Broadband anti-reflective coatings for cosmic microwave background experiments

The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth compared to waveguide-coupled detectors. However, the increase in bandwidth comes at a cost: the lenses (up to ~700 mm diameter) and lenslets (~5 mm diameter, hemispherical lenses on the focal plane) used in these systems are made from high-refractive-index materials (such as silicon or amorphous aluminum oxide) that reflect nearly a third of the incident radiation. In order to maximize the faint CMB signal that reaches the detectors, the lenses and lenslets must be coated with an anti-reflective (AR) material. The AR coating must maximize radiation transmission in scientifically interesting bands and be cryogenically stable. Such a coating was developed for the third generation camera, SPT-3G, of the South Pole Telescope (SPT) experiment, but the materials and techniques used in the development are general to AR coatings for mm-wave optics. The three-layer polytetra uoroethylene-based AR coating is broadband, inexpensive, and can be manufactured with simple tools. The coating is field tested; AR coated focal plane elements were deployed in the 2016-2017 austral summer and AR coated reimaging optics were deployed in 2017-2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cavity electro-optics in thin-film lithium niobate for efficient microwave-to-optical transduction

Linking superconducting quantum devices to optical fibers via microwave-optical quantum transducers may enable large-scale quantum networks. For this application, transducers based on the Pockels electro-optic (EO) effect are promising for their direct conversion mechanism, high bandwidth, and potential for low-noise operation. However, previously demonstrated EO transducers require large optical pump power to overcome weak EO coupling and reach high efficiency. Here, we create an EO transducer in thin-film lithium niobate, a platform that provides low optical loss and strong EO coupling. We demonstrate on-chip transduction efficiencies of up to and of optical pump power. The transduction efficiency can be improved by further reducing the microwave resonator’s piezoelectric coupling to acoustic modes, increasing the optical resonator quality factor to previously demonstrated levels, and changing the electrode geometry for enhanced EO coupling. We expect that with further development, EO transducers in thin-film lithium niobate can achieve near-unity efficiency with low optical pump power.

Holzgrafe, Jeffrey (ORCID:0000000160121451)↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Measurement of the Cosmic Microwave Background B-mode Polarization Power Spectrum at Subdegree Scales from Two Years of polarbear Data

We report an improved measurement of the cosmic microwave background B-mode polarization power spectrum with the Polarbear experiment at 150 GHz. By adding new data collected during the second season of observations (2013–2014) to re-analyzed data from the first season (2012–2013), we have reduced twofold the band-power uncertainties. The band powers are reported over angular multipoles 500⩽ℓ⩽2100, where the dominant B-mode signal is expected to be due to the gravitational lensing of E-modes. We reject the null hypothesis of no B-mode polarization at a confidence of 3.1σ including both statistical and systematic uncertainties. We test the consistency of the measured B-modes with the Λ Cold Dark Matter (ΛCDM) framework by fitting for a single lensing amplitude parameter A {sub L} relative to the Planck 2015 best-fit model prediction. We obtain A{sub L}=0.60{sub −0.24}{sup +0.26}(stat){sub −0.04}{sup +0.00}(inst) ± 0.14(foreground) ± 0.04(multi), where A{sub L}=1 is the fiducial ΛCDM value.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of the Cross-spectra of the Cosmic Infrared and Microwave Backgrounds from 95 to 1200 GHz

We present measurements of the power spectra of cosmic infrared background (CIB) and cosmic microwave background (CMB) fluctuations in six frequency bands. Maps at the lower three frequency bands, 95, 150, and 220 GHz (3330, 2000, and 1360 μm) are from the South Pole Telescope, while the upper three frequency bands, 600, 857, and 1200 GHz (500, 350, 250 μm) are observed with Herschel/SPIRE. From these data, we produce 21 angular power spectra (6 auto- and 15 cross-frequency) spanning the multipole range 600 ≤ ℓ ≤ 11,000. Our measurements are the first to cross-correlate measurements near the peak of the CIB spectrum with maps at 95 GHz, complementing and extending the measurements from Planck Collaboration et al. at 143–857 GHz. The observed fluctuations originate largely from clustered, infrared-emitting, dusty star-forming galaxies, the CMB, and to a lesser extent radio galaxies, active galactic nuclei, and the Sunyaev–Zel’dovich effect.

cosmic background radiation↗

Microwave radiation hazards around large microwave antenna.

The microwave radiation hazards associated with the use of large antennas become increasingly more dangerous to personnel as the transmitters go to ever higher powers. The near-field area is of the greatest concern. It has spill over from subreflector and reflections from nearby objects. Centimeter waves meeting in phase will reinforce each other and create hot spots of microwave energy. This has been measured in front of and around several 26-meter antennas. Hot spots have been found and are going to be the determining factor in delineating safe areas for personnel to work. Better techniques and instruments to measure these fields are needed for the evaluation of hazard areas.

Klascius, A.↗

Microwave integrated circuit radiometer front-ends for the Push Broom Microwave Radiometer

Microwave integrated circuit front-ends for the L-band, S-band and C-band stepped frequency null-balanced noise-injection Dicke-switched radiometer to be installed in the NASA Langley airborne prototype Push Broom Microwave Radiometer (PBMR) are described. These front-ends were developed for the fixed frequency of 1.413 GHz and the variable frequencies of 1.8-2.8 GHz and 3.8-5.8 GHz. Measurements of the noise temperature of these units were made at 55.8 C, and the results of these tests are given. While the overall performance was reasonable, improvements need to be made in circuit losses and noise temperatures, which in the case of the C-band were from 1000 to 1850 K instead of the 500 K specified. Further development of the prototypes is underway to improve performance and extend the frequency range.

Harrington, R. F.↗

Sea ice effective microwave emissivities from satellite passive microwave and infrared observations

Near-simultaneous images from the temperature-humidity IR radiometer and dual-polarization scanning multichannel microwave radiometer of the Nimbus 7 satellite are used to investigate microwave sea ice emissivities on a global scale. Emissivities in several Arctic region study areas are found to be approximately constant during a nine-month pereiod covering the fall, winter and spring months, in the cases of both first-year and multiyear ice. During the onset of summer, emissivity increases of about 30 percent are observed at 37 GHz in multiyear ice. A multichannel cluster analysis over very large study areas during winter indicates considerable variability in emissivities of consolidated ice clusters at 37 GHz, and only 1/3 as much variability at 18 GHz. If the variability within each cluster is quantified and taken into account by means of multispectral analysis, data on ice thickness and surface characteristics may also be obtained.

Comiso, J. C.↗

Utilization of active microwave roughness measurements to improve passive microwave soil moisture estimates over bare soils

Multisensor aircraft data were used to establish the potential of the active microwave sensor response to be used to compensate for roughness in the passive microwave sensor's response to soil moisture. Only bare fields were used. It is found that the L-band radiometer's capability to estimate soil moisture significantly improves when surface roughness is accounted for with the scatterometers.

Theis, S. W.↗

Utilization of active microwave roughness measurements to improve passive microwave soil moisture estimates over bare soils

Multisensor aircraft data were used to establish the potential of the active microwave sensor response to be used to compensate for roughness in the passive microwave sensor's response to soil moisture. Only bare fields were used. It is found that the L-band radiometer's capability to estimate soil moisture significantly improves when surface roughness is accounted for with the scatterometers.

Theis, S. W.↗

Preliminary separation of galactic and cosmic microwave emission for the COBE Differential Microwave Radiometer

Preliminary models of microwave emission from the Milky Way Galaxy based on COBE and other data are constructed for the purpose of distinguishing cosmic and Galactic signals. Differential Microwave Radiometer (DMR) maps, with the modeled Galactic emission removed, are fitted for a quadrupole distribution. Autocorrelation functions for individual Galactic components are presented. When Galactic emission is removed from the DMR data, the residual fluctuations are virtually unaffected, and therefore they are not dominated by any known Galactic emission component.

Bennet, C. L.↗

Microwave AeroGel Volatile Collector (MAGVC) Aerogel and Microwave Radiation Study

The MAGVC is a volatile extraction system that uses microwave radiation to sublimate and collect water trapped in regolith on the lunar surface It is comprised of: - Microwave source (magnetron) - Aerogel-insulated chamber (depicted as a dome) - Volatile storage system (depicted as 4 tanks) - Autonomous operating system

Aerogel↗

Design and characterization of an electromagnetic-resonant cavity microwave plasma reactor for atmospheric pressure carbon dioxide decomposition

Plasma processes are ideally suited for the conversion of renewable electricity into gas-phase reactivity, such as for the decomposition of carbon dioxide (CO 2 ). The design, development, and characterization of a microwave plasma reactor for atmospheric pressure undiluted carbon dioxide decomposition are presented. The reactor operates as an electromagnetic-resonant cavity in which the generated plasma forms a bulb attached to a converging-diverging nozzle and stabilized by streams of tangentially-injected processing gas. Electromagnetic wave confinement, residence time, and critical gas vorticity constitute fundamental reactor sizing and operation parameters. Experimental findings demonstrate that flow rate plays a dual role in plasma stabilization and process performance, whereas deposited power has a minor role in CO 2 decomposition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Demodulation by Frequency Chirping in Coherence Microwave Photonic Interferometry

This paper presents a signal processing method to demodulate the optical interference phase of cascaded individual optical fiber intrinsic Fabry-Perot interferometric (IFPI) sensors in a coherent microwave-photonic interferometry (CMPI) distributed sensing system. The new method utilizes the chirp effect of electro-optic modulator (EOM) to create a quasi-quadrature optical interference phase shift between two adjacent pulses which correspond to two adjacent reflection points in the time domain. The phase shift can be controlled by adjusting the bias voltage that is applied to the EOM. The interference phase is calculated by elliptically fitting the phase shift. The interference phase change is proportional to the optical path difference (OPD) change of the interferometer, and the sign can be used to differentiate the increase or decrease of the OPD. The method is demonstrated for distributed strain sensing, showing good linearity, high resolution and large dynamic range.

42 ENGINEERING↗

Optimization of Transition Edge Sensor Arrays for Cosmic Microwave Background Observations With the South Pole Telescope

In this paper, we describe the optimization of transition-edge-sensor (TES) detector arrays for the third-generation camera for the South PoleTelescope. The camera, which contains similar to 16 000 detectors, will make high-angular-resolution maps of the temperature and polarization of the cosmic microwave background. Our key results are scatter in the transition temperature of Ti/Au TESs is reduced by fabricating the TESs on a thin Ti(5 nm)/Au(5 nm) buffer layer and the thermal conductivity of the legs that support our detector islands is dominated by the SiOx dielectric in the microstrip transmission lines that run along the legs.

Ding, Junjia↗