Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METROLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Investigation of Computational Corrections to X-Ray Computed Tomography for Dimensional Metrology of Complex Additively Manufactured Parts

X-ray computed tomography (CT) is a nondestructive evaluation technique that may be used to image complex internal features without the line-of-sight restrictions inherent in conventional optical and contact (stylus) metrology instrumentation. Applications of CT metrology include material defects (porosity), dimensions and surface texture. However, scan artifacts, such as streaking, caused primarily by beam hardening and scatter, limit the accuracy of CTbased metrology. Reduction of these artifacts would improve the accuracy material properties and dimensional metrology information. This paper reports on the development of additively manufactured (AM) Ti5553 and 316L measurement phantoms with integral lattice (lattice) structures specifically designed to exhibit these artifacts. The phantoms were scanned in three CT systems and a scanning-probe CMM measurement. Surfaces generated from uncorrected CT data exhibited “dimple” defects that are not present in the CMM measurement. Correction methods were developed in Livermore Tomography Tools (LTT) software and this paper reports on the successful correction of these artifacts. This work is expected to have application in areas where characterization of defects, dimensions and surface texture using CT are critical.

42 ENGINEERING↗

On-orbit Metrology and Calibration Requirements for Space Station Activities Definition Study

The Space Station is the focal point for the commercial development of space. The long term routine operation of the Space Station and the conduct of future commercial activities suggests the need for in-space metrology capabilities analogous when possible to those on-Earth. The ability to perform periodic calibrations and measurements with proper traceability is imperative for the routine operation of the Space Station. An initial review, however, indicated a paucity of data related to metrology and calibration requirements for in-space operations. This condition probably exists because of the highly developmental aspect of space activities to date, their short duration, and nonroutine nature. The on-orbit metrology and calibration needs of the Space Station were examined and assessed. In order to achieve this goal, the following tasks were performed: an up-to-date literature review; identification of on-orbit calibration techniques; identification of sensor calibration requirements; identification of calibration equipment requirements; definition of traceability requirements; preparation of technology development plans; and preparation of the final report. Significant information and major highlights pertaining to each task is presented. In addition, some general (generic) conclusions/observations and recommendations that are pertinent to the overall in-space metrology and calibration activities are presented.

Cotty, G. M.↗

Apollo Metrology Program

This paper introduces the metrology requirements in the recently published Apollo Program handbook, NHB 5400.2, entitled, 'Apollo Metrology Requirements Manual.' The major elements and control practices required for a comprehensive metrology system are identified. The elements are presented to you with sufficient detail of control practices to provide the scope of a total metrology program. The Manual is for implementation by the Apollo Space Flight Centers, their testing sites and contractors. The benefits of implementing these requirements are equally applicable to any Government or industry standards and calibration laboratory operations.

Porter, W. A.↗

A Multichannel Averaging Phasemeter for Picometer Precision Laser Metrology

The Micro-Arcsecond Metrology (MAM) team at the Jet Propulsion Laboratory has developed a precision phasemeter for the Space Interferometry Mission (SIM). The current version of the phasemeter is well-suited for picometer accuracy distance measurements and tracks at speeds up to 50 cm/sec, when coupled to SIM's 1.3 micron wavelength heterodyne laser metrology gauges. Since the phasemeter is implemented with industry standard FPGA chips, other accuracy/speed trade-off points can be programmed for applications such as metrology for earth-based long-baseline astronomical interferometry (planet finding), and industrial applications such as translation stage and machine tool positioning. The phasemeter is a standard VME module, supports 6 metrology gauges, a 128 MHz clock, has programmable hardware averaging, and a maximum range of 232 cycles (2000 meters at 1.3 microns).

Halverson, Peter G.↗

Incoming Metrology of Segmented X-Ray Mandrels at MSFC

The Constellation-X Spectroscopy X-ray telescope (SXT) is designed to be built from X-ray optic segments. The X-ray segments will be fabricated from the segmented mandrels using a replication process. The purpose of the incoming metrology is to map the surface of the mandrels, so the performance of the X-ray optics produced can be predicted. Three Constellation-X segmented mandrels have been delivered to MSFC for incoming metrology. The segmented mandrels are 30-degree sections of a cylindrical surface and have diameters of 1.0 m, 1.2 m and 1.6 m. The maximum dimensions of the optical surface are 1.0 m axial length and 0.5 m azimuthal segment length. The metrology of the mandrels consists of the measurement of their slope differences, roundness, absolute radius, axial profile and microroughness. Accuracy goals for each type of measurement and the accuracy of the instruments used for the measurements will be discussed. The results of the mandrel metrology together with the performance predictions will be presented.

Gubarev, Mikhail↗

Optical Metrology for the Segmented Optics on the Constellation-X Spectroscopy X-Ray Telescope

We present the metrology requirements and metrology implementation necessary to prove out the reflector technology for the Constellation X(C-X) spectroscopy X-ray telescope (SXT). This segmented, 1.6m diameter highly nested Wolter-1 telescope presents many metrology and alignment challenges. In particular, these mirrors have a stringent imaging error budget as compared to their intrinsic stiffness; This is required for Constellation-X to have sufficient effective area with the weight requirement. This has implications for the metrology that can be used. A variety of contract and noncontact optical profiling and interferometric methods are combined to test the formed glass substrates before replication and the replicated reflector segments.The reflectors are tested both stand-alone and in-situ in an alignment tower.Some of these methods have not been used on prior X-ray telescopes and some are feasible only because of the segmented approach used on the SXT. Methods discussed include high precision coordinate measurement machines using very low force or optical probe axial interferometric profiling azimuthal circularity profiling and use of advanced null optics such as conical computer generated hologram (CGHs).

Content, David↗

Metrology System for a Large, Somewhat Flexible Telescope

A proposed metrology system would be incorporated into a proposed telescope that would include focusing optics on a rigid bench connected via a deployable mast to another rigid bench holding a focal-plane array of photon counting photodetectors. Deformations of the deployable mast would give rise to optical misalignments that would alter the directions (and, hence, locations) of incidence of photons on the focal plane. The metrology system would measure the relative displacement of the focusing- optics bench and the focal-plane array bench. The measurement data would be used in post-processing of the digitized photodetector outputs to compensate for the mast-deformation-induced changes in the locations of incidence of photons on the focal plane, thereby making it possible to determine the original directions of incidence of photons with greater accuracy. The proposed metrology system is designed specifically for the Nuclear Spectroscopic Telescope Array (NuSTAR) a proposed spaceborne x-ray telescope. The basic principles of design and operation are also applicable to other large, somewhat flexible telescopes, both terrestrial and spaceborne. In the NuSTAR, the structural member connecting the optical bench and the photodetector array would be a 10-m-long deployable mast, and there is a requirement to keep errors in measured directions of incidence of photons below 10 arc seconds (3 sigma). The proposed system would include three diode lasers that would be mounted on the focusing-optics bench. For clarity, only one laser is shown in the figure, which is a greatly simplified schematic diagram of the system. Each laser would be aimed at a position-sensitive photodiode that would be mounted on the detector bench alongside the aforementioned telescope photodetector array. The diode lasers would operate at a wavelength of 830 nm, each at a power of 200 mW. Each laser beam would be focused to a spot of .1-mm diameter on the corresponding position-sensitive photodiode. To reduce the effect of sunlight on the measurements, a one-stage light baffle and an 830-nm transmission filter of 10-nm bandwidth would be placed in front of the position- sensitive photodiode. For each metrology reading, the output of the position-sensitive detector would be sampled and digitized twice: once with the lasers turned on, then once with the lasers turned off. The data from these two sets of samples would be subtracted from each other to further reduce the effects of sun glints or other background light sources.

Liebe, Carl Christian↗

Metrology of IXO Mirror Segments

For future x-ray astrophysics mission that demands optics with large throughput and excellent angular resolution, many telescope concepts build around assembling thin mirror segments in a Wolter I geometry, such as that originally proposed for the International X-ray Observatory. The arc-second resolution requirement posts unique challenges not just for fabrication, mounting but also for metrology of these mirror segments. In this paper, we shall discuss the metrology of these segments using normal incidence metrological method with interferometers and null lenses. We present results of the calibration of the metrology systems we are currently using, discuss their accuracy and address the precision in measuring near-cylindrical mirror segments and the stability of the measurements.

Chan, Kai-Wing↗

Stitching interferometry for synchrotron mirror metrology at National Synchrotron Light Source II (NSLS-II)

With the fast development of diffraction-limited storage rings and free electron lasers, the requirement for ultimate quality X-ray mirror is getting higher and the mirror surface needs to approach the sub-nm root mean square height specifications. Here, these ultimate specifications challenge the X-ray mirror metrology community. In this work, we present our developed dedicated stitching metrology platform for X-ray mirror metrology. Various stitching methods with different stitching parameters are investigated in our stitching interferometric system. Some experimental results are given to demonstrate its validity and performance. According to the measurement results, the repeatability of measuring a flat mirror in the software stitching mode is at 0.1 nm RMS level. In relative angle determinable stitching mode when measuring a curved mirror with its radius of curvature varying from 50 m to 175 m, the repeatability is around 1 nm RMS.

42 ENGINEERING↗

Advancing extreme pulsed lasers through measurements: summary of the pulsed laser metrology workshop

In this report we present consensus findings produced during the pulsed laser metrology (PLM) workshop (Boulder, CO, USA, August 2025). The workshop was a meeting of 35 scientists from private industry, academia, and U.S. government to compile a list of the metrology needs to support extreme pulsed laser development and implementation. We define ‘extreme pulsed lasers’ loosely as those with peak powers above 1 TW or multi-Joule pulse energies. Such lasers are being increasingly used and investigated for use in high energy particle acceleration, short wavelength radiation generation, laser-based fusion, etc. The rapid growth of these fields and the proliferation of extreme lasers for these applications, coupled with the extreme electric fields they generate and relative scarcity of such lasers, presents unique challenges to accuracy in their measurement. The PLM workshop was a two-day event designed to hear from users, developers, and researchers on the current state of optical metrology associated with these extreme pulsed lasers. The goal was to identify the most important measurement challenges limiting development and implementation of these lasers in practical applications. We report here the conclusions and recommendations of this workshop. The hope is that this document will become the first of many iterations which track the status of measurement needs supporting extreme pulsed lasers.

Lasers↗

Sub-microradian Surface Slope Metrology with the ALS Developmental Long Trace Profiler

Development of X-ray optics for 3rd and 4th generation X-ray light sources with a level of surface slope precision of 0.1-0.2 {micro}rad requires the development of adequate fabrication technologies and dedicated metrology instrumentation and methods. Currently, the best performance of surface slope measurement has been achieved with the NOM (Nanometer Optical Component Measuring Machine) slope profiler at BESSY (Germany) [1] and the ESAD (Extended Shear Angle Difference) profiler at the PTB (Germany) [2]. Both instruments are based on electronic autocollimators (AC) precisely calibrated for the specific application [3] with small apertures of 2.5-5 mm in diameter. In the present work, we describe the design, initial alignment and calibration procedures, the instrumental control and data acquisition system, as well as the measurement performance of the Developmental Long Trace Profiler (DLTP) slope measuring instrument recently brought into operation at the Advanced Light Source (ALS) Optical Metrology Laboratory (OML). Similar to the NOM and ESAD, the DLTP is based on a precisely calibrated autocollimator. However, this is a reasonably low budget instrument used at the ALS OML for the development and testing of new measuring techniques and methods. Some of the developed methods have been implemented into the ALS LTP-II (slope measuring long trace profiler [4]) which was recently upgraded and has demonstrated a capability for 0.25 {micro}rad surface metrology [5]. Performance of the DLTP was verified via a number of measurements with high quality reference mirrors. A comparison with the corresponding results obtained with the world's best slope measuring instrument, the BESSY NOM, proves the accuracy of the DLTP measurements on the level of 0.1-0.2 {micro}rad depending on the curvature of a surface under test. The directions of future work to develop a surface slope measuring profiler with nano-radian performance are also discussed.

47 OTHER INSTRUMENTATION↗

Optical metrology at the NSLS-II

Rapid progress in synchrotron optics performance places a high demand on optical characterization techniques used to validate surface parameters prior to installation of the X-ray optics. It is now necessary to characterize optical surface figure and slope errors and roughness on meter-long optics over spatial frequencies as short as 0.1 {micro}m The new NSLS-II Optical Metrology Laboratory (OML) includes instruments for measuring: (1) long spatial frequency figure errors with a ZYGO MST Fizeau-type 4* interferometer, capable of 0.1 nm sensitivity, (2) mid spatial frequencies with an upgraded ZYGO NewView 6300 white light interferometric microscope, capable of reaching 0.1 nm accuracy at a lateral resolution of 1 {micro}m, (3) high frequency roughness with an AFM (Nanosurf AG) with linearity better than 0.2% over the 80 {micro}m measurement area and sensitivity approaching 0.01 nm, and (4) slope errors with a long trace profiler currently under development that will be able to reach 50 nrad slope error accuracy. At present, the OML supports the NSLS-II R&D efforts and provides ongoing testing for NSLS optics. Future plans include the construction of a specialized metrology beamline for at-wavelength metrology, radiometry, in situ surface figuring, crystal optics characterization, and instrumentation development.

43 PARTICLE ACCELERATORS↗

Comprehensive assessment of metrology techniques for heliostat efficiency and performance evaluation

Concentrating solar power plants, specifically central receiver type systems and their heliostat field, are struggling with negative reputation in the USA, due to perceived underperformance and reliability issues. This is in part due to a lack of standards for performance assessment as well as overly simplified techno-economical models. A better understanding of influences and losses along the solar radiation path from the sun, across the solar collector to the receiver, increases the fidelity of heliostat efficiency assessment as well as solar field performance predictions. Such data are currently scarce and require a complete set of metrology capabilities to evaluate direct solar irradiance, sun shape, atmospheric attenuation, reflectance, collector shape, slope errors and total beam dispersion. In preparation for establishing a 3rd party metrology platform in collaboration with Sandia National Labs, NLR conducted a scoping study on available metrology. We present an extensive overview of techniques and commercial systems for each category. Our work includes an analysis to increase understanding of strengths and limitations of the many techniques used for surface shape and slope measurement. This applies to a controlled, indoor or outdoor laboratory environment assessing a single heliostat.

14 SOLAR ENERGY↗

Combined dry plasma etching and online metrology for manufacturing highly focusing x-ray mirrors

A new figuring station was designed and installed at the ESRF beamline BM05. It allows the figuring of mirrors within an iterative process combining the advantage of online metrology with dry etching. The complete process takes place under a vacuum environment to minimize surface contamination while non-contact surfacing tools open up the possibility of performing at-wavelength metrology and eliminating placement errors. The aim is to produce mirrors whose slopes do not deviate from the stigmatic profile by more than 0.1 µrad rms while keeping surface roughness in the acceptable limit of 0.1-0.2 nm rms. The desired elliptical mirror surface shape can be achieved in a few iterations in about a one day time span. This paper describes some of the important aspects of the process regarding both the online metrology and the etching process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current-based metrology with two-terminal mesoscopic conductors

The traditional approach to quantum parameter estimation focuses on the quantum state, deriving fundamental bounds on precision through the quantum Fisher information. In most experimental settings, however, performing arbitrary quantum measurements is highly unfeasible. In open quantum systems, an alternative approach to metrology involves the measurement of stochastic currents flowing from the system to its environment. However, the present understanding of current-based metrology is mostly limited to Markovian master equations. Considering a parameter estimation problem in a two-terminal mesoscopic conductor, we identify the key elements that determine estimation precision within the Landauer-Büttiker formalism. Crucially, this approach allows us to address arbitrary coupling and temperature regimes. Furthermore, we obtain analytical results for the precision in linear-response and zero-temperature regimes. For the specific parameter estimation task that we consider, we demonstrate that the boxcar transmission function is optimal for current-based metrology in all parameter regimes.

Landauer formula↗

A Systems Approach to Estimating the Uncertainty Limits of X-Ray Radiographic Metrology

Micro- and nanomanufacturing capabilities have rapidly expanded over the past decade to include complex three-dimensional (3D) structure fabrication; however, the metrology required to accurately assess these processes via part inspection and characterization has struggled to keep pace. X-ray computed tomography (CT) is considered an ideal candidate for providing the critically needed metrology on the smallest scales, especially internal features, or inaccessible regions. X-ray CT supporting micro- and nanomanufacturing often push against the poorly understood resolution and variation limits inherent to the machines, which can distort or hide fine structures. In this study, we have developed and experimentally verify a comprehensive analytical uncertainty propagation signal variation flow graph (SVFG) model for X-ray radiography in this work to better understand resolution and image variability limits on the small scale. The SVFG approach captures, quantifies, and predicts variations occurring in the system that limit metrology capabilities, particularly in the micro/nanodomain. This work is the first step to achieving full uncertainty modeling of CT reconstructions and provides insight into improving X-ray attenuation imaging systems. The SVFG methodology framework is applied to generate a complete basis set of functions describing the major sources of variation in radiographs. Five models are identified, covering variation in energy, intensity, length, blur, and position. Radiographic system experiments are defined to measure the parameters required by the SVFGs. Best practices are identified for these measurements. The SVFG models are confirmed via direct measurement of variation to predict variation within 30% on average.

47 OTHER INSTRUMENTATION↗

Kite: Status of the External Metrology Testbed for SIM

Kite is a system level testbed for the External Metrology system of the Space Interferometry Mission (SIM). The External Metrology System is used to track the fiducial that are located at the centers of the interferometer's siderostats. The relative changes in their positions needs to be tracked to tens of picometers in order to correct for thermal measurements, the Kite testbed was build to test both the metrology gauges and out ability to optically model the system at these levels. The Kite testbed is an over-constraint system where 6 lengths are measured, but only 5 are needed to determine the system. The agreement in the over-constrained length needs to be on the order of 140 pm for the SIM Wide-Angle observing scenario and 8 pm for the Narrow-Angle observing scenario. We demonstrate that we have met the Wide-Angle goal with our current setup. For the Narrow-Angle case, we have only reached the goal for on-axis observations. We describe the testbed improvements that have been made since our initial results, and outline the future Kite changes that will add further effects that SIM faces in order to make the testbed more SIM like.

metrology↗

Mask Design for the Space Interferometry Mission Internal Metrology

This slide presentation reviews the mask design used for the internal metrology of the Space Interferometry Mission (SIM). Included is information about the project, the method of measurements with SIM, the internal metrology, numerical model of internal metrology, wavefront examples, performance metrics, and mask design

interferometry↗