Monte Carlo simulation analysis for radiation damage on Glidcop Al-15 caused by 17-20 MeV/u heavy ions

The Facility for Rare Isotope Beams (FRIB) SRF linear heavy-ion accelerator is designed to accelerate all ions up to uranium to a maximum beam power of 400 kW. Several beam intercepting devices (BIDs) are essential to the successful operation of the accelerator, including a low power charge selector (LPCS) made of copper containing 0.15% precipitated aluminum oxide by weight called Glidcop Al-15. As FRIB ramps up the primary beam power beyond the current 20 kW level, the charge selector must withstand higher radiation damage rates, typically measured in displacements per atom (dpa). Significant beam induced radiation damage including significant deformation, like swelling, blistering, and cracking has been observed on a recently removed LPCS. We also observed physical features up to about 5.5 mm wide and appear to be deeper than the projected range of any ions. This paper presents the results of Monte Carlo simulations carried out using the Particle and Heavy Ion Transport code System (PHITS), quantifying the total damage dose and ion concentration, etc. Simulating an accurate irradiation history is essential to determining the scope of post irradiation examination (PIE) work.

Fletcher, Ethan [Michigan State U.]↗

Direct Monte Carlo Simulations of Hypersonic Viscous Interactions Including Separation

Results of calculations obtained using the direct simulation Monte Carlo method for Mach 25 flow over a control surface are presented. The numerical simulations are for a 35-deg compression ramp at a low-density wind-tunnel test condition. Calculations obtained using both two- and three-dimensional solutions are reviewed, and a qualitative comparison is made with the oil flow pictures highlight separation and three-dimensional flow structure.

Moss, James N.↗

Determination of the effective diffusivity of water in a poly (methyl methacrylate) membrane containing carbon nanotubes using kinetic Monte Carlo simulations

A kinetic Monte Carlo (kMC) simulation algorithm is developed for computing the effective diffusivity of water molecules in a poly(methyl methacrylate) (PMMA) matrix containing carbon nanotubes (CNTs) at several loadings. The simulations are conducted on a cubic lattice to the bonds of which rate constants are assigned governing the elementary jump events of water molecules from one lattice site to another. Lattice sites belonging to PMMA domains of the membrane are assigned different rates than lattice sites belonging to CNT domains. Values of these two rate constants are extracted from available numerical data for water diffusivity within a PMMA matrix and a CNT pre-computed on the basis of independent atomistic molecular dynamics simulations, which show that water diffusivity in CNTs is 3 orders of magnitude faster than in PMMA. Our discrete-space, continuum-time kMC simulation results for several PMMA-CNT nanocomposite membranes (characterized by different values of CNT length L and diameter D and by different loadings of the matrix in CNTs) demonstrate that the overall or effective diffusivity, D{sub eff}, of water in the entire polymeric membrane is of the same order of magnitude as its diffusivity in PMMA domains and increases only linearly with the concentration C (vol. %) in nanotubes. For a constant value of the concentration C, D{sub eff} is found to vary practically linearly also with the CNT aspect ratio L/D. The kMC data allow us to propose a simple bilinear expression for D{sub eff} as a function of C and L/D that can describe the numerical data for water mobility in the membrane extremely accurately. Additional simulations with two different CNT configurations (completely random versus aligned) show that CNT orientation in the polymeric matrix has only a minor effect on D{sub eff} (as long as CNTs do not fully penetrate the membrane). We have also extensively analyzed and quantified sublinear (anomalous) diffusive phenomena over small to moderate times and correlated them with the time needed for penetrant water molecules to explore the available large, fast-diffusing CNT pores before Fickian diffusion is reached.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo simulation methods in moment-based scale-bridging algorithms for thermal radiative-transfer problems

We present a moment-based acceleration algorithm applied to Monte Carlo simulation of thermal radiative-transfer problems. Our acceleration algorithm employs a continuum system of moments to accelerate convergence of stiff absorption–emission physics. The combination of energy-conserving tallies and the use of an asymptotic approximation in optically thick regions remedy the difficulties of local energy conservation and mitigation of statistical noise in such regions. We demonstrate the efficiency and accuracy of the developed method. We also compare directly to the standard linearization-based method of Fleck and Cummings [1]. A factor of 40 reduction in total computational time is achieved with the new algorithm for an equivalent (or more accurate) solution as compared with the Fleck–Cummings algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Role of Boundary Conditions in Monte Carlo Simulation of MEMS Devices

A study is made of the issues surrounding prediction of microchannel flows using the direct simulation Monte Carlo method. This investigation includes the introduction and use of new inflow and outflow boundary conditions suitable for subsonic flows. A series of test simulations for a moderate-size microchannel indicates that a high degree of grid under-resolution in the streamwise direction may be tolerated without loss of accuracy. In addition, the results demonstrate the importance of physically correct boundary conditions, as well as possibilities for reducing the time associated with the transient phase of a simulation. These results imply that simulations of longer ducts may be more feasible than previously envisioned.

Nance, Robert P.↗

Interpretation of time-of-flight distributions for neutral particles under pulsed laser evaporation using direct Monte Carlo simulation

A theoretical study of the time-of-flight (TOF) distributions under pulsed laser evaporation in vacuum has been performed. A database of TOF distributions has been calculated by the direct simulation Monte Carlo (DSMC) method. It is shown that describing experimental TOF signals through the use of the calculated TOF database combined with a simple analysis of evaporation allows determining the irradiated surface temperature and the rate of evaporation. Analysis of experimental TOF distributions under laser ablation of niobium, copper, and graphite has been performed, with the evaluated surface temperature being well agreed with results of the thermal model calculations. General empirical dependences are proposed, which allow indentifying the regime of the laser induced thermal ablation from the TOF distributions for neutral particles without invoking the DSMC-calculated database.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo simulations of electron thermalization in alkali iodide and alkaline-earth fluoride scintillators

A Monte Carlo model of electron thermalization in inorganic scintillators, which was developed and applied to CsI in a previous publication [Wang et al., J. Appl. Phys. 110, 064903 (2011)], is extended to another material of the alkali halide class, NaI, and to two materials from the alkaline-earth halide class, CaF{sub 2} and BaF{sub 2}. This model includes electron scattering with both longitudinal optical (LO) and acoustic phonons as well as the effects of internal electric fields. For the four pure materials, a significant fraction of the electrons recombine with self-trapped holes and the thermalization distance distributions of the electrons that do not recombine peak between approximately 25 and 50 nm and extend up to a few hundreds of nanometers. The thermalization time distributions of CaF{sub 2}, BaF{sub 2}, NaI, and CsI extend to approximately 0.5, 1, 2, and 7 ps, respectively. The simulations show that the LO phonon energy is a key factor that affects the electron thermalization process. Indeed, the higher the LO phonon energy is, the shorter the thermalization time and distance are. The thermalization time and distance distributions show no dependence on the incident {gamma}-ray energy. The four materials also show different extents of electron-hole pair recombination due mostly to differences in their electron mean free paths (MFPs), LO phonon energies, initial densities of electron-hole pairs, and static dielectric constants. The effect of thallium doping is also investigated for CsI and NaI as these materials are often doped with activators. Comparison between CsI and NaI shows that both the larger size of Cs{sup +} relative to Na{sup +}, i.e., the greater atomic density of NaI, and the longer electron mean free path in NaI compared to CsI contribute to an increased probability for electron trapping at Tl sites in NaI versus CsI.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new paradigm for petascale Monte Carlo simulation: Replica exchange Wang-Landau sampling

We introduce a generic, parallel Wang-Landau method that is naturally suited to implementation on massively parallel, petaflop supercomputers. The approach introduces a replica-exchange framework in which densities of states for overlapping sub-windows in energy space are determined iteratively by traditional Wang-Landau sampling. The advantages and general applicability of the method are demonstrated for several distinct systems that possess discrete or continuous degrees of freedom, including those with complex free energy landscapes and topological constraints.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulation of reentry plasmas

Attention is given to the treatment of ionization and plasma effects in the direct simulation Monte Carlo method. The requirements for accurate modeling of reentry plasmas are discussed along with the difficulties these requirements present. The current method for modeling such plasmas is reviewed and an alternative method is presented. Both methods are applied to the flow of a 10 km/s shock wave in air at 0.1 torr; a flowfield directly relevant to the projected aeroassisted orbital transfer vehicle. The results are compared and the differences between the methods are discussed.

Carlson, Ann B.↗

Monte Carlo simulation of a near-continuum shock-shock interaction problem

A complex shock interaction is calculated with direct simulation Monte Carlo (DSMC). The calculation is performed for the near-continuum flow produced when an incident shock impinges on the bow shock of a 0.1 in. radius cowl lip for freestream conditions of approximately Mach 15 and 35 km altitude. Solutions are presented both for a full finite-rate chemistry calculation and for a case with chemical reactions suppressed. In each case, both the undisturbed flow about the cowl lip and the full shock interaction flowfields are calculated. Good agreement has been obtained between the no-chemistry simulation of the undisturbed flow and a perfect gas solution obtained with the viscous shock-layer method. Large differences in calculated surface properties when different chemical models are used demonstrate the necessity of adequately representing the chemistry when making surface property predictions. Preliminary grid refinement studies make it possible to estimate the accuracy of the solutions.

Carlson, Ann B.↗

Monte Carlo simulation of nitrogen dissociation based on state-resolved cross sections

State-resolved analyses of N + N{sub 2} are performed using the direct simulation Monte Carlo (DSMC) method. In describing the elastic collisions by a state-resolved method, a state-specific total cross section is proposed. The state-resolved method is constructed from the state-specific total cross section and the rovibrational state-to-state transition cross sections for bound-bound and bound-free transitions taken from a NASA database. This approach makes it possible to analyze the rotational-to-translational, vibrational-to-translational, and rotational-to-vibrational energy transfers and the chemical reactions without relying on macroscopic properties and phenomenological models. In nonequilibrium heat bath calculations, the results of present state-resolved DSMC calculations are validated with those of the master equation calculations and the existing shock-tube experimental data for bound-bound and bound-free transitions. In various equilibrium and nonequilibrium heat bath conditions and 2D cylindrical flows, the DSMC calculations by the state-resolved method are compared with those obtained with previous phenomenological DSMC models. In these previous DSMC models, the variable soft sphere, phenomenological Larsen-Borgnakke, quantum kinetic, and total collision energy models are considered. From these studies, it is concluded that the state-resolved method can accurately describe the rotational-to-translational, vibrational-to-translational, and rotational-to-vibrational transfers and quasi-steady state of rotational and vibrational energies in nonequilibrium chemical reactions by state-to-state kinetics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulations in support of the Shuttle upper atmospheric mass spectrometer experiment

This paper presents the results of calculations obtained with a Direct Simulation Monte Carlo (DSMC) method that describes both the external flow about the nose region of the Shuttle Orbiter and the internal flow in an inlet tube that provides the initial path between the shock-processed gases and a mass spectrometer mounted inside the Orbiter. A dedicated, three-dimensional version of the DSMC was developed during this study for the internal flow simulation along with the procedure for interfacing the external and internal flows. The calculations span the 140 to 95 km altitude range, which includes most of the hypersonic transitional flow encountered during reentry. All calculations were for a multicomponent gas mixture consisting of five chemical species while simulating the effects of transitional, rotational, vibrational, and chemical nonequilibrium. The results of the calculations show that within the entry region of the inlet tube where the gas has equilibrated with the sidewall tube temperature, the pressure is substantially less than the pressure at the external surface. This pressure correction for the entry region is significant for all conditions investigated and increases with altitude. The results highlight the structure of both the external and internal flow. Results of parametric studies show the sensitivity of the equilibrated inlet sidewall pressure to mass flow rates, gas-surface reflection model, tube side-wall temperature variations, and surface recombinations.

Moss, J. N.↗

Theoretically informed Monte Carlo simulation of liquid crystals by sampling of alignment-tensor fields

A theoretically informed coarse-grained Monte Carlo method is proposed for studying liquid crystals. The free energy functional of the system is described in the framework of the Landau-de Gennes formalism. The alignment field and its gradients are approximated by finite differences, and the free energy is minimized through a stochastic sampling technique. The validity of the proposed method is established by comparing the results of the proposed approach to those of traditional free energy minimization techniques. Its usefulness is illustrated in the context of three systems, namely, a nematic liquid crystal confined in a slit channel, a nematic liquid crystal droplet, and a chiral liquid crystal in the bulk. It is found that for systems that exhibit multiple metastable morphologies, the proposed Monte Carlo method is generally able to identify lower free energy states that are often missed by traditional approaches. Importantly, the Monte Carlo method identifies such states from random initial configurations, thereby obviating the need for educated initial guesses that can be difficult to formulate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Reweighted Variance Estimation for Monte Carlo Eigenvalue Simulations

Monte Carlo (MC) simulation is used to solve the eigenvalue form of the Boltzmann transport equation to estimate various parameters such as fuel pin flux distributions that are crucial for the safe and efficient operation of nuclear systems (e.g., a nuclear reactor). Monte Carlo eigenvalue simulation uses a sample mean over many stationary cycles (iterations) to estimate various parameters important to nuclear systems. A variance estimate of the sample mean is often used for calculating the confidence intervals. However, MC eigenvalue simulation variance estimators that ignore the intercycle correlation underestimate the true variance of the estimated quantity. This paper presents novel data-adaptive approaches based on a simple autoregressive (AR) model and sigmoid functions to improve MC variance estimation. The standard MC sample-based variance estimator (or naïve estimator) and the spectral density–based MC variance estimator are enhanced by adding data-adaptive components that reduce their bias and improve performance. By investigating the frequency pattern of the AR(1) (order 1) model, two adaptive spectral estimators and one adaptive naïve estimator are proposed. The proposed estimators manifest superior performance when applied to three test problems compared to the standard spectral density–based estimator previously introduced by the authors. In conclusion, these new estimators are straightforward, as they use online algorithms and do not require storage of tallies from all active cycles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient Monte Carlo simulation of rarefied flow in a small nozzle

The flow of carbon dioxide through a small conical nozzle is computed using two different numerical approaches. The first of these is the direct simulation Monte Carlo method in which the physical phenomena are modeled at the molecular level. The second technique solves the Navier-Stokes equations of fluid flow. The purpose of the paper is to compare the solutions generated by these two methods for the conditions prevailing in a small, low density nozzle. The comparison between the two sets of solutions reveals only small differences. However, the flow properties in the thick viscous layer close to the nozzle at the exit plane show important deviations which have implications for the subsequent determination of the plume backflow.

Boyd, Iain D.↗

A generalized hard-sphere model for Monte Carlo simulation

A new molecular model, called the generalized hard-sphere, or GHS model, is introduced. This model contains, as a special case, the variable hard-sphere model of Bird (1981) and is capable of reproducing all of the analytic viscosity coefficients available in the literature that are derived for a variety of interaction potentials incorporating attraction and repulsion. In addition, a new procedure for determining interaction potentials in a gas mixture is outlined. Expressions needed for implementing the new model in the direct simulation Monte Carlo methods are derived. This development makes it possible to employ interaction models that have the same level of complexity as used in Navier-Stokes calculations.