Imaging by time-tagging photons with the multi-anode microchannel array detector system

The capability and initial use of the Multi-Anode Microchannel Array (MAMA) detector in the time-tag mode is reported. The detector hardware currently in use consists of a visible-light detector tube with a semitransparent photocathode proximity-focused to a high-gain curved-channel microchannel plate MCP. The photoevents are detected by a (256 x 1024)-pixel coincidence-anode array with pixel dimensions of 25 x 25 microns connected to charge-sensitive amplifiers and event-detection circuitry. In the time-lag mode, the detector delivers the pixel address and the time of arrival for each detected photon to an accuracy of 10 microns. The maximum count rate is limited by the speed of data-acquisition hardware. The MAMA detector in the time-lag mode is currently being evaluated in programs of astrometry and speckle imaging.

Timothy, J. G.↗

Hex-square moire patterns in imagers using microchannel plates

In electronic imaging detectors using microchannel plates, the mismatch between the pixels on a square mesh and the microchannels on a hexagonal mesh produces moire image defects. Theoretical statistical estimates of the sizes of the microposition offsets and the flat field intensity errors are calculated, showing the trade-off between resolution and position accuracy. A distinction is made between moments of spot images and moments of the single-pixel-response functions. As the resolution between the hex and square meshes is improved, the detector resolution is improved, but at the expense of an about 10 percent moire pattern. These moire patterns will not be properly corrected by dividing by the flat field image.

Lawrence, George M.↗

Performance characteristics of a curved-channel microchannel plate with a curved input face and a plane output face

The presently performance-evaluated format, in which a high-gain curved-channel microchannel plate (M2MCP) has a spherical concave input face and a plane output face, allows the input face of the MCP (1) to match such curved focal surfaces as that of a Rowland-circle spectrometer mounting, while (2) having a high-resolution plane readout array in proximity focus with the output face. This MCP has been evaluated in a discrete-anode multicathode microchannel array detector system. The saturated modal gain was found to be inversely proportional to the length/diameter ratio of the channels and directly proportional to the applied MCP voltage.

Slater, David C.↗

High resolution decoding techniques and single-chip decoders for multi-anode microchannel arrays

While the pixel size in a standard multianode microchannel array (MAMA) photon-counting detector is determined by the spacing of the anode array, the factor most fundamentally limiting pixel resolution is the spacing of the channels in the microchannel plate. Detector resolution can be improved by means of digitization followed by a centroiding procedure. The decoding hardware and the techniques for enhanced pixel resolution are presently discussed with a view to the factors of speed and complexity. A single-chip CMOS gate-array implementation of the decoder is devised and compared with existing multichip decoders' performance.

Kasle, David B.↗

Flat field response of the microchannel plate detectors used on the Extreme Ultraviolet Explorer

The results of the extreme ultraviolet (EUV) flat field calibrations of two of the flight detectors to be flown on the Extreme Ultraviolet Explorer Satellite (EUVE) are presented. Images of about 40 million detected events binned 512 by 512 are sufficient to show microchannel plate fixed pattern noise such as hexagonal microchannel multifiber bundle interfaces, 'dead' spots, edge distortion, and differential nonlinearity. Differences due to photocathode material and dependencies on EUV wavelength are also described. Over large spatial scales, the detector response is flat to better than 10 percent of the mean response, but, at spatial scales less than 1 mm, the variations from the mean can be as large as 20 percent.

Vallerga, J. V.↗

High resolution decoding of Multi-Anode Microchannel Array detectors

The Multi-Anode Microchannel Array (MAMA) is a photon counting detector which utilizes a photocathode for photon to electron conversion, a microchannel plate (MCP) for signal amplification and a proximity focused anode array for position sensitivity. The detector electronics decode the position of an event through coincidence discrimination. The decoding algorithm which associates a given event with the appropriate pixel is determined by the geometry of the array. A new algorithm incorporated into a CMOS Application Specific Integrated Circuit (ASIC) decoder which improves the pixel spatial resolution is described. The new algorithm does not degrade the detector throughput and does not require any modifications to the detector tube. The standard MAMA detector has a pixel size of 25 x 25 square microns, but with the new decoder circuit the pixel size is reduced to 12.5 x 12.5 square microns. We have built the first set of decode electronics utilizing the new ASIC chips and report here on the first imaging tests of this system.

Kasle, David B.↗

Performance of high resolution decoding with Multi-Anode Microchannel Array detectors

The Multi-Anode Microchannel Array (MAMA) is a microchannel plate based photon counting detector with applications in ground-based and space-based astronomy. The detector electronics decode the position of each photon event, and the decoding algorithm that associates a given event with the appropriate pixel is determined by the geometry of the anode array. The standard MAMA detector has a spatial resolution set by the anode array of 25 microns, but the MCP pore resolution exceeds this. The performance of a new algorithm that halves the pixel spacing and improves the pixel spatial resolution is described. The new algorithm does not degrade the pulse-pair resolution of the detector and does not require any modifications to the detector tube. Measurements of the detector's response demonstrate that high resolution decoding yields a 60 percent enhancement in spatial resolution. Measurements of the performance of the high resolution algorithm with a 14 micron MAMA detector are also described. The parameters that control high resolution performance are discussed. Results of the application of high resolution decoding to speckle interferometry are presented.

Kasle, David B.↗

Development efforts to improve curved-channel microchannel plates

Curved-channel microchannel plate (C-plate) improvements resulting from an ongoing NASA STIS microchannel plate (MCP) development program are described. Performance limitations of previous C-plates led to a development program in support of the STIS MAMA UV photon counter, a second generation instrument on the Hubble Space Telescope. C-plate gain, quantum detection efficiency, dark noise, and imaging distortion, which are influenced by channel curvature non-uniformities, have all been improved through use of a new centrifuge fabrication technique. This technique will be described, along with efforts to improve older, more conventional shearing methods. Process optimization methods used to attain targeted C-plate performance goals will be briefly characterized. Newly developed diagnostic measurement techniques to study image distortion, gain uniformity, input bias angle, channel curvature, and ion feedback, will be described. Performance characteristics and initial test results of the improved C-plates will be reported. Future work and applications will also be discussed.

Corbett, M. B.↗

Microchannel Plate Imaging Detectors for the Ultraviolet

There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

Siegmund, O. H. W.↗

Microchannel Plates for the UVCS and SUMER Instruments on the SOHO Satellite

The microchannel plates for the detectors in the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) and UVCS (Ultraviolet Coronograph Spectrometer) instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in late 1995 are described. A low resistance Z stack of microchannel plates (MCP's) is employed in a detector format of 27 mm x 10 mm using a multilayer cross delay line anode (XDL) with 1024 x 360 digitized pixels. The MCP stacks provide gains of greater than 2 x 10(exp 7) with good pulse height distributions (as low as 25% FWHM) under uniform flood illumination. Background rates of approx. 0.6 event cm(exp -2) sec(exp -1) are obtained for this configuration. Local counting rates up to about 800 events/pixel/sec have been achieved with little drop of the MCP gain. MCP preconditioning results are discussed, showing that some MCP stacks fail to have gain decreases when subjected to a high flux UV scrub. Also, although the bare MCP quantum efficiencies are close to those expected (10%), we found that the long wavelength response of KBr photocathodes could be substantially enhanced by the MCP scrubbing process. Flat field images are characterized by a low level of MCP fixed pattern noise and are stable. Preliminary calibration results for the instruments are shown.

Siegmund, O. H. W.↗

Miniature, low-power X-ray tube using a microchannel electron generator electron source

Embodiments of the invention provide a novel, low-power X-ray tube and X-ray generating system. Embodiments of the invention use a multichannel electron generator as the electron source, thereby increasing reliability and decreasing power consumption of the X-ray tube. Unlike tubes using a conventional filament that must be heated by a current power source, embodiments of the invention require only a voltage power source, use very little current, and have no cooling requirements. The microchannel electron generator comprises one or more microchannel plates (MCPs), Each MCP comprises a honeycomb assembly of a plurality of annular components, which may be stacked to increase electron intensity. The multichannel electron generator used enables directional control of electron flow. In addition, the multichannel electron generator used is more robust than conventional filaments, making the resulting X-ray tube very shock and vibration resistant.

Elam, Wm. Timothy↗

Design and Optimization of a Gas-Cooled, Airfoil Fin Microchannel Heat Exchanger

High-performance microchannel heat exchangers are needed to supply heat for power conversion for nuclear microreactors. An airfoil fin microchannel design, constructed of Alloy 617 with helium as the working fluid, was analyzed and optimized using a design of experiments with artificial intelligence and machine learning techniques. The use of airfoil fins offers the potential to reduce pressure drop across the heat exchanger, as compared to other types of channel configurations. A framework for topology optimization of airfoil fin PCHEs has been developed that can be readily extended to different fin sizes and shapes, as well as different inlet and operating conditions, materials of construction, and working fluids. An optimization procedure was developed that employs computational fluid dynamics for a set of design points identified using Latin hypercube sampling. STAR-CCM+ was used to analyze a simplified two-channel configuration where five parameters were varied – inlet angle, fin scale, extent of staggering, transverse and longitudinal pitches. Two methods were compared for generating surrogate models – a 5D polynomial and a regression neural network. A response surface approximation was created from the surrogate models and input to a genetic algorithm. The genetic algorithm identified a set of optimal points on the Pareto front. The optimal geometry was found across six channel Reynolds numbers ranging from 1000 to 5000 to analyze how varying inlet conditions affects the optimal design. A set of optimal designs that maximizes heat transfer and minimizes pressure drop was identified, and a thermal stress analysis was performed on the optimal design. This work has developed a digital framework for the expedient topology design and evaluation of PCHE designs for gas-cooled microreactor applications. Correlations for the Nusselt number and Darcy friction factor were developed that can be useful for thermal hydraulic analyses using system codes. A thermal stress analysis was conducted and a brief discussion of the status of code cases of PCHEs for nuclear applications is given. Testing and thermomechanical modeling is needed to facilitate future code compliance of PCHEs for high pressure and high temperature applications.

42 ENGINEERING↗

Microchannel Geometries for Improved Heat Transfer with Low-GWP refrigerants

Due to efforts aimed at decarbonizing industries, the use of refrigerants with low global warming potential (GWP) is highly recommended in the air-conditioning and refrigeration sectors. Despite possessing low-GWP values of less than 150, hydrofluoroolefins (HFO) exhibit relatively lower heat transfer performance compared to conventional hydrofluorocarbons (HFC) under certain operating conditions. In contrast to HFCs, there is a high demand for enhanced surfaces to meet the needs of heat transfer systems utilizing low GWP refrigerants. Accordingly, this study analyzes the pool boiling performance of low-GWP refrigerants in microchannel geometries. The experiments were carried out at various heat flux levels on both smooth and enhanced surfaces. The pool boiling behavior of low-GWP refrigerant R1234yf was compared to that of R-134a refrigerant in terms of heat transfer coefficient and wall superheat. The results indicate that the heat transfer coefficients of the enhanced surface are significantly higher than those of the smooth surface. Furthermore, the microchannel geometry demonstrated a lower wall superheat compared to the smooth surface. Additionally, a visualization study was performed using a high-speed camera to understand the pool boiling mechanism of low-GWP refrigerants on both smooth and enhanced surfaces.

Murugan, Muneeshwaran↗

Experimental Evaluation of a Microchannel Condenser for R600a Domestic Refrigerators

Domestic refrigerators are among the most common household appliances, accounting for approximately 4% of total household energy consumption, which is higher than that of clothes dryers, lighting, or cooking appliances. With nearly 13 million new domestic refrigerators sold annually, even marginal improvements in their energy performance can yield significant reductions in overall energy demand and cost. This study focuses on enhancing the performance of domestic refrigerators using R600a as the refrigerant. Most domestic refrigerators currently employ wire-and-tube condensers, which are bulky and require a larger refrigerant charge. Given that R600a is classified as an A3 flammable refrigerant under ASHRAE standards, minimizing the system charge while maintaining or improving performance is critical. To address this, a compact and light weight single-pass serpentine microchannel heat exchanger (made of aluminum) was adopted as a condenser, replacing the conventional wire-and-tube configuration. The modified system was experimentally tested according to AHAM test standards, and charge optimization was performed. The results demonstrated that the refrigerator equipped with the microchannel condenser achieved a 5.3% reduction in energy consumption compared to the baseline configuration with wire-and-tube condenser.

Murugan, Muneeshwaran [ORNL] (ORCID:00000003340352↗

A simple approach for characterizing the spatially varying sensitivity of microchannel plate detectors

Herein we present a simple approach to characterize the spatial variation of the gain in microchannel plate (MCP) coupled to phosphor detectors using single electron or photon hits. The technique is easy to implement and general enough to be extended to other kinds of detectors. We demonstrate the efficacy of the approach on both laboratory and Monte Carlo generated datasets. Furthermore, we use the approach to measure the variation in gain over time as the MCP is exposed to an increasing number of electrons.

47 OTHER INSTRUMENTATION↗

Production of microchannel plates using nano-scale additive manufacturing

Microchannel plate (MCP) detectors have been the workhorse detector for many applications, including space borne ultra-violet imaging and spectrographic instruments. Recent advances in additive manufacturing (AM) have enabled fabrication of complex structures with nano-scale resolution facilitating the production of highly customizable MCPs. Using AM to produce MCPs potentially has many advantages over traditional fused glass substrates, including better material control (e.g., more robust glasses or ceramics), better control of microscopic features (e.g., unique pore geometries to improve performance), and better control of macroscopic features (e.g., printing precision curved surfaces for focal plane matching). Through a collaboration with industry, national laboratory, and university partners, small format microcapillary array substrates were produced using a standard polymer photoresin. In conclusion, these substrates were functionalized using atomic layer deposition and their performance was compared to current state-of-the-art Pb-glass and borosilicate-glass MCPs.

36 MATERIALS SCIENCE↗

Study of Static Microchannel Plate Saturation Effects for the Fast Plasma Investigation Dual Electron Spectrometers on NASA's Magnetospheric MultiScale Mission

Imaging detecting systems based on microchannel plates (MCPs) are the most common for low energy plasma measurements for both space borne and ground applications. One of the key parameters of these detection systems is the dynamic range of the MCP's response to the input fluxes of charged particles. For most applications the dynamic range of the linear response should be as wide as possible. This is especially true for the Dual Electron Spectrometers (DESs) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission because a wide range of input fluxes are expected. To make use of the full available dynamic range, it is important to understand the MCP response behavior beyond the linear regime where the MCPs start to saturate. We have performed extensive studies of this during the characterization and calibration of the DES instruments and have identified several saturation effects of the detection system. The MCP itself exhibits saturation when the channels lack the ability to replenish charge sufficiently rapidly. It is found and will be shown that the ground system can significantly impact the correct measurement of this effect. As the MCP starts to saturate, the resulting pulse height distribution (PHD) changes shape and location (with less pulse height values), which leads to truncation of the PHD by the threshold set on the detection system discriminator. Finally, the detection system pulse amplifier exhibits saturation as the input flux drives pulse rates greater than its linear response speed. All of these effects effectively change the dead time of the overall detection system and as a result can affect the quality and interpretation of the flight data. We present results of detection system saturation effects and their interaction with special emphasis on the MCP related effects.

detecting system↗

Additively manufactured cryogenic microchannel distillation device for air separation

Abstract The efficiency of air separation is tested using three different small‐scale cryogenic distillation columns. The performance of a random packed column is compared to the performance of two microchannel distillation (MCD) columns that use thin wicking structures and gas flow channels to achieve process intensification. The MCD columns tested include a plate‐type layered column and an additively manufactured porous honeycomb (AMPH) column. For columns with 25.4 cm of active height and run under similar conditions, the packed, plate‐type layering, and AMPH columns achieved approximate height equivalent of a theoretical plate (HETP) values of 5.5, 3.7, and 3.2 cm for nitrogen, and 5.9, 4.9, and 3.3 cm for argon. The AMPH column can produce up to 0.4 SLM of more than 90% purity oxygen with 12 W of cooling lift. These results demonstrate the feasibility of using additive manufacturing to construct MCD devices and pave a way for constructing novel MCD designs.

36 MATERIALS SCIENCE↗