Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Cables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

LWR Aging Management for Life Beyond 80

While several decades of materials degradation research enabled the current US fleet of Light Water Reactors (LWR) to plan to produce electrical power through extended operations up to 80 years of plant life, it now seems appropriate to evaluate what issues, methods, and timelines need to be considered to meet the expected electric power demands for life beyond eighty (LBE) years. To address these questions, it will be necessary to review the electrical capacity and the projected LWR fleet capacity including new builds and advanced reactors. This effort should begin with a materials degradation assessment focused on known and possible unknown issues using a reduced Expanded Materials Degradation Assessment [1], which was employed to identify knowledge gaps for a second license renewal (60-80 yrs.). The focus of the LBE assessment should include: Establishing a timeline to initiate assessments of possible materials aging issues and to ensure sufficient time to evaluate materials degradation research gaps; assessing components and materials to be evaluated, e.g., metals (reactor pressure vessels and alloys within and outside the pressure boundary), concrete, cables, as well as mitigation methods, advanced monitoring, and validation with ex-service materials; initiating a LBE research plan focused on developing an expanded mechanistic understanding of materials degradation and refined models through Codes and Standards evaluation for use by the nuclear industry; and maintaining and strengthening the nuclear materials human knowledge base to address new and as yet unknown degradation modes.

Chen, Xiang↗

Residual resistance ratio measurement system for Nb 3 Sn wires extracted from Rutherford cables

Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress of Tripwire: Multi-Modal Distributed Sensing for Repository Verification

This project is developing and demonstrating a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. This paper documents the results of the simulations and modeling efforts that have helped identify the optimal placement of the SFBs. Additionally, the paper includes the current progress on the multi-modal SFB-PCC system, including the fabrication of long-length (>3-m) fibers and their coupling to optical fibers.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Progress of Tripwire: Multi-modal Distributed Sensing for Repository Verification

This project is developing and demonstrating a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. This paper documents the results of the simulations and modeling efforts that have helped identify the optimal placement of the SFBs. Additionally, the paper includes the current progress on the multi-modal SFB-PCC system, including the fabrication of long-length (>3-m) fibers and their coupling to optical fibers.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A section 110 evaluation of the huron king test chamber, area 3, nevada national security site, nye county, nevada

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office tasked Desert Research Institute (DRI) with the identification and evaluation of the Huron King Test Chamber as part of their cultural resources program obligations under Section 110 of the National Historic Preservation Act. The Huron King nuclear test was a vertical line-of-sight weapons effects test that took place in Area 3 on June 24, 1980. Unique to this event was a specially designed aboveground test chamber that held a model defense communications satellite in a vacuum tank meant to replicate the space environment. Sponsored by the Defense Nuclear Agency, the purpose of the experiment was to understand the response of the satellite and its materials and equipment to an electromagnetic pulse and attendant radiation. Between July and August 2022, DRI conducted an archival review on the Huron King experiment and its associated test chamber. Subsequently, pedestrian fieldwork was undertaken at the Huron King Test Chamber by DRI on September 29, 2022. During fieldwork, the outside of the test chamber was documented using a Nevada State Historic Preservation Office Architectural Resource Assessment form. This effort included verifying the substructures that compose the test chamber as determined by the archival review, as well as obtaining a detailed photographic recordation of the exterior and assessing its current condition. Notably, the site where the Huron King test took place has been abandoned and almost entirely naturalized. All of the portable instrumentation trailers, communications and data cabling, and winch systems used to retract the test chamber following the detonation were removed after completion of the experiment in 1980. Only the subsidence crater and the test chamber remain as physical evidence of this experiment. Based on these findings, DRI recommends that the Huron King Test Chamber is eligible for listing in the National Register of Historic Places (NRHP) at the local level under Significance Criteria A and C and that it meets Criteria Consideration G for properties less than 50 years old.

54 ENVIRONMENTAL SCIENCES↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a high-temperature cell for cobalt-60 irradiations of aqueous solutions with in situ UV–visible spectroscopy

To understand the speciation of solutes in aqueous solutions in high temperature radiation environments, we report the design and fabrication of a custom-built, high temperature (≤300 °C) titanium irradiation cell with in situ optical spectroscopy capabilities, as afforded by coupled fiber optic cables. The wetted surfaces of the 8-inch tall cylindrical cell with 3.5 in. diameter are entirely made of titanium, sapphire, and gold, which are chemically and radiolytically inert. The initial benchmarking results are reported, including the baseline spectrum of deionized water as a function of temperature, the stability of a spectrum over 4 h at 100 °C, and an irradiated Fricke dosimetry solution under ambient irradiator temperature conditions (27.0 ± 0.5 °C). Further, the average gamma radiation dose rate in the cell in its current configuration is 26.1 ± 1.3 Gy min -1 . This cell has application in studying several processes throughout the nuclear fuel cycle, including the reactor coolant behavior.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Seismic monitoring of underground vibration: database of seismic data and ground truth

Seismic waves provide valuable insights into underground activities, serving as an essential tool for monitoring anomalies that could signal containment breaches in geological repositories. We aim to test and refine underground detection and geolocation techniques to identify anomalous vibration signals indicative of potential breaches, thereby strengthening georepository safeguards. We evaluate the effectiveness of two distinct, low-maintenance sensing technologies (surface geophones and underground distributed acoustic sensing (DAS) fiber optic cable) leveraging existing datasets. This report details the experimental designs, instrumentation, and data characteristics for both seismic and DAS arrays. Additionally, we provide a ground truth database documenting relevant operational activities for each experiment.

58 GEOSCIENCES↗

Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plutonium-238 Loadout Calorimeter Return To Service

The calorimeter in the transfer area in Building 7920 at the US Department of Energy’s Oak Ridge National Laboratory is used to measure the amount of 238 Pu in the Plutonium Heat Source Oxide. The calorimetry measurement is taken after the oxide is packaged in an ORISC (Oak Ridge Inner Shipping Capsule)/FSO (Fuel Storage Outer) assembly before loading into the Containment Vessel and shipping container. The equipment is used in three specific configurations: zero measurement (nothing in the sample cup), FSO measurement (actual measurement of 238 Pu), and reference calibration measurement (using the reference FSO as a known heat source). System checks were performed in July 2023 in preparation for scheduled material loadout. During these checks, personnel discovered that the reference FSO had experienced an electrical short in the heater cable and was no longer functional. The calorimeter was in the reference calibration measurement configuration at this time. Facility management was notified when the damage was discovered. The data from the Yokogawa recorder were pulled and analyzed for a span of time between September 2022 and July 2023. An unusual spike was found in the sample cup temperature data that started on October 19, 2022, and ended on October 20, 2022. The sample cup reached a temperature of 191.1°C. The maximum allowable temperature for the calorimeter thermopile to reach is 220°C based on the manufacturer statement provided in Appendix B of this report [1]. The calorimeter thermopile and the sample cup thermocouple are physically close to each other; therefore, the data suggest that the calorimeter itself never saw a temperature in excess of 191.1°C. Physical damage present on the cable, tape, and insulation suggests that the temperature reached a higher value in some locations within the sample cup than the data shows. Because of this discrepancy, testing of the calorimeter was required to confirm that the calorimeter is functioning the same as it was before the electrical short. The intent of this report is to assess the functionality of the calorimeter and determine if it is acceptable to use for 238 Pu loadout material measurement. Testing showed that the calorimeter is functionally equivalent to the initial calibration that was performed in the summer of 2021, and thus, the calorimeter was cleared to be used for its intended purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote quantification of Cm(III) and HNO 3 by fluorescence spectroscopy and chemometrics

A unique approach to remotely quantify Cm(III) (0–100 µg mL −1 ) in HNO 3 (1–12 M) using steady-state laser fluorescence spectroscopy and multivariate regression models was developed. Photoluminescence is amenable to remote measurements using fiber-optic cables and is sensitive to numerous lanthanide and actinide species. In-line measurements can provide feedback to support complex processing in harsh environments (e.g., hot cells) to help guide and optimize radiochemical separations. In this work, Cm(III) spectra were acquired remotely in a glove box as a function of HNO 3 concentration to better understand spectral characteristics and evaluate the utility of multivariate regression models in this system. Furthermore, the Cm(III) fluorescence peak shape, width, position, and intensity changed significantly as a function of HNO 3 concentration, likely because of the displacement of emission quenching inner-sphere water molecules and complexation with nitrate ions. Despite significant covariance and nonlinearity in the data, a D-optimal design strategy successfully minimized training set sample size and was used to build effective partial least squares regression models for Cm(III) and HNO 3 concentrations without a priori knowledge of solution conditions. Chemometrics for modeling complex fluorescence spectra are promising and may find widespread applicability for online analysis in numerous chemical systems found in the nuclear field.

Actinide↗

Online Lead/Water Heat Exchanger Sensor/System Feasibility-PNNL (Final Report)

On-line structural health corrosion monitoring in advanced lead fast reactor heat exchangers and molten salt reactor heat exchangers is desirable for detecting tube degradation prior to leaks that may allow mixing of heat exchanger fluids or release of radiological contamination beyond the design containment boundary. This program, On-Line Lead/Water Heat Exchanger Sensor/System Feasibility – PNNL 76092, demonstrates feasibility for an ultrasonic torsional wave mode sensor attached to the outside of a long (30.5-m) heat exchanger tube in the stagnant flow area where the tube joins a heat exchanger plenum and where it is possible to protect a sensor and cable from high-force flows. The sensor must be cable connected to a monitoring instrument near the heat exchanger. The sensor and cable management approach for periodic in-service inspection will be impractical to implement on existing heat exchangers; rather permanently mounted sensors must be installed in conjunction with heat exchanger fabrication. Previous work has shown low-temperature lead zirconate titanate (PZT) piezoceramic sensors are able to detect anomalies of interest in 3.0-m long tubes. These sensors have hereby been extended to a 30.5-m long tube more representative of commercial power heat exchanger designs. The program will continue to investigate higher temperature piezoelectric ceramics and long-term performance of high temperature adhesives and sealants and mechanical pressure coupling for 350-500 °C lead reactor environments and higher temperature (700 °C) molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗