Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mesurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Navier-Stokes solutions with surface catalysis for Martian atmospheric entry

In this study numerical solutions have been obtained for two-dimensional axisymmetric hypersonic nonequilibrium CO2 flow over a high angle blunt cone with appropriate surface boundary conditions to account for energy and mass conservation at the body surface. The flowfield is described by the Navier-Stokes equations and multicomponent conservation laws which account for both translational and internal vibrational nonequilibrium effects. Complete forebody solutions have been obtained for the peak heating point of the Mars entry trajectory specified in the proposed NASA MESUR (Mars Environmental Survey) project. In these solutions, radiative equilibrium wall temperature and surface heating distributions are determined over the MESUR aeroshell forebody for entry velocity equal to 7 km/sec with varying degrees of surface catalysis. The effects of gas kinetics, surface catalysis, transport properties, and vibrational relaxation times on the surface heating are examined. The results identify some important issues in the prediction of surface heating for flows in thermochemical nonequilibrium and show that the Navier-Stokes code used herein is effective for thermal protection system design and materials selection.

Chen, Y.-K.↗

Planetary surface exploration: MESUR/autonomous lunar rover

Planetary surface exploration micro-rovers for collecting data about the Moon and Mars was designed by the Department of Mechanical Engineering at the University of Idaho. The goal of both projects was to design a rover concept that best satisfied the project objectives for NASA-Ames. A second goal was to facilitate student learning about the process of design. The first micro-rover is a deployment mechanism for the Mars Environmental SURvey (MESUR) Alpha Particle/Proton/X-ray instruments (APX). The system is to be launched with the sixteen MESUR landers around the turn of the century. A Tubular Deployment System and a spiked-legged walker was developed to deploy the APX from the lander to the Martian surface. While on Mars the walker is designed to take the APX to rocks to obtain elemental composition data of the surface. The second micro-rover is an autonomous, roving vehicle to transport a sensor package over the surface of the moon. The vehicle must negotiate the lunar-terrain for a minimum of one year by surviving impacts and withstanding the environmental extremes. The rover is a reliable track-driven unit that operates regardless of orientation which NASA can use for future lunar exploratory missions. A detailed description of the designs, methods, and procedures which the University of Idaho design teams followed to arrive at the final designs are included.

Stauffer, Larry↗

Investigation of Mars Rotational Dynamics Using Earth-based Radio Tracking of Mars Landers

The development of space geodetic techniques over the past two decades has made it possible to measure the rotational dynamics of the Earth at the milliarcsecond level, improving our geophysical models of the Earth 's interior and the interactions between the solid Earth and its atmosphere. We have found that the rotational dynamics of Mars can be determined to nearly the same level of accuracy by acquiring Earth-based two-way radio tracking observations of three or more landers globally distributed on the surface of Mars. Our results indicate that the precession and long-term obliquity changes of the Mars pole direction can be determined to an angular accuracy corresponding to about 15 cm/yr at the planet's surface. In addition, periodic nutations of the pole and seasonal variations in the spin rate of the planet can be determined to 10 cm or less. Measuring the rotation of Mars at this accuracy would greatly improve the determination of the planet' s moment of inertia and would resolve the size of a planetary fluid core, providing a valuable constraint on Mars interior models. Detecting seasonal variations in the spin rate of Mars would provide global constraints on atmospheric angular momentum changes due to sublimation of the Mars CO2 polar ice caps. Finally, observation of quasisecular changes in Mars obliquity would have significant implications for understanding long-term climatic change. The key to achieving these accuracies is a globally distributed network of Mars landers with stable, phase-coherent radio transponders. By simultaneously acquiring coherent two-way carrier phase observations between a single Earth tracking station and multiple Mars landers, Earth media errors are essentially eliminated, providing an extremely sensitive measure of changes in the differential path lengths between the Earth tracking station and the Mars landers due to Mars rotation. Time variability of the instrumental phase delay through the radio transponder may represent the limiting error source for this technique. Calibration of the transponder stability to about 0.1 ns or less, over a single tracking arc of up to 12 hr, is sufficient to provide the decimeter-level determination of Mars orientation parameters quoted above. We will provide a detailed description of the multilander tracking technique and the requirements it imposes on both the lander radio system and the Earth-based ground-tracking system. This concept is currently part of the strawman science plan for the Mars Environmental Survey (MESUR) mission and complements many of the other MESUR science goals.

Edwards, C. D., Jr.↗

A Mars Environmental Survey mission concept

The Mars Environmental Survey, or 'MESUR' mission presently discussed proceeds by emplacing a network of small stations on the Martian surface. These stations will determine the global seismicity of the planet, to facilitate studies of its internal structure; they will also broaden knowledge of atmospheric and surface meteorology conditions and determine the major and minor elements of surface soil and rock compositions. They are also expected to deepen understanding of Mars' middle and upper atmosphere. Attention is given to the design and operations of the MESUR lander.

Hubbard, G. S.↗

The roughness of the Martian surface: A scale dependent model

In the coming decade, several lander missions to Mars are planned (e.g., MESUR Pathfinder, MESUR). One of the dangers facing planners of these missions is the rough topography observed at both Viking Lander sites. Both landing sites are ubiquitously covered with meter-scale boulders. Objects of this size pose obvious threats to soft landers, especially at Mars where the distance from Earth causes prohibitive time lags between the transmission of commands and feedback from the spacecraft. An obvious solution is to scout for a 'smooth' site prior to the landing. However, the best resolutions realizable on current and future missions (i.e., Mars Observer) are on the order of several meters. Even at this scale, boulders of 1-2 meters in size are unresolvable. Additionally, the amount of time and spacecraft resources required to search even a small area of the planet are unrealistic given other mission objectives. An alternative is to determine the 'roughness' of the surface at a subpixel scale using bidirectional reflectance observations. Much larger areas of the planet can be searched, and much of the search can easily be automated. The morphology of the martian plains observed by the Viking Landers is physically simple. The surface is covered with a layer (approximately flat lying) of aeolian sediment from which numerous outcrops of bedrock and boulders protrude. This morphology, while simple, will be difficult to characterize from orbit using traditional bidirectional reflectance models for two reasons. First, modeling the surface as facets with Gaussian or exponential slope distributions is not realistic given the morphology described above. Second, the roughness parameter is an 'average' of the roughness at scales ranging from the wavelength of light being scattered to the pixel size of the observation. Thus, there is no definite scale of roughness that can be extracted from the Hapke roughness parameter. Using the concepts of geometric and boolean models developed by several workers, we have developed a model for the bidirectional reflectance of a surface morphology comparable to that observed at the Viking Lander sites.

Shepard, M. K.↗

Temperature/pressure and water vapor sounding with microwave spectroscopy

Two intense microwave spectra lines exist in the martian atmosphere that allow unique sounding capabilities: water vapor at 183 GHz and the (2-1) rotational line of CO at 230 GHz. Microwave spectra line sounding is a well-developed technique for the Earth's atmosphere for sounding from above from spacecraft and airplanes, and from below from fixed surface sites. Two simple instruments for temperature sounding on Mars (the CO line) and water vapor measurements are described. The surface sounder proposed for the MESUR sites is designed to study the boundary layer water vapor distribution and the temperature/pressure profiles with vertical resolution of 0.25 km up to 1 km with reduced resolution above approaching a scale height. The water channel will be sensitive to a few tenths of a micrometer of water and the temperature profile will be retrieved to an accuracy between 1 and 2 K. The latter is routinely done on the Earth using oxygen lines near 60 GHz. The measurements are done with a single-channel heterodyne receiver looking into a 10-cm mirror that is canned through a range of elevation angles plus a target load. The frequency of the receiver is sweep across the water and CO lines generating the two spectra at about 1-hr intervals throughout the mission. The mass and power for the proposed instrument are 2 kg and 5-8 W continuously. The measurements are completely immune to the atmospheric dust and ice particle loads. It was felt that these measurements are the ultimate ones to properly study the martian boundary layer from the surface to a few kilometers. Sounding from above requires an orbiting spacecraft with multichannel microwave spectrometers such as the instrument proposed for MO by a subset of the authors, a putative MESUR orbiter, and a proposed Discovery mission called MOES. Such an instrument can be built with less than 10 kg and use less than 15 W. The obvious advantage of this approach is that the entire atmosphere can be sounded for temperature and water vapor in a few hours with somewhat better than a scale height resolution. If a bigger mirror is used (greater than 30 cm) limb sounding geometry can be employed and half scale height resolution achieved to altitudes up to at least 60 km. Again, the measurements are immune to dust and ice loads. Water vapor sensitivity of 0.1 micrometer can be achieved (even with a nadir instrument) and temperature profiles retrieved to an accuracy of better than 2 K from the surface to about 60 km. Winds can be measured from the doppler shifts of CO lines in the limb sounding mode.

Muhleman, D. O.↗

Science objectives for short-range rovers on Mars

The baseline small lander network mission MESUR (Mars Environmental Survey) is reviewed and the tasks that a microrover could do to improve the science return on such a mission are described. An early precursor small lander mission under study, called MESUR Pathfinder, and the science, technology, and mission engineering tasks that are being considered for the microrover are also described. A description of a microrover (instrumented with microsensors), which is applicable to a small Mars lander mission, is given.

Golombek, M. P.↗

Planetary surface exploration MESUR/autonomous lunar rover

Planetary surface exploration micro-rovers for collecting data about the Moon and Mars have been designed by the Department of Mechanical Engineering at the University of Idaho. The goal of both projects was to design a rover concept that best satisfied the project objectives for NASA/Ames. A second goal was to facilitate student learning about the process of design. The first micro-rover is a deployment mechanism for the Mars Environmental Survey (MESUR) Alpha Particle/Proton/X-ray (APX) Instrument. The system is to be launched with the 16 MESUR landers around the turn of the century. A Tubular Deployment System and a spiked-legged walker have been developed to deploy the APX from the lander to the Martian Surface. While on Mars, the walker is designed to take the APX to rocks to obtain elemental composition data of the surface. The second micro-rover is an autonomous, roving vehicle to transport a sensor package over the surface of the moon. The vehicle must negotiate the lunar terrain for a minimum of one year by surviving impacts and withstanding the environmental extremes. The rover is a reliable track-driven unit that operates regardless of orientation that NASA can use for future lunar exploratory missions. This report includes a detailed description of the designs and the methods and procedures which the University of Idaho design teams followed to arrive at the final designs.

Stauffer, Larry↗

A broad-band microseismometer for planetary operations

There has recently been renewed interest in the development of instrumentation for making measurements on the surface of Mars. This is due to the Mars Environmental Survey (MESUR) Mission, for which approximately 16 small, long-lived (2-10 years), relatively inexpensive surface stations will be deployed in a planet-wide network. This will allow the investigation of processes (such as seismology and meteorology) which require the simultaneous measurement of phenomena at many widely spaced locations on the surface over a considerable length of time. Due to the large number of vehicles involved, the mass, power, and cost of the payload will be severely constrained. A seismometer has been identified as one of the highest priority instruments in the MESUR straw-man payload. The requirements for an effective seismic experiment on Mars place a number of constraints on any viable sensor design. First, a large number of sensors must be deployed in a long-lived global network in order to be able to locate many events reliably, provide good spatial sampling of the interior, and increase the probability of seismic detection in the event of localized seismicity and/or high attenuation. From a practical standpoint, this means that individual surface stations will necessarily be constrained in terms of cost, mass, and power. Landing and thermal control systems will probably be simple, in order to minimize cost, resulting in large impact accelerations and wide daily and seasonal thermal swings. The level of seismic noise will determine the maximum usable sensitivity for seismometer. Unfortunately, the ambient seismic noise level for Mars is not well known. However lunar seismic noise levels are several orders of magnitude below that of the Earth. Sensitivities on the order of 10(exp -11)g over a bandwidth of .04 to 20 Hz are thought to be necessary to fulfill the science objectives for a seimometer placed on the Martian surface. Silicon micromachined sensor technology offers techniques for the fabrication of monolithic, robust, compact, lower power and mass accelerometers. Conventional micro-machined accelerometers have been developed and are commercially available for high frequency and large acceleration measurements. The new seismometer we are developing incorporates certain principles of conventional silicon micromachined accelerometer technology. However, currently available silicon micromachined sensors offer inadequate sensitivity and bandwidth for the Mars seismometer application. Our implementation of an advanced silicon micromachined seismometer is based on principles recently developed at JPL for high-sensitivity position sensor technology.

Banerdt, W. B.↗

Finding the path to a better Mars rover

A Microrover Flight Experiment (MFEX) based on a basic Rocky 4 design and conducted in the framework of the NASA Mars Environmental Survey (MESUR) Pathfinder program is described. The MFEX rover design features six powered wheels attached by a set of 'bogie levers' to a single body. The rover is designed to perform technology, science, and mission experiments. Instruments on the rover mechanisms will determine wheel-soil interactions, detect hazards, and determine navigational errors. Science data will be gathered using an alpha-proton-X-ray spectrometer against one or more rocks, and possible soil. The pathfinder will also serve as an engineering test of a transport and landing system for the MESUR network mission and the rover will image the lander to assess its condition.

Pivirotto, Donna S.↗

Atmosphere structure and meteorology instrument for Mars Pathfinder

The MESUR Science Definition Team recommended that all MESUR probes, including Pathfinder, carry an ASI/MET experiment, in order that no opportunity be lost to characterize the atmosphere of Mars in passing through it. The experiment was thus included on Pathfinder from the start (February 1992), but on an essentially noninterference basis: It was to make no unusual demands on the spacecraft. A Science Advisory Team was appointed by NASA Headquarters in September 1993 first met on November 3rd to initiate formal science participation, and the level of activity has since been high. The instrument passed its Preliminary Design Review on February 28th.

Seiff, Alvin↗

Precision X-band Doppler and ranging navigation for current and future Mars exploration missions

This paper describes a navigation error covariance analysis of two scenarios derived from the Mars Observer mission and the planned Mars Environmental SURvey (MESUR) Pathfinder mission, respectively. The analysis was performed to establish the potential navigational performance of the X-band tracking system in NASA's Deep Space Network, and to evaluate the sensitivity of the predicted performance to variations in the quantity of data acquired, the ground system error modeling assumptions, and data reduction schemes. The simulated data arcs used in the analysis are representative of the actual data arcs that will be used to predict the aim point for the Mars orbit insertion maneuver, in the case of Mars Observer, and the interplanetary trajectory aim point corresponding to the target Mars landing site in the case of MESUR Pathfinder. The results indicate that with a suitable sequential data reduction scheme and accurate calibrations of instrumentation, transmission media, and platform model parameters, navigation accuracies of 5 to 15 km (1 sigma) can be achieved, equivalent to 15 to 40 nrad in geocentric angle uncertainty.

Estefan, Jeffrey A.↗

Proficiency Testing as a tool to monitor consistency of measurements in the IAEA/WHO Network of Secondary Standards Dosimetry Laboratories

The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) established a Network of Secondary Standards Dosimetry Laboratories (IAEA/WHO SSDL Network) in 1976. Through SSDLs designated by Member States, the Network provides a direct link of national dosimetry standards to the international measurement system of standards traceable to the Bureau International des Poids et Mesures (BIPM). Within this structure and through the proper calibration of field instruments, the SSDLs disseminate S.I. quantities and units.To ensure that the services provided by SSDL members to end-users follow internationally accepted standards, the IAEA has set up two different comparison programmes. One programme relies on the IAEA/WHO postal TLD service and the other uses comparisons of calibrated ionization chambers to help the SSDLs verify the integrity of their national standards and the procedures used for the transfer of the standards to the end-users. The IAEA comparisons include {sup 60}Co air kerma (N{sub K}) and absorbed dose to water (N{sub D,W}) coefficients. The results of the comparisons are confidential and are communicated only to the participants. This is to encourage participation of the laboratories and their full cooperation in the reconciliation of any discrepancy.This work describes the results of the IAEA programme comparing calibration coefficients for radiotherapy dosimetry, using ionization chambers. In this programme, ionization chambers that belong to the SSDLs are calibrated sequentially at the SSDL, at the IAEA, and again at the SSDL. As part of its own quality assurance programme, the IAEA has participated in several regional comparisons organized by Regional Metrology Organizations.The results of the IAEA comparison programme show that the majority of SSDLs are capable of providing calibrations that fall inside the acceptance level of 1.5% compared to the IAEA.

61 RADIATION PROTECTION AND DOSIMETRY↗

The International Framework for Maintaining Equivalence and Traceability in Radionuclide Metrology

Confidence that a testing or calibration laboratory consistently obtains reliable results is of major importance to users of laboratory services and participation in proficiency testing schemes provides laboratories with an objective means of assessing and demonstrating the level of confidence that can be ascribed to the reliability of the data they are producing. That level of confidence, in turn, depends on the quality of the proficiency tests and, in particular, on the accuracy of the property values associated with the test samples. In the ideal situation, the relevant property value, such as the activity of a particular radionuclide in a test matrix, will be directly traceable to the SI via comparisons with a national or international metrology institute (NMI). This, in turn, begs the question of, how reliable are the results from that NMI.Demonstration of that reliability at the highest metrological levels is achieved through inter-laboratory comparisons that are conducted between national and international metrological institutes. These are coordinated primarily by the Bureau International des Poids et Mesures (BIPM) via Key Comparisons or by comparisons within Regional Metrological Organisations (RMOs), with the results from those RMO exercises being linked to the BIPM Key Comparison results. Such programmes have been in place for many years but they have grown in importance and frequency over the past decade. Tabulation of these comparison data has been regularized recently and made available to the user communities via the BIPM Key Comparison Database (KCDB).In the field of ionizing radiation, the radionuclide metrology discipline exhibits a number of special features. For example, these include the number of potential radionuclides in a user sample; the variety of physical and chemical formats that may be presented; the statistical and temporal effects of radioactive decay; the variations in primary standardization techniques; and the restricted applicability of those primary standardization techniques to the full range of potential radionuclides and activities. Each of these, singly or in combination, ensure that there can never be a fully comprehensive set of Key Comparisons which will cover the requirements of the user community and, in turn, compromise the ability to provide a full range of proficiency tests for testing and calibration laboratories.These problems are discussed, in the context of radioactivity measurements, together with the structure and range of Key Comparisons and associated databases at the highest international level that are currently in place to underpin the proficiency tests that are necessary for the user communities in this field of application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The cloud monitor by an infrared camera at the Telescope Array experiment

The mesurement of the extensive air shower using the fluorescence detectors (FDs) is affected by the condition of the atmosphere. In particular, FD aperture is limited by cloudiness. If cloud exists on the light path from extensive air shower to FDs, fluorescence photons will be absorbed drastically. Therefore cloudiness of FD's field of view (FOV) is one of important quality cut condition in FD analysis. In the Telescope Array (TA), an infrared (IR) camera with 320x236 pixels and a filed of view of 25.8 deg. x19.5 deg. has been installed at an observation site for cloud monitoring during FD observations. This IR camera measures temperature of the sky every 30 min during FD observation. IR camera is mounted on steering table, which can be changed in elevation and azimuthal direction. Clouds can be seen at a higher temperature than areas of cloudless sky from these temperature maps. In this paper, we discuss the quality of the cloud monitoring data, the analysis method, and current quality cut condition of cloudiness in FD analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and characterization of ZnO:TiO{sub 2} nano composites thin films deposited on glass substrate by sol-gel spray coating technique

In this work, (ZnO){sub x}:(TiO{sub 2}){sub 1-x} nano composites thin films, with x = 1, 0.75, 0.5, 0.25, and 0, have been prepared by sol–gel spray coating technique onto glass substrate. Pure TiO{sub 2} and ZnO thin films were synthesized from titanium isopropoxide-based and zinc acetate-based precursor solutions, respectively, whereas the composite films were obtained from the mixture of these solutions at the specific % vol ratios. The properties and performance of nano composite ZnO, TiO{sub 2} and ZnO:TiO{sub 2} thin films at different composition have been investigated. Ultraviolet – Visible (UV-Vis) Spectrophotometer and Scanning Electron Microscopy (SEM) were employed in order to get morphology and transmittance of thin films. Testing the ability of photocatalytic activity of obtained films was conducted on photodegradation of methylene blue (MB) dye and organic pollutants of wastewater under a 30 watt UV light irradiation, then testing BOD, COD and TPC were conducted. Using the Tauc model, the band-gap energy decreased from 3.12 eV to 3.02 eV for the sample with x = 1 and 0, respectively. This decrease occured along with the replacement of percentage of ZnO by TiO{sub 2} on the films. This decrease also reduced the minimum energy that required for electron excitation. Obtained thin films had nanoscale roughness level with range 3.64 to 17.30 nm. The film with x= 0 has the biggest removal percentage on BOD, COD and TPC mesurements with percentage 54.82%, 62.73% and 99.88%, respectively.

36 MATERIALS SCIENCE↗

Weak lensing magnification in the Dark Energy Survey Science Verification data

In this paper the effect of weak lensing magnification on galaxy number counts is studied by cross-correlating the positions of two galaxy samples, separated by redshift, using data from the Dark Energy Survey Science Verification dataset. The analysis is carried out for two photometrically-selected galaxy samples, with mean photometric redshifts in the $0.2 < z < 0.4$ and $0.7 < z < 1.0$ ranges, in the riz bands. A signal is detected with a $3.5\sigma$ significance level in each of the bands tested, and is compatible with the magnification predicted by the $\Lambda$CDM model. After an extensive analysis, it cannot be attributed to any known systematic effect. The detection of the magnification signal is robust to estimated uncertainties in the outlier rate of the pho- tometric redshifts, but this will be an important issue for use of photometric redshifts in magnification mesurements from larger samples. In addition to the detection of the magnification signal, a method to select the sample with the maximum signal-to-noise is proposed and validated with data.

79 ASTRONOMY AND ASTROPHYSICS↗

Test system for charge collection efficiency measurement (SYCOC) for neutron irradiated silicon sensors

One of the constraints in using standard Float Zone silicon layer as base material for tracking in particle physics is its radiation hardness. The detection efficiency is degraded by the introduction of defects in the silicon crystal and charge trapping becomes the main problem. The Charge Collection Efficiency (CCE) is a relevant parameter in order to determine the detection performance of such devices. A state-of-the-art test system named 'Systeme de mesure de collection de charge' (SYCOC) has been developed for the characterization of diode and microstrip silicon sensors before and after irradiation. The system is designed to perform Charge Collection Efficiency (CCE) and Transient Current Technique (TCT) measurements with laser and radioactive sources in a controlled environment. Initial measurements on diodes are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗