At least 73 records · Page 4

Picosecond wide-field time-correlated single photon counting fluorescence microscopy with a delay line anode detector

We perform wide-field time-correlated single photon counting-based fluorescence lifetime imaging (FLIM) with a crossed delay line anode image intensifier, where the pulse propagation time yields the photon position. This microchannel plate-based detector was read out with conventional fast timing electronics and mounted on a fluorescence microscope with total internal reflection (TIR) illumination. The picosecond time resolution of this detection system combines low illumination intensity of microwatts with wide-field data collection. This is ideal for fluorescence lifetime imaging of cell membranes using TIR. We show that fluorescence lifetime images of living HeLa cells stained with membrane dye di-4-ANEPPDHQ exhibit a reduced lifetime near the coverslip in TIR compared to epifluorescence FLIM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative displacement measurement of a nanotube cantilever with nanometer accuracy using epifluorescence microscopy

A method to measure the deflection of a nanotube cantilever with nanometer accuracy in an air or liquid environment is presented. We attached fluorescent dyes at the end of a nanotube to detect its deflection. The nanotube cantilever was fabricated with a multiwalled carbon nanotube that is attached to the end of an electrochemically etched tungsten tip, and it was imaged in an epifluorescence microscope system. The fluorescence intensity distribution of the fluorescent particles at the end of the nanotube was approximated with a Gaussian and fitted by least-squares method. Finally, we were able to measure the displacement of the nanotube cantilever during electrostatic actuation with positional accuracy of a few nanometers. This technique can be applied to a manipulator or a force transducer on related a few piconewton forces.

42 ENGINEERING↗

Zone-Doubling Technique to Produce Ultrahigh-Resolution X-Ray Optics

A method for the fabrication of ultrahigh-resolution Fresnel zone plate lenses for x-ray microscopy is demonstrated. It is based on the deposition of a zone plate material (Ir) onto the sidewalls of a prepatterned template structure (Si) using an atomic layer deposition technique. This results in a doubling of the effective zone density, thus improving the achievable resolution of x-ray microscopes. Test structures with lines and spaces down to 15 nm were resolved in a scanning transmission x-ray microscope at 1 keV photon energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Super-resolution microscopy reveals protein spatial reorganization in early innate immune responses.

Over the past decade optical approaches were introduced that effectively break the diffraction barrier. Of particular note were introductions of Stimulated Emission/Depletion (STED) microscopy, Photo-Activated Localization Microscopy (PALM), and the closely related Stochastic Optical Reconstruction Microscopy (STORM). STORM represents an attractive method for researchers, as it does not require highly specialized optical setups, can be implemented using commercially available dyes, and is more easily amenable to multicolor imaging. We implemented a simultaneous dual-color, direct-STORM imaging system through the use of an objective-based TIRF microscope and filter-based image splitter. This system allows for excitation and detection of two fluorophors simultaneously, via projection of each fluorophor's signal onto separate regions of a detector. We imaged the sub-resolution organization of the TLR4 receptor, a key mediator of innate immune response, after challenge with lipopolysaccharide (LPS), a bacteria-specific antigen. While distinct forms of LPS have evolved among various bacteria, only some LPS variations (such as that derived from E. coli) typically result in significant cellular immune response. Others (such as from the plague bacteria Y. pestis) do not, despite affinity to TLR4. We will show that challenge with LPS antigens produces a statistically significant increase in TLR4 receptor clusters on the cell membrane, presumably due to recruitment of receptors to lipid rafts. These changes, however, are only detectable below the diffraction limit and are not evident using conventional imaging methods. Furthermore, we will compare the spatiotemporal behavior of TLR4 receptors in response to different LPS chemotypes in order to elucidate possible routes by which pathogens such as Y. pestis are able to circumvent the innate immune system. Finally, we will exploit the dual-color STORM capabilities to simultaneously image LPS and TLR4 receptors in the cellular membrane at resolutions at or below 40nm.

59 BASIC BIOLOGICAL SCIENCES↗

Photon flux requirements for EUV reticle imaging microscopy in the 22 and 16 nm nodes

EUV-wavelength actinic microscopy yields detailed information about EUV mask patterns, architectures, defects, and the performance of defect repair strategies, without the complications of photoresist imaging. The measured aerial image intensity profiles provide valuable feedback to improve mask and lithography system modeling methods. In order to understand the photon-flux-dependent pattern measurement limits of EUV mask-imaging microscopy, we have investigated the effects of shot noise on aerial image linewidth measurements for lines in the 22 and 16-nm generations. Using a simple model of image formation near the resolution limit, we probe the influence of photon shot noise on the measured, apparent line roughness. With this methodology, we arrive at general flux density requirements independent of the specific EUV microscope configurations. Analytical and statistical analysis of aerial image simulations in the 22 and 16-nm generations reveal the trade-offs between photon energy density (controllable with exposure time), effective pixel dimension on the CCO (controlled by the microscope's magnification ratio), and image log slope (ILS). We find that shot-noise-induced linewidth roughness (LWR) varies imersely with the square root of the photon energy density, and is proportional to the imaging magnification ratio. While high magnification is necessary for adequate spatial resolution, for a given flux density, higher magnification ratios have diminishing benefits. With practical imaging parameters, we find that in order to achieve an LWR (3{sigma}) value of 5% of linewidth for dense, 88-nm mask features with 80% aerial image contrast and 13.5-nm effective pixel width (1000x magnification ratio), a peak photon flux of approximately 1400 photons per pixel per exposure is required.

36 MATERIALS SCIENCE↗

A simple approach to neutral atom microscopy

Scanning surfaces using a beam of noncharged atoms or molecules allows for especially nondestructive and low-energy surface imaging, with the potential to obtain new information about surfaces that cannot be easily obtained otherwise. We have developed a new approach, operating with the sample at a close working distance from an aperture, the need for optics to focus the beam is obviated. Compared to more complex approaches, the theoretical performance has no other disadvantage than the short working distance. Resolution of 1.5 {mu}m has been achieved, and submicron resolution appears to be practical. Construction of the microscope and results are presented, including first images done in reflection mode, theory for optimization of the design and avenues for future improvement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic x-ray microscopy at low temperatures – Visualization of flux distributions in superconductors

X-ray Magnetic Circular Dichroism (XMCD) microscopy at liquid nitrogen temperature has been performed on bilayers of high-T{sub c} superconducting YBCO (YBa{sub 2}Cu{sub 3}O{sub 7-δ}) and soft-magnetic Co{sub 40}Fe{sub 40}B{sub 20}. This should allow us to map the magnetic flux density distribution in the current-carrying state of the superconductor with high spatial resolution. For that purpose the UHV scanning X-ray microscope MAXYMUS has been upgraded by a MMR Micro Miniature Joule-Thompson cryostat capable of temperatures between 75 K and 580 K. Resulting XMCD images of the magnetic flux density in the superconductor with a field of view ranging from millimeters to micrometers are presented. The microscope’s unique combination of total electron yield (TEY) measurements together with low temperatures offers novel possibilities concerning the current transport in superconductors on small length scales.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PROTON MICROSCOPY AT FAIR

Proton radiography was invented in the 1990's at Los Alamos National Laboratory (LANL) as a diagnostic to study dynamic material properties under extreme pressures, strain and strain rate. Since this time hundreds of dynamic proton radiography experiments have been performed at LANL and a facility has been commissioned at the Institute for Theoretical and Experimental Physics (ITEP) in Russia for similar applications in dynamic material studies. Recently an international effort has investigated a new proton radiography capability for the study of dynamic material properties at the Facility for Anti-proton and Ion Research (FAIR) located in Darmstadt, Germany. This new Proton microscope for FAIR(PRIOR) will provide radiographic imaging of dynamic systems with unprecedented spatial, temporal and density resolution, resulting in a window for understanding dynamic material properties at new length scales. It is also proposed to install the PRIOR system at the GSI Helmholtzzentrum fuer Schwerionenforschung before installation at FAIR for dynamic experiments with different drivers including high explosives, pulsed power and lasers. The design of the proton microscope and expected radiographic performance is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Glass Monocapillary X-ray Optics And Their Applications In X-ray Microscopy

Elliptical, parabolic and Wolter type glass monocapillaries were fabricated for use as x-ray condensers in the energy range of 250 eV to 20 keV. On a routine basis a diameter error of +/-0.4 {mu}m and straightness error of 0.8 {mu}m (peak to valley) can be reached. The final test of condensers was performed at-wavelength by imaging the far field x-ray reflection intensity distribution using a laboratory microfocus x-ray source. For medium length condensers with a total length <80 mm, a total slope error of 40 murad rms was obtained. The applications in full-field x-ray microscopes and the future effort in developing capillary Wolter mirrors based on this technology are reported.

07 ISOTOPE AND RADIATION SOURCES↗

Improving the performance of the actinic inspection tool with an optimized alignment procedure

Extreme ultraviolet (EUV) microscopy is an important tool for the investigation of the performance of EUV masks, for detecting the presence and the characteristics of defects, and for evaluating the effectiveness of defect repair techniques. Aerial image measurement bypasses the difficulties inherent to photoresist imaging and enables high data collection speed and flexibility. It provides reliable and quick feedback for the development of masks and lithography system modeling methods. We operate the SEMATECH Berkeley Actinic Inspection Tool (AIT), a EUV microscope installed at the Advanced Light Source at Lawrence Berkeley National Laboratory. The AIT is equipped with several high-magnification Fresnel zoneplate lenses, with various numerical aperture values, that enable it image the reflective mask surface with various resolution and magnification settings. Although the AIT has undergone significant recent improvements in terms of imaging resolution and illumination uniformity, there is still room for improvement. In the AIT, an off-axis zoneplate lens collects the light coming from the sample and an image of the sample is projected onto an EUV-sensitive CCD camera. The simplicity of the optical system is particularly helpful considering that the AIT alignment has to be performed every time that a sample or a zoneplate is replaced. The alignment is sensitive to several parameters such as the lens position and orientation, the illumination direction and the sample characteristics. Since the AIT works in high vacuum, there is no direct access to the optics or to the sample during the alignment and the measurements. For all these reasons the alignment procedures and feedback can be complex, and in some cases can reduce the overall data throughput of the system. In this paper we review the main strategies and procedures that have been developed for quick and reliable alignments, and we describe the performance improvements we have achieved, in terms of aberration magnitude reduction.

36 MATERIALS SCIENCE↗

Proton microscopy at GSI and FAIR

Proton radiography was invented in the 1990's at Los Alamos National Laboratory (LANL) as a diagnostic to study dynamic material properties under extreme pressures, strain and strain rate. Since this time hundreds of dynamic proton radiography experiments have been performed at LANL and facilities have been commissioned at the Institute for Theoretical and Experimental Physics (ITEP) in Russia for similar applications in dynamic material studies. Recently an international collaboration was formed to develop a new proton radiography capability for the study of dynamic material properties at the Facility for Anti-proton and Ion Research (FAIR) located at Gesellschaft fuer Schwerionenforschung (GSI) in Darmstadt, Germany. This new Proton microscope for FAIR (PRIOR) will provide radiographic imaging of dynamic systems with unprecedented spatial, temporal and density resolution, resulting in a window for understanding dynamic material properties at new length scales. These dynamic experiments will be driven with many energy sources including heavy ions, high explosives and lasers. The design of the proton microscope and expected radiographic performance is presented.

42 ENGINEERING↗

Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT

This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Polychromatic X-ray Microdiffraction Characterization of Local Crystallographic Structure and Defect Distributions

Three-dimensional (3D), nondestructive, spatially resolved characterization of local crystal structure is conveniently made with polychromatic x-ray microdiffraction. In general, polychromatic microdiffraction provides information about the local (subgrain) orientation, unpaired-dislocation density, and elastic strain. This information can be used for direct comparison to theoretical models. Practical microbeams use intense synchrotron x-ray sources and advanced x-ray focusing optics. By employing polychromatic x-ray beams and a virtual pinhole camera method, called differential aperture microscopy, 3D distributions of the local crystalline phase, orientation (texture), and elastic and plastic strain tensors can be measured with submicron 3D resolution. The local elastic strain tensor elements can typically be determined with uncertainties less than 100 ppm. Orientations can be quantified to {approx} 0.01{sup o} and the local unpaired dislocation-density tensor can be simultaneously characterized. The spatial resolution limit for hard x-ray polychromatic microdiffraction is < 40nm and existing instruments operate with {approx} 500 to 1000nm resolution. Because the 3D x-ray crystal microscope is a penetrating nondestructive tool, it is ideal for studies of mesoscale evolution in materials.

36 MATERIALS SCIENCE↗

Tutorial: Crystal orientations and EBSD — Or which way is up?

Electron backscatter diffraction (EBSD) is an automated technique that can measure the orientation of crystals in a sample very rapidly. There are many sophisticated software packages that present measured data. Unfortunately, due to crystal symmetry and differences in the set-up of microscope and EBSD software, there may be accuracy issues when linking the crystal orientation to a particular microstructural feature. In this paper we outline a series of conventions used to describe crystal orientations and coordinate systems. These conventions have been used to successfully demonstrate that a consistent frame of reference is used in the sample, unit cell, pole figure and diffraction pattern frames of reference. We establish a coordinate system rooted in measurement of the diffraction pattern and subsequently link this to all other coordinate systems. A fundamental outcome of this analysis is to note that the beamshift coordinate system needs to be precisely defined for consistent 3D microstructure analysis. This is supported through a series of case studies examining particular features of the microscope settings and/or unambiguous crystallographic features. These case studies can be generated easily in most laboratories and represent an opportunity to demonstrate confidence in use of recorded orientation data. Finally, we include a simple software tool, written in both MATLAB® and Python, which the reader can use to compare consistency with their own microscope set-up and which may act as a springboard for further offline analysis. - Highlights: • Presentation of conventions used to describe crystal orientations • Three case studies that outline how conventions are consistent • Demonstrates a pathway for calibration and validation of EBSD based orientation measurements • EBSD computer code supplied for validation by the reader.

36 MATERIALS SCIENCE↗

Effects of spaceflight in the adductor longus muscle of rats flown in the Soviet Biosatellite COSMOS 2044. A study employing neural cell adhesion molecule (N-CAM) immunocytochemistry and conventional morphological techniques (light and electron microscopy)

The effects of spaceflight upon the "slow" muscle adductor longus were examined in rats flown in the Soviet Biosatellite COSMOS 2044. The techniques employed included standard methods for light microscopy, neural cell adhesion molecule (N-CAM) immunocytochemistry and electron microscopy. Light microscopic observations revealed myofiber atrophy and segmental necrosis accompanied by cellular infiltrates composed of macrophages, leukocytes and mononuclear cells. Neural cell adhesion molecule immunoreactivity (N-CAM-IR) was seen on the myofiber surface and in regenerating myofibers. Ultrastructural alterations included Z band streaming, disorganization of myofibrillar architecture, sarcoplasmic degradation, extensive segmental necrosis with apparent preservation of the basement membrane, degenerative phenomena of the capillary endothelium and cellular invasion of necrotic areas. Regenerating myofibers were identified by the presence of increased amounts of ribosomal aggregates and chains of polyribosomes associated with myofilaments. The principal electron microscopic changes of the neuromuscular junctions showed axon terminals with a decrease or absence of synaptic vesicles replaced by microtubules and neurofilaments, degeneration of axon terminals, vacant axonal spaces and changes suggestive of axonal sprouting. The present observations suggest that alterations such as myofibrillar disruption and necrosis, muscle regeneration and denervation and synaptic remodeling at the level of the neuromuscular junction may take place during spaceflight.

NASA Experiment Number COS 2044-10↗

Bacterial invasion reconstructed molecule by molecule

We propose to visualize the initial stages of bacterial infection of a human host cell with unmatched spatial and temporal resolution. This work will develop a new capability for the laboratory (super-resolution optical imaging), will test unresolved scientific hypotheses regarding host-pathogen interaction dynamics, and leverages state of the art 3D molecular tracking instrumentation developed recently by our group. There is much to be gained by applying new single molecule tools to the important and familiar problem of pathogen entry into a host cell. For example, conventional fluorescence microscopy has identified key host receptors, such as CD44 and {alpha}5{beta}1 integrin, that aggregate near the site of Salmonella typhimurium infection of human cells. However, due to the small size of the bacteria ({approx} 2 {micro}m) and the diffraction of the emitted light, one just sees a fluorescent 'blob' of host receptors that aggregate at the site of attachment, making it difficult to determine the exact number of receptors present or whether there is any particular spatial arrangement of the receptors that facilitates bacterial adhesion/entry. Using newly developed single molecule based super-resolution imaging methods, we will visualize how host receptors are directed to the site of pathogen adhesion and whether host receptors adopt a specific spatial arrangement for successful infection. Furthermore, we will employ our 3D molecular tracking methods to follow the injection of virulence proteins, or effectors, into the host cell by the pathogen Type III secretion system (TTSS). We expect these studies to provide mechanistic insights into the early events of pathogen infection that have here-to-fore been technically beyond our reach. Our Research Goals are: Goal 1--Construct a super-resolution fluorescence microscope and use this new capability to image the spatial distribution of different host receptors (e.g. CD44, as {alpha}5{beta}1 integrin) at the point of bacterial attachment to a human cell. Goal 2--Determine if the transport method of host cell receptors to the site of Salmonella infection depends upon their initial spatial location. We hypothesize that host receptors originally near the infection site will diffuse in the host membrane till 'caught' by the bacteria, while receptors further away from the bacteria will be driven by actin to the infection site in a highly directed fashion. Goal 3--Measure the 3D path taken by a bacterial effector to find its host counterpart. We hypothesize that bacterial effectors, after passing into the host via the TTSS, fmd their host target proteins through an un-biased diffusion process (e.g. a random walk, rather than active transport). This hypothesis will be tested on the bacterial effector SopE as it searches for its host partner, Racl.

36 MATERIALS SCIENCE↗

Investigations of γ′, γ″ and δ precipitates in heat-treated Inconel 718 alloy fabricated by selective laser melting

Highlights: • The γ austenite matrix shows a fine cellular substructure. • γ′ and three variants of γ″ precipitates around 10–50 nm develop within cellular γ. • Coarser acicular γ″ and plate-like δ occur at grain boundaries and intragranular γ. • The orientation relationships of γ″ with γ, and of δ with γ are observed. - Abstract: Inconel 718 alloy samples were fabricated by selective laser melting (SLM). Microstructure and precipitation in solution-heat-treated- and double-aging-SLM-made Inconel 718 were studied by scanning and transmission electron microscopy. Electron microscope observations showed that disc-shaped and cuboidal γ″, and circular γ′ precipitates with an average size of 10–50 nm developed within cellular γ austenite matrix. The simulated, experimentally observed electron diffraction patterns, and dark-field imaging further revealed that the precipitation of three variants of γ″ in the γ matrix occurred. The coarser acicular γ″, and globular as well as plate-like δ phases precipitated at grain boundaries and also within the interior of austenite matrix. The morphology, distribution and crystallography of these precipitates and their formation mechanisms were analyzed and discussed.

36 MATERIALS SCIENCE↗