Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Neck”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

On the differences in continental rifting at the Earth, Mars and Venus

During the process of continental rifting on Earth, the lower ductile crust stretches, forming a neck, while the upper brittle crust is broken in blocks by faults, and the blocks sink down the thinned lower crust; if the stretching continues, the neck may break and a newly originated oceanic crust is formed at this place. The rift system structure depends on the depth of the boundary surface between the brittle crust and the ductile crust, the litospheric thickness, the tension value, etc.. The rigid brittle rifting when narrow necks form in the lower crust is characteristic of the contemporary Earth; on Mars the brittle rifting with large subsidence was characteristic of the Tharsis upland formation epoch. The ductile rifting is typical of the Venus. The differences in rheologic features of the lithospheres of different planets causes the variation in types of rifting.

Nikishin, A. M.

Extension of continental lithosphere - A model for two scales of basin and range deformation

The development of a model for deformation in an extending continental lithosphere that is stratified in density and strength is described. The lithosphere model demonstrates that the necking instabilities at two wavelengths originate due to a strong upper crust, a mantle layer, and a weak lower crust. It is observed that the dominant wavelengths of necking are controlled by layer thickness and the strength of the layers control the amplitude of the instabilities. The model is applied to the Basin and Range Province of the western U.S. where deformations in ranges and tile domains are detected. The relation between the Bouguer gravity anomaly and the deformations is studied. The data reveal that the horizontal scale of short wavelength necking correlates with the spacings of individual basins and ranges, and the longer wavelength corresponds to the width of tilt domains. The control of the Basin and Range deformation by two scales of extensional instability is proposed.

Zuber, M. T.

Acute Cutaneous Microvascular Flow Responses to Whole-Body Tilting in Humans

The transition from upright to head-down tilt (HDT) posture in humans increases blood pressure superior to the heart and decreases pressure inferior to the heart. Consequently, above heart level, myogenic arteriolar tone probably increases with HDT, in opposition to the withdrawal of baroreceptor-mediated sympathetic tone. We hypothesized that due to antagonism between central and local controls, the response of the facial cutaneous microcirculation to acute postural change will be weaker than that in the leg, where these two mechanisms reinforce each other. Cutaneous microvascular flow was measured by laser Doppler flowmetry simultaneously at the shin and the neck of 7 male and 3 female subjects. Subjects underwent a stepwise tilt protocol from standing control to 54 deg head-up tilt (HUT), 30 deg, 12 deg, O deg, -6 deg (HDT), -12 deg, -6 deg, O deg, 12 deg, 30 deg, 54 deg, and standing, for 30-sec periods with 10-sec transitions between postures. Flows at the shin and the neck increased significantly (P less than 0.05) from standing baseline to 12 deg HUT (252 +/- 55 and 126 +/- 9% (bar X +/- SE) of baseline, respectively). From 12 deg to -12 deg tilt, flows continued to increase at the shin (509 +/- 71% of baseline) but decreased at the neck to baseline levels (100 +/- 15% of baseline). Cutaneous microvascular flow recovered at both sites during the return to standing posture with significant hysteresis. Flow increases from standing to near-supine posture are attributed at both sites to baroreceptor-mediated vasodilation. The great dissimilarity in flow response magnitudes at the two measurement sites may be indicative of central/local regulatory antagonism above heart level and reinforcement below heart level.

Breit, Gregory A.

MAPS of Cancer

Our goal was to produce an interactive visualization from a mathematical model that successfully predicts metastases from head and neck cancer. We met this goal early in the project. The visualization is available for the public to view. Our work appears to fill a need for more information about this deadly disease. The idea of this project was to make an easily interpretable visualization based on what we call "functional maps" of disease. A functional map is a graphic summary of medical data, where distances between parts of the body are determined by the probability of disease, not by anatomical distances. Functional maps often beat little resemblance to anatomical maps, but they can be used to predict the spread of disease. The idea of modeling the spread of disease in an abstract multidimensional space is difficult for many people. Our goal was to make the important predictions easy to see. NASA must face this problem frequently: how to help laypersons and professionals see important trends in abstract, complex data. We took advantage of concepts perfected in NASA's graphics libraries. As an analogy, consider a functional map of early America. Suppose we choose travel times, rather than miles, as our measures of inter-city distances. For Abraham Lincoln, travel times would have been the more meaningful measure of separation between cities. In such a map New Orleans would be close to Memphis because of the Mississippi River. St. Louis would be close to Portland because of the Oregon Trail. Oklahoma City would be far from Little Rock because of the Cheyenne. Such a map would look puzzling to those of us who have always seen physical maps, but the functional map would be more useful in predicting the probabilities of inter-site transit. Continuing the analogy, we could predict the spread of social diseases such as gambling along the rivers and cattle rustling along the trails. We could simply print the functional map of America, but it would be more interesting to show meaningful patterns of dispersal. We had previously published the functional map of the head and neck, but it was difficult to explain to either patients or surgeons because that view of our body did not resemble anatomy. This discrepancy between functional and physical maps is just a mathematical restatement of the well-known fact that some diseases, such as head and neck cancer, spread in complex patterns, not always to the next nearest site. We had discovered that a computer could re-arrange anatomy so that this particular disease spreads to the next nearest site. The functional map explains over 95% of the metastases in 1400 patients. In a sense, we had graphed what our body "looks like" to a tumor. The tumor readily travels between adjacent areas in the functional map. The functional map is a succinct visual display of trends that are not easily appreciated in tables of probabilities.

Gray, Lincoln

Acute Cutaneous Microvascular Flow Responses to Whole-Body Tilting in Humans

The transition from upright to head-down tilt (HDT) posture in humans increases blood pressure superior to the heart and decreases pressure inferior to the heart. Consequently, above heart level, myogenic arteriolar tone probably increases with HDT, in opposition to the withdrawal of baroreceptor-mediated sympathetic tone. We hypothesized that due to antagonism between central and local controls, the response of the facial cutaneous micro- circulation to acute postural change will be weaker than that in the leg, where these two mechanisms reinforce each other. Cutaneous microvascular flow was measured by laser Doppler flowmetry simultaneously at the shin and the neck of 7 male and 3 female subjects. Subjects underwent a stepwise tilt protocol from standing control to 54 deg head-up tilt (HUT), 30 deg, 12 deg, 0 deg, -6 deg (HDT), -12 deg, -6 deg, 0 deg, 12 deg, 30 deg, 54 deg, and standing, for 30-sec periods with 10-sec transitions between postures. Flows at the shin and the neck increased significantly (P < 0.05) from standing baseline to 12 deg HUT (252 +/- 55 and 126 +/- 9% (bar-X +/- SE) of baseline, respectively). From 12 deg to -12 deg tilt, flows continued to increase at the shin (509 +/- 71% of baseline) but decreased at the neck to baseline levels (100 +/- 15% of baseline). Cutaneous microvascular flow recovered at both sites during the return to standing posture with significant hysteresis. Flow increases from standing to near-supine posture are attributed at both sites to baroreceptor-mediated vasodilation. The great dissimilarity in flow response magnitudes at the two measurement sites may be indicative of central/local regulatory antagonism above heart level and reinforcement below heart level.

Breit, Gregory A.

Visual- and Vestibular-Autonomic Influence on Short-Term Cardiovascular Regulatory Mechanisms

This synergy project was a one-year effort conducted cooperatively by members of the NSBRI Cardiovascular Alterations and Neurovestibular Adaptation Teams in collaboration with NASA Johnson Space Center (JSC) colleagues. The objective of this study was to evaluate visual autonomic interactions on short-term cardiovascular regulatory mechanisms. Based on established visual-vestibular and vestibular-autonomic shared neural pathways, we hypothesized that visually induced changes in orientation will trigger autonomic cardiovascular reflexes. A second objective was to compare baroreflex changes during postural changes as measured with the new Cardiovascular System Identification (CSI) technique with those measured using a neck barocuff. While the neck barocuff stimulates only the carotid baroreceptors, CSI provides a measure of overall baroreflex responsiveness. This study involved a repeated measures design with 16 healthy human subjects (8 M, 8 F) to examine cardiovascular regulatory responses during actual and virtual head-upright tilts. Baroreflex sensitivity was first evaluated with subjects in supine and upright positions during actual tilt-table testing using both neck barocuff and CSI methods. The responses to actual tilts during this first session were then compared to responses during visually induced tilt and/or rotation obtained during a second session.

Mullen, Thomas J.

Do vestibular otolith organs participate in human orthostatic blood pressure control?

We hypothesized that vestibular otolith organ stimulation contributes to human orthostatic responses. Twelve subjects underwent three 60 degrees upright tilts: (1) with the neck flexed from 0 degrees to 30 degrees relative to the body during 60 degrees tilt, such that the head moved from horizontal to 90 degrees above horizontal (0 to 1 Gz otolith stimulation); (2) with the head and body aligned, such that they tilted together to 60 degrees (0 to 0.87 Gz otolith stimulation); and (3) with the neck flexed 30 degrees relative to the body during supine conditions, and the neck then extended to -30 degrees during 60 degrees body tilting, such that the head remained at 30 degrees above horizontal throughout body tilting (constant 0.5 Gz otolith stimulation). All three tilt procedures increased thoracic impedance, sympathetic nerve activity (N = 8 of 12), arterial pressure, and heart rate relative to supine conditions (all P < 0.04). Within the first 20 s of tilt, arterial pressure increased most obviously in the 0 to 1 Gz otolith condition. Thoracic impedance tended to increase more in otolith-constant conditions, but no dependent variable differed significantly between tilt conditions, and no significant time x tilt interactions emerged. Otolith inputs may contribute to early transient adjustments to orthostasis. However, lack of significant main effects of tilt condition and time x tilt interactions suggests that potential otolith effects on the variables we studied are relatively subtle and ephemeral, or that other mechanisms compensate for a lack of change in otolith input with orthostasis.

Non-NASA Center

Dynamic and kinematic strategies for head movement control

This paper describes our analysis of the complex head-neck system using a combination of experimental and modeling approaches. Dynamical analysis of head movements and EMG activation elicited by perturbation of trunk position has examined functional contributions of biomechanically and neurally generated forces in lumped systems with greatly simplified kinematics. This has revealed that visual and voluntary control of neck muscles and the dynamic and static vestibulocollic and cervicocollic reflexes preferentially govern head-neck system state in different frequency domains. It also documents redundant control, which allows the system to compensate for lesions and creates a potential for substantial variability within and between subjects. Kinematic studies have indicated the existence of reciprocal and co-contraction strategies for voluntary force generation, of a vestibulocollic strategy for stabilizing the head during body perturbations and of at least two strategies for voluntary head tracking. Each strategy appears to be executed by a specific muscle synergy that is presumably optimized to efficiently meet the demands of the task.

Non-NASA Center

A dynamical model for reflex activated head movements in the horizontal plane

We present a controls systems model of horizontal-plane head movements during perturbations of the trunk, which for the first time interfaces a model of the human head with neural feedback controllers representing the vestibulocollic (VCR) and the cervicocollic (CCR) reflexes. This model is homeomorphic such that model structure and parameters are drawn directly from anthropomorphic, biomechanical and physiological studies. Using control theory we analyzed the system model in the time and frequency domains, simulating neck movement responses to input perturbations of the trunk. Without reflex control, the head and neck system produced a second-order underdamped response with a 5.2 dB resonant peak at 2.1 Hz. Adding the CCR component to the system dampened the response by approximately 7%. Adding the VCR component dampened head oscillations by 75%. The VCR also improved low-frequency compensation by increasing the gain and phase lag, creating a phase minimum at 0.1 Hz and a phase peak at 1.1 Hz. Combining all three components (mechanics, VCR and CCR) linearly in the head and neck system reduced the amplitude of the resonant peak to 1.1 dB and increased the resonant frequency to 2.9 Hz. The closed loop results closely fit human data, and explain quantitatively the characteristic phase peak often observed.

NASA Discipline Neuroscience

The role of microtubules in contractile ring function

During cytokinesis, a cortical contractile ring forms around a cell, constricts to a stable tight neck and terminates in separation of the daughter cells. At first cleavage, Ilyanassa obsoleta embryos form two contractile rings simultaneously. The cleavage furrow (CF), in the animal hemisphere between the spindle poles, constricts to a stable tight neck and separates the daughter cells. The third polar lobe constriction (PLC-3), in the vegetal hemisphere below the spindle, constricts to a transient tight neck, but then relaxes, allowing the polar lobe cytoplasm to merge with one daughter cell. Eggs exposed to taxol, a drug that stabilizes microtubules, before the CF or the PLC-3 develop, fail to form CFs, but form stabilized tight PLCs. Eggs exposed to taxol at the time of PLC-3 formation develop varied numbers of constriction rings in their animal hemispheres and one PLC in their vegetal hemisphere, none of which relax. Eggs exposed to taxol after PLC-3 initiation form stabilized tight CFs and PLCs. At maximum constriction, control embryos display immunolocalization of nonextractable alpha-tubulin in their CFs, but not in their PLCs, and reveal, via electron microscopy, many microtubules extending through their CFs, but not through their PLCs. Embryos which form stabilized tightly constricted CFs and PLCs in the presence of taxol display immunolocalization of nonextractable alpha-tubulin in both constrictions and show many polymerized microtubules extending through both CFs and PLCs. These results suggest that the extension of microtubules through a tight contractile ring may be important for stabilizing that constriction and facilitating subsequent cytokinesis.

NASA Discipline Cell Biology

Response of pontomedullary reticulospinal neurons to vestibular stimuli in vertical planes. Role in vertical vestibulospinal reflexes of the decerebrate cat

1. To investigate the neural substrate of vestibulospinal reflexes in decerebrate cats, we studied the responses of pontomedullary reticulospinal neurons to natural stimulation of the labyrinth in vertical planes. Our principal aim was to determine whether reticulospinal neurons that terminate in, or are likely to give off collaterals to, the upper cervical segments had properties similar to those of the vestibulocollic reflex (VCR). 2. Antidromic stimulation was used to determine whether the neurons projected to the neck, lower cervical, thoracic, or lumbar levels. Dynamics of the responses of spontaneously firing neurons were studied with sinusoidal stimuli delivered at 0.05-1 Hz and aligned to the plane of body rotation, that produced maximal modulation of the neuron (response vector orientation). Each neuron was assigned a vestibular input classification of otolith, vertical canal, otolith + canal, or spatial-temporal convergence (STC). 3. We found, in agreement with previous studies, that the largest fraction of pontomedullary reticulospinal neurons projected to the lumbar cord, and that only a small number ended in the neck segments. Neurons projecting to all levels of the spinal cord had similar responses to labyrinth stimulation. 4. Reticulospinal neurons that received only vertical canal inputs were rare (1 of 67 units). Most reticulospinal neurons (48%) received predominant otolith inputs, 18% received otolith + canal input, and only 9% had STC behavior. These data are in sharp contrast to the results of our previous studies of vestibulospinal neurons. A considerable portion of vestibulospinal neurons receives vertical canal input (38%), fewer receive predominantly otolith input (22%), whereas the proportion that have otolith + canal input or STC behavior is similar to our present reticulospinal data. 5. The response vector orientations of our reticulospinal neurons, particularly those with canal inputs (canal, otolith + canal, STC) were predominantly in the roll quadrants. There was no evidence of convergence of inputs from like canals across the midline (e.g., right anterior + left anterior). 6. Two characteristics of the VCR, STC behavior and bilateral input from symmetric vertical canals (in some muscles), cannot be accounted for by the reticulospinal neurons that we studied. Because these characteristics are also not seen in vestibulocollic neurons, they are likely to be the result of the appropriate convergence of vestibular signals in the spinal cord. 7. Pontomedullary reticulospinal neurons seem particularly well suited to play a role in gravity-dependent postural reflexes of neck and limbs.

NASA Discipline Neuroscience

The Effect of Sensory Noise Created by Compliant and Sway-Referenced Support Surfaces on Postural Stability

The purpose of the present experiment was to compare in normal human subjects the differential effects on postural stability of introducing somatosensory noise via compliant and/or sway-referenced support surfaces during quiet standing. The use of foam surfaces (two thicknesses: thin (0.95cm) and thick (7.62cm)) and sway-referenced support allowed comparison between two different types of destabilizing factors that increased ankle/foot somatosensory noise. Under some conditions neck extensions were used to increase sensory noise by deviating the vestibular system from its optimal orientation for balance control. The impact of these conditions on postural control was assessed through objective measures of instability. Thick foam and sway-referenced support conditions generated comparable instability in subjects, as measured by equilibrium score and minimum time-to-contact. However, simultaneous application of the conditions resulted in greater instability, suggesting a higher level of generated sensory noise and thus, different receptor types affected during each manipulation. Indeed, sway-referenced support generated greater anterior-posterior center-of-mass (COM) sway, while thick foam generated greater medio-lateral COM sway and velocity. Neck extension had minimal effect on postural stability until combined with simultaneous thick foam and sway-referenced support. Thin foam never generated enough sensory noise to affect postural stability even with noise added by sway-reference support or neck extension. These results provide an interesting window into the central integration of redundant sensory information and indicate the postural impact of sensory inputs is not solely based on their existence, but also their level of noise.

Forth, Katharine E.

Integration of a Finite Element Model with the DAP Bone Remodeling Model to Characterize Bone Response to Skeletal Loading

NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone in the absence of mechanical loading. The model was recently updated to include skeletal loading from exercise and free living activities to maintain healthy bone using a new daily load stimulus (DLS). This new formula was developed based on an extensive review of existing DLS formulas, as discussed in the abstract by Pennline et al. The DLS formula incorporated into the bone remodeling model utilizes strains and stress calculated from finite element model (FEM) of the bone region of interest. The proximal femur was selected for the initial application of the DLS formula, with a specific focus on the femoral neck. METHODS: The FEM was generated from CAD geometry of a femur using de-identified CT data. The femur was meshed using linear tetrahedral elements Figure (1) with higher mesh densities in the femoral neck region, which is the primary region of interest for the initial application of the DLS formula in concert with the DAP bone remodeling model. Nodal loads were applied to the femoral head and the greater trochanter and the base of the femur was held fixed. An L2 norm study was conducted to reduce the length of the femoral shaft without significantly impacting the stresses in the femoral neck. The material properties of the FEM of the proximal femur were separated between cortical and trabecular regions to work with the bone remodeling model. Determining the elements with cortical material properties in the FEM was based off of publicly available CT hip scans [4] that were segmented, cleaned, and overlaid onto the FEM.

Bone Remodeling

Hexapod Robot

The project I am working on at NASA-Johnson Space Center in Houston, TX is a hexapod robot. This project was started by various engineers at the Trick Lab. The goal of this project is to have the hexapod track a yellow ball or possibly another object from left to right and up/down. The purpose is to have it track an object like a real creature. The project will consist of using software and hardware. This project started with a hexapod robot which uses a senor bar to track a yellow ball but with a limited field of vision. The sensor bar acts as the robots "head." Two servos will be added to the hexapod to create flexion and extension of the head. The neck and head servos will have to be programmed to be added to the original memory map of the existing servos. I will be using preexisting code. The main programming language that will be used to add to the preexisting code is C++. The trick modeling and simulation software will also be used in the process to improve its tracking and movement. This project will use a trial and error approach, basically seeing what works and what does not. The first step is to initially understand how the hexapod works. To get a general understanding of how the hexapod maneuvers and plan on how to had a neck and head servo which works with the rest of the body. The second step would be configuring the head and neck servos with the leg servos. During this step, limits will be programmed specifically for the each servo. By doing this, the servo is limited to how far it can rotate both clockwise and counterclockwise and this is to prevent hardware damage. The hexapod will have two modes in which it works in. The first mode will be if the sensor bar does not detect an object. If the object it is programmed to look for is not in its view it will automatically scan from left to right 3 times then up and down once. The second mode will be if the sensor bar does detect the object. In this mode the hexapod will track the object from left to right or up and down. The hexapod will eventually be able to track the object moving its head and body in sync with on another and being able to rotate its body at 360 degrees. This is the plans and possible end results for the hexapod robot I will be working on during my summer internship at NASA Johnson Space Center. Since working on the hexapod project I have gained an increase interest in robotics. I enjoy the process of critical thinking. Also will working on this project I was challenged in a way that made more passionate to strive even more to become an engineer. I've learned that asking questions is an important part of the learning process. Also I learn that much more is accomplished when teamwork is applied.

Begody, Ericka

Exploration of Failure and Potential Damage Markers in Ti-6Al-4V

To improve prognostics for predicting component life, coupon tests were conducted on Ti-6Al-4V to investigate the development of damage. Various test types were employed (tension, creep, stress relaxation, and fatigue) under a wide range of temperatures and loading rates to engage various amounts of time-dependent and damage behavior. Both stiffness degradation and Poisson’s ratio were monitored to see if they were useful in indicating the initiation and accumulation of damage and subsequently the onset of failure. Stiffness exhibited large decreases with increasing strain when calculated using engineering stress and strain. However, minimal stiffness change was observed when using the true-stress and true- strain values. Detailed microscopy and image analysis were performed to document the actual physical damage that occurred within the various specimens. Two types of damage were observed: shallow surface cracks and internal pores. The severity of damage was greater in the region of localized necking and diminished further away from the neck. The area fraction of pores was higher in the necked region, yet even there it did not exceed more than a few percent and, in most cases, was significantly lower. It was observed that conditions that induced more time-dependent deformation (e.g., slower strain rate testing) resulted in a larger number of pores and larger pore sizes. The pores were always found to occur in the softer β-phase. The severity of observed damage was inconsistent with the large drop in engineering stiffness, but was more aligned with stiffness changes from the true-stress and -strain values. Poisson’s ratio was monitored on every test and showed promise as a damage indicator. It was found to be more sensitive than either the ultimate tensile strength or the inception of tertiary creep. However, calculation of Poisson’s ratio was found to be more involved than expected because of anisotropy and the presence of strain gradients along the specimen at large applied strains. First, the material had a moderate texture and resulted in anisotropy of the strains. Second, the evolution of Poisson’s ratio as a function of axial strain showed strange and unexpected behaviors, which necessitated more extensive analyses of its development. This led to an investigation on the use of small versus large strain approaches and the importance of making consistent measurements; that is, axial and transverse strain measurements over the same volume of material. Additionally, finite element analysis of a tensile sample indicated that non- uniform strain occurred in the sample prior to attaining the maximum strength. This, along with the location at which transverse strain was measured, had a significant influence on the resulting values of Poisson’s ratio. Based on this, lessons learned are offered for future testing.

Ti-6Al-4V

Modeling Space Radiation Induced Bone Changes in Rat Femurs through Finite Element Analysis

As the duration of manned missions outside of the Earth’s protective shielding increase, astronauts are at risk for exposure to space radiation. Various organ systems may be damaged due to exposure. This study investigates the bonestrength changes using finite element modeling of Long Evans rats (n=85) subjected to graded, head-only proton (0, 10, 25, and 100 cGy, 150 MeV/n) and 28silicon (0, 10, 25, and 50 cGy, 300 MeV/n) radiation. The strength of the femoral neck will be examined due its clinical relevance to hip fractures. It has been shown in previous studies that bone mineral density was not reduced at the site of fracture. These findings question whether measurements of bone mineral density may be used to assess risk of hip fracture. The mechanisms leading to the irregular relationship between bone density and strength are still uncertain within literature and investigated to greater extent in clinical applications. Finite element analysis within this study simulated physiological loading of the femoral neck. No significant changes in femoral neck strength were found across doses of proton or 28silicon head-only radiation. Future work includes performing mechanical testing of the bone samples. Moving from mouse to larger animal models may also provide the increased lifespan for assessing the long-term outcomes of radiation exposure.

Dale Johnson

Effect of dynamic exercise on human carotid-cardiac baroreflex latency

We compared the beat-to-beat responses of heart rate (HR) after brief activation of carotid baroreceptors in resting humans with the responses obtained during mild-to-moderate levels of dynamic exercise [25 and 50% of peak O2 uptake (VO2peak)] to investigate the effect of exercise on baroreflex latency. Carotid baroreceptors were activated by a pressure pulse (5 s) of neck suction (NS, -80 Torr) and neck pressure (NP, +40 Torr) during held expiration. At rest the peak change in HR to NS/NP occurred during the first several heartbeats (1st-3rd beat), whereas during mild and moderate exercise peak HR responses occurred near the end of the NS/NP pulse (6th-8th beat). In contrast, time (s) to the peak change in HR was not different between rest and exercise (P > 0.05). Reflex tachycadia to NP progressively decreased during exercise (17 +/- 3, 10 +/- 1, and 4 +/- 1% of control, rest vs. 25% VO2peak, vs. 50% VO2peak, respectively, P < 0.05), and a strong positive correlation was found between the magnitude of the reflex tachycardia and a measure of HR variability (cardiac vagal tone index, r = 0.74, P < 0.0001). Reflex bradycardia to NS gradually increased during exercise (13 +/- 2, 17 +/- 2, and 18 +/- 2% of control, rest vs. 25% VO2peak, vs. 50% VO2peak, respectively, P = 0.10) and was negatively correlated with cardiac vagal tone (r = 0.42, P < 0.06).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Program Space Physiology and Countermeasures

Predicting fracture behavior in single crystal nickel using a coupled crystal plasticity phase field damage approach

Understanding the fracture behavior of single crystal metals is critical for predicting material performance under mechanical loading. Here, in this study, we investigate the fracture characteristics of single crystal nickel tensile bars using a crystal plasticity coupled phase field damage (CP-PFD) model. Experimental tensile tests were conducted on 15 specimens spanning five crystallographic orientations and three thickness variants per orientation. The results revealed two distinct fracture modes: brittle fractures with 45-degree angled surfaces and ductile fractures characterized by significant necking. The CP-PFD model successfully replicated these fracture behaviors, demonstrating strong agreement with experimental observations. The model effectively predicted the strain at which necking and fracture occurred, as well as the orientation-dependent fracture mechanisms. By comparing experimental and simulated fracture surfaces, we establish the CP-PFD model as a robust tool for predicting single crystal behavior and damage evolution. This work provides insight into the microstructural dependence of fracture behavior and establishes a predictive framework for modeling orientation-dependent damage evolution in single-crystal nickel.

Crystal plasticity