Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidic devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Medicine Delivery Device with Integrated Sterilization and Detection

Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. The application of semiconductor processing techniques and technologies to the problems of fluid manipulation and delivery has enabled the integration of chemical, electrical, and mechanical manipulation of samples all within a single microfluidic device. This approach has been successfully applied at JPL to the automated processing, detection, and analysis of minute quantities (parts per trillion level) of biomaterials to develop instruments for in situ exploration or extraterrestrial bodies. The same nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely high-surface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL's ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile. An additional benefit to integrating a high-surface-area template within the fluid channel of a medicine delivery device is that one can envision a number of different functional coatings that could facilitate the capture and analysis of either microbial contaminants or the medicine itself. For example, one could attach antibodies or some other binding agent with a specific affinity to the silicon nanotip template. Once a target molecule or microbe is bound to the high-surface- area template, one could use an optical analytical technique such as fluorescence or adsorption to determine the identity and potentially the concentration of the species of interest. By illuminating the bound species from the back, it may also be possible to probe only the molecules with an evanescent wave, making detection of the species from the front side of the device much simpler.

Shearn, Michael J.↗

The Gene Fitness Atlas: A Roadmap for Predicting Evolution

We developed a novel, high-throughput microfluidic device design containing “interaction zones” where progeny cell lines compete against each other allowing for accurate analysis of bacterial cell fitness. The goal of the project was to use the device for two applications: 1) gene knockout screening and 2) antibiotic resistance screening. The microfluidic platform was fabricated using photolithography and soft lithography in polydimethylsiloxane (PDMS). E.coli Keio mutants and fluorescent wildtype parent were chosen for the study. Cells were grown overnight and their loading into the devices and seeding in mother machines was optimized. For mutant screening, the least fit mutant and wildtype parent were cultured individually and then added to the microfluidic device. The mother machines which were seeded with mutant and wildtype were imaged through time lapse microscopy and the growth of cells was observed. For antibiotic screening, wildtype E.coli cells which were grown overnight were added to the device and washed with media containing the antibiotic ampicillin. The growth pattern in presence and absence of ampicillin was observed through time lapse microscopy. It was observed that over a period of four hours, both the mutant and the wildtype divided in the mother machine and pushed daughter cells out into the interaction zone. In case of the antibiotic screening experiment, the fluorescent wildtype divided both in the absence and presence of sublethal concentration of ampicillin. This study is a proof of concept demonstration of high- throughput single cell analysis of cells using a novel microfluidics device.

59 BASIC BIOLOGICAL SCIENCES↗

Mass and Momentum Transport in Microcavities for Diffusion-Dominant Cell Culture Applications

For the informed design of microfluidic devices, it is important to understand transport phenomena at the microscale. This letter outlines an analytically-driven approach to the design of rectangular microcavities extending perpendicular to a perfusion microchannel for microfluidic cell culture devices. We present equations to estimate the spatial transition from advection- to diffusion-dominant transport inside cavities as a function of the geometry and flow conditions. We also estimate the time required for molecules, such as nutrients or drugs to travel from the microchannel to a given depth into the cavity. These analytical predictions can facilitate the rational design of microfluidic devices to optimize and maintain long-term, physiologically-based culture conditions with low fluid shear stress.

Yew, Alvin G.↗

Microfluidic In-Situ Spectrophotometric Approaches to Tackle Actinides Analysis in Multiple Oxidation States

The study and development of present and future processes for the treatment/recycling of spent nuclear fuels require many steps, from design in the laboratory to setting up on an industrial scale. In all of these steps, analysis and instrumentation are key points. For scientific reasons (small-scale studies, control of phenomena, etc.) but also with regard to minimizing costs, risks, and waste, such developments are increasingly carried out on milli- or microfluidic devices. The logic is the same for the chemical analyses associated with their follow-up and interpretation. Due to this, over the last few years, opto–microfluidic analysis devices adapted to the monitoring of different processes (dissolution, liquid–liquid extraction, precipitation, etc.) have been increasingly designed and developed. In this work, we prove that photonic lab-on-a-chip (PhLoC) technology is fully suitable for all actinides concentration monitoring along the plutonium uranium refining extraction (plutonium, uranium, reduction, extraction, or Purex) process. Several PhLoC microfluidic platforms were specifically designed and used in different nuclear research and development (R&D) laboratories, to tackle actinides analysis in multiple oxidation states even in mixtures. The detection limits reached (tens of µmol·L −1 ) are fully compliant with on-line process monitoring, whereas a range of analyzable concentrations of three orders of magnitude can be covered with less than 150 µL of analyte. Finally, this work confirms the possibility and the potential of coupling Raman and ultraviolet–visible (UV–Vis) spectroscopies at the microfluidic scale, opening the perspective of measuring very complex mixtures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A sui generis whipping-instability-based self-sequencing multi-monodisperse 2D spray from an anisotropic microfluidic liquid jet device

Well-defined aerosols pave the way for versatile basic and applied research. Here, we demonstrate a unique whipping instability that generates from a high-aspect-ratio microfluidic device resulting in a unique steady-state gas-focused whipping jet (WJ) without any need for electrification. This WJ device emanates a multi-monodisperse whipping spray jet with a two-dimensional (2D) profile. We demonstrate this phenomenon based on various fluidic parameters theoretically and experimentally. The 2D WJ’s unique behavior is derived using analytical fluid dynamics to explain jet diameter, whipping regime, and spreading angle. The phenomenon is further characterized experimentally by measuring the angle with respect to the flow rate, the distances between droplets, the droplet shapes, and the reproducibility of these parameters. We also explain the precise fabrication of such inexpensive devices. Lastly, we highlight these devices’ potential use as sample environments in versatile applications ranging from cryoelectron microscopy over mass spectrometry to drug formulation and structural studies at X-ray free-electron lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Detection of Amino Acids from Bacterial Biofilms and Plant Root Exudates by Liquid Microjunction Surface-Sampling Probe Mass Spectrometry

The plant rhizosphere is a complex and dynamic chemical environment where the exchange of molecular signals between plants, microbes, and fungi drives the development of the entire biological system. Exogenous compounds in the rhizosphere are known to affect plant-microbe organization, interactions between organisms, and ultimately, growth and survivability. The function of exogenous compounds in the rhizosphere is still under much investigation, specifically with respect to their roles in plant growth and development, the assembly of the associated microbial community, and the spatiotemporal distribution of molecular components. A major challenge for spatiotemporal measurements is developing a nondisruptive and nondestructive technique capable of analyzing the exogenous compounds contained within the environment. A methodology using liquid microjunction-surface sampling probe-mass spectrometry (LMJ-SSP-MS) and microfluidic devices with attached microporous membranes was developed for in situ, spatiotemporal measurement of amino acids (AAs) from bacterial biofilms and plant roots. Exuded arginine was measured from a living Pantoea YR 343 biofilm, which resulted in a chemical image indicative of biofilm growth within the device. Spot sampling along the roots of Populus trichocarpa with the LMJ-SSP-MS resulted in the detection of 15 AAs. Of note, variation in AA concentrations across the root system was observed, indicating that exudation is not homogeneous and may be linked to local rhizosphere architecture and different biological processes along the root.

59 BASIC BIOLOGICAL SCIENCES↗

Picoliter droplet sample processing and deposition for mass spectrometry

Disclosed herein include systems, devices, and methods for droplet deposition for mass spectrometry. In some embodiments, a microfluidic device comprising wells is reversibly sealed to a mass spectrometry surface and used to deposit contents of droplets (e.g., enzymes and substrates), or products thereof, onto the mass spectrometry surface. The contents of droplets can be analyzed by laser desorption/ionization to, for example, identify a substrate of an enzyme or an enzyme capable of catalyzing a substrate to a product.

Ha, Noel↗

Scalable fabrication of an array-type fixed-target device for automated room temperature X-ray protein crystallography

X-ray crystallography is one of the leading tools to analyze the 3-D structure, and therefore, function of proteins and other biological macromolecules. Traditional methods of mounting individual crystals for X-ray diffraction analysis can be tedious and result in damage to fragile protein crystals. Furthermore, the advent of multi-crystal and serial crystallography methods explicitly require the mounting of larger numbers of crystals. To address this need, we have developed a device that facilitates the straightforward mounting of protein crystals for diffraction analysis, and that can be easily manufactured at scale. Inspired by grid-style devices that have been reported in the literature, we have developed an X-ray compatible microfluidic device that can be used to trap protein crystals in an array configuration, while also providing excellent optical transparency, a low X-ray background, and compatibility with the robotic sample handling and environmental controls used at synchrotron macromolecular crystallography beamlines. At the Stanford Synchrotron Radiation Lightsource (SSRL), these capabilities allow for fully remote-access data collection at controlled humidity conditions. Furthermore, we have demonstrated continuous manufacturing of these devices via roll-to-roll fabrication to enable cost-effective and efficient large-scale production.

chemical engineering↗

Electrochemical pH regulation in droplet microfluidics

Here we report a method for electrochemical pH regulation in microdroplets generated in a microfluidic device. The key finding is that controlled quantities of reagents can be generated electrochemically in moving microdroplets confined within a microfluidic channel. Additionally, products generated at the anode and cathode can be isolated within descendant microdroplets. Specifically, ~5 nL water-in-oil microdroplets are produced at a T-junction and then later split into two descendant droplets. During splitting, floor-patterned microelectrodes drive water electrolysis within the aqueous microdroplets to produce H + and OH - . This results in a change in the pHs of the descendant droplets. The droplet pH can be regulated over a range of 5.9 to 7.7 by injecting controlled amounts of charge into the droplets. When the injected charge is between -6.3 and 54.5 nC nL -1 , the measured pH of the resulting droplets is within ±0.1 pH units of that predicted based on the magnitude of the injected charge. This technique can likely be adapted to electrogeneration of other reagents within microdroplets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CRADA Number NFE-19-07845 with American Nanotechnologies, Inc. (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-19-07845 between Oak Ridge National Laboratory (ORNL) and American Nanotechnologies, Inc. (ANI) focused on studying the use of dielectrophoresis as a mechanism to purify nanoparticles, particularly semiconducting carbon nanotubes (CNTs). The successful development of low-cost purification processes is a significant bottleneck in the adoption of semiconducting CNTs in commercial semiconducting devices. ANI is a startup company developing scalable systems for performing nanoparticle dielectrophoresis, which has previously been used only in microfluidic devices. The work done under this CRADA is exploring the use of ANI’s patent resonant dielectrophoresis (rDEP) technology and its ability to purify semiconducting CNTs at large scale. While continued work is on-going, r-DEP has proven to be a viable way to control nanoparticles in bulk dispersions. Optimization of the process is now underway to reach minimum viable product and begin material sales. Additionally, ANI and ORNL continue to collaborate on leveraging this technology to reach down the value chain and create new commercial devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Kinetics and Mechanism of Tetravalent Cerium Extraction by Di-2-Ethylhexyl Isobutyramide (DEHiBA)

DEHiBA is a fully-incinerable, CHON extractant with a high selectivity for hexavalent actinides. However, as a recently-developed ligand, much remains unknown about its physical and chemical properties, including its extraction and phase disengagement rates. Here, we present data on the phase transfer kinetics of Ce(IV) extraction and stripping by both DEHiBA and TBP collected using microfluidic devices. Ce(IV) was selected as a surrogate for Pu(IV) and Np(IV) in the initial tests of the microfluidics system prior to testing with the actinides. Pseudo first-order reaction rate constants are determined for both systems, and the corresponding Damköhler numbers (Da) are calculated to establish whether the extraction and stripping processes are kinetically or diffusion controlled. The stoichiometry of the extracted Ce(IV)-DEHiBA complex is determined, and the phase disengagement properties under extraction conditions are assessed using the dimensionless dispersion number. A possible explanation for the favorable extraction of Ce(IV) by DEHiBA, which is known to poorly extract many tetravalent cations, is presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) Sensor

The DNA Medicine Institute has produced a reusable microfluidic device that performs rapid, low-cost cell counts and measurements of electrolytes, proteins, and other biomarkers. The rHEALTH sensor is compact and portable, and it employs cutting-edge fluorescence detection optics, innovative microfluidics, and nanostrip reagents to perform a suite of hematology, chemistry, and biomarker assays from a single drop of blood. A handful of current portable POC devices provide generalized blood analysis, but they perform only a few tests at a time. These devices also rely on disposable components and depend on diverse detection technologies to complete routine tests-all ill-suited for space travelers on extended missions. In contrast, the rHEALTH sensor integrates sample introduction, processing, and detection with a compact, resource-conscious, and efficient design. Developed to monitor astronaut health on the International Space Station and during long-term space flight, this microscale lab analysis tool also has terrestrial applications that include POC diagnostics conducted at a patient's bedside, in a doctor's office, and in a hospital.

Chan, Eugene↗

Micro-Organ Devices

Micro-organ devices (MODs) are being developed to satisfy an emerging need for small, lightweight, reproducible, biological-experimentati on apparatuses that are amenable to automated operation and that imp ose minimal demands for resources (principally, power and fluids). I n simplest terms, a MOD is a microfluidic device containing a variety of microstructures and assemblies of cells, all designed to mimic a complex in vivo microenvironment by replicating one or more in vivo micro-organ structures, the architectures and composition of the extr acellular matrices in the organs of interest, and the in vivo fluid flows. In addition to microscopic flow channels, a MOD contains one or more micro-organ wells containing cells residing in microscopic e xtracellular matrices and/or scaffolds, the shapes and compositions o f which enable replication of the corresponding in vivo cell assembl ies and flows.

Gonda, Steven R.↗

The Double-Drained Drop: Symmetric Draining of Liquids from Containers with Interior Corners

An analytic solution is found for the late stage draining of a wetting capillary liquid from an interior corner. The solution exploits the symmetry of volumetric sink conditions at opposing ends of such a `double-drained' interior corner flow with applications ranging from liquid recovery in microfluidic devices on earth to liquid fuels scavenging in large fuel tanks aboard spacecraft. At long times t, the liquid depth is h~t^n, the liquid volume is V~ t^(2n), and the maximum volumetric liquid removal rate is Q~t^(2n-1), where n =-1. Representative experiments are conducted at larger length scales aboard the International Space Station and at microfluidic length scales in a terrestrial laboratory. Both sets of experiments confirm the solutions. We show that the approach offers a method to predict maximum drain rates from related geometries where a single drain location provides the required symmetry. We also show that the `fixed length' solution is one of many practical similarity solutions to the governing nonlinear evolution equation for the transient liquid profile along the interior corner. Exponential asymptotic Fourier series solutions are also found for partial corner fillling as well as draining.

microgravity↗

Medicine Delivery Device with Integrated Sterilization and Detection

Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. Nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely hig-hsurface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL s ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile.

Sheam, Michael J.↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗