Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MASER RESONATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

67 records · Page 4

Stability and Phase Noise Tests of Two Cryo-Cooled Sapphire Oscillators

A cryocooled Compensated Sapphire Oscillator (CSO), developed for the Cassini Ka-band Radio Science experiment, and operating in the 8K - 10K temperature range was previously demonstrated to show ultra-high stability of sigma(sub y) = 2.5 x 10 (exp -15) for measuring times 200 seconds less than or equal to tau less than or equal to 600 seconds using a hydrogen maser as reference. We present here test results for a second unit which allows CSO short-term stability and phase noise to be measured for the first time. Also included are design details of a new RF receiver and an intercomparison with the first CSO unit. Cryogenic oscillators operating below about 10K offer the highest possible short term stability of any frequency sources. However, their use has so far been restricted to research environments due to the limited operating periods associated with liquid helium consumption. The cryocooled CSO is being built in support of the Cassini Ka-band Radio Science experiment and is designed to operate continuously for periods of a year or more. Performance targets are a stability of 3-4 x 10 (exp -15) (1 second less than or equal to tau less than or equal to 100 seconds) and phase noise of -73dB/Hz @ 1Hz measured at 34 GHz. Installation in 5 stations of NASA's deep space network (DSN) is planned in the years 2000 - 2002. In the previous tests, actual stability of the CSO for measuring times tau less than or equal to 200 seconds could not be directly measured, being masked by short-term fluctuations of the H-maser reference. Excellent short-term performance, however, could be inferred by the success of an application of the CSO as local oscillator (L.O.) to the JPL LITS passive atomic standard, where medium-term stability showed no degradation due to L.O. instabilities at a level of (sigma)y = 3 x 10 (exp -14)/square root of tau. A second CSO has now been constructed, and all cryogenic aspects have been verified, including a resonator turn-over temperature of 7.907 K, and Q of 7.4 x 10 (exp 8). These values compare to a turn-over of 8.821 K and Q of 1.0 x 10 (exp 9) for the first resonator. Operation of this second unit provides a capability to directly verify for the first time the short-term (1 second less than or equal to tau less than or equal to 200 seconds) stability and the phase noise of the CSO units. The RF receiver used in earlier tests was sufficient to meet Cassini requirements for tau greater than or equal to 10 seconds but had short-term stability limited to 2-4 x 10 (exp -14) at tau = 1 second, a value 10 times too high to meet our requirements. A new low-noise receiver has been designed to provide approximately equal to 10-15 performance at 1 second, and one receiver is now operational, demonstrating again short-term CSO performance with H maser-limited stability. Short-term performance was degraded in the old receiver due to insufficient tuning bandwidth in a 100MHZ quartz VCO that was frequency-locked to the cryogenic sapphire resonator. The new receivers are designed for sufficient bandwidth, loop gain and low noise to achieve the required performance.

Dick, G. John

Effect of RF Filtering on the Performance of Uncoded PCM/PM Telemetry Channels

A method for calculating the increase in received telemetry signal power required to compensate for the use of a radio frequency interference (RFI) filter in front of the DSN receiving system low-noise amplifier is described. The telemetry system for which the degradation is calculated is an uncoded PCM/PM system in which the NRZ data directly modulates the carrier at a modulation level which leaves a discrete carrier. A phase-locked loop in the RF receiver tracks the discrete carrier and coherently demodulates the PCM data. The RFI filter may be a series of Butterworth, Tchebychev, or Bessel low-pass, high-pass, band-pass, or band-reject filters, each with arbitrary bandwidth, number of poles, and, for band-pass or band-reject filters, resonant frequency. The only restriction is that the RFI filter must have only simple poles. Numerical results are presented for the RFI filters the DSN plans to place in front of the S-band FET, S-band maser, and X-band maser low noise amplifiers. The main conclusion is that the filters will produce negligible degradation at data rates below 4 Mbps.

Koerner, M. A.

Characteristics of advanced hydrogen maser frequency standards

Measurements with several operational atomic hydrogen maser standards have been made which illustrate the fundamental characteristics of the maser as well as the analysability of the corrections which are made to relate the oscillation frequency to the free, unperturbed, hydrogen standard transition frequency. Sources of the most important perturbations, and the magnitude of the associated errors, are discussed. A variable volume storage bulb hydrogen maser is also illustrated which can provide on the order of 2 parts in 10 to the 14th power or better accuracy in evaluating the wall shift. Since the other basic error sources combined contribute no more than approximately 1 part in 10 to the 14th power uncertainty, the variable volume storage bulb hydrogen maser will have net intrinsic accuracy capability of the order of 2 parts in 10 to the 14th power or better. This is an order of magnitude less error than anticipated with cesium standards and is comparable to the basic limit expected for a free atom hydrogen beam resonance standard.

Peters, H. E.

Ultra-stable Hg(+) trapped ion frequency standard

We report the development of a fieldable frequency standard based on Hg-199(+) ions confined in a hybrid r.f./dc linear ion trap. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the r.f. confining fields. A 160 mHz wide atomic resonance line for the 40.5 GHz clock transition is used to steer the output of a 5 MHz crystal oscillator to obtain a stability of 2 x 10 exp -15 for 24,000 s averaging times. For longer averaging intervals, measurements are limited by instabilities in available hydrogen maser frequency standards. Measurements with 37 mHz linewidth for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is at least as good as 1 x 10 exp -15.

Prestage, J. D.

Classical laser.

In this paper a completely classical model for laser action is discussed. An active medium consisting of classical anharmonic oscillators interacts with a classical electromagnetic field in a resonant cavity. Comparison with the case of a medium consisting of harmonic oscillators shows the significance of nonlinearities for producing self-sustained oscillations in the radiation field. The results for the classical model are found to be similar to those for a semiclassical model of the ammonia-beam maser. The conclusion is that laser action is not intrinsically a quantum-mechanical effect. The classical-laser theory as given in this paper can also be applied to the case of the electron-cyclotron maser.

Borenstein, M.

Tuning Concept for Resonant Cavities

Deviations from resonance detected by sampling phases. Automatic tuner feedback control system derives error signal from E and H plane probe signals. Control objective to maintain phase difference between E and H at 90 degrees. Technique estimated to sensitive to fractional frequency deviation of about 5 X 10-16 and applicable not only to masers but also other microwave elements, including klystrons, general purpose oscillators, and frequency standards.

Sydnor, R. L.

Frequency standards from industry over the next 25 years

Present and possible future performance for many of the existing and new commercial frequency standards is presented here. Recent progress in the gas cell atomic standards with regards to size and cost is significant and considerable improvement is expected. Cesium beam standards will benefit in stability and accuracy from optical pumping. Cooled hydrogen masers will offer extremely good stability. Advances in trapped ion and cesium fountain technologies make them good high performance candidates for the future. The quartz oscillator field is more mature and consequently performance improvements for the future are going to be less spectacular. Oscillators stabilized to GPS will have many applications. Recent performance of cooled microwave dielectric resonator oscillators is very good and they offer the promise of serving as flywheel oscillators for advanced performance atomic standards.

Cutler, Leonard S.

An electron cyclotron maser instability for astrophysical plasmas

The electron cyclotron maser instability is analyzed for a plasma which consists of a suprathermal electron component characterized by velocity-space anisotropies in directions both parallel and perpendicular to the ambient magnetic field, as well as a high-density thermal plasma in which omega sub e is approximately equal to Omega sub e (where omega sub e and Omega sub e are the electron plasma and cyclotron frequencies). The complete relativistic resonance condition is used and shown to result in a 'resonance ellipse' in momentum space. The instability is considered for both cold and warm suprathermal electron distributions, and for frequencies omega approximately equal to Omega sub e in the ordinary mode and omega approximately equal to 2(Omega sub e) in the fast extraordinary mode. It is shown that the growth rates are comparable for these harmonics over a wide range of parameters which, since they are escape modes of the plasma, can lead to comparable radiation intensities.

Freund, H. P.

Maser cavity servo-tuning system

Two collocated, weakly coupled probes, one loop and one dipole, detect the magnetic and electric fields inside a maser cavity. Signals from the probes are compared in phase, and the signal output from the phase detector is applied to a varactor, the reactance of which is coupled into the cavity by a microwave coupler. Alternatively, the varactor may be placed inside the cavity. Any deviation of phase from 90 deg as detected by the phase detector will then produce an error signal that will change the reactance coupled into the resonant cavity to change its reactance, and thus correct its resonance frequency. An alternative to using two probes is to use a single disk probe oriented to detect both the magnetic and electric fields, and thus provide the error signal directly.

Sydnor, R. L.

A kinetic cyclotron maser instability associated with a hollow beam of electrons

A kinetic cyclotron maser instability associated with a hollow-beam distribution function is studied. The instability differs from that discussed for the gyrotron device in two respects: in the present case the momentum dispersion is substantial, and furthermore there exists a low-energy background plasma. On the basis of physical arguments it can be demonstrated that the hollow-beam distribution is far more unstable than the loss cone distribution which has been extensively investigated in recent years. A criterion for maximum growth rate is established on the basis of consideration of the resonance ellipse. The validity of this criterion is supported by the results of numerical calculation.

Wu, C. S.

A simulation study of the loss cone driven cyclotron maser applied to auroral kilometric radiation

The linear growth and nonlinear saturation of electromagnetic radiation amplified by a hot (5-20 keV) population of electrons possessing a loss cone velocity distribution in the presence of a cold (20-500 eV) electron population are studied. A relativistic electromagnetic simulation code is used to study the emission process. Three cases are presented in detail to illustrate the generation process of auroral kilometric radiation. The first case, which has an electron plasma frequency omega(pe) = 0.2 omega(ce) (electron cyclotron frequency) and possesses a double loss cone distribution, exhibits a strong narrow peak of the fast extraordinary mode (X mode) radiation just above the X mode cutoff frequency. The second case with omega(pe) = 0.2 omega(ce) and a single loss cone distribution shows a preferred direction of propagation for the amplified radiation. The third case with omega(pe) = 0.5 omega(ce) shows a peak in the ordinary mode (O mode) radiation. In all cases, the radiation saturates by turbulent scattering of resonant particles into the loss cone.

Wagner, J. S.

On the role of the energy of suprathermal electrons in the generation of auroral kilometric radiation

The relativistic dispersion equation based on the cyclotron maser theory for a DGH energetic electron distribution is examined in order to identify and understand the physical conditions under which fundamental O mode and second harmonic X mode radiations can dominate over fundamental X mode emission in low density auroral kilometric radiation source regions. It is found that the energy of the auroral electrons can play a significant role in determining the dominant wave mode. The temporal and spatial growth rates of both the fundamental O mode as well as the second harmonic X mode remain high for energies as low as several hundred eV of the suprathermal electrons, while the fundamental X mode is suppressed for energies no higher than approximately 1 keV due to its relativistic resonance condition.

Wong, H. K.

Compact, Highly Stable Ion Atomic Clock

A mercury-ion clock now at the breadboard stage of development (see figure) has a stability comparable to that of a hydrogen-maser clock: In tests, the clock exhibited an Allan deviation of between 2 x 10(exp -13) and 3 x 10(exp -13) at a measurement time of 1 second, averaging to about 10(exp -15) at 1 day. However, the clock occupies a volume of only about 2 liters . about a hundredth of the volume of a hydrogen-maser clock. The ion-handling parts of the apparatus are housed in a sealed vacuum tube, wherein only a getter pump is used to maintain the vacuum. Hence, this apparatus is a prototype of a generation of small, potentially portable high-precision clocks for diverse ground- and space-based navigation and radio science applications. Furthermore, this new ion-clock technology is about 100 times more stable and precise than the rubidium atomic clocks currently in use in the NAV STAR GPS Earth-orbiting satellites. In this clock, mercury ions are shuttled between a quadrupole and a 16-pole linear radio-frequency trap. In the quadrupole trap, the ions are tightly confined and optical state selection from a Hg-202 radio-frequency-discharge ultraviolet lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions resonant at frequency of about 40.507 GHz are interrogated by use of a microwave beam at that frequency. The trapping of ions effectively eliminates the frequency pulling caused by wall collisions inherent to gas-cell clocks. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave- resonance process, so that each of these processes can be optimized independently of the other. The basic ion-shuttling, two-trap scheme as described thus far is not new: it has been the basis of designs of prior larger clocks. The novelty of the present development lies in major redesigns of its physics package (the ion traps and the vacuum and optical subsystems) to effect the desired reduction of size to a volume of no more than a couple of liters. The redesign effort has included selection of materials for the vacuum tube, ion trap, and ultraviolet windows that withstand bakeout at a temperature of approx.450 C in preparation for sealing the tube to contain the vacuum. This part of the redesign effort follows the approach taken in the development of such other vacuum-tube electronic components as flight traveling- wave-tube amplifiers having operational and shelf lives as long as 15 years. The redesign effort has also included a thorough study of residual-gas-induced shifts of the ion-clock frequency and a study of alternative gases as candidates for use as a buffer gas within the sealed tube. It has been found that neon is more suitable than is helium, which has been traditionally used for this purpose, in that the pressure-induced frequency pulling by neon is between a third and a half of that of helium. In addition, because neon diffuses through solids much more slowly than does helium, the loss of neon by diffusion over the operational lifetime is expected to be negligible.

Prestage, John