Balanced Flow Meters without Moving Parts

Balanced flow meters are recent additions to an established class of simple, rugged flow meters that contain no moving parts in contact with flow and are based on measurement of pressure drops across objects placed in flow paths. These flow meters are highly accurate, minimally intrusive, easily manufacturable, and reliable. A balanced flow meter can be easily mounted in a flow path by bolting it between conventional pipe flanges. A balanced flow meter can be used to measure the flow of any of a variety of liquids or gases, provided that it has been properly calibrated. Relative to the standard orifice-plate flow meter, the balanced flow meter introduces less turbulence and two times less permanent pressure loss and is therefore capable of offering 10 times greater accuracy and repeatability with less dissipation of energy. A secondary benefit of the reduction of turbulence is the reduction of vibration and up to 15 times less acoustic noise generation. Both the balanced flow meter and the standard orifice-plate flow meter are basically disks that contain holes and are instrumented with pressure transducers on their upstream and downstream faces. The most obvious difference between them is that the standard orifice plate contains a single, central hole while the balanced flow meter contains multiple holes. The term 'balanced' signifies that in designing the meter, the sizes and locations of the holes are determined in an optimization procedure that involves balancing of numerous factors, including volumetric flow, mass flow, dynamic pressure, kinetic energy, all in an effort to minimize such undesired effects as turbulence, pressure loss, dissipation of kinetic energy, and non-repeatability and nonlinearity of response over the anticipated range of flow conditions. Due to proper balancing of these factors, recent testing demonstrated that the balanced flow-meter performance was similar to a Venturi tube in both accuracy and pressure recovery, but featured reduced cost and pipe-length requirements.

Kelley, Anthony R.↗

Metering Best Practices: A Guide to Achieving Utility Resource Efficiency, Release 3.0

DOE FEMP guide for metering best practices aligned with the DOE Metering Guidance revision required by the 12/2013 Presidential Memo. The purpose of this guide is to provide information on effective energy and water metering strategies, relevant metering technologies and communications, how to collect and use metered data, and how to develop a metering plan. This guide is designed to serve as a resource for facility, energy, and water management and technical staff. It does not try to represent the universe of metering-related material. Rather, it attempts to: Provide background information on why metering is important, Provide guidance on the structure of an effective metering program, Provide information on metering and communications technologies, and Highlight common uses of metered data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization of Impedance Void Meter Performance in Two-Phase Flow Measurement

Over the past sixty years, exclusive work has been done on two-phase flow measurement and plenty of measurement methods have been developed. Among them, impedance void meter is considered to be a simple instrument with a quick and reliable response. Impedance measurement technique in two-phase flow has existed for more than five decades. Impedance void meter consists of two electrodes flush mounted on the flow channel which allows measurements to be performed over the entire flow area. In principle, impedance void meter is based on the different electrical conductance of water and air. The two electrodes connected with cable and voltage supplies and the air-water mixture between them form a complete circuit. The change of gas fraction occupied in the flow area is reflected by the change of impedance in this part, and then the change of the voltage signal of the circuit. Using the relationship between void fraction and voltage signal, area averaged void fraction can be measured. In a previous study by Bolman et al., the flow pattern was found that has an effect on the performance of the impedance void meter. This is due to the difference of the flow structure that affects the impedance of the flow area. Olsen suggested that the impedance void meter should fulfill the following factors in order to get good measurement results: gas phase is finely dispersed in the measuring flow area; the channel cross section should be uninterrupted; there should be several bubble diameters between sources of current. For pipe measurement, it is impossible to meet all these requirement. In this case, it is necessary to use other independent void fraction measurement methods to calibrate impedance void meter. However, the calibration result varies for different flow patterns; thus for those situations in which identifying the flow pattern is difficult, the results may not be reliable. The possible solution should be found in an aspect of impedance void meter design itself. Much work has been done focusing on the geometric design of impedance void meters. This study found that the distance between the two electrodes of the impedance void meter has an effect on the measurement performance. The primary focus of this study is to characterize the performance and measurement range of an impedance void meter in regards to its geometry aspect. In order to achieve this goal, a sensitivity study of the electrode distance was performed by numerical simulation. Based on the simulation results, an experiment was performed using an impedance void meter with different electrode distances. Additionally, a gamma densitometer and a multi single-sensor conductivity probe were also applied for the measurement comparison. Drift flux model was also used for the experimental results comparison. (authors)

42 ENGINEERING↗

ATD-2 Surface Scheduling and Metering Concept

This presentation describes the concept of ATD-2 tactical surface scheduling and metering. The concept is composed of several elements, including data exchange and integration; surface modeling; surface scheduling; and surface metering. The presentation explains each of the elements. Surface metering is implemented to balance demand and capacity• When surface metering is on, target times from surface scheduler areconverted to advisories for throttling demand• Through the scheduling process, flights with CTOTs will not get addedmetering delay (avoids potential for ‘double delay’)• Carriers can designate certain flights as exempt from metering holds• Demand throttle in Phase 1 at CLT is through advisories sent to rampcontrollers for pushback instructions to the flight deck– Push now– Hold for an advised period of time (in minutes)• Principles of surface metering can be more generally applied to otherairports in the NAS to throttle demand via spot-release times (TMATs Strong focus on optimal use of airport resources• Flexibility enables stakeholders to vary the amount of delay theywould like transferred to gate• Addresses practical aspects of executing surface metering in aturbulent real world environment• Algorithms designed for both short term demand/capacityimbalances (banks) or sustained metering situations• Leverage automation to enable surface metering capability withoutrequiring additional positions• Represents first step in Tactical/Strategic fusion• Provides longer look-ahead calculations to enable analysis ofstrategic surface metering potential usage

Departure↗

Environmental projects, volume 10. Environmental assessment: New 34-meter antenna at Apollo site

The Goldstone Deep Space Communications Complex (GDSCC) is part of NASA's Deep Space Network (DSN), one of the world's largest and most sensitive scientific telecommunications and radio navigation networks. A detailed description of the GDSCC is presented. At present the Venus Station has an unused 9-meter antenna and a 26-meter (85 ft) antenna known as DSS-13. Construction of a new 34-meter (111.5 ft) antenna at the Venus site is under way to replace the present DSS-13 26-meter antenna. The proposed construction at the Apollo Site of a new, high efficiency, 34-meter, multifrequency beam waveguide-type antenna to replace the aging, 20-year old, DSS-12 34-meter antenna located at the Echo Site is analyzed. This new 34-meter antenna, to be constructed at the Apollo Site and to be known as DSS-18, will be of a design similar to the new DSS-13 34-meter antenna now being constructed at the Venus Site. When the new 34-meter antenna is completed and operational at the Apollo Site (planned for 1993), the old DSS-12 34-meter antenna at the Echo Site will be decommissioned, dismantled, and removed.

Source record↗

Tactical Surface Metering Procedures for Charlotte Douglas International Airport

NASA has been collaborating with the Federal Aviation Administration (FAA) and aviation industry partners to develop and demonstrate new concepts and technologies for the Integrated Arrival, Departure, and Surface (IADS) traffic management capabilities under the Airspace Technology Demonstration 2 (ATD-2) project. The primary goal of the ATD-2 project is to improve the predictability and the operational efficiency of the air traffic system in metroplex environments while maintaining or improving throughput by enhancing and integrating arrival, departure and surface prediction, scheduling, and management systems. In the Phase 1 Baseline IADS Demonstration, the tactical surface scheduling capability and the user interfaces for ramp controllers and ramp traffic managers were implemented for ramp operations. The purpose of the tactical surface scheduling capability is to provide the airline ramp controller with aircraft pushback advisories that prevent surface congestion and to respond to surface and airspace constraints that become known over relatively short time horizons. For this purpose, the tactical surface metering tool first estimates the capacity of current and near-future runway resources from flight schedule and surveillance data. With demand forecasts and predicted taxi trajectories, this tool computes an efficient runway schedule of aircraft in the planning horizon based on their readiness, Earliest Off-Block Times (EOBTs), and a ration by schedule (RBS) rule. Details on the implementation of the Tactical Surface Metering tool will be provided in the full paper. Both pushback and recommended hold times advisories provided by this surface metering tool are shown on the user interfaces for the ramp controller and the ramp traffic manager, called Ramp Traffic Console (RTC) and Ramp Manager Traffic Console (RMTC), respectively. There is excess queue time in the system due to demand capacity imbalance, this time can be taken as a hold on the runway queue or at the gate and was referred to as the Metering Value. This metering value can be adjusted by the Ramp Manager in collaboration with Air Traffic Controller-Tower Traffic Management Coordinator (TMC). They selected a set of metering values as default values for the tool during human-in-the-loop simulation. As the metering value increases, there is a decrease in the gate hold and increase in the queue time at the runway. Procedures and Information needs related to managing the surface metering procedures were researched in the simulated environment. These procedures will be compared to the procedures adopted at Charlotte Douglas International Airport when the tools were deployed and adopted in November 2017 for one departure push bank per day. Feedback regarding initial issues, information needs such as the need to see EOBTs on the flight data tags and how they compare to scheduled times will also be discussed in the full paper. Initial results will be provided regarding the choice of the metering value and how it was adjusted on a daily basis and what procedures evolved will also be presented in the paper.

surface metering↗

Weather Impact on Airport Arrival Meter Fix Throughput

Time-based flow management provides arrival aircraft schedules based on arrival airport conditions, airport capacity, required spacing, and weather conditions. In order to meet a scheduled time at which arrival aircraft can cross an airport arrival meter fix prior to entering the airport terminal airspace, air traffic controllers make regulations on air traffic. Severe weather may create an airport arrival bottleneck if one or more of airport arrival meter fixes are partially or completely blocked by the weather and the arrival demand has not been reduced accordingly. Under these conditions, aircraft are frequently being put in holding patterns until they can be rerouted. A model that predicts the weather impacted meter fix throughput may help air traffic controllers direct arrival flows into the airport more efficiently, minimizing arrival meter fix congestion. This paper presents an analysis of air traffic flows across arrival meter fixes at the Newark Liberty International Airport (EWR). Several scenarios of weather impacted EWR arrival fix flows are described. Furthermore, multiple linear regression and regression tree ensemble learning approaches for translating multiple sector Weather Impacted Traffic Indexes (WITI) to EWR arrival meter fix throughputs are examined. These weather translation models are developed and validated using the EWR arrival flight and weather data for the period of April-September in 2014. This study also compares the performance of the regression tree ensemble with traditional multiple linear regression models for estimating the weather impacted throughputs at each of the EWR arrival meter fixes. For all meter fixes investigated, the results from the regression tree ensemble weather translation models show a stronger correlation between model outputs and observed meter fix throughputs than that produced from multiple linear regression method.

Machine Learning Model.↗

Using Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices in Buildings

Miscellaneous and electronic devices consume about one-third of the primary energy used in U.S. buildings, and their energy use is increasing faster than other end-uses. Despite the success of policies, such as Energy Star, that promote more efficient miscellaneous and electronic products, much remains to be done to address the energy use of these devices if we are to achieve our energy and carbon reduction goals. Developing efficiency strategies for these products depends on better data about their actual usage, but very few studies have collected field data on the long-term energy used by a large sample of devices due to the difficulty and expense of collecting device-level energy data. This paper describes the development of an improved method for collecting device-level energy and power data using small, relatively inexpensive wireless power meters. These meters form a mesh network based on Internet standard protocols and can form networks of hundreds of metering points in a single building. Because the meters are relatively inexpensive and do not require manual data downloading, they can be left in the field for months or years to collect long time-series energy use data. In addition to the metering technology, we also describe a field protocol used to collect comprehensive, robust data on the miscellaneous and electronic devices in a building. The paper presents sample results from several case study buildings, in which all the plug-in devices for several homes were metered, and a representative sample of several hundred plug-in devices in a commercial office building were metered for several months.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance of Thermal Mass Flow Meters in a Variable Gravitational Environment

The performance of five thermal mass flow meters, MKS Instruments 179A and 258C, Unit Instruments UFM-8100, Sierra Instruments 830L, and Hastings Instruments HFM-200, were tested on the KC-135 Reduced Gravity Aircraft in orthogonal, coparallel, and counterparallel orientations relative to gravity. Data was taken throughout the parabolic trajectory where the g-level varied from 0.01 to 1.8 times normal gravity. Each meter was calibrated in normal gravity in the orthogonal position prior to flight followed by ground testing at seven different flow conditions to establish a baseline operation. During the tests, the actual flow rate was measured independently using choked-flow orifices. Gravitational acceleration and attitude had a unique effect on the performance of each meter. All meters operated within acceptable limits at all gravity levels in the calibrated orthogonal position. However, when operated in other orientations, the deviations from the reference flow became substantial for several of the flow meters. Data analysis indicated that the greatest source of error was the effect of orientation, followed by the gravity level. This work emphasized that when operating thermal flow meters in a variable gravity environment, it is critical to orient the meter in the same direction relative to gravity in which it was calibrated. Unfortunately, there was no test in normal gravity that could predict the performance of a meter in reduced gravity. When operating in reduced gravity, all meters indicated within 5 percent of the full scale reading at all flow conditions and orientations.

Brooker, John E.↗

Manufacturing Challenges and Benefits When Scaling the HIAD Stacked-Torus Aeroshell to a 15 Meter Class System

Over a decade of work has been conducted in the development of NASA's Hypersonic Inflatable Aerodynamic Decelerator (HIAD) deployable aeroshell technology. This effort has included multiple ground test campaigns and flight tests culminating in the HIAD project's second generation (Gen-2) aeroshell system. The HIAD project team has developed, fabricated, and tested stacked-torus inflatable structures (IS) with flexible thermal protection systems (F-TPS) ranging in diameters from 3-6 meters, with cone angles of 60 and 70 degrees. To meet NASA and commercial near-term objectives, the HIAD team must scale the current technology up to 12-15 meters in diameter. Therefore, the HIAD project's experience in scaling the technology has reached a critical juncture. Growing from a 6-meter to a 15-meter class system will introduce many new structural and logistical challenges to an already complicated manufacturing process. Although the general architecture and key aspects of the HIAD design scale well to larger vehicles, details of the technology will need to be reevaluated and possibly redesigned for use in a 15-meter-class HIAD system. These include: layout and size of the structural webbing that transfers load throughout the IS, inflatable gas barrier design, torus diameter and braid construction, internal pressure and inflation line routing, adhesives used for coating and bonding, and F-TPS gore design and seam fabrication. The logistics of fabricating and testing the IS and the F-TPS also become more challenging with increased scale. Compared to the 6-meter aeroshell (the largest HIAD built to date), a 12-meter aeroshell has four times the cross-sectional area, and a 15-meter one has over six times the area. This means that fabrication and test procedures will need to be reexamined to account for the sheer size and weight of the aeroshell components. This will affect a variety of steps in the manufacturing process, such as: stacking the tori during assembly, stitching the structural webbing, initial inflation of tori, and stitching of F-TPS gores. Additionally, new approaches and hardware will be required for handling and ground testing of both individual tori and the fully assembled HIADs. There are also noteworthy benefits of scaling up the HIAD aeroshell to a 15m-class system. Two complications in working with handmade textile structures are the non-linearity of the material components and the role of human accuracy during fabrication. Larger, more capable, HIAD structures should see much larger operational loads, potentially bringing the structural response of the material components out of the non-linear regime and into the preferred linear response range. Also, making the reasonable assumption that the magnitude of fabrication accuracy remains constant as the structures grow, the relative effect of fabrication errors should decrease as a percentage of the textile component size. Combined, these two effects improve the predictive capability and the uniformity of the structural response for a 12-15-meter HIAD. In this presentation, a handful of the challenges and associated mitigation plans will be discussed, as well as an update on current manufacturing and testing that addressing these challenges.

Infatables↗

Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve

A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

Song, Li↗

Advanced Metering Infrastructure for Distribution Planning and Operation: Closing the Loop on Grid-Edge Visibility

In the recent history of electric utilities, the potential to have visibility of the grid edge is gaining significance for the reliable planning and operation of a clean energy smart grid. Before the recent large-scale customer adoption of distributed energy resources (DERs), distribution networks were planned with a simpler fit-and-forget philosophy. The importance of customer-sited DERs to achieve climate change goals marks a major shift for utility operations. Changes to traditional fit-and-forget planning paradigms require better availability of grid-edge data. Smart metering is an enterprise-wide tool that is enabling visibility when and where it has been most needed. As of 2020, the rollout of smart metering, or advanced metering infrastructure (AMI), had reached more than 100 million meters in the United States, and nearly half of all electricity customers are now equipped with a smart meter (Figure 1). Smart meters are quickly becoming a ubiquitous data capture feature of smart grids. AMI enables utilities to record and measure electricity usage and power-flow metrics at a minimum of hourly intervals and at least once a day. At a minimum, AMI enables interval metering, automatic meter reading enabling accurate and time-interval billing, and the ability to provide feedback on customer energy consumption.

advanced metering infrastructure↗

Tatsuno Coriolis Flow Meter Development Testing in High Pressure Hydrogen: Cooperative Research and Development Final Report

This project will provide test data on the new Tatsuno coriolis flow meter. This flow meter has been developed by Tatsuno for the purpose of achieving improved flow meter performance for 70 mega pascal (MPA) hydrogen dispensing. Testing will be conducted at the National Renewable Laboratory (NREL) Hydrogen Infrastructure Testing and Research Facility (HITRF) facility utilizing the hydrogen flow meter benchmark testing apparatus. The benchmarking apparatus utilizes a gravimetric method for measuring flow for direct comparison with flow meter output. Using the NREL meter benchmarking apparatus will allow direct comparison with data taken on previous versions of the Tatsuno coriolis flow meter product. Flow meter accuracy at 70 MPA hydrogen dispensers is an issue that has generated a lot of effort by both standards organizations and the station providers.

33 ADVANCED PROPULSION SYSTEMS↗

Homomorphic Encryption for Electrical Metering Aggregation: Protecting the Privacy of Building Tenants

Electrical meters are devices that measure consumer electricity usage. The data collected by these meters is necessary for utility billing and electrical grid management but can also be used to assess the environmental impact of buildings. Prior research has found that unprotected metering data could potentially be used to infer some information about the behaviors of building tenants by detecting changes in electricity usage. For example, a period of low electricity usage could suggest that the tenants are not in the building. As smart metering becomes more common, there is a growing need for data privacy protections for metering data that do not negatively impact the quality and availability of data used for energy management and billing applications. To identify potential solutions, we developed a Python-based data aggregation platform to analyze the potential efficacy of privacy-enhancing technologies for energy metering applications. This platform aggregates groups of metering sites into virtual buildings, which could potentially detach changes in electrical activity from individual tenants, making it more difficult to track the activity of a specific tenant. To further protect data during analysis, this project utilizes homomorphic encryption as part of its initial approach. Homomorphic encryption offers a means of protecting energy consumption data while permitting mathematical operations to be performed without the need to know the data contents. This allows for data to be processed into usable statistics without revealing energy consumption information. A series of homomorphic encryption libraries were evaluated to determine their applicability and limitations in the context of metering data. The use of these techniques may help to reassure consumers and encourage further adoption of smart grid infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Federal Metering Guidance

The Federal Metering Guidance documents the metering provisions in EO 13834, Efficient Federal Operations and other metering related statutory requirements. This document provides the meter-related reporting requirements for Federal agencies, specifies a method to verify the existence of currently installed building-level meters, provides guidelines on prioritizing the implementation of advanced energy and water meters, sets the schedule for agencies to update their five-year metering plans, provides the minimum requirements that agencies must meet when updating their five-year metering plans along with recommend elements for an effective plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Constancy of built-in luminance meter measurements in diagnostic displays

Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49 336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25 000 BLH and those with more than 25 000 BLH. Bias between meters was also evaluated. Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35 000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25 000 and greater than 25 000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35 000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Testing of the Europa Mission's Venturi Flow Meter

NASA's Marshall Space Flight Center (MSFC), in collaboration with NASA's Goddard Space Flight Center (GSFC), Fox Valve Development Corp. and Oxford Lasers, is developing a set of venturi flow meters for use on the Europa Mission's propulsion subsystem. The requirement for the venturi flow meters' throat diameters is approximately 0.040". An early risk reduction activity conducted by MSFC revealed that a venturi flow meter produced by FOX with a throat diameter near 0.040" had much higher pressure loss than venturi flow meters with larger throat diameters and venturis of similar throat diameter size but with no pressure taps (i.e. venturis with a throat length to diameter ratio of zero). In response, a series of venturi flow meters was fabricated and flow tested to gain insight into pressure recovery as it is affected by pressure port diameter, throat length and diffuser angle in an effort to improve the performance of a venturi flow meter. This presentation provides a summary of the venturi flow meter development activity including: a description of the test's objectives, a detailed description of each venturi configuration, a description of the manufacturing processes of the venturis, and observations from the test data. A summary of the current development activities will also be given, as well as the current development path forward. Ultimately, the knowledge gained through the fabrication and testing of these venturis provides guidance to design a flight venturi flow meters with pressure recoveries that is acceptable for the Europa flight application.

Diaz, C. E.↗