison with the experiment shows a persistent difference in the continuum while the filling of the windows shows some improvement. This study defines our path to the next generation of opacities and opacity tables for stellar modelling.

Delahaye, F.↗

Opacities of singly and doubly ionized neodymium and uranium for kilonova emission modeling

ABSTRACT Even though the electromagnetic counterpart AT2017gfo to the binary neutron star merger GW170817 is powered by the radioactive decay of r-process nuclei, only few tentative identifications of light r-process elements have been made so far. One of the major limitations for the identification of heavy nuclei is incomplete or missing atomic data. While substantial progress has been made on lanthanide atomic data over the last few years, for actinides there has been less emphasis, with the first complete set of opacity data only recently published. We perform atomic structure calculations of neodymium (Z = 60) as well as the corresponding actinide uranium (Z = 92). Using two different codes [flexible atomic code (fac) and hartree–fock-relativistic (hfr)] for the calculation of the atomic data, we investigate the accuracy of the calculated data (energy levels and electric dipole transitions) and their effect on kilonova opacities. For the fac calculations, we optimize the local central potential and the number of included configurations and use a dedicated calibration technique to improve the agreement between theoretical and available experimental atomic energy levels (AELs). For ions with vast amounts of experimental data available, the presented opacities agree quite well with previous estimations. On the other hand, the optimization and calibration method cannot be used for ions with only few available AELs. For these cases, where no experimental nor benchmarked calculations are available, a large spread in the opacities estimated from the atomic data obtained with the various atomic structure codes is observed. We find that the opacity of uranium is almost double the neodymium opacity.

Flörs, A. (ORCID:0000000320242819)↗

First-principles opacity table of warm dense deuterium for inertial-confinement-fusion applications

Accurate knowledge of the optical properties of a warm dense deuterium-tritium (DT) mixture is important for reliable design of inertial confinement fusion (ICF) implosions using radiation-hydrodynamics simulations. The opacity of a warm dense DT shell essentially determines how much radiation from hot coronal plasmas can be deposited in the DT fuel of an imploding capsule. Even for the simplest species of hydrogen, the accurate calculation of their opacities remains a challenge in the warm-dense matter regime because strong-coupling and quantum effects play an important role in such plasmas. With quantum-molecular-dynamics (QMD) simulations, we have derived a first-principles opacity table (FPOT) of deuterium (and the DT mixture by mass scaling) for a wide range of densities from ρ D = 0.5 to 673.518 g/cm 3 and temperatures from T = 5000K up to the Fermi temperature T F for each density. Compared with results from the astrophysics opacity table (AOT) currently used in our hydrocodes, the FPOT of deuterium from our QMD calculations has shown a significant increase in opacity for strongly coupled and degenerate plasma conditions by a factor of 3–100 in the ICF-relevant photon-energy range. As conditions approach those of classical plasma, the opacity from the FPOT converges to the corresponding values of the AOT. By implementing the FPOT of deuterium and the DT mixture into our hydrocodes, we have performed radiation-hydrodynamics simulations for low-adiabat cryogenic DT implosions on the OMEGA laser and for direct-drive-ignition designs for the National Ignition Facility. In conclusion, the simulation results using the FPOT show that the target performance (in terms of neutron yield and energy gain) could vary from 10% up to a factor of ~ 2 depending on the adiabat of the imploding DT capsule; the lower the adiabat, the more variation is seen in the prediction of target performance when compared to the AOT modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relativistic opacities for astrophysical applications

Here, we report on the use of the Los Alamos suite of relativistic atomic physics codes to generate radiative opacities for the modeling of astrophysically relevant plasmas under local thermodynamic equilibrium (LTE) conditions. The atomic structure calculations are carried out in fine-structure detail, including full configuration interaction. Three example applications are considered: iron opacities at conditions relevant to the base of the solar convection zone, nickel opacities for the modeling of stellar envelopes, and samarium opacities for the modeling of light curves produced by neutron star mergers. In the first two examples, comparisons are made between opacities that are generated with the fully and semi-relativistic capabilities in the Los Alamos suite of codes. As expected for these highly charged, iron-peak ions, the two methods produce reasonably similar results, providing confidence that the numerical methods have been correctly implemented. However, discrepancies greater than 10% are observed for nickel and investigated in detail. In the final application, the relativistic capability is used in a preliminary investigation of the complicated absorption spectrum associated with cold lanthanide elements.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic structure considerations for the low-temperature opacity of Sn

Here, we have begun a preliminary investigation into the opacity of Sn at low temperatures (< 50 eV). The emissivity and opacity of Sn is a crucial factor in determining the utility of Sn in EUV lithography, with numerous industrial implications. To this end, we have been exploring the accuracy of some approximations used in opacity models for the relevant ion stages of Sn (neutral through ~ 18 times ionized). We also find that the use of intermediate-coupling, as compared to full configuration-interaction, is not adequate to obtain accurate line positions of the important bound-bound transitions in Sn. One requires full configuration-interaction to properly describe the strong mixing between the various n=4 sub-shells that give rise to the Δn= 0 transitions that dominate the opacity spectrum at low temperatures. Furthermore, since calculations that include full configuration-interaction for large numbers of configurations quickly become computationally prohibitive, we have explored hybrid calculations, in which full configuration-interaction is retained for the most important transitions, while intermediate-coupling is employed for all other transitions. After extensive exploration of the atomic structure properties, local-thermodynamic-equilibrium (LTE) opacities are generated using the ATOMIC code at selected temperatures and densities and compared to experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atomic structure considerations for the low-temperature opacity of Xenon

Here, we have begun a preliminary investigation into the opacity of Xe at low temperatures (<50 eV). The emissivity and opacity of Xe is a crucial factor in determining the utility of Xe in EUV lithography, with numerous industrial applications. To this end, we have been exploring the accuracy of some approximations used in opacity models for the relevant ion stages of Xe (6 times ionized through 20 times ionized). Due to the complexity of Xe atomic structure, one needs to use full configuration-interaction to properly describe the strong mixing in the various n=4 sub-shells that give rise to the Δn=0 and Δn=1 transitions that dominate the opacity spectrum at low temperatures. Since calculations that include full configuration-interaction for large numbers of configurations quickly become computationally prohibitive, we have explored hybrid calculations, in which full configuration-interaction is retained for the most important transitions, while intermediate coupling is employed for all other transitions. After verifying atomic structure properties, local-thermodynamic-equilibrium (LTE) opacities are generated using the ATOMIC code at selected temperatures and densities and compared to various experimental results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Control and diagnosis of temperature, density, and uniformity in x-ray heated iron/magnesium samples for opacity measurements

Experimental tests are in progress to evaluate the accuracy of the modeled iron opacity at solar interior conditions, in particular to better constrain the solar abundance problem [S. Basu and H. M. Antia, Phys. Rep. 457, 217 (2008)]. Here, we describe measurements addressing three of the key requirements for reliable opacity experiments: control of sample conditions, independent sample condition diagnostics, and verification of sample condition uniformity. The opacity samples consist of iron/magnesium layers tamped by plastic. By changing the plastic thicknesses, we have controlled the iron plasma conditions to reach (1) T{sub e} = 167 ± 3 eV and n{sub e} = (7.1 ± 1.5)× 10{sup 21} cm{sup −3}, (2) T{sub e} = 170 ± 2 eV and n{sub e} = (2.0 ± 0.2) × 10{sup 22} cm{sup −3}, and (3) T{sub e} = 196 ± 6 eV and n{sub e} = (3.8 ± 0.8) × 10{sup 22} cm{sup −3}, which were measured by magnesium tracer K-shell spectroscopy. The opacity sample non-uniformity was directly measured by a separate experiment where Al is mixed into the side of the sample facing the radiation source and Mg into the other side. The iron condition was confirmed to be uniform within their measurement uncertainties by Al and Mg K-shell spectroscopy. The conditions are suitable for testing opacity calculations needed for modeling the solar interior, other stars, and high energy density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

First systematic study of L-shell opacity at stellar interior temperatures

The first systematic study of opacity dependence on atomic number at stellar interior temperatures is used to evaluate discrepancies between measured and modeled iron opacity [J. E. Bailey et al., Nature (London) 517, 56 (2015)]. High-temperature ( > 180 eV) chromium and nickel opacities are measured with ± 6-10% uncertainty, using the same methods employed in the previous iron experiments. The 10%-20% experiment reproducibility demonstrates experiment reliability. The overall model-data disagreements are smaller than for iron. However, the systematic study reveals shortcomings in models for density effects, excited states, and open L-shell configurations. The 30%-45% underestimate in the modeled quasicontinuum opacity at short wavelengths was observed only from iron and only at temperature above 180 eV. Thus, either opacity theories are missing physics that has nonmonotonic dependence on the number of bound electrons or there is an experimental flaw unique to the iron measurement at temperatures above 180 eV.

74 ATOMIC AND MOLECULAR PHYSICS↗

First Measurement of Z Opacity Sample Evolution near Solar Interior Conditions Using Time-Resolved Spectroscopy

Opacity model differences with Fe opacity measurements at high temperature (T>1⁢8⁢0 eV ) and high electron density (𝑛 𝑒 >3×10 22 cm −3 ) at nearly solar interior conditions have remained unresolved [Bailey et al., Nature 517, 56 (2015) and Nagayama et al., Phys. Rev. Lett. 122, 235001 (2019)]. Systematic errors from temporal gradients are one hypothesis for the discrepancy. Past data recorded on x-ray film provided spectral measurements over a time determined by the 2.8-ns backlighter duration. Here, we present the first measurements of opacity sample temporal evolution using novel hCMOS ultrafast x-ray camera technology. The measured conditions, measured backlighter time history, and modeled opacities are used to show that temporal gradients do not resolve the model-data discrepancy. The methods demonstrated provide potential advantages, including opacities at more extreme conditions, spectral line shift measurements, and improved measurements at other facilities.

atomic spectra↗

Tungsten disulfide nanotubes enhance flow-induced crystallization and radio-opacity of polylactide without adversely affecting in vitro toxicity

Treatment of vascular disease, from peripheral ischemia to coronary heart disease (CHD), is poised for transformation with the introduction of transient implants designed to “scaffold” regeneration of blood vessels and ultimately leave nothing behind. Improved materials could expand the use of these devices. Here, we examine one of the leading polymers for bioresorbable scaffolds (BRS), polylactide (PLA), as the matrix of nanocomposites with tungsten disulfide (WS 2 ) nanotubes (WSNT), which may provide mechanical reinforcement and enhance radio-opacity. We evaluate in vitro cytotoxicity using vascular cells, flow-induced crystallization and radio-opacity of PLA-WSNT nanocomposites at low WSNT concentration. A small amount of WSNT (0.1 wt%) can effectively promote oriented crystallization of PLA without compromising molecular weight. And radio-opacity improves significantly: as little as 0.5 to 1 wt% WSNT doubles the radio-opacity of PLA-WSNT relative to PLA at 17 keV. The results suggest that a single component, WSNT, has the potential to increase the strength of BRS to enable thinner devices and increase radio-opacity to improve intraoperative visualization. Here, the in vitro toxicity results indicate that PLA-WSNT nanocomposites are worthy of investigation in vivo. Although substantial further preclinical studies are needed, PLA-WSNT nanocomposites may provide a complement of material properties that may improve BRS and expand the range of lesions that can be treated using transient implants.

36 MATERIALS SCIENCE↗

Parameterizing hot electron energy distributions for tabular emissivities and opacities

Cold Kα and Kβ emission spectroscopy is a powerful diagnostic for plasma conditions and distributions of energetic electrons produced in short pulse laser experiments. SPECT3D post-processes hydrodynamics code output and simulates high-resolution spectra and images for plasmas containing arbitrary distributions of hot electrons, however these calculations can become prohibitively expensive for plasmas requiring complex atomic data and detailed computational grids. To significantly increase calculation speed, it is desirable to use pre-configured opacity tables that include information about hot electrons, rather than calculating emissivity and opacity for every grid point by solving collisional-radiative atomic kinetic rate equations. However, to tabulate such opacities, a general parameter-based description of hot electron energy distributions must be found. To be practical, hot electrons should be represented with an analytic function of just a few parameters which, in addition to temperature and density, can be used to define parameter space for opacity tables. In this paper, we present a method that allows for describing a set of arbitrary binned hot electron distributions with a simple analytic function, with only a modest impact on the accuracy of the simulations. Increased calculation speeds of 50–100x are demonstrated. In conclusion, we also discuss details of opacity calculations and present synthetic spectroscopy data based on post-processing of detailed particle-in-cell simulations relevant to the ongoing experimental campaign at the Omega EP laser facility.

74 ATOMIC AND MOLECULAR PHYSICS↗

In-depth analysis of solar models with high-metallicity abundances and updated opacity tables

Context. As a result of the high-quality constraints available for the Sun, we are able to carry out detailed combined analyses using neutrino, spectroscopic, and helioseismic observations. These studies lay the ground for future improvements of the key physical components of solar and stellar models because ingredients such as the equation of state, the radiative opacities, or the prescriptions for macroscopic transport processes of chemicals are then used to study other stars in the Universe. Aims. We study the existing degeneracies in solar models using the recent high-metallicity spectroscopic abundances by comparing them to helioseismic and neutrino data and discuss the effect on their properties of changes in the micro and macro physical ingredients. Methods. We carried out a detailed study of solar models computed with a high-metallicity composition from the literature based on averaged 3D models that were claimed to resolve the solar modelling problem. We compared these models to helioseismic and neutrino constraints. Results. The properties of the solar models are significantly affected by the use of the recent OPLIB opacity tables and the inclusion of macroscopic transport. The properties of the standard solar models computed using the OPAL opacities are similar to those for which the OP opacities were used. We show that a modification of the temperature gradient just below the base of the convective zone is required to remove the discrepancies in solar models, particularly in the presence of macroscopic mixing. This can be simulated by a localised increase in the opacity of a few percent. Conclusions. We conclude that the existing degeneracies and issues in solar modelling are not removed by using an increase in the solar metallicity, in contradiction to what has been suggested in the recent literature. Therefore, standard solar models cannot be used as an argument for a high-metallicity composition. While further work is required to improve solar models, we note that direct helioseismic inversions indicate a low metallicity in the convective envelope, in agreement with spectroscopic analyses based on full 3D models.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tamper asymmetry and its effect on transmission for x-ray driven opacity simulations

This paper reports on synthetic transmission results from Lasnex [1] radiation-hydrodynamics simulations of opacity experiments carried out at Sandia National Laboratories' recently upgraded ZR facility. The focus is on experiments utilizing disk targets composed of a half-moon Fe/Mg mixture tamped on either end with 10- m CH and an additional 35- m beryllium tamper accessory on the end facing the spectrometer. Five x-ray sources with peak power ranging from 10 to 24 TW were used in the simulations to heat and backlight the opacity target. The dominant effect is that the beryllium behind the Fe/Mg mixture is denser and more opaque than the beryllium unshielded by metal during the times of greatest importance for the transmission measurement for all drives. This causes the simulated transmission to be lower than expected, and this is most pronounced for the case using the lowest drive power. While beryllium has a low opacity, its areal density is sufficiently high such that the expected reduction of the measured transmission is significant. This situation leads to an overestimate of iron opacity by 10-215% for a photon energy range of 975- 1775 eV for the 10-TW case. It is shown that if the tamper conditions are known, the transmission through each component of the target can be calculated and the resulting opacity can be corrected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sequential spectral line analysis for accurate density and temperature diagnosis of laboratory opacity measurements

The accuracy of iron opacity calculated in stellar interiors has been questioned since the discovery of the “solar problem” and the discrepancies between the measured and modeled iron opacity reported in 2015. Experimental opacity benchmarks require accurate temperature and density measurements, which were inferred by analyzing tracer magnesium spectra in those experiments. Could the observed discrepancy be explained by insufficient accuracy in the inferred temperature, density, and their uncertainties? Previous analyses may have yielded biased results due to three limitations: (1) simultaneous multi-line fitting, (2) approximations in line-shape models, and (3) exclusion of certain spectral lines due to insufficient background characterization. Notably, the first issue is a common concern for many inversion methods, including Bayesian inferences. We present a refined analysis method that overcomes these limitations, applied to three categories of iron opacity experiments (Anchor 1, 2, and 3). In particular, the sequential fitting method yields unbiased results with more realistic uncertainties by accounting for line inconsistencies in the parameter uncertainties. The average electron temperature and density values are 162 ± 6 eV and (7.0 ± 1.9) × 10 21 cm −3 for six Anchor 1 experiments, 189 ± 7 eV and (3.4 ± 0.3) × 10 22 cm −3 for 21 Anchor 2 experiments, and 201 ± 6 eV and (4.8 ± 1.1) × 10 22 cm −3 for nine Anchor 3 experiments. These results show ∼4% temperature and ∼20% density reproducibility over a decade, which also aligns with the inferred parameter uncertainties. In conclusion, the resulting temperature and density uncertainties lead to a quasi-continuum iron opacity variation of ±4%–7% for wavelengths below 9.5 Å, which is insufficient to explain the significant model-data discrepancies reported in 2015.

Absorption spectroscopy↗

R-matrix calculations for opacities: I. Methodology and computations

Abstract An extended version of the R -matrix methodology is presented for calculation of radiative parameters for improved plasma opacities. Contrast and comparisons with existing methods primarily relying on the distorted wave approximation are discussed to verify accuracy and resolve outstanding issues, particularly with reference to the opacity project (OP). Among the improvements incorporated are: (i) large-scale Breit–Pauli R -matrix calculations for complex atomic systems including fine structure, (ii) convergent close coupling wave function expansions for the ( e + ion) system to compute oscillator strengths and photoionization cross sections, (iii) open and closed shell iron ions of interest in astrophysics and experiments, (iv) a treatment for plasma broadening of autoionizing resonances as function of energy-temperature-density dependent cross sections, (v) a ‘top-up’ procedure to compare convergence with R -matrix calculations for highly excited levels, and (vi) spectroscopic identification of resonances and bound ( e + ion) levels. The present R -matrix monochromatic opacity spectra are fundamentally different from OP and lead to enhanced Rosseland and Planck mean opacities. An outline of the work reported in other papers in this series and those in progress is presented. Based on the present re-examination of the OP work, opacities of heavy elements might require revisions in high temperature-density plasma sources.

Pradhan, A. K. (ORCID:0000000187753643)↗

Time-dependent density functional theory applied to average atom opacity

We focus on studying the opacity of iron, chromium, and nickel plasmas at conditions relevant to experiments carried out at Sandia National Laboratories. In this work, we calculate the photoabsorption cross sections and subsequent opacity for plasmas using linear-response time-dependent density functional theory (TD-DFT). Our results indicate that the physics of channel mixing accounted for in linear-response TD-DFT leads to an increase in the opacity in the bound-free quasicontinuum, where the Sandia experiments indicate that models underpredict iron opacity. However, the increase seen in our calculations is only in the range of 5%–10%. Further, we do not see any change in this trend for chromium and nickel. This behavior indicates that channel mixing effects do not explain the trends in opacity observed in the Sandia experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗