SEARCH · Engineering Papers

Results for “Measurement_method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Beginner's Guide to Power and Energy Measurement and Estimation for Computing and Machine Learning

Concerns about the environmental footprint of machine learning are increasing. While studies of energy use and emissions of ML models are a growing subfield, most ML researchers and developers still do not incorporate energy measurement as part of their work practices. While measuring energy is a crucial step towards reducing carbon footprint, it is also not straightforward. This paper introduces the main considerations necessary for making sound use of energy measurement tools and interpreting energy estimates, including the use of at-the-wall versus on-device measurements, sampling strategies and best practices, common sources of error, and proxy measures. It also contains practical tips and real-world scenarios that illustrate how these considerations come into play. It concludes with a call to action for improving the state of the art of measurement methods and standards for facilitating robust comparisons between diverse hardware and software environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electronics Free Laser Sensing Technology for Minerals and Technology Elements

This presentation presents an electronics free laser sensing technique and its ongoing and potential applications. A laser-based technique, popularly known as laser-induced breakdown spectroscopy has been prototyped for the determination of high-tech elements including rare earth elements and other elements in solid as well as aqueous sources. All optical unit without any electronics has been designed in such a way that it can be installed in the source environment and connected to other required components for controlling and data acquisition from the workstation. Measurement methods and results obtained for selected elemental species and overall performance of the developed prototype will be presented.

HCM Sensor↗

Variation in surface properties as error sources in dynamic temperature measurements

Most temperature measurement methods rely upon the assumption of a single uniform source as part of the analysis in inferring an observed temperature T from the surface of a material. This is true for the radiometric and spectroscopic methods we rely upon in shock physics. However, there are obvious cases where this is a poor assumption that can cause large errors in analysis, such as the measurement of emission from a surface composed of more than one material, such as a rusted surface of Fe and Fe 2 O 3 , or a multi-material surface that could be produced through alloying methods (e.g., mokume gane) or 3D printing. Here we perform an initial examination of the effects of varied surface properties upon the analysis using idealized test data to constrain when we may have better confidence in the resulting calculations. We also examine the structures of the fits to test whether, in principle, comparing the fit with ideal gray bodies would reveal such a structure and enable the researcher to identify when a two-temperature fitting model should be used instead of a single- T model or a wavelength-dependent emissivity model.

36 MATERIALS SCIENCE↗

Mechanical Characterization of the NIF Ignition Target TMPSA Bonding Flexure

The Thermo-Mechanical Package Sub-Assembly (TMPSA) provides a critical mechanical, thermal, and electrical interface between a silicon arm and a TMP aluminum can in a NIF ignition target. During assembly, sixteen silicon pads are bonded to the aluminum using a fixture that positions the components and applies a repeatable prescribed displacement through a compliant flexure. The flexure converts fixture interference into displacement and reaction force. Because bondline thickness variation must be maintained within +/-4 µm, consistent flexure behavior is important to the assembly process. With a recent string of TMPSAs exhibiting low bond strength, the flexures were inspected. Despite being manufactured to the same specifications, flexures were found to exhibit variation in measured stiffness. Additionally, the measured stiffness values did not always follow the presumed beam mechanics model. This work addresses two questions: whether the bonding fixture is working as intended, and whether the previously made stiffness measurements are accurate representations of the use case. The flexures are analyzed using Euler-Bernoulli beam theory, measured beam dimensions, finite element analysis, and tolerance stack-up calculations. The analysis shows that the fixed-guided beam mechanics model appropriately represents the flexure during TMPSA bonding, but the chisel-tip stiffness measurement method introduces a deformation to the inner ring of the flexure that is not represented during use. The measured stiffness values should therefore be interpreted as test-condition stiffness values rather than direct measurements of operational flexure stiffness. The discrepancy is therefore attributed primarily to the measurement boundary condition rather than to failure of the fixed-guided beam model. Recommendations are provided for GD&T, dimensional inspection, and a representative stiffness testing method to better control bondline variation.

42 ENGINEERING↗

Aerosol Hygroscopic Growth, Mixing State, and Cloud Condensation Nuclei Activity during TRACER (Field Campaign Report)

Convective clouds play a critical role in the Earth’s climate system. Recent research has shown that a realistic representation of convective processes is critical to constraining climate sensitivity in global climate models. Theoretical and modeling studies showed that aerosols could have strong dynamic feedback to convection in warm and humid environments through enhancing ice-related processes and condensational growth. A few observation-based studies also suggested the influence of aerosols on convective cloud and precipitation properties. However, robust observational quantification of an aerosol effect on convective clouds isolated from other factors remains elusive. Understanding the impact of aerosol on convective clouds requires knowledge of the cloud condensation nuclei (CCN) spectrum, which represents the number of particles that uptake water and form cloud droplets as a function of supersaturation. The water uptake by aerosol is also of critical importance for the direct interaction of aerosol with radiation (i.e., aerosol direct effect) due to light scattering and absorption by aerosol. While both droplet activation under supersaturated conditions (i.e., relative humidity RH > 100%) and the hygroscopic growth under sub-saturated conditions (i.e., RH < 100%) are strongly influenced by particle hygroscopicity, the thermodynamic regimes and measurement methods are quite different. Aerosol particles, especially organic particles, can exhibit higher hygroscopicity for droplet activation than that for hygroscopic growth. In the subsaturated regime, the hygroscopicity of organic particles can also vary strongly with RH. However, global climate models usually treat organic species in aerosols with a constant hygroscopicity, potentially introducing substantial uncertainties in the quantification of aerosol radiative effects.

54 ENVIRONMENTAL SCIENCES↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗

Methods for Incorporating Model Uncertainty into Exoplanet Atmospheric Analysis

A key goal of exoplanet spectroscopy is to measure atmospheric properties, such as abundances of chemical species, in order to connect them to our understanding of atmospheric physics and planet formation. In this new era of high-quality JWST data, it is paramount that these measurement methods are robust. When comparing atmospheric models to observations, multiple candidate models may produce reasonable fits to the data. Typically, conclusions are reached by selecting the best-performing model according to some metric. This ignores model uncertainty in favor of specific model assumptions, potentially leading to measured atmospheric properties that are overconfident and/or incorrect. In this paper, we compare three ensemble methods for addressing model uncertainty by combining posterior distributions from multiple analyses: Bayesian model averaging, a variant of Bayesian model averaging using leave-one-out predictive densities, and stacking of predictive distributions. We demonstrate these methods by fitting the Hubble Space Telescope (HST) + Spitzer transmission spectrum of the hot Jupiter HD 209458b using models with different cloud and haze prescriptions. All of our ensemble methods lead to uncertainties on retrieved parameters that are larger but more realistic and consistent with physical and chemical expectations. Since they have not typically accounted for model uncertainty, uncertainties of retrieved parameters from HST spectra have likely been underreported. We recommend stacking as the most robust model combination method. Our methods can be used to combine results from independent retrieval codes and from different models within one code. They are also widely applicable to other exoplanet analysis processes, such as combining results from different data reductions.

79 ASTRONOMY AND ASTROPHYSICS↗

Summertime methane and carbon dioxide emission rates and associated variables from a national-scale survey of 146 reservoirs in the United States, 2016-2023

Reservoirs are globally important sources of greenhouse gases, but the magnitude of their emissions is highly uncertain. Here we present data for 146 reservoirs from two surveys of reservoir methane and carbon dioxide emissions, one at the regional scale in the midwestern United States and one at the national scale in the conterminous United States, plus data from one reservoir in Washington and another in Puerto Rico. At all reservoirs, ebullitive and diffusive emissions and basic physiochemistry were measured at 15-70 locations during one 22 to 64-hour period during the summers of 2016-2023, with four reservoirs revisited a second time. Concomitant water chemistry measurements were also made at an index site. The dataset is comprised of two geospatial files and seven .csv files containing greenhouse gas emissions, water chemistry, morphology, and other relevant data. These data comprise the largest multi-reservoir emissions dataset ever assembled using consistent measurement methods.

Beaulieu, Jake [University of Notre Dame, IN]↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems and methods for dual comb spectroscopy

A frequency-measurement method uses a dual frequency-comb spectrometer as an optical wavemeter to measure the frequency of a reference laser that is used to frequency-stabilize the spectrometer. The method includes measuring a walking rate of center bursts in a sequence of interferograms recorded by the spectrometer, determining a number of teeth in each of a plurality of Nyquist windows formed by the dual frequency-comb spectrometer, and determining a Nyquist number of the one Nyquist window covering the laser frequency. The reference laser frequency can then be determined from the number of teeth in each Nyquist window, the Nyquist number, and the comb spacing of either one of the two frequency combs of the dual frequency-comb spectrometer. The reference laser frequency does not need to be measured with a separate wavemeter, or calibrated with respect to a known atomic or molecular transition.

Rieker, Gregory B.↗

Quantifying Burst Repeatability for Godiva IV

The minimum resolvable relative change in the neutron source emission of Godiva IV between bursts, i.e., burst repeatability, was quantified using a combination of activation monitors and a resistance temperature detector (RTD). Measurements support changes in the neutron source emission between bursts can be determined with a precision of 2.7%. The measurements were performed during a series of twelve Godiva IV bursts and were a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratories, and Pacific Northwest National Laboratory. Gold, iron, nickel, and sulfur activation monitors were positioned in a sample holder in the central cavity of Godiva IV for each burst. The RTD is part of the Godiva burst diagnostic system and is in a fixed location in the safety block of Godiva IV. It is used to determine the temperature rise of the burst, i.e., the difference between the maximum temperature recorded during the burst and the initial temperature prior to the burst. Differences in either the specific activity of the activation monitor reactions, or the temperature rise can be used to determine the relative change in the neutron source emission for separate bursts, but historic results have proven that each method is susceptible to various sources of biases which generally cannot be isolated using a single method. We address this issue by applying both measurement methods and analyzing the correlation between them. The results presented in this work will be used to support future experiments with Godiva IV at the National Criticality Experiments Research Center (NCERC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low Energy Muon Beam Diagnostics: Scintillating Fiber Profile Monitor

The MeV Test Area (MTA) houses the 400 MeV H- Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam’s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Demonstration and Automation of Reflected Target Optical Measurement for Heliostats

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. Since 2022, NREL has been developing a measurement method called the Reflected Target Non-intrusive Assessment (ReTNA) system. This system differs from most established methods in that we perform deflectometry with a pattern of coded targets, identified in space with photogrammetry. Reflected target systems have several advantages over traditional fringe deflectometry systems. Firstly, they can be operated in bright or ambient lighting, a challenge for fringe systems that use a projector and screen. Reflected target systems also can use a much lighter and less expensive target than projector-based systems. Lastly, 2D slope measurement can be solved from a single image, which leads to several advantages for accommodating faster measurements and smaller sized targets. These advantages make ReTNA particularly well-suited for applications where there are space or lighting constraints, like performing heliostat quality assurance on an assembly line. It's also useful when a lightweight, flexible system is needed, like for heliostat developers to quickly measure a new heliostat design at different orientations, to observe gravitational effects on the mirror surface shape. In the last year, significant improvements were made to this tool to make it more useful for these applications. These improvements were focused around validation of the ReTNA measurement system, and automation of the setup and measurement process. First, we present an improved ReTNA layout, for use on the heliostat assembly line. Next, we detail the various changes to the ReTNA software and computer vision methods to automate data collection in this new setup, and lessons learned from this process. The goal with this new setup is to perform a full heliostat surface characterization without removing the mirror from the assembly line. Lastly, we share results from several ReTNA validation studies undertaken over the last year. These include repeated ReTNA measurement on demonstration mirror facets, comparisons with other optical measurement tools, and some studies aimed at quantifying the uncertainty of ReTNA measurement under various constraints (mirror-target spacing, camera resolution, etc.). These results are compared with 2024 HelioCon performance targets, and our planned next steps for the ReTNA measurement system are presented.

CSP↗

Effects of Size on Characteristics of Electroslag Remelted (ESR) HAYNES®282® alloy ingots

The effects of varying ingot diameters on the characteristics of round ESR ingots of 282 alloy are evaluated through a combined experimental and modeling study. Ingots of four different diameters --100 mm, 150 mm, 200 mm and 500 mm, were sectioned and analyzed using metallography to assess spatial variations in dendritic structure (primary / secondary dendrite arm spacings – PDAS/SDAS) across these ingots. Melt parameters of the processes were input into the simulation code, MeltFlow-ESR™ to theoretically predict PDAS/SDAS in the ingots. The values for PDAS/SDAS predicted by the simulations are compared with those measured by experiments and quantitative differences in these values are discussed in the context of the capability and limitations of the model and measurement methods. Both the predicted and measured values show that the PDAS/SDAS values increase with increasing ingot size. In addition, the relation with other ingot characteristics, such as local solidification time as well as the likelihood for freckle formation are discussed. The implication of these results for down-stream ingot processing and for ingot soundness are discussed.

Krishnamurthy, Ramanathan↗

Brillouin Sensing with PCA, and PCA-Based Neural Networks for Efficient Temperature Monitoring

This work explores peak estimation techniques in Brillouin Optical Time Domain Analysis (BOTDA), emphasizing both accuracy and efficiency. Euclidean distance measurement method is applied to principal components derived from Brillouin Gain Spectrum data. It offers a major speed advantage being 180 170 times faster than traditional curve fitting methods such as Lorentzian curve fitting, while maintaining similar accuracy. Additionally, a PCA- based neural network model shows significant reduction of peak estimation time compared to Lorentzian fitting. Results show Brillouin frequency shift errors lie under 0.75 MHz in both Euclidean distance-based and neural network-based methods, both of which utilize PCA components. For large data sets and long length fibers, PCA- assisted neural network for peak estimation would be an efficient solution.

Distributed optical fiber sensing↗

Location Identifiers, Metadata, and Map for Field Measurements at the East-Taylor Watershed Community Observatory, Colorado, USA (Version 3.3)

This dataset contains identifiers, metadata, and a map of the locations where field measurements have been conducted at the East-Taylor Watershed Community Observatory located in the Upper Colorado River Basin, United States. This is version 3.3 of the dataset and replaces the prior version 3.2 (see below for details on changes between the versions). Dataset description: The East River-Taylor Watershed is the primary field site of the Watershed Function Scientific Focus Area (WFSFA) and the Rocky Mountain Biological Laboratory. Researchers from several institutions generate highly diverse hydrological, biogeochemical, climate, vegetation, geological, remote sensing, and model data at the East-Taylor Watershed in collaboration with the WFSFA. Thus, the purpose of this dataset is to maintain an inventory of the field locations and instrumentation to provide information on the field activities in the East-Taylor Watershed and coordinate data collected across different locations, researchers, and institutions. The dataset contains (1) a README file with information on the various files, (2) three csv files describing the metadata collected for each surface point location, plot and region registered with the WFSFA, (3) csv files with metadata and contact information for each surface point location registered with the WFSFA, (4) a csv file with with metadata and contact information for plots, (5) a csv file with metadata for geographic regions and sub-regions within the watershed, (6) a compiled xlsx file with all the data and metadata which can be opened in Microsoft Excel, (7) a kml map of the locations plotted in the watershed which can be opened in Google Earth, (8) a jpg image of the kml map which can be viewed in any photo viewer, and (9) a zipped file with the registration templates used by the SFA team to collect location metadata. The zipped template file contains two csv files with the blank templates (point and plot), two csv files with instructions for filling out the location templates, and one compiled xlsx file with the instructions and blank templates together. Additionally, the templates in the xlsx include drop down validation for any controlled metadata fields. Persistent location identifiers (Location_ID) are determined by the WFSFA data management team and are used to track data and samples across locations. Dataset uses: This location metadata is used to update the Watershed SFA’s publicly accessible Field Information Portal (an interactive field sampling metadata exploration tool; https://wfsfa-data.lbl.gov/watershed/), the kml map file included in this dataset, and other data management tools internal to the Watershed SFA team. Version Information: The latest version of this dataset publication is version 3.3. This version contains 167 new point locations, 1 new plot, and 2 new geographic regions. Overall, there are a total of 1439 point locations, 75 plots, and 54 geographic regions. Additionally, the kml map of locations and image now includes two boundaries (Upper Ohio Creek (UO) and Carbon Creek (CA)) outside of the East River watershed (USGS HUC-10) and accompanying stream network that represents areas of focus. Refer to methods for further details on the version history. This dataset will be updated on a periodic basis with new measurement location information. Researchers interested in having their East-Taylor Watershed measurement locations added to this list should reach out to the WFSFA data management team at wfsfa-data@googlegroups.com. Acknowledgments: Please cite this dataset if using any of the location metadata in other publications or derived products. If using the location metadata for the 2018 NEON hyperspectral campaign, additionally cite Chadwick et al. (2020). doi:10.15485/1618130. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

2018 NEON and 2025 CHESS Campaigns↗

Studies of Laser-Driven Flyer Acceleration Using Optical Fiber Coupling [Book Chapter]

An optically recording velocity interferometer system has been used to measure acceleration histories and maximum velocities for laser-driven aluminum foil targets launched from the output face of optical fibers. Peak flyer velocities have been determined as a function of various parameters, including driving laser fluence, laser pulse duration and target thickness. The results at high fluences are consistent with a nearly constant efficiency of coupling optical energy into flyer kinetic energy and a small ablated mass fraction; however, the coupling efficiency falls off rapidly at fluences < 15 J-cm -2 . Measurement of the time delay between laser pulse arrival at the target and the onset of flyer motion have also been performed. Significant delays are observed at low fluences, arising from the increased time required for plasma formation at the fiber/foil interface under these conditions.

440600 -- Optical Instrumentation-- (1990-)↗

An improved method for quantitatively measuring antifouling coating performance using a mussel single thread tensile adhesion test

Surface biofouling reduces the efficiency and lifespan of equipment across many industries. The development of high-performance antifouling surfaces, such as foul release coatings, benefits from test methods that can quickly identify superior antifouling surfaces in the laboratory during material development. Existing test methods poorly discriminate between different foul release coatings. Here is presented a method to assess the ability of surfaces to resist mussel adhesion using a quantitative, controlled single thread adhesion test (STAT) method, allowing for meaningful comparisons between low adhesion foul release surfaces. This method provides greater accuracy and finer resolution than push-based mussel shear adhesion methods without the difficulties associated with mussel size, thread attachment angle, or harming the mussels. The single thread tensile method is demonstrated on a variety of standard and high-performance coatings, and it is shown that the method detects differentiation between commercial foul release coatings that could not be resolved using other methods.

42 ENGINEERING↗