Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-precision Penning trap mass measurements of neutron-rich chlorine isotopes at the 𝑁 = 28 shell closure

Although it is known that the N = 28 spherical shell closure erodes, the strength of the closure with decreasing proton number Z < 20 is an open question in nuclear structure. Here, in this region of interest, high-precision mass measurements of neutron-rich 43-45 Cl isotopes were performed at the Low Energy Beam and Ion Trap (LEBIT) when coupled to the National Superconducting Cyclotron Lab. The resulting mass excesses (MEs) are ME(⁴³Cl) = -24114.4(1.7) keV, ME(⁴⁴Cl) = -20450.8(10.6) keV, and ME(⁴⁵Cl) = -18240.1(3.7) keV, and improve the uncertainty of these masses by up to a factor of ∼40 compared to the previous values reported in the 2020 Atomic Mass Evaluation. Comparison to ab initio calculations using the Valence-Space In-Medium Similarity Renormalization Group (VS-IMSRG) shows good agreement up to and including the closure.

Erington, H. [Michigan State Univ., East Lansing, ↗

Direct Mass Measurements to Inform the Behavior of 128m $\mathrm{Sb}$ in Nucleosynthetic Environments

Nuclear isomer effects are pivotal in understanding nuclear astrophysics, particularly in the rapid neutron-capture process where the population of metastable isomers can alter the radioactive decay paths of nuclei produced during astrophysical events. The β-decaying isomer 128m Sb was identified as potentially impactful since the β-decay pathway along the A = 128 isobar funnels into this state bypassing the ground state. Here we report the first direct mass measurements of the 128 Sb isomer and ground state using the Canadian Penning Trap mass spectrometer at Argonne National Laboratory. We find mass excesses of -84564.8(25) keV and -84608.8(21) keV, respectively, resulting in an excitation energy for the isomer of 43.9(33) keV. These results provide the first key nuclear data input for understanding the role of 128m Sb in nucleosynthesis, and we show that it will influence the flow of the rapid neutron-capture process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the ATLAS top mass measurements and the potential for stealth stop contamination

The discovery of the stop — the Supersymmetric partner of the top quark — is a key goal of the physics program enabled by the Large Hadron Collider. Although much of the accessible parameter space has already been probed, all current searches assume the top mass is known. This is relevant for the “stealth stop” regime, which is characterized by decay kinematics that force the final state top quark off its mass shell; such decays would contaminate the top mass measurements. We investigate the resulting bias imparted to the template method based ATLAS approach. A careful recasting of these results shows that effect can be as large as 2.0 GeV, comparable to the current quoted uncertainty on the top mass. Thus, a robust exploration of the stealth stop splinter requires the simultaneous consideration of the impact on the top mass. Additionally, we explore the robustness of the template technique, and point out a simple strategy for improving the methodology implemented for the semi-leptonic channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physiological mass measurements in Skylab

A spring-mass oscillator constrained to linear motion was used to measure astronaut weight during Skylab mission. Plots of spacecrew body weights, preflight and postflight, and inflight equivalent weight measurements indicate high in-flight metabolic costs with weight losses under weightlessness conditions.

Thornton, W. E.↗

K2-79b and K2-222b: Mass Measurements of Two Small Exoplanets with Periods beyond 10 days that Overlap with Periodic Magnetic Activity Signals

We present mass and radius measurements of K2-79b and K2-222b, two transiting exoplanets orbiting active G-type stars observed with HARPS-N and K2. Their respective 10.99 day and 15.39 day orbital periods fall near periods of signals induced by stellar magnetic activity. The two signals might therefore interfere and lead to an inaccurate estimate of exoplanet mass. We present a method to mitigate these effects when radial velocity (RV) and activityindicator observations are available over multiple observing seasons and the orbital period of the exoplanet is known. We perform correlation and periodogram analyses on subsets composed of each target's two observing seasons, in addition to the full data sets. For both targets, these analyses reveal an optimal season with little to no interference at the orbital period of the known exoplanet. We make a confident mass detection of each exoplanet by confirming agreement between fits to the full RV set and the optimal season. For K2-79b, we measure a mass of 11.8 ± 3.6 M ⊕ and a radius of 4.09 ± 0.17 R ⊕ . For K2-222b, we measure a mass of 8.0 ± 1.8 M ⊕ and a radius of 2.35 ± 0.08 R ⊕ . According to model predictions, K2-79b is a highly irradiated Uranus analog and K2-222b hosts significant amounts of water ice. We also present a RV solution for a candidate second companion orbiting K2-222 at 147.5 days.

79 ASTRONOMY AND ASTROPHYSICS↗

Speculations on the W-mass measurement at CDF*

Abstract The W mass determination at the Tevatron CDF experiment reported a deviation from the SM expectation at the 7 σ level. We discuss a few possible interpretations and their collider implications. We perform electroweak global fits under various frameworks and assumptions. We consider three types of electroweak global fits in the effective-field-theory framework: the S - T , S - T - , and eight-parameter flavor-universal one. We discuss the amounts of tensions between different measurements reflected in these fits and the corresponding shifts in central values of these parameters. With these electroweak fit pictures in hand, we present a few different classes of models and discuss their compatibility with these results. We find that while explaining the discrepancy, the single gauge boson extensions face strong LHC direct search constraints unless the is fermiophobic (leptophobic), which can be realized if extra vector fermions (leptons) mix with the SM fermions (leptons). Vector-like top partners can partially generate the needed shift to the electroweak observables. The compatibility with the top squark is also studied in detail. We find that the non-degenerate top squark soft masses enhance the needed operator coefficients, enabling an allowed explanation compatible with current LHC measurements. Overall, more theoretical and experimental developments are highly in demand to reveal the physics behind this discrepancy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching for the origin of the rare-earth peak with precision mass measurements across Ce–Eu isotopic chains

A nuclear mass survey of rare-earth isotopes has been conducted with the Canadian Penning Trap mass spectrometer using the most neutron-rich nuclei thus far extracted from the CARIBU facility. Here, we present a collection of 12 nuclear masses determined with a precision of ≤ 10 keV/c 2 for Z = 58-63 nuclei near N = 100. Independently, a detailed study exploring the role of nuclear masses in the formation of the r-process rare-earth abundance peak has been performed. Employing a Markov chain Monte Carlo (MCMC) technique, mass predictions of lanthanide isotopes have been made which uniquely reproduce the observed solar abundances near A = 164 under three distinct astrophysical outflow conditions. We demonstrate that the mass surface trends thus far mapped out by our measurements are most consistent with MCMC mass predictions given an r process that forms the rare-earth peak during an extended (n, γ) ⇌ (γ, n) equilibrium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capacitive Sensors for Measuring Masses of Cryogenic Fluids

An effort is under way to develop capacitive sensors for measuring the masses of cryogenic fluids in tanks. These sensors are intended to function in both microgravitational and normal gravitational settings, and should not be confused with level sensors, including capacitive ones. A sensor of this type is conceptually simple in the sense that (1) it includes only one capacitor and (2) if properly designed, its single capacitance reading should be readily convertible to a close approximation of the mass of the cryogenic fluid in the tank. Consider a pair of electrically insulated electrodes used as a simple capacitive sensor. In general, the capacitance is proportional to the permittivity of the dielectric medium (in this case, a cryogenic fluid) between the electrodes. The success of design and operation of a sensor of the present type depends on the accuracy of the assumption that to a close approximation, the permittivity of the cryogenic fluid varies linearly with the density of the fluid. Data on liquid nitrogen, liquid oxygen, and liquid hydrogen, reported by the National Institute of Standards and Technology, indicate that the permittivities and densities of these fluids are, indeed, linearly related to within a few tenths of a percent over the pressure and temperature regions of interest. Hence, ignoring geometric effects for the moment, the capacitance between two electrodes immersed in the fluid should vary linearly with the density, and, hence, with the mass of the fluid. Of course, it is necessary to take account of the tank geometry. Because most cryogenic tanks do not have uniform cross sections, the readings of level sensors, including capacitive ones, are not linearly correlated with the masses of fluids in the tanks. In a sensor of the present type, the capacitor electrodes are shaped so that at a given height, the capacitance per unit height is approximately proportional to the cross-sectional area of the tank in the horizontal plane at that height (see figure).

Nurge, Mark↗

Towards a combination of LHC and TeVatron W-boson mass measurements

In this note methodological and modelling considerations towards a combination of the ATLAS, CDF and D0 measurements of the W -boson mass are discussed. As they were performed at different moments in time, each measurement employed different assumptions for the modelling of W -boson production and decay, as well as different fits of the parton distribution functions of the proton (PDFs). Methods are presented to accurately evaluate the effect of PDFs and other modelling variations on existing measurements, allowing to extrapolate them to any PDF set and to evaluate the corresponding uncertainties. Based on this approach, the measurements can be corrected to a common modelling reference and to the same PDFs, and subsequently combined accounting for PDF correlations in a quantitative way.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A mathematical framework for ejecta cloud dynamics with application to source models and piezoelectric mass measurements

We present a mathematical framework for describing the dynamical evolution of an ejecta cloud generated by a generic ejecta source model. We consider a piezoelectric sensor fielded in the path of an ejecta cloud, for experimental configurations in which the ejecta are created at a singly shocked planar surface and fly ballistically through vacuum to the stationary sensor. To do so, we introduce the concept of a time- and velocity-dependent ejecta “areal mass function.” We derive expressions for the analytic (“true”) accumulated ejecta areal mass at the sensor and the measured (“inferred”) value obtained via the standard method for analyzing piezoelectric voltages. In this way, we derive an exact expression and upper bound for the error imposed upon a piezoelectric ejecta mass measurement (in a perfect system) by the assumption of instantaneous creation, which is commonly required for momentum diagnostic analyses. This error term is zero for truly instantaneous source models; otherwise, the standard piezoelectric analysis is guaranteed to overestimate the true mass. When combined with a piezoelectric dataset, this framework provides a unique solution for the ejecta particle velocity distribution, subject to the assumptions inherent in the data analysis. The framework also leads to strong boundary conditions that any ejecta source model must satisfy in order to be consistent with apparently global properties of piezoelectric measurements from a wide range of experiments. We demonstrate this methodology by applying it to the Richtmyer–Meshkov instability+self-similar velocity distribution ejecta source model currently under development at Los Alamos National Laboratory.

97 MATHEMATICS AND COMPUTING↗

Secure Mass Measurements From Transit Timing: 10 Kepler Exoplanets Between 3 and 8M⊕ with Diverse Densities and Incident Fluxes

We infer dynamical masses in eight multiplanet systems using transit times measured from Keplerʼs complete dataset, including short-cadence data where available. Of the 18 dynamical masses that we infer, 10 pass multiple tests for robustness. These are in systems Kepler-26 (KOI-250), Kepler-29 (KOI-738), Kepler-60 (KOI-2086), Kepler-105 (KOI-115), and Kepler-307 (KOI-1576). Kepler -105 c has a radius of 1.3R⊕ and a density consistent with an Earth-like composition. Strong transit timing variation (TTV) signals were detected from additional planets, but their inferred masses were sensitive to outliers or consistent solutions could not be found with independently measured transit times, including planets orbiting Kepler-49 (KOI-248), Kepler-57 (KOI-1270), Kepler-105 (KOI-115), and Kepler-177 (KOI-523). Nonetheless, strong upper limits on the mass of Kepler-177 cimply an extremely low density of 0.1 g cm−3. In most cases, individual orbital eccentricities were poorly constrained owing to degeneracies in TTV inversion. For five planet pairs in our sample, strong secular interactions imply a moderate to high likelihood of apsidal alignment over a wide range of possible eccentricities. We also find solutions for the three planets known to orbit Kepler-60 in a Laplace-like resonance chain. However, nonlibrating solutions also match the transit timing data. For six systems, we calculate more precise stellar parameters than previously known, enabling useful constraints on planetary densities where we have secure mass measurements. Placing these exoplanets on the mass–radius diagram, we find that a wide range of densities is observed among sub-Neptune-mass planets and that the range in observed densities is anticorrelated with incident flux.

Stars individual↗

Secure Mass Measurements From Transit Timing: 10 Kepler Exoplanets Between 3 and 8 M⊕ With Diverse Densities and Incident Fluxes

We infer dynamical masses in eight multiplanet systems using transit times measured from Keplerʼs complete data set, including short-cadence data where available. Of the 18 dynamical masses that we infer, 10 pass multiple tests for robustness. These are in systems Kepler-26 (KOI-250), Kepler-29 (KOI-738), Kepler-60 (KOI-2086), Kepler-105 (KOI-115), and Kepler-307 (KOI-1576). Kepler-105 c has a radius of 1.3 R(sub ⨁) and a density consistent with an Earth-like composition. Strong transit timing variation (TTV) signals were detected from additional planets, but their inferred masses were sensitive to outliers or consistent solutions could not be found with independently measured transit times, including planets orbiting Kepler-49 (KOI-248), Kepler-57 (KOI-1270), Kepler-105 (KOI-115), and Kepler-177 (KOI-523). Nonetheless, strong upper limits on the mass of Kepler-177 c imply an extremely low density of ∽0.1 g cm(exp −3). In most cases, individual orbital eccentricities were poorly constrained owing to degeneracies in TTV inversion. For five planet pairs in our sample, strong secular interactions imply a moderate to high likelihood of apsidal alignment over a wide range of possible eccentricities. We also find solutions for the three planets known to orbit Kepler-60 in a Laplace-like resonance chain. However, nonlibrating solutions also match the transit timing data. For six systems, we calculate more precise stellar parameters than previously known, enabling useful constraints on planetary densities where we have secure mass measurements. Placing these exoplanets on the mass–radius diagram, we find that a wide range of densities is observed among sub-Neptune-mass planets and that the range in observed densities is anticorrelated with incident flux.

Individual stars↗

Mass measurements of neutron-rich nuclei near $N = 70$

The astrophysical origin for the chemical elements between the first and second r-process peaks is a matter of intense debate, with a number of nucleosynthesis processes at explosive stellar environments possibly contributing to their production. Reliable data on the trends of neutron separation energies of neutron-rich isotopes are required to model neutron-capture processes that would produce these elements. Masses of 104 Y, 106 Zr, 112 Mo, and 115 Tc have been measured with the time-of-flight-magnetic-rigidity (ToF–Bρ) technique at the National Superconducting Cyclotron Laboratory at Michigan State University. The experiment is the first application of the ToF–Bρ technique at the S800 spectrograph that reached the mass region relevant to heavy-element nucleosynthesis. Finally, the two-neutron separation energy deduced from the measured masses exhibits a smooth trend consistent with the theoretical predictions within the range of experimental uncertainty, indicating that there is no sudden shape transition in these isotopes as hinted at by previous data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analytic solutions for Asay foil trajectories with implications for ejecta source models and mass measurements

We consider the trajectory of an Asay foil ejecta diagnostic for scenarios where ejecta are produced at a singly shocked planar surface and fly ballistically through a perfect vacuum to the sensor. We do so by building upon a previously established mathematical framework derived for the analytic study of stationary sensors. First, we derive the momentum conservation equation for the problem, in a form amenable to accelerating sensors, in terms of a generic ejecta source model. The result is an integrodifferential equation of motion for the foil trajectory. This equation yields an easily calculable closed-form implicit solution for the foil trajectory in instant-production scenarios. From there, we derive a boundary condition that particle velocity distributions must satisfy if their associated foil trajectories are to exhibit a smooth initial acceleration, as occurs in some experiments. This condition is identical to one derived previously from a consideration of piezoelectric voltage data obtained in similar experiments. We also compare techniques for inferring accumulated ejecta masses from foil trajectories, first by deriving the exact solution, and then by quantifying the error imposed by a frequently used approximate solution (both subject to the assumption of instantaneous ejecta production). Finally, we examine the common practice of presenting inferred cumulative ejecta masses as a function of implied ejecta velocity, establishing the conditions under which this methodology is most meaningful.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct neutrino-mass measurement based on 259 days of KATRIN data

That neutrinos carry a nonvanishing rest mass is evidence of physics beyond the Standard Model of elementary particles. Their absolute mass holds relevance in fields from particle physics to cosmology. We report on the search for the effective electron antineutrino mass with the KATRIN experiment. KATRIN performs precision spectroscopy of the tritium β-decay close to the kinematic endpoint. On the basis of the first five measurement campaigns, we derived a best-fit value of $m^{2}_{v} = -0.14^{+0.13}_{-0.15}$ eV 2 , resulting in an upper limit of m ν < 0.45 eV at 90% confidence level. Stemming from 36 million electrons collected in 259 measurement days, a substantial reduction of the background level, and improved systematic uncertainties, this result tightens KATRIN’s previous bound by a factor of almost two.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of Cabibbo-Suppressed Two-Body Hadronic Decays and Precision Mass Measurement of the Ω c 0 Baryon

The first observation of the singly Cabibbo-suppressed Ω c 0 → Ω − K + and Ω c 0 → Ξ − π + decays is reported, using proton-proton collision data at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 5.4 fb − 1 , collected with the LHCb detector between 2016 and 2018. The branching fraction ratios are measured to be B ( Ω c 0 → Ω − K + ) B ( Ω c 0 → Ω − π + ) = [ 6.08 ± 0.51 ( stat ) ± 0.40 ( syst ) ] % , B ( Ω c 0 → Ξ − π + ) B ( Ω c 0 → Ω − π + ) = [ 15.81 ± 0.87 ( stat ) ± 0.44 ( syst ) ± 0.16 ( ext ) ] % . In addition, using the Ω c 0 → Ω − π + decay channel, the Ω c 0 baryon mass is measured to be M ( Ω c 0 ) = 2695.28 ± 0.07 ( stat ) ± 0.27 ( syst ) ± 0.30 ( ext ) MeV , improving the precision of the previous world average by a factor of 4. © 2024 CERN, for the LHCb Collaboration 2024 CERN

Aaij, R. (ORCID:0000000305331952)↗