At least 73 records · Page 4

Low threshold lasing of bubble-containing glass microspheres by non-whispering gallery mode excitation over a wide wavelength range

Bubble-containing Nd{sup 3+}-doped tellurite glass microspheres were fabricated by localized laser heating technique to investigate their optical properties for use as microresonators. Fluorescence and excitation spectra measurements were performed by pumping with a tunable CW-Ti:Sapphire laser. The excitation spectra manifested several sharp peaks due to the conventional whispering gallery mode (WGM) when the pumping laser was irradiated to the edge part of the microsphere. However, when the excitation light was irradiated on the bubble position inside the microsphere, “non-WGM excitation” was induced, giving rise to numerous peaks at a broad wavelength range in the excitation spectra. Thus, efficient excitation was achieved over a wide wavelength range. Lasing threshold excited at the bubble position was much lower than that for the excitation at the edges of the microsphere. The lowest value of the laser threshold was 34 μW for a 4 μm sphere containing a 0.5 μm bubble. Efficiency of the excitation at the bubble position with broadband light was calculated to be 5 times higher than that for the edge of the microsphere. The bubble-containing microsphere enables efficient utilization of broadband light excitation from light-emitting diodes and solar light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dose-rate distribution of {sup 32}P-glass microspheres for intra-arterial brachytherapy

Purpose: The intra-arterial administration of radioactive glass microspheres is an alternative therapy option for treating primary hepatocellular carcinoma, the main cause of liver cancer death, and metastatic liver cancer, another important kind of cancer induced in the liver. The technique involves the administration of radioactive microspheres in the hepatic artery, which are trapped preferentially in the tumor. Methods: In this work the GEANT4 toolkit was used to calculate the radial dose-rate distributions in water from {sup 32}P-loaded glass microspheres and also from {sup 90}Y-loaded glass microspheres. To validate the toolkit for this application, the authors compared the dose-rate distribution of {sup 32}P and {sup 90}Y point sources in water with data from the International Commission on Radiation Units and Measurements report 72. Results: Tables of radial dose-rate distributions are provided for practical use in brachytherapy planning with these microspheres. Conclusions: The simulations with the microspheres show that the shape of the beta ray energy spectra with respect to the {sup 32}P and {sup 90}Y sources is significantly modified by the glass matrix.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determining the effects of microsphere and surrounding material composition on {sup 90}Y dose kernels using egsnrc and mcnp5

Purpose: Recent advances in the imaging of {sup 90}Y using positron emission tomography (PET) and improved uncertainty in the branching ratio for the internal pair production component of {sup 90}Y decay allow for a more accurate determination of the activity distribution of {sup 90}Y microspheres within a patient. This improved activity distribution can be convolved with the dose kernel of {sup 90}Y to calculate the dose distribution within a patient. This work investigates the effects of microsphere and surrounding material composition on {sup 90}Y dose kernels using egsnrc and mcnp5 and compares the results of these two transport codes. Methods: Monte Carlo simulations were performed with egsnrc and mcnp5 to calculate the dose rate at multiple radial distances around various {sup 90}Y sources. Point source simulations were completed with mcnp5 to determine the optimal electron transport settings for this work. After determining the optimal settings, point source simulations were completed using egsnrc (user code edknrc) and mcnp5 in water and liver [as defined by the International Commission on Radiation Units and Measurements (ICRU) Report 44]. The results were compared to ICRU Report 72 reference data. Point source simulations were also completed in water with a density of 1.06 g{center_dot}cm{sup -3} to evaluate the effect of the density of the surrounding material. Glass and resin microsphere simulations were performed with average and maximum diameter and density values (based on values given in the literature) in water and in liver. The results were compared to point source simulation results using the same transport code and in the same surrounding material. All simulations had statistical uncertainties less than 1%. Results: The optimal transport settings in mcnp5 for this work included using the energy-and step-specific algorithm (DBCN 17J 2) and ESTEP set to 10. These settings were used for all subsequent simulations with mcnp5. The point source simulations in water for both egsnrc and mcnp5 were found to agree within 2% of the ICRU 72 reference data over the investigated range. Point source simulations in liver had large differences relative to ICRU 72, approaching -60% near the maximum range of {sup 90}Y. These differences are mostly attributed to the difference in density between water (1.0 g{center_dot}cm{sup -3}) and liver (1.06 g{center_dot}cm{sup -3}). Glass and resin microsphere simulations showed a slight decrease in the dose rate near the maximum range of {sup 90}Y relative to the point source simulations. The largest relative differences were approximately -4.2% and -2.8% for the glass and resin microspheres, respectively. Agreement between the egsnrc and mcnp5 simulations results was generally good. Conclusions: The presence of the microsphere material causes slight differences in the {sup 90}Y dose kernel compared to those calculated with point sources. Large differences were seen between simulations in water and those in liver. For the most accurate calculation of the dose distribution, the density of the patient's liver should be accounted for in the calculation of the dose kernel. Lastly, due to the need to determine the optimal transport settings with mcnp5, electron transport with this code should be used with caution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of Gelatin-Coated Hydrogel Microspheres for Novel Bioink Design: A Crosslinker Study

The development of vascularized tissue is a substantial challenge within the field of tissue engineering and regenerative medicine. Studies have shown that positively-charged microspheres exhibit dual-functions: (1) facilitation of vascularization and (2) controlled release of bioactive compounds. In this study, gelatin-coated microspheres were produced and processed with either EDC or transglutaminase, two crosslinkers. The results indicated that the processing stages did not significantly impact the size of the microspheres. EDC and transglutaminase had different effects on surface morphology and microsphere stability in a simulated colonic environment. Incorporation of EGM and TGM into bioink did not negatively impact bioprintability (as indicated by density and kinematic viscosity), and the microspheres had a uniform distribution within the scaffold. These microspheres show great potential for tissue engineering applications.

60 APPLIED LIFE SCIENCES↗

ZnO-based hollow microspheres with mesoporous shells: Polyoxometalate-assisted fabrication, growth mechanism and photocatalytic properties

With the assistance of Keggin-type polyoxometalate, ZnO hollow microspheres with mesoporous shells were synthesized via a simple solvothermal approach without any templates and surfactants. The observations of morphology and structure performed by field emission scanning electronic microscopy and transmission electron microscopy indicated that the shells of the ZnO hollow spheres were built from nanosheets which were composed of nanoparticles. The transformation of structure and composition of samples were investigated by X-ray diffraction, X-ray photoelectron spectrometry and fourier transform infrared absorption spectroscopy. The formation mechanism of the hollow spheres is proposed based on time-dependent experimental results. The ZnO hollow microspheres exhibited a high photocatalytic activity for decolorization of Rhodamine B under ultraviolet irradiation. - Graphical Abstract: ZnO hollow spheres with mesporous shells were synthesized by an one-pot polyoxometalate-assisted solvothermal route. The ZnO hollow microspheres exhibited a high photocatalytic activity for decolorization of Rhodamine B (RhB) under UV irradiation. Highlights: > ZnO hollow microspheres were synthesized via a solvothermal route with polyoxometalate. > The polyoxometalate was vital for the formation of the hollow microspheres. > The ZnO hollow microspheres exhibited excellent photocatalytic activity of Rhodamine B.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical 3D morphology characterization of vaterite microspheres produced by engineered Escherichia coli

Hollow vaterite microspheres are important materials for biomedical applications such as drug delivery and regenerative medicine owing to their biocompatibility, high specific surface area, and ability to encapsulate a large number of bioactive molecules and compounds. We demonstrated that hollow vaterite microspheres are produced by an Escherichia coli strain engineered with a urease gene cluster from the ureolytic bacteria Sporosarcina pasteurii in the presence of bovine serum albumin. We characterized the 3D nanoscale morphology of five biogenic hollow vaterite microspheres using 3D high-angle annular dark field scanning transmission electron microscopy (HAADF-STEM) tomography. Using automated high-throughput HAADF-STEM imaging across several sample tilt orientations, we show that the microspheres evolved from a smaller more ellipsoidal shape to a larger more spherical shape while the internal hollow core increased in size and remained relatively spherical, indicating that the microspheres produced by this engineered strain likely do not contain the bacteria. The statistical 3D morphology information demonstrates the potential for using biogenic calcium carbonate mineralization to produce hollow vaterite microspheres with controlled morphologies.

3D morphology↗

Synthesis and characterization of flower-like CuIn{sub 1-x}Ga{sub x}S{sub 2} (x = 0.3) microspheres

Graphical abstract: In this paper, flower-like CuIn{sub 1-x}Ga{sub x}S{sub 2} (x = 0.3) microspheres were prepared via biomolecule-assisted solvothermal rate with CuCl{sub 2}{center_dot}2H{sub 2}O, GaCl{sub 3}, InCl{sub 3} and L-cystine as raw materials. UV-vis absorption spectrum showed that the band gap of CuIn{sub 0.7}Ga{sub 0.3}S{sub 2} microspheres was about 2.427 eV. Highlights: Black-Right-Pointing-Pointer We reported a small biomolecule-assisted route to synthesis CuIn{sub 0.3}Ga{sub 0.7}S{sub 2}. Black-Right-Pointing-Pointer The possible mechanisms of flower-like CuIn{sub 0.3}Ga{sub 0.7}S{sub 2} microspheres were proposed. Black-Right-Pointing-Pointer The as-prepared CuIn{sub 0.3}Ga{sub 0.7}S{sub 2} products were investigated by XRD, XPS, FESEM and TEM. Black-Right-Pointing-Pointer The optical properties were investigated by UV-vis spectroscopy and Raman spectrum. -- Abstract: We report the formation and characterization of the flower-like CuIn{sub 1-x}Ga{sub x}S{sub 2} (x = 0.3) microspheres using CuCl{sub 2}{center_dot}2H{sub 2}O, GaCl{sub 3}, InCl{sub 3} and L-cystine in the mixed solvent of ethylene glycol and distilled water (1:2, v/v) at 200 Degree-Sign C for 24 h. XRD results indicated that the CuIn{sub 0.7}Ga{sub 0.3}S{sub 2} nanostructures have a (1 1 2) preferred orientation. The EDS and XPS analyses of the sample revealed that Cu, In, Ga and S were present in an atomic ratio of approximately 1:0.7:0.3:2. FESEM and TEM images showed that the product was microspheres, consisting of nanoplates with the thickness of about 20 nm. The optical properties were investigated by ultraviolet-visible (UV-vis) absorption spectroscopy and Raman spectroscopy. UV-vis absorption spectrum indicated that the band gap of as-synthesized flower-like CuIn{sub 0.7}Ga{sub 0.3}S{sub 2} microspheres was about 2.427 eV. Raman spectrum of the obtained CuIn{sub 0.7}Ga{sub 0.3}S{sub 2} exhibited a high-intensity peak at 302 cm{sup -1} could be assigned as A1-mode.

36 MATERIALS SCIENCE↗

The simple preparation of birnessite-type manganese oxide with flower-like microsphere morphology and its remarkable capacity retention

Graphical abstract: Flower-like birnessite-type manganese oxide microspheres with large specific surface area and excellent electrochemical properties have been prepared by a facile hydrothermal method. Highlights: ► Birnessite-type manganese oxide with flower-like microsphere morphology and large specific surface area. ► A facile low-temperature hydrothermal method. ► Novel flower-like microsphere consists of the thin nano-platelets. ► Birnessite-type manganese oxide exhibits an ideal capacitive behavior and excellent cycling stability. -- Abstract: Birnessite-type manganese oxide with flower-like microsphere morphology and large specific surface area has been prepared by hydrothermal treating a mixture solution of KMnO{sub 4} and (NH{sub 4}){sub 2}SO{sub 4} at 90 °C for 24 h. The obtained material is characterized by X-ray diffraction, scanning electron microscopy, transmission electron microscopy and N{sub 2} adsorption–desorption. Results indicate that the birnessite-type manganese oxide shows novel flower-like microsphere morphology and a specific surface area of 280 m{sup 2} g{sup −1}, and the flower-like microsphere consists of the thin nano-platelets. Electrochemical characterization indicates that the prepared material exhibits an ideal capacitive behavior with a capacitance value of 278 F g{sup −1} in 1 mol L{sup −1} Na{sub 2}SO{sub 4} aqueous solution at a scan rate of 5 mV s{sup −1}. Moreover, the prepared manganese oxide electrode shows excellent cycle stability, and the specific capacitance can maintain 98.6% of the initial one after 5000 cycles.

36 MATERIALS SCIENCE↗

Hydrothermal synthesis and magnetic properties of CuO hollow microspheres

Graphical abstract: - Highlights: • CuO hollow microspheres were synthesized through hydrothermal route. • The possible growth mechanism was proposed according to the experimental results. • CuO hollow microspheres show an anomalous ferromagnetic behavior at 5 K and 300 K. - Abstract: In the present work, CuO hollow microspheres with the diameter about 2 μm were successfully synthesized through a facile hydrothermal method. The phase purity, morphologies and structure features of the as obtained products were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and Raman spectroscopy, respectively. It was found that reaction temperature, reaction time and different volume ratios of ethanol and distilled water played important roles on the morphologies of the obtained CuO hollow microspheres. The possible formation mechanism was also proposed according to the corresponding experimental results. The magnetic properties were investigated by superconducting quantum interference device, revealing that the CuO hollow microspheres exhibited an anomalous ferromagnetic behavior at 5 K and 300 K. At the same time, the origin of the ferromagnetism in CuO hollow microspheres was also discussed.

36 MATERIALS SCIENCE↗

Pitch carbon microsphere composite

Petroleum pitch carbon microspheres were prepared by flash heating emulsified pitch and carbonizing the resulting microspheres in an inert atmosphere. Microsphere composites were obtained from a mixture of microspheres and tetraester precursor pyrrone powder. Scanning electron micrographs of the composite showed that it was an aggregate of microspheres bonded together by the pyrrone at the sphere contact points, with voids in and among the microspheres. Physical, thermal, and sorption properties of the composite are described. Composite applications could include use as a honeycomb filler in elevated-temperature load-bearing sandwich boards or in patient-treatment tables for radiation treatment of tumors.

Price, H. L.↗

Monodisperse, polymeric microspheres produced by irradiation of slowly thawing frozen drops

Monodisperse, polymeric microspheres are formed by injecting uniformly shaped droplets of radiation polymerizable monomers, preferably a biocompatible monomer, having covalent binding sites such as hydroxyethylmethacrylate, into a zone, impressing a like charge on the droplet so that they mutually repel each other, spheroidizing the droplets within the zone and collecting the droplets in a pool of cryogenic liquid. As the droplets enter the liquid, they freeze into solid, glassy microspheres, which vaporizes a portion of the cryogenic liquid to form a layer. The like-charged microspheres, suspended within the layer, move to the edge of the vessel holding the pool, are discharged, fall and are collected. The collected microspheres are irradiated while frozen in the cryogenic liquid to form latent free radicals. The frozen microspheres are then slowly thawed to activate the free radicals which polymerize the monomer to form evenly-sized, evenly-shaped, monodisperse polymeric microspheres.

Rhim, Won-Kyu↗

Method of detecting luminescent target ions with modified magnetic microspheres

This invention provides methods of using modified magnetic microspheres to extract target ions from a sample in order to detect their presence in a microfluidic environment. In one or more embodiments, the microspheres are modified with molecules on the surface that allow the target ions in the sample to form complexes with specific ligand molecules on the microsphere surface. In one or more embodiments, the microspheres are modified with molecules that sequester the target ions from the sample, but specific ligand molecules in solution subsequently re-extract the target ions from the microspheres into the solution, where the complexes form independent of the microsphere surface. Once the complexes form, they are exposed to an excitation wavelength light source suitable for exciting the target ion to emit a luminescent signal pattern. Detection of the luminescent signal pattern allows for determination of the presence of the target ions in the sample.

47 OTHER INSTRUMENTATION↗

Mesoporous metal oxide microsphere electrode compositions and their methods of making

Compositions and methods of making are provided for treated mesoporous metal oxide microspheres electrodes. The compositions comprise (a) microspheres with an average diameter between 200 nanometers (nm) and 10 micrometers (.mu.m); (b) mesopores on the surface and interior of the microspheres, wherein the mesopores have an average diameter between 1 nm and 50 nm and the microspheres have a surface area between 50 m.sup.2/g and 500 m.sup.2/g, and wherein the composition has an electrical conductivity of at least 1.times.10.sup.-7 S/cm at 25.degree. C. and 60 MPa. The methods of making comprise forming a mesoporous metal oxide microsphere composition and treating the mesoporous metal oxide microspheres by at least one method selected from the group consisting of: (i) annealing in a reducing atmosphere, (ii) doping with an aliovalent element, and (iii) coating with a coating composition.

25 ENERGY STORAGE↗

Mesoporous metal oxide microsphere electrode compositions and their methods of making

Compositions and methods of making are provided for mesoporous metal oxide microspheres electrodes. The mesoporous metal oxide microsphere compositions comprise (a) microspheres with an average diameter between 200 nanometers (nm) and 10 micrometers (.mu.m); (b) mesopores on the surface and interior of the microspheres, wherein the mesopores have an average diameter between 1 nm and 50 nm and the microspheres have a surface area between 50 m.sup.2/g and 500 m.sup.2/g. The methods of making comprise forming composite powders. The methods may also comprise refluxing the composite powders in a basic solution to form an etched powder, washing the etched powder with an acid to form a hydrated metal oxide, and heat-treating the hydrated metal oxide to form mesoporous metal oxide microspheres.

36 MATERIALS SCIENCE↗

Synthesis and Characterization of Polymeric Pore Former Microspheres using Modified Polymer Resin

Porosity in polymer parts is often desired to improve mechanical properties. Individual pores must be small enough that bulk mechanical properties are retained but significant enough to reduce the density of the material. Filler materials can be incorporated into polymer matrices and subsequently removed to create voids. The materials used to create the voids are known as pore-formers. The present research aims to create spherical pores in a silicone matrix by inserting and removing core materials or fillers post-cure. A method was developed to incorporate pore formers into an uncured polymer resin and remove the materials from the matrix. Polyethylene Glycol (PEG) and Polylactic Acid (PLA) microspheres are created and incorporated into silicone matrices as pore formers. Microspheres with controllable size distributions are formed via ultrasonic spray pyrolysis and emulsion formation. Microspheres are removed from the matrix by solvent extraction and calcination. PLA microspheres were modified by hydroxyl addition to the surface to study their solubility in water. PEG-PLA block copolymers are also synthesized and investigated, comparing their physical and chemical properties to the monomers to identify whether the block copolymer microspheres will be more easily removable than their monomeric microspheres. Moreover, other properties including thermal stability, rheology, and mechanical response are studied. The present dissertation provides a comprehensive understanding of the synthesis and characterization of PEG and PLA-based pore formers, toward the future development of feedstock for additive manufacturing porous structures.

Damptey, Ransford↗

Lines of Bound States in the Continuum in Monodisperse Microsphere Structures

Incorporating epitaxially grown active semiconductor media into self-assembled microsphere crystals has remained a major challenge as the curved geometry of the spheres is incompatible with conventional planar growth and patterning techniques. As a result, active photonic devices based on such self-assembled structures, which have other desirable properties such as enabling the rapid assembly of large area systems, have been elusive. Here, we numerically demonstrate an alternative route to creating high-Q resonances in microsphere-based nanophotonic assemblies compatible with standard optical gain materials. We show that close-packed layers of monodisperse microspheres can exhibit symmetry bandgaps, regardless of their layer stacking order. Thus, this microsphere environment can be used to create lines of bound states in the continuum (BICs) of an embedded slab made of active material. Using a realistic ZnS@SiO 2 (core-shell) architecture and sphere diameters compatible with scalable colloidal assembly, we predict sharp spectral features in angle-resolved transmission that trace these lines of BICs and persist in the presence of some fabrication disorder. Altogether, in enabling the integration of unpatterned epitaxial gain slabs with large-area colloidal microsphere assemblies, this approach opens a practical path toward active, dynamically reconfigurable photonic devices that leverage BIC physics for narrow-linewidth lasing and enhanced light–matter interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Switching the Loaded Agent from Epirubicin to Cisplatin: Salvage Transcatheter Arterial Chemoembolization with Drug-eluting Microspheres for Unresectable Hepatocellular Carcinoma

Purpose: There is no consensus on switching anticancer agents loaded onto drug carriers in transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). This study aimed to evaluate the safety and clinical outcomes of TACE with cisplatin-loaded microspheres (CLM-TACE) in HCC patients refractory to TACE with epirubicin-loaded microspheres (ELM-TACE). Methods: Between February 2008 and June 2010, 85 patients with unresectable HCC refractory to ELM-TACE were enrolled to undergo CLM-TACE. The number of ELM-TACE sessions until judgment of resistance ranged from 1 to 4 (median, 2.1). CLM-TACE was performed using 50-100-{mu}m superabsorbent polymer microspheres loaded with 1 mg cisplatin/1 mg microspheres together with hepatic arterial infusion of 25 mg cisplatin and 500 mg 5-fluorouracil per patient. Tumor responses were evaluated by computed tomography according to the European Association for the Study of the Liver criteria. Results: The median number of CLM-TACE treatment sessions was 1.8 (range, 1-5), and the mean total dose of cisplatin per session was 42.8 mg (range, 30.0-59.0). After 6 months, 3 (3.5%) patients achieved complete response, 31 (36.5%) had partial response, 15 (17.6%) had stable disease, and 36 (42.4%) had progressive disease. The median overall survival and time to treatment failure after initial CLM-TACE were 13.3 and 7.2 months, respectively. Overall, 9.4% of patients experienced grade 3/4 adverse events. Conclusions: witching the loaded agent from epirubicin to cisplatin is a safe, well-tolerated, and efficacious treatment strategy for salvage TACE with drug-eluting microspheres in HCC patients refractory to ELM-TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Chemoembolization (TACE) of Colorectal Cancer Liver Metastases by Irinotecan-Eluting Microspheres in a Salvage Patient Population

Purpose: This prospective study evaluated the effectiveness and safety of TACE using irinotecan loaded superabsorbent polymer (SAP) microspheres for treatment of colorectal cancer liver metastases (CCLM) in a salvage setting of patients. Methods: A total of 71 TACE procedures were performed in 29 patients with liver only or liver-dominant CCLM. In all patients, systemic chemotherapy before TACE had failed. Two hundred milligrams of irinotecan were loaded into 50–100 mg of SAP microspheres (HepaSphere™ Microspheres) considering tumor size and vascularization. TACE was performed selectively with respect to tumor distribution. Response was evaluated following RECIST and EASL criteria, respectively. Median follow-up after last TACE was 8 (range 1–54) months. All patients had died at time of analysis. Results: All TACE procedures were performed successfully; 35–400 mg (mean 168.3 mg) of irinotecan loaded in 13–100 mg (mean 48.3 mg) SAP microspheres were injected during individual sessions. No major complications occurred. Three, 6, and 12 months after first TACE complete and partial response was present in 72, 32 %, 0 of patients by EASL criteria and stable disease was seen in 86, 48, and 8 % with no complete and no partial response by RECIST criteria. Median overall survival after first TACE was 8 months, and median time to progression was 5 months. Median overall survival was longer in patients with limited (<25 %) compared with extensive (>50 %) intrahepatic disease (21 vs. 5 months, p < 0.005). Conclusions: TACE using irinotecan loaded SAP microspheres is safe and effective in terms of tumor necrosis. Survival benefit in a salvage setting seems to be limited in patients with advanced intrahepatic tumor load.

62 RADIOLOGY AND NUCLEAR MEDICINE↗