General overview of multiphysics modeling and simulation at CEA/DES/IRESNE supporting safety, operating and development of nuclear reactors and facilities

This paper presents a general overview of the innovative multiphysics research/development activities carried on by the CEA/DES/IRESNE institute. Eight main different multiphysics fields addressed by IRESNE have been listed (among others: fuel fabrication, behavior of fuels, of reactors, of corium, radionuclide transfer to environment,...) in relation with the involved coupled physics: neutron transport, fluid mechanics, electro-magnetism, heat transfer, solid mechanics and (physico-)chemistry. The major mission of IRESNE institute is to study current and future nuclear systems integrated into a low carbon energy system. To fulfill this mission, IRESNE's activities rely on the development and the implementation of multiphysics modeling, advanced coupling scheme, data transfer techniques and dedicated multiphysics experimentations. Indeed, such multiphysics simulation approach of nuclear systems is today required to deal with the complex intrinsic features of studied phenomena. This approach aims at taking into account physical phenomena interactions, at each interest modeling scale, in order to reach an accurate and predictive behavior representation of a system component or of the whole system. The final objective is to contribute to the development of digital reactor, core and fuel at CEA, by progressing on applied mathematics, high-performance computing and physical mechanism understanding.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Second Target Station Target Streaming for the Preliminary Design of the Target Assembly

This report documents the analysis of dose rate fields from a combination of two sources stemming from the target system of the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) Second Target Station (STS). This analysis supports the target drive components’ lifetime estimates and conventional facilities’ preliminary design. The two sources detailed in this report are the radiation generated by the proton beam incident on the target and the activated cooling water in the pipes at the top of the target assembly. The analysis considers the STS target system in operational configuration, with all shielding in place. The dose rate fields are calculated in the target drive room and through the target drive room ceiling. This report calculates the thickness necessary for the target drive room’s high-density concrete ceiling to meet the 0.25 mrem/hr dose limit requirement in the high bay directly above the target drive room. In addition to sizing the target drive room ceiling, this report includes details of the dose field surrounding the target drive assembly to estimate the deposited dose in the target drive assembly components resulting from both streaming and decay of activated water. Prompt neutrons and gammas generated by the proton beam incident on the target primarily stream along the gaps between the target assembly and core vessel shielding. Because the models and analysis detailed in this report are based on the STS preliminary design, future analysis is needed to support the STS final design.

43 PARTICLE ACCELERATORS↗

Coordinated neutron and X-ray computed tomography of meteorites: Detection and distribution of hydrogen-bearing materials

The presence and distribution of hydrogen-bearing materials in meteorites are important constraints on processes in the early solar system, and the delivery of volatile constituents to growing planets. Here, in this paper, we show that coordinated neutron and X-ray computed tomography, NXCT, can reveal the presence and distributions of hydrogen-bearing materials in meteorites, and thus help constrain the presence and actions of water in the early solar system. NXCT is nearly nondestructive of meteorite samples. Neutron fluence in NXCT is approximately seven orders of magnitude less than in typical instrumental neutron activation analysis, and so produces little residual radioactivity and currently undetectable changes in isotope ratios. Heating during NXCT is minimal, but NXCT will overprint the record of cosmic ray exposure held in natural thermoluminescence. Two meteorites were examined. EET 87503 is a howardite, a regolith breccia inferred to be from the asteroid 4 Vesta, and contains fragments of eucrite basalt, diogenite pyroxenite, and H-rich carbonaceous chondrites. With NXCT, the chondrite fragments within the meteorite piece can be clearly located and characterized, in preparation for possible extraction and detailed analyses. Graves Nunataks (GRA) 06100 is a CR2 chondrite meteorite that contains abundant iron metal and H-bearing silicates from aqueous alteration. In NXCT, H-bearing altered material is clearly distinguished from metal, and its distribution in three dimensions is revealed as a constraint on the processes of alteration.

79 ASTRONOMY AND ASTROPHYSICS↗

Integration of a Wigner effect-based energy storage system with an advanced nuclear reactor

In this work, an innovative energy storage concept based on the purposeful creation of defects in crystalline material by neutron irradiation is presented. Lattice defects are generated when heavy particles collide with the atoms in a crystal structure, i.e., if the incoming particles have enough energy, recoil atoms are displaced from their initial lattice sites. Most of the displaced atoms will eventually combine with nearby vacancies, but some of them will come to rest in non-ideal locations. The energy held by displaced atoms is called Wigner energy. Lattice defects can migrate and form clusters, and the Wigner energy can be released from these groupings if sufficient activation energy is provided. In the nuclear industry, this effect is well-known since it represented an issue for graphite-moderated reactors. This work presents the conceptual design of an engineering system that exploits this physical process to store the energy of neutrons in advanced reactor concepts. In the first part of the paper, the theoretical performance of an energy storage system based on the Wigner effect is described. Given the lattice properties and the compatibility with the harsh reactor environment, graphite was selected as the candidate material for the irradiation targets. Both experimental data and molecular dynamics simulations confirmed that this system can achieve performance comparable with state-of-the-art batteries in terms of stored energy density. In the second part of the paper, the engineering challenges of this innovative technology and the proposed solutions are described. After defining the optimal irradiation conditions, the different steps of the operation of the proposed energy system (from energy storing to energy harvesting) were defined. Finally, the integration of this concept with advanced reactor designs, i.e., a Sodium-cooled Fast Reactor and a Molten Salt-cooled Reactor, was investigated and the corresponding performance was evaluated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

An In Situ Feed Monitoring System for Molten Salt Reactors with Fast Neutron Energy Spectrum Molten Salt Reactor Applications

Molten salt reactors (MSRs) are one of the six promising advanced reactor technologies selected for further research and development by the Generation IV International Forum. More than twenty MSR designs are actively being developed around the world. Several of these designs are liquid-fueled and intended for operation within the fast neutron energy spectrum.1 National regulations will require liquid-fueled MSRs to control and account for nuclear material within licensed facilities. Additionally, states with comprehensive safeguards agreements with the International Atomic Energy Agency (IAEA) are obligated to declare nuclear material quantities within facilities. In return, the IAEA Department of Safeguards independently verifies these quantities and provides assurance that the nuclear material and facility are being used only for peaceful purposes. One key distinction of liquid-fueled MSRs compared with other types of reactors is that in portions of the facility, the nuclear material is in bulk form rather than discrete items. Traditional nuclear material accounting techniques such as physical item counting and verification of serial numbers on fresh fuel assemblies do not translate directly to all process streams within liquid-fueled reactors. Liquid-fueled MSRs are typically designed with low excess reactivity. This feature provides safety benefits but also means that most MSRs require the addition of makeup fuel salt while a reactor is operational. The nuclear material in the initial fuel salt and in any makeup fuel salt must be quantified. Additionally, distinct nuclear material diversion and reactor misuse scenarios form the basis of the detection methods and monitoring systems developed for liquid-fueled MSRs. For example, the IAEA provides assurance that fuel salt containing nuclear material is not being diverted from the system, that the feed salt matches the reported actinide concentrations and uranium enrichment, and that no additional fertile material is being introduced into the system. Measurement systems currently used for nuclear material control and accounting are not directly applicable to achieving MSR safeguards goals. This paper concerns a system being designed to account for the nuclear material added to liquid-fueled MSRs and monitor for diversion and misuse scenarios related to MSR feed systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of pairing and neutron-excess on suppression of the above-barrier fusion cross-section in 19 O + 12 C

Fusion excitation functions for 19 O and 19 F + 12 C were simultaneously measured along with 20 O + 12 C using the active-target detector MuSIC@Indiana. Examination of the cross-section just above the barrier reveals a significant suppression of fusion for the 19 O + 12 C system starting at E 12 MeV. This suppression is not simply due to the reduced binding of the unpaired neutron in 19 O as 17 O + 12 C does not exhibit the same sharp suppression of the fusion cross-section. Multiple mean-field models are used as a reference to understand the measured fusion excitation functions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of the associated particle technique with high-resolution gamma-ray spectroscopy for in-field identification of chemical warfare agents and explosives

In this work, high-resolution prompt γ-ray neutron activation analysis (PGNAA) is performed using the associated particle (AP) technique with a deuterium-tritium neutron generator and high-purity germanium detector. Although the time resolution is inferior compared to similar systems employing fast scintillation γ-ray detectors, the strong background suppression combined with the high γ-ray energy resolution provides an important boost in sensitivity to certain key elements, especially relevant to field measurements of complex chemicals encased within thick layers of metal, such as in the case of recovered chemical warfare (CW) munitions. Results for various CW and explosive simulants contained within mock munitions are presented and compared with results obtained from traditional PGNAA measurements without the aid of the AP technique. Significant improvements in identification and discrimination between certain chemicals are achieved with the high energy resolution AP technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Compton suppression for enhancing trace element identification in neutron activation analysis of reference materials

Neutron activation analysis (NAA) is a powerful technique for identifying and quantifying trace elements in materials. However, challenges such as high dead times, spectral interferences, and high Compton continuum often arise. This study employs a Compton suppression system (CSS) to enhance NAA sensitivity by reducing the Compton continuum, thereby improving the peak-to-Compton ratio. National Institute of Standards and Technology certified reference materials 1632d, 1633c, and Canadian National Research Council TORT-1 were irradiated in a thermal and epithermal neutron flux under various irradiation, decay and counting times and analyzed using high-resolution gamma-ray spectroscopy with and without Compton suppression. The reduction factor was calculated to evaluate the effectiveness of the CSS, demonstrating significant background reduction and improved detection limits for trace elements. Additional experiments with a 137Cs point source demonstrated the impact of detector-source geometry on system performance, showing a decrease in the reduction factor as the source was moved further from the NaI detector. An optimum distance between the source and HPGe detector was observed, yielding the highest peak-to-Compton ratio. The results highlight the CSS's ability to minimize spectral interference and enhance elemental identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MEASUREMENT OF THE NEUTRON FLUENCE-RATES IN THE ADVANCED TEST REACTOR

The axial neutron fluence-rate distribution at the Advanced Test Reactor (ATR) is determined using a combination of pure nickel and cobalt-aluminium alloy dosimeter wires. Most irradiation programs at ATR need to know the fast neutron fluence-rate surrounding their experiment to correlate post-irradiation examination results with neutron dose. The activated dosimeter wires, which extend beyond the full fuelled region of the reactor core, are highly radioactive following the full cycle in ATR and must therefore be measured in the ATR canal. The system that is employed for these measurements is mechanical scanning mechanism is used to scan the activated wires across the face of a columnated shield and a NaI detector. This detector is not sufficiently calibrated to provide absolute activity measurements, therefore, the count-rate is recorded and normalized to the highest activity for that wire. Then, an approximately 3-mm long portion of the wire is removed from the highest activity region in the wire. The wires are then transferred, and an absolute activity measurement is made using a calibrated ionization chamber. These measurements are combined with corrections for decay, neutron energy spectrum, burnup, dosimeter composition, reactor power fluctuations, and reactor outages to determine the average axial neutron fluence-rate at various locations within ATR during the cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

New NDA Methods for Thorium Fuel Cycle Safeguards (Final Report)

This project developed portable Neutron Resonance Transmission Analysis (pNRTA) as a new non-destructive assay (NDA) method for thorium fuel cycles safeguards and other applications where multiple isotopes must be measured when present together. pNRTA leverages epithermal neutron resonances to assay multiple safeguards-relevant isotopes (e.g., 233 U and 235 U) when they are present together in a sample. Existing techniques are challenged by this task, driving the need for new active interrogation methods. With selected detectors, pNRTA works in high gamma-ray backgrounds from fission and activation products and 232 U progeny expected in thorium fuel cycle samples. This project leveraged a pNRTA system developed at Pacific Northwest National Laboratory (PNNL) and collaboration with the Massachusetts Institute of Technology (MIT). The system uses a commercially available deuterium-tritium (DT) neutron generator at short standoff (2 m). Key achievements in this project included: first-of-a-kind pNRTA quantitative measurements of 233 U oxide samples, an assessment of neutron detector technologies suitable for pNRTA in high gamma-ray background environments, experimentally demonstrating quantitative assay of samples containing 233 U and 235 U, and modeling studies showing the applicability of pNRTA to a wide range of material forms. Further, a custom algorithm was developed at MIT, which provided mean bias of 9% and relative standard deviation of 36% in assaying 233 U, 235 U, 238 U, and 232 Th content in eight measured samples. These outcomes form a solid technical basis for pNRTA as a new promising capability for international safeguards verification that is portable, non-destructive, quantitative, and isotopic specific.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron imaging of hydrogenous gases in porous-carbon materials around phase transitions

Focus herein is on hydrogenous gases interacting with porous-carbon materials on activated biochar at pressures ranging from 0 to 100 bar and temperatures from room (ambient) to cryogenic. Neutron radiography was conducted using a custom-made cell system to simultaneously image pure gas and gas interacting with the porous carbon. From neutron attenuation, the cross sections of methane and ethane and number concentrations were determined for different pressures and temperatures and compared with corresponding reference data. Sorption properties of the porous materials were investigated in situ with methane, ethane, and propane.

Ossler, Frederik [Lund University, Sweden]↗

Ceci N’est Pas Une Bombe: Lessons from a Field Experiment Using Neutron and Gamma Measurements to Confirm the Absence of Nuclear Weapons

In March 2023, the UN Institute for Disarmament Research held a verification experiment that included a mockup onsite inspection at a former military facility in the municipality of Menzingen, Switzerland. The experiment included a visit to the site by an inspection team, accompanied by the host team. Among other activities, radiation measurements were used to confirm the non-nuclear nature of selected items stored onsite. In this paper, we discuss the neutron and gamma measurement systems used during the experiment and the inspection protocols followed to confirm the absence of nuclear weapons. Furthermore, results from the experiment and a laboratory reproduction are presented, before concluding with lessons learned for how absence-confirmation measurements can help support verification of future arms control agreements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

mystic : software for autonomous discovery and design under uncertainty

Throughout the diverse range of science and engineering applications, there is a growing desire to develop computational methods that can reliably predict the behavior of complex systems. Specifically, there is a strategic need for tools that can robustly forecast the behavior of complex physical systems, where data may be high-dimensional, noisy, or sparse, and models of the system may be time-dependent or include uncertainty. We use mystic to build tools that leverage statistical learning, physics-informed learning, and active learning in the efficient generation of reliably predictive surrogates for complex physical systems. mystic is a robust, proven, open-source optimization and uncertainty quantification toolkit with over a decade of use in the design and optimization of neutron instrumentation, solar-powered drones, and gasguns, and in iterative tuning of models for Raman spectroscopy and elastoplastic materials strength. Recent developments have focused on automated learning of statistically robust surrogates under uncertainty, with applications in materials in extreme environments, nanostructures, materials simulations and strength models, and the failure of shielding under particle radiation. In 2020, McKerns demonstrated active learning of optimally robust surrogates with respect to new simulated data for molecular dynamics simulations of materials mixing in warm dense matter, and is currently applying active learning to the automated steering of particle accelerator beams and the optimal design and control of quantum optical sensor instrumentation.

42 ENGINEERING↗

First Direct Measurement of Mg (α,p) 25 Al and Implications for X-Ray Burst Model-Observation Comparisons

Type-I x-ray bursts can reveal the properties of an accreting neutron star system when compared with astrophysics model calculations. However, model results are sensitive to a handful of uncertain nuclear reaction rates, such as 22 Mg(α , p). We report the first direct measurement of 22 Mg(α , p), performed with the Active Target Time Projection Chamber. The corresponding astrophysical reaction rate is orders of magnitude larger than determined from a previous indirect measurement in a broad temperature range. Overall, our new measurement suggests a less-compact neutron star in the source GS1826-24.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New NDA Methods for Thorium Fuel Cycle Safeguards (Mid-Project Report)

This project is developing new Non-Destructive Assay (NDA) safeguards techniques for emergent thorium fuel cycles based on Neutron Resonance Transmission Analysis (NRTA), which can assay 233 U and 235 U when they are present together in a sample with potentially high gamma-ray backgrounds from fission products and 232 U. Existing passive techniques face large challenges for this task so new active interrogation methods are needed. This effort is also exploring how gamma-ray signatures can complement NRTA for enhanced assayed performance. This project leverages an NRTA system being developed at PNNL in collaboration with MIT, which uses a commercially available deuterium-tritium neutron generator at short standoff (~2 m). We aim to assess the feasibility and performance of these new NDA techniques for the range of relevant samples in thorium fuel cycles. Key advancements described in this mid-project report include NRTA system design for thorium safeguards measurements, characterization of 233 U oxide powder at PNNL, a survey of detector technologies suitable for NRTA in high gamma background environments, successful preliminary demonstration of a quantitative isotopic estimation algorithm, and first NRTA measurements of a thorium sample.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗