Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

MARS Science Laboratory Post-Landing Location Estimation Using Post2 Trajectory Simulation

The Mars Science Laboratory (MSL) Curiosity rover landed safely on Mars August 5th, 2012 at 10:32 PDT, Earth Received Time. Immediately following touchdown confirmation, best estimates of position were calculated to assist in determining official MSL locations during entry, descent and landing (EDL). Additionally, estimated balance mass impact locations were provided and used to assess how predicted locations compared to actual locations. For MSL, the Program to Optimize Simulated Trajectories II (POST2) was the primary trajectory simulation tool used to predict and assess EDL performance from cruise stage separation through rover touchdown and descent stage impact. This POST2 simulation was used during MSL operations for EDL trajectory analyses in support of maneuver decisions and imaging MSL during EDL. This paper presents the simulation methodology used and results of pre/post-landing MSL location estimates and associated imagery from Mars Reconnaissance Orbiter s (MRO) High Resolution Imaging Science Experiment (HiRISE) camera. To generate these estimates, the MSL POST2 simulation nominal and Monte Carlo data, flight telemetry from onboard navigation, relay orbiter positions from MRO and Mars Odyssey and HiRISE generated digital elevation models (DEM) were utilized. A comparison of predicted rover and balance mass location estimations against actual locations are also presented.

Davis, J. L.↗

Locating the LCROSS Impact Craters

The Lunar CRater Observations and Sensing Satellite (LCROSS) mission impacted a spent Centaur rocket stage into a permanently shadowed region near the lunar south pole. The Sheperding Spacecraft (SSC) separated approx. 9 hours before impact and performed a small braking maneuver in order to observe the Centaur impact plume, looking for evidence of water and other volatiles, before impacting itself. This paper describes the registration of imagery of the LCROSS impact region from the mid- and near-infrared cameras onboard the SSC, as well as from the Goldstone radar. We compare the Centaur impact features, positively identified in the first two, and with a consistent feature in the third, which are interpreted as a 20 m diameter crater surrounded by a 160 m diameter ejecta region. The images are registered to Lunar Reconnaisance Orbiter (LRO) topographical data which allows determination of the impact location. This location is compared with the impact location derived from ground-based tracking and propagation of the spacecraft's trajectory and with locations derived from two hybrid imagery/trajectory methods. The four methods give a weighted average Centaur impact location of −84.6796 deg, −48.7093 deg, with a 1σ uncertainty of 115 m along latitude, and 44 m along longitude, just 146 m from the target impact site. Meanwhile, the trajectory-derived SSC impact location is −84.719 deg, −49.61 deg, with a 1 alpha uncertainty of 3 m along the Earth vector and 75 m orthogonal to that, 766 m from the target location and 2.803 km south-west of the Centaur impact. We also detail the Centaur impact angle and SSC instrument pointing errors. Six high-level LCROSS mission requirements are shown to be met by wide margins. We hope that these results facilitate further analyses of the LCROSS experiment data and follow-up observations of the impact region

LCROSS↗

Optimization of Microphone Locations for Acoustic Liner Impedance Eduction

Two impedance eduction methods are explored for use with data acquired in the NASA Langley Grazing Flow Impedance Tube. The first is an indirect method based on the convected Helmholtz equation, and the second is a direct method based on the Kumaresan and Tufts algorithm. Synthesized no-flow data, with random jitter to represent measurement error, are used to evaluate a number of possible microphone locations. Statistical approaches are used to evaluate the suitability of each set of microphone locations. Given the computational resources required, small sample statistics are employed for the indirect method. Since the direct method is much less computationally intensive, a Monte Carlo approach is employed to gather its statistics. A comparison of results achieved with full and reduced sets of microphone locations is used to determine which sets of microphone locations are acceptable. For the indirect method, each array that includes microphones in all three regions (upstream and downstream hard wall sections, and liner test section) provides acceptable results, even when as few as eight microphones are employed. The best arrays employ microphones well away from the leading and trailing edges of the liner. The direct method is constrained to use microphones opposite the liner. Although a number of arrays are acceptable, the optimum set employs 14 microphones positioned well away from the leading and trailing edges of the liner. The selected sets of microphone locations are also evaluated with data measured for ceramic tubular and perforate-over-honeycomb liners at three flow conditions (Mach 0.0, 0.3, and 0.5). They compare favorably with results attained using all 53 microphone locations. Although different optimum microphone locations are selected for the two impedance eduction methods, there is significant overlap. Thus, the union of these two microphone arrays is preferred, as it supports usage of both methods. This array contains 3 microphones in the upstream hard wall section, 14 microphones opposite the liner, and 3 microphones in the downstream hard wall section.

Jones, M. G.↗

A feasibility assessment for co-locating and powering offshore aquaculture with wave energy in the United States

Offshore aquaculture and marine renewable energy (energy from waves, tides, currents, and ocean gradients) are two developing ocean-based industries. Aquaculture, an industry that has typically relied on diesel for power, is expected to grow globally, presenting an opportunity to reduce greenhouse gas emissions by switching to renewable sources as it expands. As the industry moves further offshore and is situated in more energetic environments, the prospect to co-locate offshore aquaculture with wave energy increases. To improve understanding of this potential, a feasibility assessment was completed to estimate the energy needs and wave resource required to power offshore finfish aquaculture operations. The study found it is possible to power offshore aquaculture operations entirely with wave energy. A spatial analysis was then performed to assess the suitability of co-locating offshore finfish aquaculture and wave energy off California and Hawaii. Suitable locations were identified offshore of O’ahu, Hawaii, and northern California. Southern California was also assessed, using a lower wave resource, based on study areas evaluated by the National Oceanic and Atmospheric Administration to identify Aquaculture Opportunity Areas, and while limited there are suitable locations that may warrant further evaluation. This study presents an analysis into the potential to pair wave energy with offshore aquaculture, and how various factors can help determine suitable areas for co-location. The analyses developed in this study will support future identification of potential sites for development and decision-making to optimize the success of co-locating wave energy resources and offshore finfish aquaculture.

16 TIDAL AND WAVE POWER↗

Impact of gas injection location and divertor surface material on ITER fusion power operation phase divertor performance assessed with SOLPS-ITER *

Abstract The ITER divertor design and performance assessment, primarily based on the SOLPS-4.3 burning plasma database (Pitts R. et al 2019 Nucl. Mater. Energy 20 100696), assumes the use of beryllium (Be) as the divertor surface material and the injection of gas from the main chamber top. However, the current ITER baseline favors gas injection from the more toroidally symmetric sub-divertor region. This paper evaluates the implications of these assumptions for divertor performance in the ITER fusion power operation phase. The impact of the divertor surface material and the gas injection location on the main ions mirrors the hydrogen only low power phase scenario shown in Park J.-S. et al (2020 Nucl. Fusion 61 016021). However, during burning plasma operation, extrinsic impurity seeding will be required. In the case of neon (Ne), studied here, impurity retention is influenced by both the divertor surface material and the fueling location. Neon leakage increases due to more energetic reflection from tungsten than beryllium, but equivalent divertor performance can be achieved by adjusting the neon seeding rate. While the impurity seeding location does not affect the distributions of impurity or radiation, the fueling location does. Top fueling provides local ionization sources mainly in the mid-SOL under detached conditions, enhancing divergences of the flux there (source-driven flow), bringing stagnation points close to the fueling location, and equilibrating flows towards both targets. In contrast, the global flow pattern (in the absence of fluid drifts) in the case of sub-divertor fueling is biased towards the inner target. Impurity flows, driven by force balance, largely mirror those of the main ion flow, including the stagnation point. The case with top fueling enhances Ne retention and corresponding radiation in the outer divertor, effectively reducing the total and peak target heat fluxes by 20%–40%, compared to the case with divertor fueling. Meanwhile, the case with outer target fueling also achieves similar reductions by enhancing plasma-neutral interactions. These results suggest the possibility that the selection of the fueling location and throughput can be used as an actuator to control impurity divertor retention and divertor radiation asymmetry.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A New Method for Predicting Turbulent Flow Reattachment Location: Application of Stratford Criterion for Reattaching Flows

A new method for predicting turbulent flow reattachment location has been developed. The method predicts the reattachment location using the surface static pressure distribution and requires only a single empirical parameter. The method is based on the well-known Stratford’s flow separation criterion, which results from an approximate solution to the equations of motion within the boundary layer. Because of the large pressure rise, the original Stratford separation criterion is not valid for reattaching flows. In order to apply the Stratford criterion for reattaching flows, the reference location was moved to the pressure drop conditions instead of pressure rise conditions. In addition, the pressure distribution was scaled using a technique that was originally introduced for supersonic base flows. A new empirical parameter was also obtained for the modified Stratford criterion. The method has been tested for 30 different separated flow configurations from the literature. The variety of test cases include subsonic flows, transonic flows, 2D flows, and axisymmetric flows, with experimental as well as high resolution numerical simulation results. The flow reattachment predictions with the new method agree very well with the reported data. The error is less than 5% and typically about 2%. The new method is an extremely simple and a quick way of finding the reattachment location. Given the complexities of the existing experimental techniques for finding the reattachment location, the method easily and quickly provides the flow reattachment location, which could be used to estimate the physical extent of separation bubbles, as a performance index for flow control methods, or to assess the predictive capability of turbulence models.

Flow reattachment location↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning‐Assisted Microearthquake Location Workflow for Monitoring the Newberry Enhanced Geothermal System

Abstract Enhanced geothermal systems (EGS) offer a sustainable energy source but face challenges in accurately locating microearthquakes induced during reservoir stimulation. Locating these microearthquakes provides reliable feedback on the stimulation progress. Current deep learning methods for locating earthquakes require extensive data sets for training, which is problematic as detected microearthquakes are often limited. To address the scarcity of training data, we propose a practical workflow using probabilistic multilayer perceptron (PMLP) which predicts microearthquake locations from cross‐correlation time lags in waveforms. Utilizing a 3D velocity model of Newberry site derived from ambient noise interferometry, we generate numerous synthetic microearthquakes and 3D acoustic waveforms for PMLP training. Accurate synthetic tests prompt us to apply the trained network to the 2012 and 2014 stimulation field waveforms. To enhance the accuracy of source localization, we carefully handpick the P‐arrival times. Predictions on the 2012 stimulation data set show major microseismic activity at depths of 0.5–1.2 km, correlating with a known casing leakage scenario. In the 2014 data set, the majority of predictions concentrate at 2.0–2.9 km depths, consistent with results obtained from conventional physics‐based inversion, and align with the presence of natural fractures from 2.0 to 2.7 km. We validate our findings by comparing the synthetic and field picks, demonstrating a satisfactory match for the first arrivals. By combining the benefits of quick inference speeds and accurate location predictions, we demonstrate the feasibility of using realistic synthetic data set to locate microseismicity for EGS monitoring.

15 GEOTHERMAL ENERGY↗

A physics‐informed learning technique for fault location of DC microgrids using traveling waves

Abstract Fast and accurate fault location in DC power systems is of particular importance to ensure their reliable operation. One of the approaches for implementing a fast‐tripping protection scheme is to use Traveling waves (TW) initiated by a fault scenario. This paper proposes a physics‐informed machine learning approach that utilizes TWs for fault location in DC microgrids. TWs are extracted by the so‐called multiresolution analysis which identifies the TW's wavelet coefficients for multiple frequency ranges. This paper deploys Parseval's theorem to find the energy of wavelet coefficients as a quantitative metric for describing TWs. The hypothesis of this paper is that once the Parseval energy curves for a specific cable are extracted, they can be utilized to locate faults along with that cable regardless of the DC system in which the cable is deployed. The fault location algorithm uses Parseval energy curves to train a Gaussian Process (GP) estimator. With the Parseval energy values of measured current at the protection device location, the GP estimator is able to estimate fault locations with high accuracy. The effectiveness of the proposed algorithm is verified by simulating a DC microgrid system in PSCAD/EMTDC.

Paruthiyil, Sajay Krishnan↗

Evaluating Manual Sampling Locations for Regulatory and Emergency Response

Drinking water systems commonly use manual or grab sampling to monitor water quality, identify or confirm issues, and verify that corrective or emergency response actions have been effective. In this paper, the effectiveness of regulatory sampling locations for emergency response is explored. An optimization formulation based on the literature was used to identify manual sampling locations to maximize overall nodal coverage of the system. Results showed that sampling locations could be effective in confirming incidents for which they were not designed. When evaluating sampling locations optimized for emergency response against regulatory scenarios, the average performance was reduced by 3%–4%, while using optimized regulatory sampling locations for emergency response reduced performance by 7%–10%. Secondary constraints were also included in the formulation to ensure geographical and water age diversity with minimal impact on the performance. This work highlighted that regulatory sampling locations provide value in responding to an emergency for these networks.

54 ENVIRONMENTAL SCIENCES↗

Detection of astrophysical neutrinos at prospective locations of dark matter detectors

We study the prospects for detection of solar, atmospheric neutrino, and diffuse supernova neutrino background (DSNB) fluxes at future large-scale dark matter detectors through both electron and nuclear recoils. We specifically examine how the detection prospects change for several prospective detector locations [Sanford Underground Research Facility (SURF), SNOlab, Gran Sasso, China Jinping Underground Laboratory (CJPL), and Kamioka] and improve upon the statistical methodologies used in previous studies. Because of its ability to measure lower neutrino energies than other locations, we find that the best prospects for the atmospheric neutrino flux are at the SURF location, while the prospects are weakest at CJPL because it is restricted to higher neutrino energies. On the contrary, the prospects for the DSNB are best at CJPL, due largely to the reduced atmospheric neutrino background at this location. Including full detector resolution and efficiency models, the CNO component of the solar flux is detectable via the electron recoil channel with exposures of ∼ 10 3 ton-yr for all locations. These results highlight the benefits for employing two detector locations, one at high and one at low latitude. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

A Variational Method for Analyzing Vortex Flows in Radar-Scanned Tornadic Mesocyclones. Part III: Sensitivities to Vortex Center Location Errors

Abstract When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an important issue concerning the sensitivities of analyzed vortex flow (VF) fields by the VF-Var (formulated in Part I of this paper series and tested in Part II) to vortex center location errors, denoted by Δ x c . Numerical experiments are performed to address this issue with the following findings: The increase of |Δ x c | from zero to a half of vortex core radius causes large analysis error increases in the vortex core but the increased analysis errors decrease rapidly away from the vortex core especially for dual-Doppler analyses. The increased horizontal-velocity errors in the vortex core are mainly in the Δ x c -normal component, because this component varies much more rapidly than the other component along the Δ x c direction in the vortex core. The vertical variations of Δ x c distort the vertical correlation structure of Δ x c -dislocated VF-dependent background error covariance, which can increase the analysis errors in the vortex core. The dual-Doppler analyses have adequate accuracies outside the vortex core even when |Δ x c | increases to a half of vortex core radius, while single-Doppler analyses can also have adequate accuracies outside the vortex core mainly for the single-Doppler-observed velocity component. The sensitivities to Δ x c are largely unaffected by the vortex slanting. The above findings are important and useful for assessing the accuracies of analyzed VFs for real radar-observed tornadic mesocyclones. Significance Statement When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an issue concerning the sensitivity of analyzed vortex flow (VF) by the VF-Var (formulated in Part I of this paper series and tested with simulated radar observations in Part II) to vortex center location error. This issue and its required investigations are very important for the VF-Var to be applied to real radar-observed tornadic mesocyclones, especially in an operational setting with the WSR-88Ds. Numerical experiments are performed to address this issue. The findings from these experiments are important and useful for assessing the accuracies of VF-Var analyzed VF fields for real radar-observed tornadic mesocyclones.

Xu, Qin↗

Geometric Interpretation of the Cluster Location Problem Part II: Application to the Pahala, Hawaii, Earthquake Sequence

In the companion “Theory” article, we presented a new framing of the seismic location problem in terms of differential geometry (Harris et al., 2025). From that viewpoint, we developed a “project and correct” approach for estimating the relative locations of earthquakes. Here, in this study, we use project and correct to estimate high-precision relative locations of events from an earthquake sequence beneath the town of Pahala, Hawaii, using high-precision correlation-derived picks. The sequence was active from 2020 through 2022 and produced many highly correlated signals at Hawaii Volcano Observatory (HVO) stations on the island of Hawaii. The data we inverted consisted of 2882 events with observations at 5 HVO stations. For comparison with the travel-time image, we also produced conventional hypocenter solutions using both the Bayesloc program (Myers et al., 2007, 2009) and a purpose-built double-difference code. There were obvious structural elements in the resulting image, the resolution of which we used to test the performance of the project and the correct algorithm. For the projection step, we first produced a 3D local basis using an singular value decomposition (SVD) of the 2882 groups of times. Projection of the travel-time vectors into this basis resulted in an image with structures similar to those produced by our conventional locators, but with distortion as predicted by theory. Removing the distortion requires an inverse operator generated from the metric tensor at the geometric centroid of the events. We compared two approaches to obtaining such an inverse operator. The first uses an estimate of the geographic centroid of the event cloud from the centroid of the travel-time data. The second approach uses the centroid of the conventionally produced locations. The first approach produces a corrected image very similar to the conventional results, but with a rotation. The corrected image produced using the conventionally derived centroid is a near-exact match to the conventional locations.

Dodge, Douglas A. [Lawrence Livermore National Lab↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Review of the November 11, 1905 Earthquake: Seismic Intensity Data, Magnitude, and Location Report

The macroseismic location and magnitude of the Shoshone 1905 earthquake has been based on the application of objective and quantitative approaches that produce estimates of earthquake source location and magnitude, and associated uncertainties. The performance of all three approaches applied depends critically on the characteristics of the seismic intensity field. Regional intensity attenuation relations were derived based on a calibration set of earthquakes and then, the procedure was validated using three independent very recent events. The macroseismic epicenter location was determined by either a grid search procedure, the spatial distribution of the sites experiencing the largest intensities, or a combination of both. The macroseismic magnitude estimates are based on the derived regional intensity attenuation relations. There is consistency in the location and magnitude of the November 1905 earthquake as obtained by the three methods. The overlapping region of the 68% bootstrap resampling solutions suggests a reliable epicenter location within 41.550N ? 42.060N and 113.478W ? 112.320W. This region encloses the original Oaks (1992) epicenter location. Macroseismic magnitude estimates range between 5.87 and 6.05.

58 GEOSCIENCES↗

Locating Seismic Events with Local-Distance Data

As the seismic monitoring community advances toward detecting, identifying, and locating ever-smaller natural and anthropogenic events, the need is constantly increasing for higher resolution, higher fidelity data, models, and methods for accurately characterizing events. Local-distance seismic data provide robust constraints on event locations, but also introduce complexity due to the significant geologic heterogeneity of the Earth’s crust and upper mantle, and the relative sparsity of data that often occurs with small events recorded on regional seismic networks. Identifying the critical characteristics for improving local-scale event locations and the factors that impact location accuracy and reliability is an ongoing challenge for the seismic community. Using Utah as a test case, we examine three data sets of varying duration, finesse, and magnitude to investigate the effects of local earth structure and modeling parameters on local-distance event location precision and accuracy. We observe that the most critical elements controlling relocation precision are azimuthal coverage and local-scale velocity structure, with tradeoffs based on event depth, type, location, and range.

42 ENGINEERING↗

Incorporating new locations into a hydrodynamic model using ArcGIS Pro

ALGE3D is a 3-D hydrodynamic model developed at the Savannah River National Laboratory to predict pollutant dispersion. The model has several predefined locations incorporated, however adding new locations into ALGE3D is manually intensive and time-consuming. In the event of an emergency, ALGE3D can only be used if an event occurs at one of the predefined locations incorporated into the GUI. This project focuses on streamlining the integration of new locations into ALGE3D by utilizing tools in ArcGIS Pro. The Stream Order tool was used to delineate streams and assign them an order, using the Strahler method, versus manually defining these streams in Microsoft Excel. This work advances development to turn ALGE3D into a product for emergency response use by allowing the user to incorporate a new location into ALGE3D quickly, should an event occur at a location that is not already predefined.

54 ENVIRONMENTAL SCIENCES↗

Update of Receptor Locations for INL National Emissions Standard for Hazardous Air Pollutants (NESHAP) Assessments

This report documents the selection of updated public receptor locations for use in conducting regulatory assessments of radioactive air emissions for Idaho National Laboratory (INL) facilities. The basis for this receptor location analysis is found in 40 CFR 61 Subpart H, “National Emissions Standards for Emissions of Radionuclide Other than Radon from Department of Energy Facilities,” where the requirements for identifying National Emission Standards for Hazardous Air Pollutants (NESHAP) receptor locations are outlined. Receptor locations (residences, schools, businesses, or farm operations) were identified using high-resolution satellite imagery. This assessment identified 31 unique receptor locations for all INL Site facilities, and 30 receptor locations for INL in-town facilities that have the potential to emit radioactive materials. Identification of receptors for each in-town facility is new to this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗