Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Clean surface processing of rubrene single crystal immersed in ionic liquid by using frequency modulation atomic force microscopy

Surface processing of a rubrene single crystal immersed in ionic liquids is valuable for further development of low voltage transistors operated by an electric double layer. We performed a precise and clean surface processing based on the tip-induced dissolution of rubrene molecules at the ionic liquid/rubrene single crystal interfaces by using frequency modulation atomic force microscopy. Molecular resolution imaging revealed that the tip-induced dissolution proceeded via metastable low density states derived from the anisotropic intermolecular interactions within the crystal structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Local impedance measurement of an electrode/single-pentacene-grain interface by frequency-modulation scanning impedance microscopy

The device performances of organic thin film transistors are often limited by the metal–organic interface because of the disordered molecular layers at the interface and the energy barriers against the carrier injection. It is important to study the local impedance at the interface without being affected by the interface morphology. We combined frequency modulation atomic force microscopy with scanning impedance microscopy (SIM) to sensitively measure the ac responses of the interface to an ac voltage applied across the interface and the dc potential drop at the interface. By using the frequency-modulation SIM (FM-SIM) technique, we characterized the interface impedance of a Pt electrode and a single pentacene grain as a parallel circuit of a contact resistance and a capacitance. We found that the reduction of the contact resistance was caused by the reduction of the energy level mismatch at the interface by the FM-SIM measurements, demonstrating the usefulness of the FM-SIM technique for investigation of the local interface impedance without being affected by its morphology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tip radius preservation for high resolution imaging in amplitude modulation atomic force microscopy

The acquisition of high resolution images in atomic force microscopy (AFM) is correlated to the cantilever's tip shape, size, and imaging conditions. In this work, relative tip wear is quantified based on the evolution of a direct experimental observable in amplitude modulation atomic force microscopy, i.e., the critical amplitude. We further show that the scanning parameters required to guarantee a maximum compressive stress that is lower than the yield/fracture stress of the tip can be estimated via experimental observables. In both counts, the optimized parameters to acquire AFM images while preserving the tip are discussed. The results are validated experimentally by employing IgG antibodies as a model system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Autopilot for frequency-modulation atomic force microscopy

One of the most challenging aspects of operating an atomic force microscope (AFM) is finding optimal feedback parameters. This statement applies particularly to frequency-modulation AFM (FM-AFM), which utilizes three feedback loops to control the cantilever excitation amplitude, cantilever excitation frequency, and z-piezo extension. These loops are regulated by a set of feedback parameters, tuned by the user to optimize stability, sensitivity, and noise in the imaging process. Optimization of these parameters is difficult due to the coupling between the frequency and z-piezo feedback loops by the non-linear tip-sample interaction. Four proportional-integral (PI) parameters and two lock-in parameters regulating these loops require simultaneous optimization in the presence of a varying unknown tip-sample coupling. Presently, this optimization is done manually in a tedious process of trial and error. Here, we report on the development and implementation of an algorithm that computes the control parameters automatically. The algorithm reads the unperturbed cantilever resonance frequency, its quality factor, and the z-piezo driving signal power spectral density. It analyzes the poles and zeros of the total closed loop transfer function, extracts the unknown tip-sample transfer function, and finds four PI parameters and two lock-in parameters for the frequency and z-piezo control loops that optimize the bandwidth and step response of the total system. Implementation of the algorithm in a home-built AFM shows that the calculated parameters are consistently excellent and rarely require further tweaking by the user. The new algorithm saves the precious time of experienced users, facilitates utilization of FM-AFM by casual users, and removes the main hurdle on the way to fully automated FM-AFM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated force controller for amplitude modulation atomic force microscopy

Atomic Force Microscopy (AFM) is widely used in physics, chemistry, and biology to analyze the topography of a sample at nanometer resolution. Controlling precisely the force applied by the AFM tip to the sample is a prerequisite for faithful and reproducible imaging. In amplitude modulation (oscillating) mode AFM, the applied force depends on the free and the setpoint amplitudes of the cantilever oscillation. Therefore, for keeping the applied force constant, not only the setpoint amplitude but also the free amplitude must be kept constant. While the AFM user defines the setpoint amplitude, the free amplitude is typically subject to uncontrollable drift, and hence, unfortunately, the real applied force is permanently drifting during an experiment. This is particularly harmful in biological sciences where increased force destroys the soft biological matter. Here, we have developed a strategy and an electronic circuit that analyzes permanently the free amplitude of oscillation and readjusts the excitation to maintain the free amplitude constant. As a consequence, the real applied force is permanently and automatically controlled with picoNewton precision. With this circuit associated to a high-speed AFM, we illustrate the power of the development through imaging over long-duration and at various forces. The development is applicable for all AFMs and will widen the applicability of AFM to a larger range of samples and to a larger range of (non-specialist) users. Furthermore, from controlled force imaging experiments, the interaction strength between biomolecules can be analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostrictive and electrostatic responses in contact mode voltage modulated Scanning Probe Microscopies

Electromechanical response of solids underpins image formation mechanism of several scanning probe microscopy techniques including the piezoresponse force microscopy (PFM) and electrochemical strain microscopy (ESM). While the theory of linear piezoelectric and ionic responses are well developed, the contributions of quadratic effects including electrostriction and capacitive tip-surface forces to measured signal remain poorly understood. Here we analyze the electrostrictive and capacitive contributions to the PFM and ESM signals and discuss the implications of the dielectric tip-surface gap on these interactions.

Eliseev, E. A.↗

Phase contrast and operation regimes in multifrequency atomic force microscopy

In amplitude modulation atomic force microscopy the attractive and the repulsive force regimes induce phase shifts above and below 90°, respectively. In the more recent multifrequency approach, however, multiple operation regimes have been reported and the theory should be revisited. Here, a theory of phase contrast in multifrequency atomic force microscopy is developed and discussed in terms of energy transfer between modes, energy dissipation and the kinetic energy and energy transfer associated with externally driven harmonics. The single frequency virial that controls the phase shift might undergo transitions in sign while the average force (modal virial) remains positive (negative)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superresolved multiphoton microscopy with spatial frequency-modulated imaging

Superresolved far-field microscopy has emerged as a powerful tool for investigating the structure of objects with resolution well below the diffraction limit of light. Nearly all superresolution imaging techniques reported to date rely on real energy states of fluorescent molecules to circumvent the diffraction limit, preventing superresolved imaging with contrast mechanisms that occur via virtual energy states, including harmonic generation (HG). Here, we report a superresolution technique based on spatial frequency-modulated imaging (SPIFI) that permits superresolved nonlinear microscopy with any contrast mechanism and with single-pixel detection. We show multimodal superresolved images with two-photon excited fluorescence (TPEF) and second-harmonic generation (SHG) from biological and inorganic media. Multiphoton SPIFI (MP-SPIFI) provides spatial resolution up to 2η below the diffraction limit, where η is the highest power of the nonlinear intensity response. MP-SPIFI can be used to provide enhanced resolution in optically thin media and may provide a solution for superresolved imaging deep in scattering media.

36 MATERIALS SCIENCE↗

Determination of the microstructure of gas bubbles in highly purified water by measuring the elements of the laser radiation scattering matrix

Modulation interference microscopy and measurements of the elements of the light scattering matrix showed that doubly distilled water purified from solid impurities contains macroscopic scatterers in the form of micron clusters formed by polydisperse air bubbles with the effective radius 70-90 nm. The fractal dimension of clusters lies within 2.4-2.8 and their concentration is {approx}10{sup 6} cm{sup -3}. (radiation scattering)

36 MATERIALS SCIENCE↗

Multicolor multifocal 3D microscopy using in-situ optimization of a spatial light modulator

Abstract Multifocal microscopy enables high-speed three-dimensional (3D) volume imaging by using a multifocal grating in the emission path. This grating is typically designed to afford a uniform illumination of multifocal subimages for a single emission wavelength. Using the same grating for multicolor imaging results in non-uniform subimage intensities in emission wavelengths for which the grating is not designed. This has restricted multifocal microscopy applications for samples having multicolored fluorophores. In this paper, we present a multicolor multifocal microscope implementation which uses a Spatial Light Modulator (SLM) as a single multifocal grating to realize near-uniform multifocal subimage intensities across multiple wavelength emission bands. Using real-time control of an in-situ-optimized SLM implemented as a multifocal grating, we demonstrate multicolor multifocal 3D imaging over three emission bands by imaging multicolored particles as well as Escherichia coli ( E. coli ) interacting with human liver cancer cells, at $$\sim 2.5$$ ∼ 2.5 multicolor 3D volumes per second acquisition speed. Our multicolor multifocal method is adaptable across SLM hardware, emission wavelength band locations and number of emission bands, making it particularly suited for researchers investigating fast processes occurring across a volume where multiple species are involved.

47 OTHER INSTRUMENTATION↗

Phase modulation mode of scanning ion conductance microscopy

This Letter reports a phase modulation (PM) mode of scanning ion conductance microscopy. In this mode, an AC current is directly generated by an AC voltage between the electrodes. The portion of the AC current in phase with the AC voltage, which is the current through the resistance path, is modulated by the tip-sample distance. It can be used as the input of feedback control to drive the scanner in Z direction. The PM mode, taking the advantages of both DC mode and traditional AC mode, is less prone to electronic noise and DC drift but maintains high scanning speed. The effectiveness of the PM mode has been proven by experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Largely defocused probe scanning transmission electron microscopy for imaging local modulation of strain field in a hetero interface

We present an innovative method for characterizing the strain field in three dimensions in a hetero interface. Largely defocused probe scanning transmission electron microscopy (LDP-STEM) was employed for imaging the inhomogeneous strain field in a germanium (Ge) layer deposited on a silicon (Si) substrate. In the LDP-STEM image, Ge-atomic columns that are relaxed or strained to the Si substrate in the Si/Ge hetero interface were observed to be distinguishable, allowing for the qualitative characterization of the coherency of the crystal growth. Our results revealed that the strain field is locally modulated along the in-plane direction in the Si/Ge hetero interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Biomineralization of a Self-Assembled Extracellular Matrix for Bone Tissue Engineering

Understanding how biomineralization occurs in the extracellular matrix (ECM) of bone cells is crucial to the understanding of bone formation and the development of a successfully engineered bone tissue scaffold. It is still unclear how ECM mechanical properties affect protein-mineral interactions in early stages of bone mineralization. We investigated the longitudinal mineralization properties of MC3T3-E1 cells and the elastic modulus of their ECM using shear modulation force microscopy, synchrotron grazing incidence X-ray diffraction (GIXD), scanning electron microscopy, energy dispersive X-ray spectroscopy, and confocal laser scanning microscopy (CLSM). The elastic modulus of the ECM fibers underwent significant changes for the mineralizing cells, which were not observed in the nonmineralizing cells. On substrates conducive to ECM network production, the elastic modulus of mineralizing cells increased at time points corresponding to mineral production, whereas that of the nonmineralizing cells did not vary over time. The presence of hydroxyapatite in mineralizing cells and the absence thereof in the nonmineralizing ones were confirmed by GIXD, and CLSM showed that a restructuring of actin occurred only for mineral-producing cells. These results show that the correct and complete development of the ECM network is required for osteoblasts to mineralize. This in turn requires a suitably prepared synthetic substrate for bone development to succeed in vitro.

43 PARTICLE ACCELERATORS↗

Electrochemically modulated single-molecule localization microscopy for in vitro imaging cytoskeletal protein structures

A new concept of electrochemically modulated single-molecule localization super-resolution imaging is developed. Applications of single-molecule localization super-resolution microscopy have been limited due to insufficient availability of qualified fluorophores with favorable low duty cycles. The key for the new concept is that the “On” state of a redox-active fluorophore with unfavorable high duty cycle could be driven to “Off” state by electrochemical potential modulation and thus become available for single-molecule localization imaging. The new concept was carried out using redox-active cresyl violet with unfavorable high duty cycle as a model fluorophore by synchronizing electrochemical potential scanning with a single-molecule localization microscope. The two cytoskeletal protein structures, the microtubules from porcine brain and the actins from rabbit muscle, were selected as the model target structures for the conceptual imaging in vitro. The super-resolution images of microtubules and actins were obtained from precise single-molecule localizations determined by modulating the On/Off states of single fluorophore molecules on the cytoskeletal proteins via electrochemical potential scanning. Importantly, this method could allow more fluorophores even with unfavorable photophysical properties to become available for a wider and more extensive application of single-molecule localization microscopy.

electrochemical modulation↗