Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONOCHROMATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A diffracted-beam monochromator for long linear detectors in X-ray diffractometers with Bragg-Brentano parafocusing geometry

A new diffracted-beam monochromator has been developed for Bragg-Brentano X-ray diffractometers equipped with a linear detector. The monochromator consists of a cone-shaped graphite highly oriented pyrolytic graphite crystal oriented out of the equatorial plane such that the parafocusing geometry is preserved over the whole opening angle of the linear detector. In our standard setup a maximum wavelength discrimination of 3% is achieved with an overall efficiency of 20% and a small decrease in angular resolution of only 0.02 Degree-Sign 2{theta}. In principle, an energy resolution as low as 1.5% can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grating monochromator for electron cyclotron resonance ion source operation

Recently, we started to observe optical line spectra from an ECR plasma using a grating monochromator with a photomultiplier. The light intensity of line spectrum from the ECR plasma had a strong correlation with ion beam intensity measured by a magnetic mass analyzer. This correlation is a significant information for beam tuning because it allows the extraction of the desired ion species from the ECR plasma. Separation of ion species of the same charge to mass ratio with an electromagnetic mass analyzer is known to be an exceptionally complex process, but this research gives new insights into its simplification. In this paper, the grating monochromator method for beam tuning of a Hyper-ECR ion source as an injector for RIKEN azimuthal varying field (AVF) cyclotron is described.

43 PARTICLE ACCELERATORS↗

A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k= 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k= 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selection of CVD Diamond Crystals for X-ray Monochromator Applications Using X-ray Diffraction Imaging

A set of 20 single crystal diamond plates synthesized using chemical vapor deposition (CVD) was studied using X-ray diffraction imaging to determine their applicability as side-bounce (single-reflection) Laue monochromators for synchrotron radiation. The crystal plates were of optical grade (as provided by the supplier) with (001) nominal surface orientation. High dislocation density was found for all samples. Distortions in the crystal lattice were quantified for low-index Laue reflections of interests using rocking curve topography. Maps of effective radius of curvature in the scattering plane were calculated using spline interpolation of the rocking curve peak position across the studied plates. For several selected plates, nearly flat regions with large effective radius of curvature were found (R 0 ≳ 30 - 70 m, some regions as large as 1 × 4 mm 2 ). The average width of the rocking curve for these regions was found to be about 150 μ rad (r.m.s.). These observations suggest that the selected CVD diamond plates could be used as intermediate-bandwidth monochromators refocusing the radiation source to a specific location downstream with close to 1:1 distance ratio.

36 MATERIALS SCIENCE↗

Thermodynamic modeling of solid solutions between monosulfate and monochromate 3CaO Bullet Al{sub 2}O{sub 3} Bullet Ca[(CrO{sub 4}){sub x}(SO{sub 4}){sub 1-x}] Bullet nH{sub 2}O

In hydrated cement paste AFm-phases are regarded to play an important role in the binding of the toxic contaminant chromate through isomorphic substitution with sulfate. Solid solutions formation can lower the solubility of the solids, thus reducing chromate leaching concentrations. Solid solutions between monosulfate and monochromate were synthesized and characterized by X-ray diffraction (XRD), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), energy dispersive x-ray spectroscopy (EDX) and inductive coupled plasma optical emission spectroscopy (ICP-OES). Based on the measured ion concentrations in solution total solubility products of the solid solution series were determined. For pure monochromate a logK = - 28.4 {+-} 0.7 was determined. Results from solid and solution analysis showed that limited solid solutions exist. Based on XRD diffractograms a solid solution with a miscibility gap 0.15 < Crx < 0.85 with a dimensionless Guggenheim parameter of 2.43 was proposed.

36 MATERIALS SCIENCE↗

Comparison of laser-based and monochromator-based thermodynamic temperature measurements

In this work, we describe comparisons between a laser-based and a monochromator-based radiance responsivity calibration of a radiation thermometer. The spectral selection of the radiation thermometer is performed using a spectrally broad photopic-response filter which was selected to minimize effects of convolution differences due to the spectral width of the laser-and the monochromator-based sources. The photopic-response filter is physically thick, which should also reduce possible interference fringes which can be problematic in the laser-based calibrations. We compare the radiance responsivities obtained using the two approaches and also compare the blackbody temperatures determined using the detector/monochromator based and the gold-point based calibration methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rotation of X-ray polarization in the glitches of a silicon crystal monochromator

EXAFS studies on dilute samples are usually carried out by collecting the fluorescence yield using a large-area multi-element detector. This method is susceptible to the `glitches' produced by all single-crystal monochromators. Glitches are sharp dips or spikes in the diffracted intensity at specific crystal orientations. If incorrectly compensated, they degrade the spectroscopic data. Normalization of the fluorescence signal by the incident flux alone is sometimes insufficient to compensate for the glitches. Measurements performed at the state-of-the-art wiggler beamline I20-scanning at Diamond Light Source have shown that the glitches alter the spatial distribution of the sample's quasi-elastic X-ray scattering. Because glitches result from additional Bragg reflections, multiple-beam dynamical diffraction theory is necessary to understand their effects. Here, the glitches of the Si(111) four-bounce monochromator of I20-scanning just above the Ni K edge are associated with their Bragg reflections. A fitting procedure that treats coherent and Compton scattering is developed and applied to a sample of an extremely dilute (100 micromolal) aqueous solution of Ni(NO 3 ) 2 . The depolarization of the wiggler X-ray beam out of the electron orbit is modeled. The fits achieve good agreement with the sample's quasi-elastic scattering with just a few parameters. The X-ray polarization is rotated up to ±4.3° within the glitches, as predicted by dynamical diffraction. These results will help users normalize EXAFS data at glitches.

Sutter, John P.↗

A dual-bandwidth multilayer monochromator system

This paper reports on a planned upgrade to the capabilities of the Illinois Institute of Technology’s BioCAT undulator beamline in an effort to increase the photon flux 10 to 100-fold. This is accomplished by the addition of a double multilayer monochromator (MLM) system complementing the existing cryogenically-cooled double crystal silicon monochromator system. The water-cooled MLMs are designed and fabricated with each having two coated stripes to deliver a 12 keV undulator beam with either 1.0% or 0.5% energy bandwidths (BW). To simplify the mechanical design and operation of the MLM system, the two coatings have been designed with the same period thickness so that the BW selection is accomplished (at the same Bragg angle) by a mere horizontal translation of the MLMs. The challenge has been to find a pair of coatings that provide the desired BWs with high reflectivity at the same incident angle. This was achieved using MoSi2/B4C and Mo/MoSi2/B4C/MoS2 multilayers at an angle of 1.194°. The bandwidths and reflectivities attained are 0.52 and 83.33% for the former and 0.86 and 75.9% for the latter. Details are provided.

X-ray optics, multilayer, coating, tuning, reflect↗

Helium window for shock-tube monochromators

Technique for coupling vacuum ultraviolet monochromator to shock tube to avoid loss of high energy ultraviolet light during quantitative measurements is described. System consists of helium gas window pumping through small aperture in entrance pupil of monochromator. Diagram of equipment and principles of operation are presented.

Thomas, G. M.↗

Tunable VUV photofragment monochromator

A versatile tunable VUV photofragment monochromator is described. The instrument uses a unique flashlamp and a single slit monochromator to produce the photofragments. A tunable dye laser is used to detect these fragments via laser induced fluorescence. The results of preliminary design parameter measurements are presented along with the first photofragment spectra obtained with this instrument. It is shown that the SNR is adequate to assign single quantum state photofragment distributions.

Miller, G. E.↗

Portable high-resolution laser monochromator-interferometer with multichannel electronic readout

A high-resolution 0.4-m monochromator is described for use in wavelength diagnosis of tunable pulsed and CW laser sources in the 3000-10,000-A region. The f/20 design uses an echelle grating in an over-and-under Ebert configuration with a scanned photodiode array to provide a real-time multichannel display of spectral output. Absolute wavelength may be determined to 0.1 A with the monochromator, and a Fabry-Perot interferometer attachment extends linewidth measurement capability to 0.01 A or better. Spectra are displayed on a storage oscilloscope, and calculation of laser parameters is explained. The instrument measures 70 cm long x 15 cm wide x 20 cm high.

Morris, M. B.↗

Scanning X-Ray Or Extreme-Ultraviolet Monochromator

Wavelength of peak transmission of proposed high-throughput, narrow-band-pass x-ray or extreme-ultraviolet monochromator continuously adjustable. Essential filtering and reflecting components designed according to principles described in "Compact X-Ray and Extreme-Ultraviolet Monochromator" (MFS-28499). However, angle of incidence varied to change wavelength of Bragg reflection.

Hoover, Richard↗

Tunable side-bounce x-ray monochromator

Monochromators selectively transmit a narrow band of wavelengths of radiation from a broader band of wavelengths for use in a variety of applications and industries. Disclosed is a method and system for fixed-exit angle tunable monochromator. The system includes a first diffraction element configured to reflect an input beam incident on a surface of the first diffraction element. The input beam has an input beam vector and the first diffraction element is rotatable about the input beam vector. The system further includes a second diffraction element configured to reflect the beam as an output beam having a fixed beam exit angle. The beam is incident on a surface of the second diffraction element and the reflected beam has a reflected beam vector. The second diffraction element is rotatable about both the input beam vector and the reflected beam vector.

Hong, Hawoong↗

A simple method for mitigating error in the fixed-offset of a double-crystal monochromator

In order to maintain a constant monochromatic synchrotron X-ray beam height for all energies, the separation between the crystals of a double-crystal monochromator is typically adjusted, via translation of the second crystal, while X-ray energy is varied, via rotation of the crystal pair. The ability to accurately translate the second crystal requires precise knowledge of the separation between the two crystals and, when present, crystal miscuts. Here, a simple method for calibrating the crystal gap from measured variation in the X-ray beam height that eliminates error in the fixed beam offset is provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reducing heat load density with asymmetric and inclined double-crystal monochromators: principles and requirements revisited

Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains. Based on Fourier coupled-wave diffraction theory calculations, it is rigorously proved that the iDCM has almost the same properties as the conventional symmetric DCM, including the efficiency, angular acceptance, bandwidth, tuning energy range and sensitivity to misalignment. The exception is that, for the extremely inclined geometry that can achieve very large footprint expansion, the iDCM has (beneficially) a larger bandwidth and wider angular acceptance. Inclined diffraction has the `rho-kick effect' that can be cancelled by the second reflection of the iDCM (even with misalignment), except that inhomogeneous strains may cause non-uniform rho-kick angles. At present, fabrication/mounting-induced strains pose low risk since they can be controlled to <0.5 µrad over large areas. The only uncertain challenge is the thermally induced strains, yet it is estimated that these strains are naturally lowered by the large footprint and may be further mitigated by optimized cryogenic cooling to the 1–2 µrad level. Overall, aDCMs and iDCMs have more stringent requirements than normal DCMs, but they are feasible schemes in practice.

asymmetric monochromator↗

Twist-Angle-Dependent Excitons in Moiré MoTe 2 Visualized by Cryogenic STEM and Monochromated EELS

van der Waals twisted bilayers of transition-metal dichalcogenides exhibit diverse excitonic phenomena arising from moiré superlattices and lattice reconstruction. While interlayer strain and relaxation reshape their electronic bands, their nanoscale influence on the excitonic fine structure remains poorly understood. Here, we study the interplay between spin–orbit coupling (SOC) and the moiré lattice by probing excitons in H-type twisted (∼8-layer × 8-layer) MoTe 2 using atomic-resolution scanning transmission electron microscopy (STEM) combined with monochromated electron energy loss spectroscopy (EELS) at cryogenic temperature. Spatially resolved spectra reveal moiré-site-dependent variations in excitonic absorption, including modulation of the X B exciton across the moiré unit cell. We find that SOC in MoTe 2 increases with the twist angle within the studied range (2–4.5°), with the largest value observed at 4°. Furthermore, these findings establish the twist angle as a tunable parameter for SOC via moiré engineering and link local structural relaxation to excitonic fine structure in twisted MoTe 2 .

cryogenic STEM/EELS↗

The extreme ultraviolet split and femtosecond delay unit at the plane grating monochromator beamline PG2 at FLASH

An extreme ultraviolet split and femtosecond delay unit based on grazing incidence Mach-Zehnder geometry has been designed and implemented on the plane grating monochromator beamline PG2 at FLASH, the Free Electron Laser at DESY. This device splits the FLASH radiation into two beams, which can independently be steered, filtered and temporally delayed between -5.1 and +5.1 ps with uncertainty in the temporal accuracy of 210 as. To demonstrate the performance of this device, we have performed longitudinal coherence studies of FLASH radiation as well as measured the pulse length by nonlinear two-photon double-ionization in helium.

43 PARTICLE ACCELERATORS↗

Commissioning of a Soft X-ray Beamline PF-BL-16A with a Variable-Included-Angle Varied-Line-Spacing Grating Monochromator

The design and commissioning of a new soft X-ray beamline, BL-16A, at the Photon Factory is presented. The beamline consists of a pre-focusing mirror, an entrance slit, a variable-included-angle varied-line-spacing plane grating monochromator, and a post-focusing system as usual, and provides circularly and linearly polarized soft X rays in the energy range 200-1500 eV with an APPLE-II type undulator. The commissioning procedure for the beamline optics is described in detail, especially the check of the focal position for the zero-th order and diffracted X rays.

43 PARTICLE ACCELERATORS↗