Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NAVIGATION SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of the NASA VALT digital navigation system

The research to develop and fabricate a terminal area navigation system for use in the NASA VTOL Approach and Landing Technology (VALT) program. The results of that effort are reported. The navigation system developed and fabricated was based on a general purpose airborne digital computer. A set of flight hardware units was fabricated to create the necessary analog, digital and human interface with the computer. A comprehensive package of software was created to implement the control and guidance laws required for automatic and flight director approaches that are curved in two planes. A technique was developed that enables the generation of randomly shaped lateral paths from simple input data. The lateral path concept combines straight line and elliptical-curved segments to fit a continuous curved path to the data points. A simple, fixed base simulation was put together to assist in developing and evaluating the system. The simulation was used to obtain system performance data during simulated curved-path approaches.

Mcconnell, W. J., Jr.↗

A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An electromagnetically navigated bronchoscopy system was constructed with accurate registration of an electromagnetic tracker and the CT volume on the basis of an improved marker-free registration approach that uses the bronchial centerlines and bronchoscope tip center information. The fiducial and target registration errors of our electromagnetic navigation system were about 6.6 and 4.5 mm in dynamic bronchial phantom validation.

60 APPLIED LIFE SCIENCES↗

Redundant Strapdown Laser Gyro Navigation System

For the last several years, NASA has pursued the development of low-cost high-reliability inertial navigation systems that would satisfy a broad spectrum of future space and avionics missions. Two specific programs have culminated in the construction of a Redundant Strapdown Laser Gyro Navigation System. These two programs were for development of a space ultrareliable modular computer (SUMC) and a redundant laser gyro inertial measurement unit (IMU). The SUMC is a digital computer that employs state-of-the-art large-scale integrated circuits configured in a functional modular breakdown. The redundant laser gyro IMU is a six-pack strapdown sensor package in a dodecahedron configuration which uses six laser gyros to provide incremental angular positions and six accelerometers for linear velocity outputs. The sensor arrangement allows automatic accommodation of two failures; a third failure can be tolerated provided it can be determined. The navigation system also includes redundant power supplies, built-in test-equipment (BITE) circuits for failure detection, and software which provides for navigation, redundancy management, and automatic calibration and alignment.

Mcpherson, B. W.↗

Intraoperative Localization of Tantalum Markers for Proton Beam Radiation of Choroidal Melanoma by an Opto-Electronic Navigation System: A Novel Technique

Purpose: External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described. Methods and Materials: A navigated reference base was attached noninvasively to the eye, and a navigated pointer device was used to record the spatial position of the tantalum markers, the tumor, and anatomical landmarks. Measurement accuracy was assessed on ex vivo porcine eye specimen by repetitive recording of the tantalum marker positions. The method was applied intraoperatively on 4 patients undergoing routine tantalum clip surgery. The spatial position information delivered by the navigation system was compared to the geometric data generated by the EYEPLAN software. Results: In the ex vivo experiments, the maximum repetition error was 0.34 mm. For the intraoperative application, the root mean square error of paired-points matching of the marker positions from the navigation system and from the EYEPLAN software was 0.701-1.25 mm. Conclusions: Navigation systems are a feasible tool for accurate localization of tantalum markers and anatomic landmarks. They can provide additional geometric information, and therefore have the potential to increase the reliability and accuracy of external beam proton radiation therapy for choroidal melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitivity analysis of helicopter IMC decelerating steep approach and landing performance to navigation system parameters

Results of a study to investigate, by means of a computer simulation, the performance sensitivity of helicopter IMC DSAL operations as a function of navigation system parameters are presented. A mathematical model representing generically a navigation system is formulated. The scenario simulated consists of a straight in helicopter approach to landing along a 6 deg glideslope. The deceleration magnitude chosen is 03g. The navigation model parameters are varied and the statistics of the total system errors (TSE) computed. These statistics are used to determine the critical navigation system parameters that affect the performance of the closed-loop navigation, guidance and control system of a UH-1H helicopter.

Karmali, M. S.↗

Lunar Roving Vehicle Navigation System Performance Review

The design and operation of the lunar roving vehicle (LRV) navigation system are briefly described. The basis for the premission LRV navigation error analysis is explained and an example included. The real time mission support operations philosophy is presented. The LRV navigation system operation and accuracy during the lunar missions are evaluated.

Smith, Earnest C.↗

Navigation accuracy analysis for the TDRSS Onboard Navigation System (TONS) experiment on EP/EUVE

A navigation accuracy analysis of the TONS (TDRSS Onboard Navigation System) experiment on the Explorer Platform/Extreme Ultraviolet Explorer (EP/EUVE) is reported. The analysis process includes both sequential estimation covariance analysis and the processing of 'realistic' simulated tracking data. The sensitivity of the navigation accuracy to force modeling and measurement errors is evaluated as a function of the tracking schedule and the process noise model tuning parameters.

Gramling, C. J.↗

Onboard Navigation Systems Characteristics

The space shuttle onboard navigation systems characteristics are described. A standard source of equations and numerical data for use in error analyses and mission simulations related to space shuttle development is reported. The sensor characteristics described are used for shuttle onboard navigation performance assessment. The use of complete models in the studies depend on the analyses to be performed, the capabilities of the computer programs, and the availability of computer resources.

Source record↗

An analysis of outer planet navigation systems.

Various components of outer planet navigation systems are examined using the Saturn portion of a MJS77 Mission as an example. Special emphasis is placed upon the planet relative and satellite relative orbit determination performance. The effects of constant and stochastic error sources are investigated by means of covariance studies, simulations, and worst case analyses. Preliminary requirements for both the quality of the radiometric and optical data, and for the a priori knowledge of satellite and planetary ephemerides are given for various levels of navigational accuracy. Mission benefits resulting from improved navigational capabilities are discussed.

Ondrasik, V. J.↗

Fault detection and exclusion in multisensor navigation systems

In order for a multisensor navigation system to meet integrity requirements, there must be a way of detecting erroneous measurements, using only data from those measurements. This can be accomplished using a parity space estimation algorithm. Erroneous measurements must then be removed from the position solution; the entire process is called fault detection and exclusion (FDE). A baseline FDE algorithm has been determined, and is capable of working in real time on present affordable hardware.

Bernath, Gregory N.↗

Demonstration of the Orion Optical Navigation System on Artemis I

The Orion Optical Navigation (OpNav) System is a first-of-its-kind navigation capability that was demonstrated in space on the Artemis I mission. The OpNav System was tested under a variety of conditions, resulting in over one thousand images of Earth, Moon, and starfields. Pairing the images with ground tracking information, not only did Artemis I provide a basis to evaluate the performance of the Orion OpNav system, but produced a valuable set of imagery/data that can be used to further development and testing of other optical navigation systems.

Optical Navigation↗

Demonstration of the Orion Optical Navigation System on Artemis I

The Orion Optical Navigation (OpNav) System is a first-of-its-kind navigation capability that was demonstrated in space on the Artemis I mission. The OpNav System was tested under a variety of conditions, resulting in over one thousand images of Earth, Moon, and starfields. Pairing the images with ground tracking information, not only did Artemis I provide a basis to evaluate the performance of the Orion OpNav system, but produced a valuable set of imagery/data that can be used to further development and testing of other optical navigation systems.

optical navigation↗