Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modular Batteries”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Universal Battery Supercharger

During the course of the UBS project a dc-fast charger was developed to be used in off board high power charging stations. High efficiency is targeted to reduce the charging price for the consumer while reducing the charge time. In the meantime, the size of the converter is minimized so that it could be used in small spaces and potentially urban areas. The topology is modular, and the power level can be expanded for charging higher power vehicles like trucks and buses. During the course of this research several key technologies was developed in LESES that improve the performance of the power electronics system used in EV charger. Integrated magnetics was developed for DMCR to improve the power density as well as efficiency of the magnetic components which is one of the main bottlenecks of EV development. Triangular mode EV current conduction mode is using to perform soft switching (increase efficiency) without adding any new components to the existing topology. Passive and active damping are developed to suppress the interaction between grid and converter, stabilizing the control system. Further numerous other technical problems have been solved to pave the way for even higher performance converters in the future.

25 ENERGY STORAGE↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Study of Storage Requirements and Costs for Shaping Renewables and Nuclear Energy (FY23 Summary Report)

To decarbonize electricity generation primarily by using wind and solar resources, it is likely that additional low (or zero) carbon dioxide (CO 2 ) alternatives will be required for ensuring a reliable electricity supply. This study extends the work and modeling framework that we consolidated in FY 2022, by assessing the zero-CO 2 pathways of a Texas power system in which the availability of variable renewable energy (VRE), nuclear energy, and energy storage types (i.e., battery and thermal energy storage [TES]) are considered the sole resources available for expansion. Using the Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON) frameworks, this study investigates the market of two nuclear energy technologies (i.e., large light-water reactors [LWRs] and LWR-type small modular reactors [SMRs]) under two plausible storage coupling scenarios (i.e., electric coupling and direct thermal coupling). We also explore optimal environments for nuclear energy deployment, and identify key performance characteristics that make nuclear energy economically viable in areas with significant intermittent energy sources. Our analysis encompasses 24 cases. We model the least-cost grid systems, highlight the potential for a coupled LWR-TES approach, and utilize SMRs to achieve deep decarbonization in an affordable, technically feasible manner. We also examine seasonal variations in balancing electricity supply and demand, and account for varying performance, costs, and grid constraints. Overall, the findings of our modeling afford valuable insights for supporting future technology investment decisions in the energy sector.

25 ENERGY STORAGE↗

Polymer-Grafted Nanoparticles as All-in-One Nanoplatforms

Polymer-grafted nanoparticles (PGNPs) represent a versatile class of hybrid nanomaterials, in which nanoparticle cores and tethered polymer coronas are integrated into structurally programmable building blocks. Rapid advances in nanoparticle surface functionalization and surface-initiated polymerization have enabled increasingly precise control over the nanoparticle core composition and brush architecture, greatly expanding the accessible structural and functional landscape of PGNPs. This review summarizes recent progress in the modular design and structural regulation of PGNPs, with an emphasis on nanoparticle platforms and associated surface functionalization strategies, polymer brush synthesis and architectural control, and the structure−property relationships that govern PGNP behavior. Emerging applications are further highlighted, including additive manufacturing, self-healing materials, membrane-based gas separations, and battery-related systems, where PGNPs provide unique opportunities to couple nanoscale interfacial design with macroscopic performance. Finally, future opportunities are discussed for extending PGNP concepts to increasingly complex, multifunctional, and application-oriented hybrid materials.

functional nanocomposites↗

SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MODAQ-BB (Modular Offshore Data Acquisition System - Blackbox) [SWR-24-72]

MODAQ-BB is a compact, rapid deployment data acquisition system that can withstand water depths up to 400m. Codenamed "BlackBox" (or simply BB), since its initial purpose was to track marine assets and record vital data streams that could later be recovered in the event of a mishap - much like a traditional black box used in aviation and shipping, the name has stuck. MODAQ BlackBox is a battery-operable microcontroller platform with internal inertial sensing, GPS, satellite communications, and additional I/O (input/output) support in a depth-rated pressure enclosure. Since BB is self-contained and relatively compact, it can be quickly deployed with minimal effort. The enclosure can be clamped to a tube (such as part of a railing) or mast in a location with unobstructed view of the sky using the available clamp accessory or a common hose clamp. While BB is designed to operate unattended, users can configure what data are uploaded and the frequency of satellite transmissions. Once data are uploaded, they can be relayed to an email distribution list, the MODAQ:Web operational dashboard, or a custom destination. BB has found utility in the National Laboratory of the Rockies' (NLR's) Waterpower projects beyond its original vision and has been configured and successfully deployed in more traditional data-gathering applications where a simple, battery-operated solution was indicated. As part of the MODAQ family, BB fills a space in the spectrum of missions that can be supported that were previously impractical using the traditional MODAQ hardware architecture due to factors such as weight, size, and cost.

Raye, Robert↗

Pumped Storage Hydropower Augmented with Pressurized Air: The Ground-Level Integrated Diverse Energy Storage (GLIDES) System — GLIDES System Configurations and Use Cases

Energy storage is essential for cost-effective integration of variable renewable energy sources to support a low-carbon grid. It is also a key enabler of a modern grid infrastructure for demand management. However, several main challenges remain for different kind of energy storage technologies in grid scale deployment. Currently, the largest source of utility-scale storage and long-duration storage in the US is pumped storage hydropower (PSH). Prospect of growth in conventional PSH faces challenges that have limited its deployment over the last three decades, including high capital costs and long deployment timelines. Batteries have high energy densities and are the primary technology of choice for small-scale energy storage. Compressed air energy storage (CAES) is another large-scale energy storage technology, but there are few plants deployed worldwide. They suffer from their low round trip efficiency (RTE) due to the use of high-pressure air compressors. To address some of the challenges associated with these various storage technologies, the Ground-Level Integrated Diverse Energy Storage (GLIDES) is a modular PSH technology that was invented in 2015 at Oak Ridge National Laboratory. It utilizes gas compression to store electric energy. GLIDES stores energy by compressing gas using a liquid piston in high-pressure vessels. In doing so the vessels act as the upper reservoir in conventional PSH. Initially, the vessels are filled with gas to a prescribed pressure. To store energy, GLIDES uses a hydraulic piston pump to pump water into the pressurized vessels. As the water volume increases inside the vessels, water acts as a hydraulic piston compressing the gas on top of it. This process can be thought of as pumping water from the lower reservoir to the higher reservoir in PSH, increasing the water head. To dispatch the stored energy, the high-head water in the vessel is discharge through a high head Pelton hydraulic turbine that is connected to an electric generator. Employing high-pressure vessels enables GLIDES to reach water heads ~10-80 times higher than conventional PSH, achieving ~40 times higher energy densities, and overcomes the geographic limitation of conventional PSH. Although its energy density is much lower than that of batteries, GLIDES holds the potential advantages of having long service life, ease of system integration and being less hazardous over batteries. GLIDES prospective scalability could make it suitable for wide range of applications from behind the meter storage in buildings to grid-scale storage. It also makes it suitable for installations in densely populated urban areas where energy storage is most needed and real estate is limited. Over the last 5 years, work has focused on increasing GLIDES’ energy density, decreasing its initial capital cost of the system, and increasing its revenue potential. Several designs were developed and prototyped to verify and demonstrate the improvement in energy density. The latest prototype achieved energy density of 1.21 kWh/m 3 . Our analysis showed that it could achieve up to 1.7 kWh/m 3 with a mixture of air and carbon dioxide as the gas being compressed.

13 HYDRO ENERGY↗

PowerGridworld: A Framework for Multi-Agent Reinforcement Learning in Power Systems [SWR-22-07]

NREL's PowerGridworld provides a modular simulation environment for training heterogenous, grid-aware, multi-agent reinforcement learning (RL) policies at scale. The package enables the user to create component gym environments that can be composed into more complex agents. For example, a grid interactive building environment can be created by composing together component environments each encapsulating the building, PV, and battery physics. These multi-component environments can then be combined into multi-agent simulation where each agent's power consumption/injection becomes an input for solving the optimal power flow on a distribution feeder modeled in OpenDSS. Information from OpenDSS, such as bus voltages and line flows, can be included in the agents' observation spaces to enable grid-aware rewards. The default API for the PowerGridworld simulator conforms to RLLib's MultiAgent API and thus enables distributed training using HPC and cloud resources.

Biagioni, David↗

DERMS-RT (Distributed Energy Resource Management Solution using Real-Time Optimization) [SWR-20-46]

DERMS-RT provides a distributed energy resource management solution using real-time optimization to control different types of distributed energy resources (DERs) — such as rooftop PVs, battery energy storage systems, HVAC loads, electric water heater loads, and EV charging loads, and use these DERs to provide distribution voltage regulation and peak demand management services. The control approach implemented by DERM-RT is developed based on the real-time optimal power flow and distributed control previously developed by NREL researchers. The software codes are designed to provide modular DER management solution that can be easily applied to control heterogeneous DERs in distribution grids in coordination with centralized utility management systems. Also, DERMS-RT provides application programming interface (API) to extract useful grid model information from an open-source power system simulation software, use the information to solve the optimization problem, and apply the optimal set-points to the controlled DERs. In this way, DERMS-RT provides a plug-and-play function for implementing the real-time DER control on different utility system models, and it can be used as a simulation testbed to demonstrate the impact of real-time DER optimization on improving grid operations.

Ding, Fei↗

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY↗

A Modular Optimal Power Flow Method for Integrating New Technologies in Distribution Grids

This work proposes a modular concept to build optimal power flow (OPF) models for distribution networks containing various emerging technologies under diverse ownership structures, to efficiently deal with evolving technology capabilities and information sharing or privacy constraints. This concept will support any typical OPF application (e.g., optimal dispatch of a given asset without violating grid constraints) by coordinating between grid module and technology module without the need to recreate various modeling elements as technology capability changes due to innovation. Moreover, the modularity of the proposed concept enables achieving system level objectives without sharing detailed information on module level objectives and constraints among modules. To achieve this, the proposed work develops a gradient-descent algorithm which builds upon the literature on the state-of-the-art power flow approximation. The proposed concept is demonstrated with two case studies of i) controllable loads and ii) battery energy storage system (BESS) on an actual large-scale distribution grid.

Hanif, Sarmad↗

Carbon Capture from ArcelorMittal Hot Briquetted Iron Plant Using Air Liquide Cryocap™ FG Technology – FEED Study

The process of steel production is energy and carbon intensive with global average energy consumption of 5.5 MWh/tonne of steel and CO2 emission intensity of 1.83 tonne CO2/tonne of steel. The steel making process has inherent CO2 emissions from mineral conversion and is considered major contributors to the global carbon emissions. The steel industry is responsible for 8% of global carbon emissions. The main objective of this research project is to execute and complete a front-end engineering and design (FEED) study for a commercial-scale, carbon capture project that separates 95% of the total CO2 emissions at the ArcelorMittal’s Hot Briquetted Iron (HBI) plant in Portland, TX (Figure 1). The HBI is an ore-based metallic that is used as high-grade feedstock for high-quality steel via an Electric Arc Furnace (EAF) route. The HBI plant produces 2.0 million metric tonnes of high-quality HBI and emits approximately 1 million tonnes CO2/yr. The capture system is a Pressure Swing Adsorption (PSA) system assisted Cryocap™ FG technology (Figure 2). The captured CO2 will be pipeline grade and will be geologically stored in a facility within 10 miles of the CO2 source. The Host Site location in Corpus Christi, TX, is near hydrocarbon processing facilities and near Environmental Justice (EJ) and Qualified Opportunity Zone (QOZ) communities. Due to the location of the Host Site, the retrofit project offers the ability to demonstrate how a workforce focused on the fossil energy sector can be redirected to the clean- energy sector. The Air Liquide Cryocap™ capture technology is a proven technology and has been extensively examined for large industrial applications. It has been shown to be applicable to a variety of industrial applications including the steel industry. Cryocap™ FG (specific setup for Flue Gas application) consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The scope of this study incorporates completing FEED study of the CO2 capture system which includes point-source CO2 capture and balance-of-plant; Business Case Analysis (BCA) outlining the current and projected volumes of the steel plant’s point sources of CO2 and the potential utilization of tax credits, including its projected revenue and duration; Life Cycle Analysis (LCA); Environmental Justice Analysis; Economic Revitalization and Job Creation Outcomes Analysis; and Workforce Readiness Plan. The plant design work was divided into two components: Inside Battery Limits (ISBL) and Outside Battery Limits (OSBL). The ISBL focuses on the capture system, while the OSBL focuses on the utility feeds and ducting from the plant to the capture system. Various design and engineering deliverables will be developed to define commodity quantities, equipment specifications, and labour effort required to execute the project. These FEED study deliverables will be prepared with the intent to develop an overall project capital cost estimate consistent with an AACE Class 3 estimate. The modular approach for the Cryocap™ FG that is being designed for this study integrates compression, PSA, and cryogenic “bricks” to achieve the desired CO2 capture rates. This carbon capture system integrates easily with the existing plant, thus reducing project costs and risks. It is also capable of managing impurities such as nitrogen oxides (NOx), sulfur oxides (SOx), mercury, hydrocarbons, and particulate matter. The capture system has a smaller footprint than amine-based systems. The two-step process uses PSA to preconcentrate the CO2 in the feedstream and then uses the cryogenic portion to purify and compress the resulting high purity CO2 product. This combination of purification and compression (i.e., process intensification) significantly reduces the CAPEX associated with use of a separate compressor commonly utilized for amine solvent-based systems. Successful completion of the FEED study will provide DOE with a detailed understanding of the costs for scaling up this proven capture technology for commercial applications at industrial facilities.

42 ENGINEERING↗

A High-Voltage High-Reliability Scalable Architecture for Electric Vehicle Power Electronics (Final Report)

This project developed and demonstrated new composite converter technologies that lead to high power density (> 20 kW/L) at power levels of 10s of kW, 100s of kW, or possibly higher, with fundamental advances in converter efficiency and Q that lead to substantial increases in mean time to failure (MTTF). These advantages were realized through development of new composite converter topologies that perform buck, boost, or other conversion functions and that are scalable to higher voltage and power levels through sharing of voltage and current stresses among multiple dissimilar partial-power converter modules. The project led to experimental demonstration of a125 kW multifunction electric vehicle power conversion system having in-creased dc bus voltage (950 V nominal, 1200 V peak) that interfaces a 200 V to 400 V battery pack, and that includes integrated level 2 wired charging and wireless charging functions. The project incorporated SiC MOSFET modules having switching frequencies in excess of 100 kHz, planar magnetics, a hierarchical control architecture that enables scaling to higher voltages and powers with additional converter modules, and a high-power density in excess of 20 kW/L. The research demonstrated how a more complex converter approach can increase mean-time-to-failure, even though the number of elements is increased. This is achieved through significant reduction of temperature rise through fundamentally superior converter circuit topologies. The research also demonstrated new high power planar magnetics that increase power density. The technology is appropriate to a variety of applications including EV power trains, EV charging, PV inverters, battery storage, and similar areas. These systems potentially can be manufactured in the U.S.

33 ADVANCED PROPULSION SYSTEMS↗

Development and Demonstration of Medium-Heavy Duty PHEV Work Trucks

The heavy-duty vehicle market (Class 6-8) has been a difficult segment for the introduction of plug-in vehicles due to the large energy storage requirement (with corresponding cost), challenging duty cycles, and the diversity of vehicle configurations. The Work Truck market represents a significant opportunity for Heavy-Duty PHEV adoption. (1) The usage cycle includes driving and stationary/worksite power requirements, ensuring full daily usage of the grid-charged battery (battery size: 15-30kWhr). Though daily driving can often be short (an average of 26 miles per day), worksite power includes substantial demand (hydraulics, exportable 110/220V power, 12V support, HVAC). (2) Worksite power demands for conventional vehicles require continuous loaded engine operation, resulting in significant emissions, fuel consumption and noise impacts. (3) These trucks serve an industry that is highly diverse in final vehicle duty cycle, configuration, and jobsite power demands resulting in the need for a modular, configurable hybrid solution. Through this program, Odyne has developed and demonstrated a medium/heavy duty plug-in hybrid solution capable of meeting the needs of the work truck market while delivering fuel and emissions reductions of 50% or greater when evaluated against the full-day work truck duty cycle. The Odyne system developed in this project was released for commercial sale as the G2V7 Odyne Plug-in Hybrid and ePTO systems. The testing and field demonstration proved that the Odyne hybrid system is capable of reducing work truck fuel use and emissions by over 50% while subsequent commercial sales demonstrate the flexibility of the modular design and the capability to support electric systems of 12 – 30 kW and hydraulic based systems of 60 kW (80 HP) or greater. Odyne is continuing to work with suppliers on reducing component costs and working with supporting agencies to initiate projects to increase the driving and full day fuel and emissions savings in order to continue to improve the customer value and return on investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Multiport DC Transformer to Enable Flexible Scalable DC as a Service

The rapid adoption of new DC loads and sources, including photovoltaic arrays, DC fast charging of electric vehicle, battery energy storage and data centers, requires a large amount of DC power conversion. A majority of new deployments also necessitate the integration of multiple DC loads and sources at one site. The traditional approach to serve these new applications relies on multiple standard power converters, each dedicated to a source or load, and results in highly customized systems, with challenging control coordination, complex protection strategies, and poor scalability. Instead, this paper proposes the concept of a multiport DC transformer (MDCT) as a modular building block for realizing a flexible, scalable DC as a Service system and address this rapidly growing need. The MDCT uses the S4T to achieve very tight control of cycle-by-cycle energy exchange between multiple ports, with high efficiency. A single multiport converter replaces 4-6 distinct converters, integrates all energy flows and manages protection. As a result, a new layered control architecture is introduced to ensure stability and scalability of the MDCT, with multiple S4T power converter building blocks connected in parallel to realize a fully modular system and reach the target power levels.

30 DIRECT ENERGY CONVERSION↗

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗