At least 73 records · Page 4

Thermal and Mechanical Design of a High-Voltage Power Electronics Package: Preprint

Thermal and mechanical design aspects of a power electronic package with 5-kV GaN devices are presented. Through finite element analyses, the impact of different cooling configurations and device location on the thermal performance and reliability of the package was investigated. It was found that placing the devices closer to the direct-bond-copper substrate as opposed to a centered approach in the proposed double-sided-cooling configuration resulted in improved heat dissipation. This approach also reduced the total number of attachment layers, thereby likely improving the reliability of the package. Furthermore, simulations revealed that the device location had a negligible impact on the thermomechanical behavior of the attachment layers, as they are more prone to the local coefficient of thermal expansion mismatch.

27 ARPA - Advanced Research Projects Agency-Energy↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen Enrichment for Solid Oxide Fuel Cell Gas Turbine (SOFC/GT) Hybrid Power Generation Systems Using Mechanical Gas Separation

This presentation, given at the 37 th annual Pittsburgh Coal Conference on September 8-11, 2020, includes information on the process, previous work, normal and oblique shocks model, diffuser design model, and calculation results (expansion, recompression with no losses, and recompression with mass depletion). Summary includes the concept of aerodynamic separation of water and carbon dioxide from a SYNGAS stream and that deposition was modeled by mass depletion from a compressible flow.

VanOsdol, John↗

Electron dynamics in radio frequency magnetron sputtering argon discharges with a dielectric target

Abstract We demonstrate a self-consistent and complete description of electron dynamics in a typical electropositive radio frequency magnetron sputtering (RFMS) argon discharge with a dielectric target. The electron dynamics, including the electron power absorption dynamics in one radio frequency (RF) period, is studied via a fully kinetic 2d3v particle-in-cell/Monte Carlo collision (PIC/MCC) electrostatic simulation. The interplay between the fundamental plasma parameters is analyzed through their spatiotemporal dynamics. Due to the influence of magnetic trap on the electron transport, a spatially dependent charging that perturbs the electric potential is observed on the dielectric target surface, resulting in a spatially dependent ion energy distribution along the target surface. The E × B drift-to-discharge current ratio is in approximate agreement with Bohm diffusion. The electron power absorption can be primarily decoupled into the positive Ohmic power absorption in the bulk plasma region and the negative pressure-induced power absorption near the target surface. Ohmic power absorption is the dominant electron power absorption mechanism, mostly contributed by the azimuthal electron current. The power absorption due to electron inertial effects is negligible on time-average. Both the maximum power absorption and dissipation of electrons appear in the bulk plasma region during the second half of the RF period, implying a strong electron trapping in magnetron discharges. The contribution of secondary electrons is negligible under typical RFMS discharge conditions.

Physics↗

Power Decoupling Method for Voltage Source Inverters Using Grid Voltage Modulated Direct Power Control in Unbalanced System

The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. Here, this article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

42 ENGINEERING↗

MaDEVIoT: Cyberattacks on EV Charging Can Disrupt Power Grid Operation

Extensive roll-out of electric vehicles (EVs) requires large-scale deployment of high-power EV Charging Stations (EVCSs). EVCSs are connected to the internet using Internetof- Things (IoT) such as smartphones, to improve the charging experience of users and increase their profitability. This paper studies the feasibility of demand-side cyberattacks launched on power grids via such internet-connected highpower EVCSs. The attack mechanism distorts power grid frequency and voltage, and has the potential to trigger systemwide outages. The case study, based on the power grid and EV deployment plans in Manhattan, New York, illustrates potential impacts of such attacks. The results show that such attacks will become feasible in Manhattan, New York in 2030, as EV adoption increases. Furthermore, the attacks in 2030 are feasible even compromising a single company’s EVCS server in Manhattan, New York. The attacks can cause line overloads and trip over-frequency protection relays, causing system-side blackout in the power grid in Manhattan, New York. The paper informs planning authorities and power grid operators involved with the roll-out of EV charging infrastructure about potential cyberthreats to power grids via manipulating internet-connected high-power EVCSs.

Acharya, Samrat S.↗

Simulation of the supercritical CO 2 recompression Brayton power cycle with a high-temperature regenerator

The supercritical carbon dioxide (sCO 2 ) recompression Brayton cycle promises higher efficiency and lower capital cost than traditional steam Rankine power cycles. However, achieving high efficiency requires large, highly effective recuperators. Regenerators may be a low-cost alternative to printed circuit and micro-tube heat exchangers for recuperation in sCO 2 power cycles. Regenerators are a periodic heat exchanger in which thermal energy is extracted from the hot stream, stored in solid media, and then released to the cold stream at a later time. Fixed bed regenerators with valves to direct fluid are the preferred method for implementing regenerators in power cycles, but the inherently transient nature of these systems has not been characterized for this application. This study presents the simulation of a high-temperature regenerator within a 10 MWe sCO 2 recompression Brayton cycle. A transient, one-dimensional regenerator model presented in a previous study is used to simulate the regenerator. Dynamic heat exchanger models are also developed for the precooler, low-temperature recuperator, and primary heat exchanger, and the compressors and the turbine are modeled with off-design performance maps. We assess two regenerator-valve design options; one for fast switching, and one for reduced flow rate fluctuations. System simulation finds that both designs see significant fluctuations in turbomachinery flow rate, turbomachinery and system power, and regenerator discharge process outlet temperature. While designing the regenerator-valve subsystem for lower fluctuations is possible, the regenerator cold discharge temperature and net power still fluctuate by ±77.6°C and 6%, respectively. Increasing buffer volume is not effective at sufficiently reducing these fluctuations, but adding a packed bed in between the regenerator and the primary heat exchanger can reduce regenerator discharge process outlet temperature fluctuations to 6.4°C. Further reductions could be possible by increasing the size of this packed bed.

42 ENGINEERING↗

Novel Fault Location Method for Power Systems Based on Attention Mechanism and Double Structure GRU Neural Network

Fault location is one of the most essential techniques to maintain the stable operation of power systems. A fast and accurate fault location allows operators to restore power grids faster and avoid economic losses. Conventional methods rely on expert knowledge to extract the necessary features (e.g. DWT, DFT). For large systems, more coupling effects of transmission lines require more complex feature engineering, and incomplete features can easily introduce large errors. To overcome this, a deep learning approach without manual feature extraction is introduced to the fault location model under big data application. Towards this end, in the proposed method, the attention mechanism, the Bi-GRU and a dual structure network are applied to analyze the current data from different perspectives. Complete information for the fault features is extracted for the fault location. Based on a time series model and benefit from the ability to internally acquire the information architecture of faulty line, the established model is adaptive to the power grids with very complex topologies. Simulation results indicate that the proposed double-structure model reduces the maximum error and is less affected by noise. In comparison with different structures and different models, the proposed method shows better performance in IEEE 39-bus system.

42 ENGINEERING↗

Thermal and Mechanical Design of a High-Voltage Power Electronics Package

This paper presents the thermal and mechanical design aspects of a power electronics package with 5-kV GaN devices. Through finite element analyses, we investigated the impact of different cooling configurations and device locations on the thermal performance and reliability of the package. We found that placing the devices closer to the direct bond copper substrate as opposed to a centered approach in the proposed double-sided cooling configuration resulted in improved heat dissipation. This approach also reduced the total number of attachment layers, thereby likely improving the reliability of the package. Furthermore, simulations revealed that the device location had a negligible impact on the thermomechanical behavior of the attachment layers, as they are more prone to the local coefficient of thermal expansion mismatch.

electronic packaging↗

Multi-mode power split hybrid transmission with two planetary gear mechanisms

A multi-mode, power-split hybrid transmission system having two planetary gear (PG) sets connected to one engine, two electric motors, one output shaft, and each other by several clutches, brakes, and direct connection elements. Depending on the specific location and actuation of the various clutch and brake elements, the multi-mode, power-split hybrid transmission system can be run in one of several modes (e.g. electric drive, power-split, parallel hybrid, series hybrid, electronic continuously variable transmission (eCVT), generator, neutral, and the like).

33 ADVANCED PROPULSION SYSTEMS↗

More Powerful Twistron Carbon Nanotube Yarn Mechanical Energy Harvesters

We report that stretching a coiled carbon nanotube (CNT) yarn can provide large, reversible electrochemical capacitance changes, which convert mechanical energy to electricity. Here, it is shown that the performance of these “twistron” harvesters can be increased by optimizing the alignment of precursor CNT forests, plastically stretching the precursor twisted yarn, applying much higher tensile loads during precoiling twist than for coiling, using electrothermal pulse annealing under tension, and incorporating reduced graphene oxide nanoplates. The peak output power for a 1 and a 30 Hz sinusoidal deformation are 0.73 and 3.19 kW kg -1 , respectively, which are 24- and 13-fold that of previous twistron harvesters at these respective frequencies. This performance at 30 Hz is over 12-fold that of other prior-art mechanical energy harvesters for frequencies between 0.1 and 600 Hz. The maximum energy conversion efficiency is 7.2-fold that for previous twistrons. Twistron anode and cathode yarn arrays are stretched 180° out-of-phase by locating them in the negative and positive compressibility directions of hinged wine-rack frames, thereby doubling the output voltage and reducing the input mechanical energy.

36 MATERIALS SCIENCE↗

Non-Stationary Power System Forced Oscillation Analysis using Synchrosqueezing Transform

Non-stationary forced oscillations (FOs) have been observed in power system operations. However, most detection methods assume that the frequency of FOs is stationary. In this paper, we present a methodology for the analysis of nonstationary FOs. Firstly, Fourier synchrosqueezing transform (FSST) is used to provide a concentrated time-frequency representation of the signals that allows identification and retrieval of non-stationary signal components. To continue, the Dissipating Energy Flow (DEF) method is applied to the extracted components to locate the source of forced oscillations. The methodology is tested using simulated as well as real PMU data. In conclusion, the results show that the proposed FSST-based signal decomposition provides a systematic framework for the application of DEF Method to non-stationary FOs.

42 ENGINEERING↗

Designing, synthesizing, and modeling active fluids

We review recent advances in the design, synthesis, and modeling of active fluids. Active fluids have been at the center of many technological innovations and theoretical advances over the past two decades. Research on this new class of fluids has been inspired by the fascinating and remarkably efficient strategies that biological systems employ, leading to the development of biomimetic nano- and micro-machines and swimmers. The review encompasses active fluids on both the nano- and micro-scale. We start with examples of biological active systems before we discuss how experimentalists leverage novel propulsion mechanisms to power nano- and micro-machines. Furthermore, we then examine how the study of these far-from-equilibrium systems has prompted the development of new simulation methods and theoretical models in nonequilibrium physics to account for their mechanical, thermodynamic, and emergent properties. Recent advances in the field have paved the way for the design, synthesis, and modeling of autonomous systems at the nano- and micro-scale and opened the door to the development of soft matter robotics.

36 MATERIALS SCIENCE↗

Characterization and Optimization of the Fitting of Quantum Correlation Functions

This case study presents a characterization and optimization of an application code for extracting parton distribution functions from high energy electron-proton scattering data. Profiling this application code reveals that the phase-space density computation accounts for 93% of the overall execution time for a single iteration on a single core. When executing multiple iterations in parallel on a multicore system, the application spends 78% of its overall execution time idling due to load imbalance. We address these issues by first transforming the application code from Python to C++ and then tackling the application load imbalance via a hybrid scheduling strategy that combines dynamic and static scheduling. These techniques result in a 62% reduction in CPU idle time and a 2.46x speedup in overall execution time per node. In addition, the typically enabled power-management mechanisms in supercomputers (e.g., AMD Turbo Core, Intel Turbo Boost, and RAPL) can significantly impact intra-node scalability when more than 50% of the CPU cores are used. This finding underscores the importance of understanding system interactions with power management, as they can adversely impact application performance, and highlights the necessity of intra-node scaling tests to identify performance degradation that inter-node scaling tests might otherwise overlook.

Chuang, Pi-Yueh [Virginia Tech,Dept. of Computer S↗

Polarization-dependent conversion efficiency of carbon nanotube-Si heterojunction solar cells based on aligned carbon nanotube films

We have fabricated solar cells that implement heterojunctions of Si and aligned carbon nanotube (CNT) films. Polarization-dependent optical absorption of highly aligned CNTs led to polarization-dependent conversion efficiencies, which in turn provided insight into the role of the CNT layer in the power generation mechanism in these heterojunction solar cells. When the incident light polarization was parallel to the CNT alignment direction so that the light absorption in the CNT layer was maximized, the short circuit photocurrent decreased by ~25%. This indicates that electron–hole pair generation in the CNT layer does not directly lead to power generation and that the CNT-Si heterojunctions in our devices are Schottky junctions rather than p–n junctions.

Physics↗

BISON validation of FeCrAl cladding mechanical failure during simulated reactivity-initiated accident conditions*

Here, a reactivity-initiated accident (RIA) is a postulated design basis accident in light water reactors (LWRs) in which a rapid reactivity insertion induces a fission rate increase and a fuel pellet temperature rise. During RIA, the fuel pellet thermally expands and may cause pellet-cladding mechanical interaction (PCMI). Separate effects PCMI tests were performed on C26M FeCrAl cladding tube samples, introducing biaxial stress via a well understood modified burst test (MBT) system. A high-speed camera in the MBT system captured the projections, covering a 360° view of the cladding deformation and enabling a digital image correlation (DIC) method to quantify the surface strains with high fidelity. Representative hot zero-power RIA mechanical loading conditions were applied to the sample, and the test duration ranged from 20 to 500 ms at an average temperature of 573 K. BISON finite element–based fuel performance code modeling was performed against the high-fidelity DIC data produced from the MBTs. Validation calculations were conducted with 2D models and systematically compared with test data of the burst time, burst pressure, burst hoop strains, and hoop strain rates. Based on the behaviors from the separate effects test, BISON calculations satisfactorily predicted the cladding deformation behaviors. Sensitivity analysis was conducted to identify highly influential mechanical properties responsible for the cladding failure behavior during the MBT experiments. The results highlight the significance of the cladding's mechanical strength in governing cladding strain, followed by the significance of the mechanical interactions between the pellet and the cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Co-existence of Heterogeneous Wireless Networks in 2.4 GHz and 5 GHz Spectrum

To achieve automation across different applications, next-generation nuclear power plants are beginning to leverage advanced wireless technologies. The deployment of these wireless technologies is a salient need for modernizing the existing nuclear plants. A “one-size-fits-all” solution cannot be adopted since wireless technologies are selected according to specific application needs, quality of service, and economic restrictions. To balance the trade-off between technical and economic requirements, a multi-band heterogeneous wireless network architecture is needed. However, the co-existence of these multi-band wireless technologies poses numerous challenges. Due to factors including dissimilarity in channel access mechanisms, transmit power levels, distance between nodes, and interference among co-existing solutions, performance can be seriously degraded, leading to very low signal-to-noise ratio. This report builds on our previous study, "Experimental Evaluation of Interference in 2.4 GHz Wireless Network," which analyzed the performance of wireless communication technologies such as Wi-Fi, Zigbee, and Bluetooth co-existing within the 2.4 GHz band. We now extend this study by developing a new upper-layer approach that uses rate control to create temporary opportunities for signal transmission while using the shared band. Unlike existing work in the literature, our approach does not require modifications at the link or physical layers of the network. Further, we extend our work to explore the co-existence of Wi-Fi and fifth-generation (5G) in the 5 GHz unlicensed spectrum, using both experiments and simulations. This report provides a technical foundation for understanding the operational designs of Wi-Fi and 5G in the unlicensed band and evaluates their performance when these networks co-exist. Our findings show that the performance of 5G can be improved by controlling the Wi-Fi’s packet rate at the upper layer.

42 ENGINEERING↗