Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

69 records · Page 4

Mucus-Inspired Tribology, a Sticky Yet Flowing Hydrogel

The mucus blanket can trap foreign particles before they enter the lungs, while at the same time, it flows up to remove these particles. This manifests the dual nature of mucus: sticky, on one hand, and fluid, on the other. Inspired by this function of mucus in the lungs, we designed a mucus simulant which emulates this dual nature. While many existing mucus simulants do not target bioadhesion particularly, poly(vinyl alcohol) (PVA)-based simulants make an exception. Despite their bioadhesion tendency, unlike mucus, they do not gelate. In this study, we added a physical cross-linking agent to PVA in order to add the gelation aspect and to better represent mucous properties. We show that the resultant mucus simulant develops into two regions: a highly sticky region near the surface of a foreign object (we used hydrophobized silicon to mimic the foreign object) and a fluid region far away from that surface. We show that the sticky part can slide past the less sticky part, while the foreign object is stuck to it. However, this mechanism changes with time. At short gelation times, this tendency to separate into two parts is enhanced and the foreign object remains stuck, while the rest of the gel flows. With time, the force required to allow the sticky part to slide over the fluid part is further reduced. However, if the gelation is allowed to proceed for even longer times without disturbance, the force required to slide the two parts past each other increases and the separation between the two parts is inhibited. The hydrogel becomes a sticky goo, which requires a higher force to move or unclog if placed in a duct (much like what happens with mucus in the tracheal duct). We explain the physics of our findings in terms of a competition between the tendency of the polymer to form a gel network and the tendency of the polymer to adsorb onto the foreign object.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of universal control between non-interacting qubits using the Quantum Zeno effect

The Zeno effect occurs in quantum systems when a very strong measurement is applied, which can alter the dynamics in non-trivial ways. Despite being dissipative, the dynamics stay coherent within any degenerate subspaces of the measurement. Here we show that such a measurement can turn a single-qubit operation into a two- or multi-qubit entangling gate, even in a non-interacting system. We demonstrate this gate between two effectively non-interacting transmon qubits. Our Zeno gate works by imparting a geometric phase on the system, conditioned on it lying within a particular non-local subspace. These results show how universality can be generated not only by coherent interactions as is typically employed in quantum information platforms, but also by Zeno measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Skipper-CCD sensors for the Oscura experiment: requirements and preliminary tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2–10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru.[1 dru (differential rate unit) corresponds to 1 event/kg/day/keV.] In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust reconstruction of single-cell RNA-seq data with iterative gene weight updates

Single-cell RNA-sequencing technologies have greatly enhanced our understanding of heterogeneous cell populations and underlying regulatory processes. However, structural (spatial or temporal) relations between cells are lost during cell dissociation. These relations are crucial for identifying associated biological processes. Many existing tissue-reconstruction algorithms use prior information about subsets of genes that are informative with respect to the structure or process to be reconstructed. When such information is not available, and in the general case when the input genes code for multiple processes, including being susceptible to noise, biological reconstruction is often computationally challenging. We propose an algorithm that iteratively identifies manifold-informative genes using existing reconstruction algorithms for single-cell RNA-seq data as subroutine. We show that our algorithm improves the quality of tissue reconstruction for diverse synthetic and real scRNA-seq data, including data from the mammalian intestinal epithelium and liver lobules.

59 BASIC BIOLOGICAL SCIENCES↗

Selective electron-phonon coupling strength from nonequilibrium optical spectroscopy: The case of MgB 2

The coupling between quasiparticles and bosonic excitations rules the energy transfer pathways in condensed matter systems. The possibility of inferring the strength of specific coupling channels from their characteristic timescales measured in nonequilibrium experiments is still an open question. Here, in this study, we investigate MgB 2 , in which conventional superconductivity at temperatures as high as 39 K is mediated by the strong coupling between the conduction electrons and the 𝐸 2⁢𝑔 phonon mode. By means of broadband time-resolved optical spectroscopy, we show that this selective electron-phonon coupling dictates the nonequilibrium optical response of MgB 2 at early times (<100 fs) after photoexcitation. Furthermore, based on an effective temperature model analysis, we estimate its contribution to the total electron-boson coupling function extracted from complementary equilibrium spectroscopy approaches, namely, optical reflectivity and angle-resolved photoemission spectroscopy. The coupling strength with the 𝐸 2⁢𝑔 phonon modes is thus estimated to be 𝜆 ≃ 0.56, which is approximately half of the total coupling constant, in agreement with 𝑎𝑏 initio calculations from the literature. As a benchmark, broadband time-resolved optical spectroscopy is performed also on the isostructural and nonsuperconducting compound AlB 2 , showing that the nonequilibrium optical response relaxes on a slower timescale due to the lack of strongly coupled phonon modes. Our findings demonstrate the possibility to resolve and quantify selective electron-phonon coupling from nonequilibrium optical spectroscopy.

Mor, Selene [Università Cattolica del Sacro Cuore,↗

Investigation of low-energy particle remnants in high-energy collisions at the LHC with a skipper-CCD detector

We deployed the Mobile Skipper Testing Apparatus ∼33 m away from the Compact Muon Solenoid collision point, the first skipper-CCD detector probing low-energy particles produced in high-energy collisions at the Large Hadron Collider. In this work, we search for beam-related events using data collected in 2024 during beam-on and beam-off periods. The dataset corresponds to integrated luminosities of 113.3 fb −1 and 1.54 nb −1 for the proton-proton and Pb-Pb collision periods, respectively. We report observed event rates in a model-independent framework across two ionization regions: ≤ 20⁢𝑒 − and > 20⁢𝑒 − . For the low-energy region, we perform a likelihood analysis to test the null hypothesis of no beam-correlated signal. We found no significant correlation during proton-proton and Pb-Pb collisions. For the high-energy region, we present the energy spectra for both collision periods and compare event rates for images with and without luminosity. We observe a slight increase in the event rate following the Pb-Pb collisions, coinciding with a rise in the single-electron rate, which will be investigated in future work. Using the low-energy proton-proton results, we place 95% confidence level constraints on the mass-millicharge parameter space of millicharged particles. Overall, the results in this work demonstrate the viability of skipper-CCD technology to explore new physics at high-energy colliders and motivate future searches with more massive detectors.

Cervantes-Vergara, Brenda A. [Fermi National Accel↗

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

Here, we present results from a 3.25 kg–day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ~7 events per kg-day and electron-equivalent energies of ~80 eV, whose origin remains unknown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Daily Modulation of MeV Dark Matter Signals with DAMIC-M

Dark matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth’s bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1 e − events with sidereal period, where a DM signal would appear. We then use these data to place exclusion limits on DM in the mass range [ 0.53 , 2.7 ] MeV / c 2 interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by ∼ 2 orders of magnitude on our previous limit obtained from the total rate of 1 e − events, using the same dataset. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV / c 2 . Published by the American Physical Society 2024

Arnquist, I. (ORCID:0000000256438330)↗

The DAMIC-M experiment: Status and first results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called “hidden sector.” A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parametric model-order-reduction development for unsteady convection

A time-averaged error indicator with POD- h Greedy is developed to drive parametric model order reduction (pMOR) for 2D unsteady natural convection in a high-aspect ratio slot parameterized with the Prandtl number, Rayleigh number, and slot angle with respect to the gravity. The error indicator is extended to accommodate the energy equation and Leray regularization. Despite being two-dimensional and laminar, the target flow regime presents several challenges: 1) there is a bifurcation in the angle parameter space; 2) the solution can be multivalued, even at steady state; and 3) the solution exhibits spatio-temporal chaos at several points in the parameter space. The authors explore several reduced-order models (ROMs) and demonstrate that Leray-regularized Galerkin ROMs provide a robust solution approach for this class of flows. They further demonstrate that error-indicated pMOR can efficiently predict several QOIs, such as mean flow, mean Nusselt number and mean turbulent kinetic energy, even in the presence of a bifurcation. Finally, they show that spatio-temporal chaos can lead to lack of reproducibility in both the full-order model and the reduced-order model and that the variance in the full-order model provides a lower bound on the pMOR error in these cases.

leray regularization↗